The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
High-speed spectral-domain optical coherence tomography at 13 μm wavelength
Open accessAbstract
We demonstrate a high-speed spectral domain optical coherence tomography (SD-OCT) system capable of acquiring individual axial scans in 24.4 micros at a rate of 19,000 axial scans per second, using an InGaAs line scan camera and broadband light source centered at 1.31microm. Sensitivity of >105 dB over a 2-mm depth range was obtained with a free-space axial resolution of 12-14 microm, in agreement with our signal-to-noise ratio predictions. Images of human tissue obtained in vivo with SD-OCT show similar penetration depths to those obtained with state-of-the-art time domain OCT despite the ten-fold higher image acquisition speed. These results demonstrate the potential of 1.3 microm SD-OCT for high-speed and high-sensitivity imaging in patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,794
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,250
Self-citationIn vivo human retinal imaging by Fourier domain optical coherence tomography
Wojtkowski, M., Leitgeb, R., Kowalczyk, A., Bajraszewski, T., & Fercher, A. F. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1482379 · Cited by 913
High-speed optical frequency-domain imaging
Yun, S., Tearney, G., de Boer, J., Iftimia, N., & Bouma, B. (2003) · Optics Express · doi:10.1364/oe.11.002953 · Cited by 865
Self-citationQuantification of Macrophage Content in Atherosclerotic Plaques by Optical Coherence Tomography
Tearney, G. J., Yabushita, H., Houser, S. L., Aretz, H. T., Jang, I.-K., Schlendorf, K. H., Kauffman, C. R., Shishkov, M., Halpern, E. F., & Bouma, B. E. (2003) · Circulation · doi:10.1161/01.cir.0000044384.41037.43 · Cited by 704
Self-citationOptical coherence tomography using a frequency-tunable optical source
Chinn, S. R., Swanson, E. A., & Fujimoto, J. G. (1997) · Optics Letters · doi:10.1364/ol.22.000340 · Cited by 666
In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography
Nassif, N., Cense, B., Hyle Park, B., Yun, S. H., Chen, T. C., Bouma, B. E., Tearney, G. J., & de Boer, J. F. (2004) · Optics Letters · doi:10.1364/ol.29.000480 · Cited by 498
Self-citationSpectral resolution and sampling issues in Fourier-transform spectral interferometry
Dorrer, C., Belabas, N., Likforman, J.-P., & Joffre, M. (2000) · Journal of the Optical Society of America B · doi:10.1364/josab.17.001795 · Cited by 364
Clinical Imaging with Optical Coherence Tomography
Bouma, B. E., & Tearney, G. J. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80465-8 · Cited by 60
Self-citation
Cited by
Huber, R., Wojtkowski, M., & Fujimoto, J. G. (2006) · Optics Express · doi:10.1364/oe.14.003225 · Cited by 982
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
In Vivo Characterization of Coronary Atherosclerotic Plaque by Use of Optical Coherence Tomography
Jang, I.-K., Tearney, G. J., MacNeill, B., Takano, M., Moselewski, F., Iftima, N., Shishkov, M., Houser, S., Aretz, H. T., Halpern, E. F., et al. (2005) · Circulation · doi:10.1161/01.cir.0000159354.43778.69 · Cited by 896
Self-citationAssessment of Culprit Lesion Morphology in Acute Myocardial Infarction
Kubo, T., Imanishi, T., Takarada, S., Kuroi, A., Ueno, S., Yamano, T., Tanimoto, T., Matsuo, Y., Masho, T., Kitabata, H., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.082 · Cited by 867
Detection of Macular Ganglion Cell Loss in Glaucoma by Fourier-Domain Optical Coherence Tomography
Tan, O., Chopra, V., Lu, A. T.-H., Schuman, J. S., Ishikawa, H., Wollstein, G., Varma, R., & Huang, D. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.05.025 · Cited by 665
Metadata
- Authors
- Yun, S., Tearney, G., Bouma, B., Park, B., & de Boer, J.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2003-12-29
- Volume
- 11
- Issue
- 26
- Pages
- 3598
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2079115732
- Cited by
- 399
- References
- 10
- FWCI
- 14.09
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-speed spectral-domain optical coherence tomography at 13 μm wavelength. https://app.cochat.ai/papers/10.1364/oe.11.003598
- The paper
- Yun, S., Tearney, G., Bouma, B., Park, B., & de Boer, J. (2003). High-speed spectral-domain optical coherence tomography at 13 μm wavelength. Optics Express. https://doi.org/10.1364/oe.11.003598
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.