The DOI matches its Crossref record.
Practical cone-beam algorithm
Abstract
A convolution-backprojection formula is deduced for direct reconstruction of a three-dimensional density function from a set of two-dimensional projections. The formula is approximate but has useful properties, including errors that are relatively small in many practical instances and a form that leads to convenient computation. It reduces to the standard fan-beam formula in the plane that is perpendicular to the axis of rotation and contains the point source. The algorithm is applied to a mathematical phantom as an example of its performance. 1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
du Plessis, A., Yadroitsev, I., Yadroitsava, I., & Le Roux, S. G. (2018) · 3D Printing and Additive Manufacturing · doi:10.1089/3dp.2018.0060 · Cited by 550
High resolution X-ray computed tomography: an emerging tool for small animal cancer research
Paulus, M. J., Gleason, S. S., Kennel, S. J., Hunsicker, P. R., & Johnson, D. K. (2000) · Neoplasia · doi:10.1038/sj.neo.7900069 · Cited by 490
Suprachoroidal drug delivery to the back of the eye using hollow microneedles
Patel, S. R., Lin, A. S. P., Edelhauser, H. F., & Prausnitz, M. R. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0271-y · Cited by 330
Oxytocin neurons enable social transmission of maternal behaviour
Carcea, I., Caraballo, N. L., Marlin, B. J., Ooyama, R., Riceberg, J. S., Mendoza Navarro, J. M., Opendak, M., Diaz, V. E., Schuster, L., Alvarado Torres, M. I., et al. (2021) · Nature · doi:10.1038/s41586-021-03814-7 · Cited by 268
Utilization of urea as an accessible superplasticizer on the moon for lunar geopolymer mixtures
Pilehvar, S., Arnhof, M., Pamies, R., Valentini, L., & Kjøniksen, A.-L. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.119177 · Cited by 139
Sisniega, A., Zbijewski, W., Badal, A., Kyprianou, I. S., Stayman, J. W., Vaquero, J. J., & Siewerdsen, J. H. (2013) · Medical Physics · doi:10.1118/1.4801895 · Cited by 117
High-performance cone beam reconstruction using CUDA compatible GPUs
Okitsu, Y., Ino, F., & Hagihara, K. (2010) · Parallel Computing · doi:10.1016/j.parco.2010.01.004 · Cited by 70
View-interpolation of sparsely sampled sinogram using convolutional neural network
Lee, H., Lee, J., & Cho, S. (2017) · SPIE Proceedings · doi:10.1117/12.2254244 · Cited by 74
Pilehvar, S., Arnhof, M., Erichsen, A., Valentini, L., & Kjøniksen, A. (2021) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2021.01.124 · Cited by 69
GPU-based cone beam computed tomography
Noël, P. B., Walczak, A. M., Xu, J., Corso, J. J., Hoffmann, K. R., & Schafer, S. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.08.006 · Cited by 67
3D-2D Registration for Surgical Guidance: Effect of Projection View Angles on Registration Accuracy
Uneri, A., Otake, Y., Wang, A. S., Kleinszig, G., Vogt, S., Khanna, A. J., & Siewerdsen, J. H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/2/271 · Cited by 53
3D reconstruction from projection matrices in a C-arm based 3D-angiography system
Navab, N., Bani-Hashemi, A., Nadar, M. S., Wiesent, K., Durlak, P., Brunner, T., Barth, K., & Graumann, R. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056194 · Cited by 50
Noise correlation in CBCT projection data and its application for noise reduction in low‐dose CBCT
Zhang, H., Ouyang, L., Ma, J., Huang, J., Chen, W., & Wang, J. (2014) · Medical Physics · doi:10.1118/1.4865782 · Cited by 47
Preclinical radiation dosimetry for the novel SV2A radiotracer [18F]UCB-H
Bretin, F., Warnock, G., Bahri, M. A., Aerts, J., Mestdagh, N., Buchanan, T., Valade, A., Mievis, F., Giacomelli, F., Lemaire, C., et al. (2013) · EJNMMI Research · doi:10.1186/2191-219x-3-35 · Cited by 43
X-Ray PoseNet: 6 DoF Pose Estimation for Mobile X-Ray Devices
Bui, M., Albarqouni, S., Schrapp, M., Navab, N., & Ilic, S. (2017) · 2017 IEEE Winter Conference on Applications of Computer Vision (WACV) · doi:10.1109/wacv.2017.120 · Cited by 27
Evaluation of state-of-the-art hardware architectures for fast cone-beam CT reconstruction
Scherl, H., Kowarschik, M., Hofmann, H. G., Keck, B., & Hornegger, J. (2012) · Parallel Computing · doi:10.1016/j.parco.2011.10.004 · Cited by 25
Blas, J. G., Abella, M., Isaila, F., Carretero, J., & Desco, M. (2014) · Journal of Systems and Software · doi:10.1016/j.jss.2014.03.083 · Cited by 21
Earth’s oldest ‘Bobbit worm’ – gigantism in a Devonian eunicidan polychaete
Eriksson, M. E., Parry, L. A., & Rudkin, D. M. (2017) · Scientific Reports · doi:10.1038/srep43061 · Cited by 11
Oxytocin Neurons Enable Social Transmission of Maternal Behavior
Carcea, I., Caraballo, N. L., Marlin, B. J., Ooyama, R., Riceberg, J. S., Mendoza Navarro, J. M., Opendak, M., Diaz, V. E., Schuster, L., Alvarado Torres, M. I., et al. (2019) · doi:10.1101/845495 · Cited by 8
Top-Level Design and Simulated Performance of the First Portable CT-MR Scanner
Peng, Y., Li, M., Grandinetti, J., Wang, G., & Jia, X. (2022) · IEEE Access · doi:10.1109/access.2022.3208278 · Cited by 4
“ing the standard Fredkamp-Davis-Kress algorithm [20].”
Metadata
- Authors
- Feldkamp, L. A., Davis, L. C., & Kress, J. W.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1984-06-01
- Volume
- 1
- Issue
- 6
- Pages
- 612
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2157812230
- Cited by
- 6,319
- References
- 0
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.