Simple and robust image-based autofocusing for digital microscopy
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
A simple image-based autofocusing scheme for digital microscopy is demonstrated that uses as few as two intermediate images to bring the sample into focus. The algorithm is adapted to a commercial inverted microscope and used to automate brightfield and fluorescence imaging of histopathology tissue sections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stummer, W., Pichlmeier, U., Meinel, T., Wiestler, O. D., Zanella, F., & Reulen, H.-J. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70665-9 · Cited by 3,423
Looking and listening to light: the evolution of whole-body photonic imaging
Ntziachristos, V., Ripoll, J., Wang, L. V., & Weissleder, R. (2005) · Nature Biotechnology · doi:10.1038/nbt1074 · Cited by 1,557
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Nayar, S. K., & Nakagawa, Y. (1994) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.308479 · Cited by 1,205
Ntziachristos, V., Bremer, C., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1524-x · Cited by 982
Fluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827
Concurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
Automated subcellular localization and quantification of protein expression in tissue microarrays
Camp, R. L., Chung, G. G., & Rimm, D. L. (2002) · Nature Medicine · doi:10.1038/nm791 · Cited by 764
Pogue, B. W., Poplack, S. P., McBride, T. O., Wells, W. A., Osterman, K. S., Österberg, U. L., & Paulsen, K. D. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja51261 · Cited by 471
Culver, J. P., Durduran, T., Furuya, D., Cheung, C., Greenberg, J. H., & Yodh, A. G. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000076703.71231.bb · Cited by 420
Comparison of autofocus methods for automated microscopy
Firestone, L., Cook, K., Culp, K., Talsania, N., & Preston, K. (1991) · Cytometry · doi:10.1002/cyto.990120302 · Cited by 348
Fluorescence-enhanced, near infrared diagnostic imaging with contrast agents
Sevick-Muraca, E. M., Houston, J. P., & Gurfinkel, M. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00356-3 · Cited by 328
MRI-Guided Diffuse Optical Spectroscopy of Malignant and Benign Breast Lesions
Ntziachristos, V., Yodh, A. G., Schnall, M. D., & Chance, B. (2002) · Neoplasia · doi:10.1038/sj.neo.7900244 · Cited by 321
Three-dimensional optical tomography of the premature infant brain
Hebden, J. C., Gibson, A., Yusof, R. M., Everdell, N., Hillman, E. M. C., Delpy, D. T., Arridge, S. R., Austin, T., Meek, J. H., & Wyatt, J. S. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/23/303 · Cited by 288
Partridge, S. C., Gibbs, J. E., Lu, Y., Esserman, L. J., Tripathy, D., Wolverton, D. S., Rugo, H. S., Hwang, E. S., Ewing, C. A., & Hylton, N. M. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.184.6.01841774 · Cited by 278
An automated microscope for cytologic research a preliminary evaluation.
Brenner, J. F., Dew, B. S., Horton, J., King, T., Neurath, P. W., & Selles, W. D. (1976) · Journal of Histochemistry & Cytochemistry · doi:10.1177/24.1.1254907 · Cited by 278
Dehghani, H., Pogue, B. W., Poplack, S. P., & Paulsen, K. D. (2003) · Applied Optics · doi:10.1364/ao.42.000135 · Cited by 274
Three-dimensional optical tomography of hemodynamics in the human head
Bluestone, A. Y., Abdoulaev, G., Schmitz, C. H., Barbour, R. L., & Hielscher, A. H. (2001) · Optics Express · doi:10.1364/oe.9.000272 · Cited by 259
Patterson, M. S., & Pogue, B. W. (1994) · Applied Optics · doi:10.1364/ao.33.001963 · Cited by 248
Noninvasive measurement of neuronal activity with near-infrared optical imaging
Franceschini, M. A., & Boas, D. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.09.040 · Cited by 244
Brooksby, B., Pogue, B. W., Jiang, S., Dehghani, H., Srinivasan, S., Kogel, C., Tosteson, T. D., Weaver, J., Poplack, S. P., & Paulsen, K. D. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0509636103 · Cited by 236
Critical Comparison of 31 Commercially Available Digital Slide Systems in Pathology
Rojo, M. G., García, G. B., Mateos, C. P., García, J. G., & Vicente, M. C. (2006) · International Journal of Surgical Pathology · doi:10.1177/1066896906292274 · Cited by 228
Fluorescence Molecular Imaging of Small Animal Tumor Models
Graves, E., Weissleder, R., & Ntziachristos, V. (2004) · Current Molecular Medicine · doi:10.2174/1566524043360555 · Cited by 213
Telepathology overview: From concept to implementation
Weinstein, R. S., Descour, M. R., Liang, C., Bhattacharyya, A. K., Graham, A. R., Davis, J. R., Scott, K. M., Richter, L., Krupinski, E. A., Szymus, J., et al. (2001) · Human Pathology · doi:10.1053/hupa.2001.29643 · Cited by 210
Imaging of Spontaneous Canine Mammary Tumors Using Fluorescent Contrast Agents
Reynolds, J. S., Troy, T. L., Mayer, R. H., Thompson, A. B., Waters, D. J., Cornell, K. K., Snyder, P. W., & Sevick-Muraca, E. M. (1999) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1999.tb01953.x · Cited by 204
Automated region detection based on the contrast-to-noise ratio in near-infrared tomography
Song, X., Pogue, B. W., Jiang, S., Doyley, M. M., Dehghani, H., Tosteson, T. D., & Paulsen, K. D. (2004) · Applied Optics · doi:10.1364/ao.43.001053 · Cited by 195
Initial assessment of a simple system for frequency domain diffuse optical tomography
Pogue, B. W., Patterson, M. S., Jiang, H., & Paulsen, K. D. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/10/011 · Cited by 190
An Operational Near-Infrared Fluorescence Imaging System Prototype for Large Animal Surgery
De Grand, A. M., & Frangioni, J. V. (2003) · Technology in Cancer Research & Treatment · doi:10.1177/153303460300200607 · Cited by 189
Zhu, Q., Kurtzman, S. H., Hegde, P., Tannenbaum, S., Kane, M., Huang, M., Chen, N. G., Jagjivan, B., & Zarfos, K. (2005) · Neoplasia · doi:10.1593/neo.04526 · Cited by 174
Brooksby, B. A., Jiang, S., Dehghani, H., Pogue, B. W., Paulsen, K. D., Weaver, J. B., Kogel, C. A., & Poplack, S. P. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2098627 · Cited by 171
Real-time molecular and cellular analysis: the new frontier of drug discovery
Taylor, D. L., Woo, E. S., & Giuliano, K. A. (2001) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(00)00180-4 · Cited by 135
MRI-guided optical tomography: prospects and computation for a new imaging method
Barbour, R. L., Graber, H. L., Chang, J., Barbour, S.-L. S., Koo, P. C., & Aronson, R. (1995) · IEEE Computational Science and Engineering · doi:10.1109/99.476370 · Cited by 135
5-Aminolevulinic acid-based photodynamic detection and therapy of brain tumors (Review)
Friesen, S., Hjortland, G., Madsen, S., Hirschberg, H., Engebraten, O., Nesland, J., & Peng, Q. (2002) · International Journal of Oncology · doi:10.3892/ijo.21.3.577 · Cited by 112
Pogue, B. W., Geimer, S. D., McBride, T. O., Jiang, S., Österberg, U. L., & Paulsen, K. D. (2001) · Applied Optics · doi:10.1364/ao.40.000588 · Cited by 103
Photobleaching-based Dosimetry Predicts Deposited Dose in ALA-PpIX PDT of Rodent Esophagus
Sheng, C., Hoopes, P. J., Hasan, T. G., et al. (2007) · Photochemistry and Photobiology · doi:10.1562/2006-09-07-ra-1033 · Cited by 94
Near-infrared imaging in the small animal brain: optimization of fiber positions
Xu, H., Dehghani, H., Pogue, B. W., Springett, R., Paulsen, K. D., & Dunn, J. F. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528597 · Cited by 91
Kepshire, D. S., Davis, S. C., Dehghani, H., Paulsen, K. D., & Pogue, B. W. (2007) · Applied Optics · doi:10.1364/ao.46.001669 · Cited by 85
Increased brain tumor resection using fluorescence image guidance in a preclinical model
Bogaards, A., Varma, A. K., Collens, S., Lin, A., Giles, A., Yang, V. X. D., Bilbao, J. M., Lilge, L. D., Müller, P. J., & Wilson, B. C. (2004) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20088 · Cited by 78
Cited by
Deep learning for single-shot autofocus microscopy
Pinkard, H., Phillips, Z., Babakhani, A., Fletcher, D. A., & Waller, L. (2019) · Optica · doi:10.1364/optica.6.000794 · Cited by 166
“…can be divided into two classes: hardware-based schemes that attempt to directly measure the distance from the objective lens to the sample [1, 2, 7, 4, 29], and software-based methods that take one or more out-of-focus images and use them to determine the optimal focal position [19, 27, 11, 10].”
Method
Metadata
- Authors
- Yazdanfar, S., Kenny, K. B., Tasimi, K., Corwin, A. D., Dixon, E. L., & Filkins, R. J.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2008-05-28
- Volume
- 16
- Issue
- 12
- Pages
- 8670
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2038134596
- Cited by
- 171
- References
- 38
- FWCI
- 13.48
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.