The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Pulse-length dependence of cellular response to intense near-infrared laser pulses in multiphoton microscopes
Abstract
The influence of the pulse length, tau , of ultrashort laser pulses at 780 and 920 nm on cell vitality and cellular reproduction has been studied. A total of 2400 nonlabeled cells were exposed to a highly focused scanning beam from a mode-locked 80-MHz Ti:sapphire laser with 60-micros pixel dwell time. For the same pulse energy, destructive effects were more pronounced for shorter pulses. The damage behavior was found to follow approximately a P(2)/tau dependence (P , mean power), indicating that cell destruction is likely based on a two-photon excitation process rather than a one- or a three-photon event. Therefore, femtosecond as well as picosecond pulses provide approximately the same relative optical window for safe two-photon fluorescence microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy.
Xu, C., Zipfel, W., Shear, J. B., Williams, R. M., & Webb, W. W. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.20.10763 · Cited by 1,165
Measuring Serotonin Distribution in Live Cells with Three-Photon Excitation
Maiti, S., Shear, J. B., Williams, R. M., Zipfel, W. R., & Webb, W. W. (1997) · Science · doi:10.1126/science.275.5299.530 · Cited by 417
Evidence for localized cell heating induced by infrared optical tweezers
Liu, Y., Cheng, D. K., Sonek, G. J., Berns, M. W., Chapman, C. F., & Tromberg, B. J. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80396-6 · Cited by 325
Cellular response to near-infrared femtosecond laser pulses in two-photon microscopes
König, K., So, P. T. C., Mantulin, W. W., & Gratton, E. (1997) · Optics Letters · doi:10.1364/ol.22.000135 · Cited by 254
Self-citationThree-photon excitation in fluorescence microscopy
Hell, S. W. (1996) · Journal of Biomedical Optics · doi:10.1117/12.229062 · Cited by 214
Two‐photon excited lifetime imaging of autofluorescence in cells during UV A and NIR photostress
KÖNIG, K., SO, P. T. C., MANTULIN, W. W., TROMBERG, B. J., & GRATTON, E. (1996) · Journal of Microscopy · doi:10.1046/j.1365-2818.1996.910650.x · Cited by 209
Self-citationHeating by absorption in the focus of an objective lens
Schönle, A., & Hell, S. W. (1998) · Optics Letters · doi:10.1364/ol.23.000325 · Cited by 191
Cell damage by near-IR microbeams
König, K., Liang, H., Berns, M. W., & Tromberg, B. J. (1995) · Nature · doi:10.1038/377020a0 · Cited by 170
Self-citationCell damage in near-infrared multimode optical traps as a result of multiphoton absorption
König, K., Liang, H., Berns, M. W., & Tromberg, B. J. (1996) · Optics Letters · doi:10.1364/ol.21.001090 · Cited by 158
Self-citationCunningham, M. L., Johnson, J. S., Giovanazzi, S. M., & Peak, M. J. (1985) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1985.tb01549.x · Cited by 139
Two-photon near- and far-field fluorescence microscopy with continuous-wave excitation
Hell, S. W., Booth, M. J., Wilms, S., Schnetter, C., Kirsch, A. K., Arndt‐Jovin, D. J., & Jovin, T. M. (1998) · Optics Letters · doi:10.1364/ol.23.001238 · Cited by 91
Booth, & Hell, S. W. (1998) · Journal of Microscopy · doi:10.1046/j.1365-2818.1998.00375.x · Cited by 46
Picosecond pulsed two‐photon imaging with repetition rates of 200 and 400 MHz
Bewersdorf, & Hell, S. W. (1998) · Journal of Microscopy · doi:10.1046/j.1365-2818.1998.00379.x · Cited by 45
Gu, M., & Gan, X. (1996) · Bioimaging · doi:10.1002/1361-6374(199609)4:3<208::aid-bio11>3.0.co;2-j · Cited by 13
Cited by
Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869
Mechanisms of femtosecond laser nanosurgery of cells and tissues
Vogel, A., Noack, J., Hüttman, G., & Paltauf, G. (2005) · Applied Physics B · doi:10.1007/s00340-005-2036-6 · Cited by 1,408
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
Self-citationTwo-Photon Excitation Fluorescence Microscopy
So, P. T. C., Dong, C. Y., Masters, B. R., & Berland, K. M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.399 · Cited by 1,057
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Metadata
- Authors
- König, K., Becker, T. W., Fischer, P., Riemann, I., & Halbhuber, K.-J.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1999-01-15
- Volume
- 24
- Issue
- 2
- Pages
- 113
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2040815295
- Cited by
- 259
- References
- 15
- FWCI
- 10.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.