Cited by 53Advanced Frequency and Time StandardsScientific Measurement and Uncertainty EvaluationAdvanced Electrical Measurement Techniques

SI-traceable measurement of an optical frequency at the low 10^−16 level without a local primary standard

Open access
Hachisu, Hidekazu, Petit, Gérard, Nakagawa, Fumimaru, Hanado, Yuko, Ido, Tetsuya·2017·Optics Express

Abstract

agrees with other measurements based on local state-of-the-art cesium fountains.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/oe.25.008511

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The four frequency ratios in Eq. 5 were not measured simultaneously and need to be extrapolated to common intervals using the hydrogen masers as flywheel oscillators.

    “The four frequency ratios in Eq. 5 were not measured simultaneously and need to be extrapolated to common intervals using the hydrogen masers as flywheel oscillators 34,35,85 .”

    From Intercontinental comparison of optical atomic clocks through very long baseline interferometry (2021) · cites this paper as [35]

    Section 2 (p. 4) describes intermittent Sr-clock measurements and using hydrogen masers as local flywheel oscillators to obtain a 10-day mean ratio. But Section 5 (p. 12) says the TAI-to-SI ratio is derived for the same 10-day interval through a separate TAI estimation protocol; the paper does not say that all four ratios are extrapolated using the masers. (LLM, conf=0.82)

    Experimental — accuracy not yet measured
  • The gravitational redshift induced by the different gravitational potential at the position of the optical clocks has been accounted for in the clock systematic shifts, bringing a relative correction of -1.765(2) × 10^-14 to the frequency ratio.

    “The gravitational redshift induced by the different gravitational potential at the position of the optical clocks 34,35 has been accounted for in the clock systematic shifts, bringing a relative correction of -1.765(2) × 10 -14 to the frequency ratio.”

    From Intercontinental comparison of optical atomic clocks through very long baseline interferometry (2021) · cites this paper as [35]

    Split into 2 atoms — 0 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable, 1 not checked. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured
  • They used the VLBI frequency link to compare two optical clocks: IT-Yb1 at INRIM in Torino and NICT-Sr1 in Koganei.

    “We used this VLBI frequency link to compare two optical clocks: the ytterbium-171 optical lattice clock 34 IT-Yb1 at INRIM in Torino (Italy) and the strontium-87 optical lattice clock 35,36 NICT-Sr1 in Koganei.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 6

  1. [15]15. D. W. Allan, 'Time and frequency (time-domain) characterization, estimation, and prediction of precision clocks and oscillators,' IEEE Trans. Ultrasonic, Ferro. Freq. Control UFFC 34 , 647 (1987).
  2. [17]17. F. Nakagawa, M. Imae, Y. Hanado and M. Aida, 'Development of multichannel dual-mixer time difference system to generate UTC(NICT),' IEEE Trans. Inst. Meas. 54 (2), 829 (2005).
  3. [20]20. J. Lodewyck, M. Zawada, L. Lorini, M. Gurov, P. Lemonde, 'Observation and cancellation of a perturbing dc stark shift in strontium optical lattice clocks,' IEEE Trans. Ultr. Ferr. Freq. Contr. 59 , 411 (2012).
  4. [27]27. B. Miyahara, T. Kodama, Y. Kuroishi, 'Development of new hybrid geoid model for Japan, GSIGEO2011,' Bulletin of the GSI 62 , 11 (2014).
  5. [28]28. Y. Hiyama, A. Yamagiwa, T. Kawahara, M. Iwata, Y. Fukuzaki, Y. Shouji, Y. Sato, T. Yutsudo, T. Sasaki, H. Shigematsu, H. Yamao, T. Inukai, M. Ohtaki, K. Kokado, S. Kurihara, I. Kimura, T. Tsutsumi, T. Yahagi, Y. Furuya, I. Kageyama, S. Kawamoto, K. Yamaguchi, H. Tsuji and S. Matsumura, 'Revision of Survey Results of Control Points after the 2011 off the Pacific Coast of Tohoku Earthquake,' Bulletin of the GSI 59 , 31 (2011).
  6. [35]35. T. Ido, H. Hachisu, F. Nakagawa and Y. Hanado, 'Rapid evaluation of time scale using an optical clock,' J. Phys. Conf. Ser. 723 , 012041 (2016).

Cited by

Sorted by citations

Authors
Hachisu, H., Petit, G., Nakagawa, F., Hanado, Y., & Ido, T.
Venue
Optics Express
Published
2017-04-03
Volume
25
Issue
8
Pages
8511
ISSN
1094-4087 (ISSN-L)
OpenAlex
W2605002306
Cited by
53
References
5
Citations by year
2026: 2 · 2024: 4 · 2023: 5 · 2022: 7 · 2021: 6 · 2020: 9 · 2019: 5 · 2018: 10 · 2017: 5
FWCI
3.89
Type
journal article
Language
en
Open access
Locations
  • Optics Express (publishedVersion)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
Funders
  • Japan Society for the Promotion of Science (JSPS)
  • MAEDI
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
Keywords
optical frequency measurement, SI traceability, frequency metrology, cesium fountain, primary frequency standard

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review