The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Three dimensional optical angiography
Open accessAbstract
With existing optical imaging techniques three-dimensional (3-D) mapping of microvascular perfusion within tissue beds is severely limited by the efficient scattering and absorption of light by tissue. To overcome these limitations we have developed a method of optical angiography (OAG) that can generate 3-D angiograms within millimeter tissue depths by analyzing the endogenous optical scattering signal from an illuminated sample. The technique effectively separates the moving and static scattering elements within tissue to achieve high resolution images of blood flow, mapped into the 3-D optically sectioned tissue beds, at speeds that allow for perfusion assessment in vivo. Its development has its origin in Fourier domain optical coherence tomography. We used OAG to visualize the cerebral microcirculation, of adult living mice through the intact cranium, measurements which would be difficult, if not impossible, with other optical imaging techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Boppart, S. A., Pitris, C., Southern, J. F., & Fujimoto, J. G. (1997) · Science · doi:10.1126/science.276.5321.2037 · Cited by 1,364
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
Microbubbles in medical imaging: current applications and future directions
Lindner, J. R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1417 · Cited by 872
Theory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
Self-citationMakita, S., Hong, Y., Yamanari, M., Yatagai, T., & Yasuno, Y. (2006) · Optics Express · doi:10.1364/oe.14.007821 · Cited by 594
Spectroscopic optical coherence tomography
Morgner, U., Drexler, W., Kärtner, F. X., Li, X. D., Pitris, C., Ippen, E. P., & Fujimoto, J. G. (2000) · Optics Letters · doi:10.1364/ol.25.000111 · Cited by 516
A product theorem for Hilbert transforms
Bedrosian, E. (1963) · Proceedings of the IEEE · doi:10.1109/proc.1963.2308 · Cited by 489
White, B. R., Pierce, M. C., Nassif, N., Cense, B., Park, B. H., Tearney, G. J., Bouma, B. E., Chen, T. C., & de Boer, J. F. (2003) · Optics Express · doi:10.1364/oe.11.003490 · Cited by 457
A Product Theorem for Hilbert Transforms
Bedrosian, E. (1962) · RAND Corporation eBooks · doi:10.7249/rm3439 · Cited by 403
Spectral resolution and sampling issues in Fourier-transform spectral interferometry
Dorrer, C., Belabas, N., Likforman, J.-P., & Joffre, M. (2000) · Journal of the Optical Society of America B · doi:10.1364/josab.17.001795 · Cited by 364
In vivo cellular optical coherence tomography imaging
Boppart, S. A., Bouma, B. E., Pitris, C., Southern, J. F., Brezinski, M. E., & Fujimoto, J. G. (1998) · Nature Medicine · doi:10.1038/nm0798-861 · Cited by 268
Spectral measurement of absorption by spectroscopic frequency-domain optical coherence tomography
Leitgeb, R., Wojtkowski, M., Kowalczyk, A., Hitzenberger, C. K., Sticker, M., & Fercher, A. F. (2000) · Optics Letters · doi:10.1364/ol.25.000820 · Cited by 267
In vivo imaging of the diseased nervous system
Misgeld, T., & Kerschensteiner, M. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1905 · Cited by 200
Jiao, S., & Wang, L. V. (2002) · Optics Letters · doi:10.1364/ol.27.000101 · Cited by 163
OCT-based elastography for large and small deformations
Kirkpatrick, S. J., Wang, R. K., & Duncan, D. D. (2006) · Optics Express · doi:10.1364/oe.14.011585 · Cited by 153
Self-citationIn vivo full range complex Fourier domain optical coherence tomography
Wang, R. K. (2007) · Applied Physics Letters · doi:10.1063/1.2437682 · Cited by 151
Self-citationIn Vivo Imaging of Human Retinal Flow Dynamics by Color Doppler Optical Coherence Tomography
Yazdanfar, S., Rollins, A. M., & Izatt, J. A. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.2.235 · Cited by 125
Modelling optical properties of soft tissue by fractal distribution of scatterers
Wang, R. K. (2000) · Journal of Modern Optics · doi:10.1080/09500340008231409 · Cited by 118
Self-citationHigh speed full range complex spectral domain optical coherence tomography
G�tzinger, E., Pircher, M., Leitgeb, R. A., & Hitzenberger, C. K. F. (2005) · Optics Express · doi:10.1364/opex.13.000583 · Cited by 112
Cited by
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., et al. (2012) · Optics Express · doi:10.1364/oe.20.004710 · Cited by 1,841
Optical coherence tomography angiography
Spaide, R. F., Fujimoto, J. G., Waheed, N. K., Sadda, S. R., & Staurenghi, G. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.11.003 · Cited by 1,779
Kashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Self-citationJia, Y., Bailey, S. T., Hwang, T. S., McClintic, S. M., Gao, S. S., Pennesi, M. E., Flaxel, C. J., Lauer, A. K., Wilson, D. J., Hornegger, J., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1500185112 · Cited by 665
Park, D.-W., Schendel, A. A., Mikael, S., Brodnick, S. K., Richner, T. J., Ness, J. P., Hayat, M. R., Atry, F., Frye, S. T., Pashaie, R., et al. (2014) · Nature Communications · doi:10.1038/ncomms6258 · Cited by 565
Self-citation
Metadata
- Authors
- Wang, R. K., Jacques, S. L., Ma, Z., Hurst, S., Hanson, S. R., & Gruber, A.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2007-04-02
- Volume
- 15
- Issue
- 7
- Pages
- 4083
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1976553652
- Cited by
- 627
- References
- 22
- FWCI
- 15.54
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.