The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography
Open accessAbstract
We present the first ultrahigh-resolution optical coherence tomography (OCT) structural intensity images and movies of the human retina in vivo at 29.3 frames per second with 500 A-lines per frame. Data was acquired at a continuous rate of 29,300 spectra per second with a 98% duty cycle. Two consecutive spectra were coherently summed to improve sensitivity, resulting in an effective rate of 14,600 A-lines per second at an effective integration time of 68 micros. The turn-key source was a combination of two super luminescent diodes with a combined spectral width of more than 150 nm providing 4.5 mW of power. The spectrometer of the spectraldomain OCT (SD-OCT) setup was centered around 885 nm with a bandwidth of 145 nm. The effective bandwidth in the eye was limited to approximately 100 nm due to increased absorption of wavelengths above 920 nm in the vitreous. Comparing the performance of our ultrahighresolution SD-OCT system with a conventional high-resolution time domain OCT system, the A-line rate of the spectral-domain OCT system was 59 times higher at a 5.4 dB lower sensitivity. With use of a software based dispersion compensation scheme, coherence length broadening due to dispersion mismatch between sample and reference arms was minimized. The coherence length measured from a mirror in air was equal to 4.0 microm (n= 1). The coherence length determined from the specular reflection of the foveal umbo in vivo in a healthy human eye was equal to 3.5 microm (n = 1.38). With this new system, two layers at the location of the retinal pigmented epithelium seem to be present, as well as small features in the inner and outer plexiform layers, which are believed to be small blood vessels. ?2004 Optical Society of America.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,794
Optical and retinal factors affecting visual resolution.
Campbell, F. W., & Green, D. G. (1965) · The Journal of Physiology · doi:10.1113/jphysiol.1965.sp007784 · Cited by 1,595
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,250
Self-citationMeasurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
In vivo ultrahigh-resolution optical coherence tomography
Drexler, W., Morgner, U., Käertner, F. X., Pitris, C., Boppart, S. A., Li, X. D., Ippen, E. P., & Fujimoto, J. G. (1999) · Optics Letters · doi:10.1364/ol.24.001221 · Cited by 945
In vivo human retinal imaging by Fourier domain optical coherence tomography
Wojtkowski, M., Leitgeb, R., Kowalczyk, A., Bajraszewski, T., & Fercher, A. F. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1482379 · Cited by 913
In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography
Nassif, N., Cense, B., Hyle Park, B., Yun, S. H., Chen, T. C., Bouma, B. E., Tearney, G. J., & de Boer, J. F. (2004) · Optics Letters · doi:10.1364/ol.29.000480 · Cited by 498
Self-citationDrexler, W. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.5.695 · Cited by 467
White, B. R., Pierce, M. C., Nassif, N., Cense, B., Park, B. H., Tearney, G. J., Bouma, B. E., Chen, T. C., & de Boer, J. F. (2003) · Optics Express · doi:10.1364/oe.11.003490 · Cited by 457
Self-citationHigh-speed phase- and group-delay scanning with a grating-based phase control delay line
Tearney, G. J., Bouma, B. E., & Fujimoto, J. G. (1997) · Optics Letters · doi:10.1364/ol.22.001811 · Cited by 449
Self-citationHigh-speed spectral-domain optical coherence tomography at 13 μm wavelength
Yun, S., Tearney, G., Bouma, B., Park, B., & de Boer, J. (2003) · Optics Express · doi:10.1364/oe.11.003598 · Cited by 399
Self-citationNeural-vascular relationships in central retina of macaque monkeys (Macaca fascicularis)
Snodderly, D., Weinhaus, R., & Choi, J. (1992) · The Journal of Neuroscience · doi:10.1523/jneurosci.12-04-01169.1992 · Cited by 334
Cense, B., Chen, T. C., Park, B. H., Pierce, M. C., & de Boer, J. F. (2002) · Optics Letters · doi:10.1364/ol.27.001610 · Cited by 182
Self-citationMarks, D. L., Oldenburg, A. L., Reynolds, J. J., & Boppart, S. A. (2003) · Applied Optics · doi:10.1364/ao.42.000204 · Cited by 93
Stable carrier generation and phase-resolved digital data processing in optical coherence tomography
de Boer, J. F., Saxer, C. E., & Nelson, J. S. (2001) · Applied Optics · doi:10.1364/ao.40.005787 · Cited by 72
Dispersion compensation for optical coherence tomography depth-scan signals by a numerical technique
FERCHER, A. F., Hitzenberger, C. K. F., Sticker, M., Zawadzki, R. J., Karamata, B., & Lasser, T. (2002) · Optics Communications · doi:10.1016/s0030-4018(02)01137-9 · Cited by 67
Cited by
Imaging and Photodynamic Therapy: Mechanisms, Monitoring, and Optimization
Celli, J. P., Spring, B. Q., Rizvi, I., Evans, C. L., Samkoe, K. S., Verma, S., Pogue, B. W., & Hasan, T. (2010) · Chemical Reviews · doi:10.1021/cr900300p · Cited by 2,324
Kashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Optical coherence tomography in multiple sclerosis: a systematic review and meta-analysis
Petzold, A., de Boer, J. F., Schippling, S., Vermersch, P., Kardon, R., Green, A., Calabresi, P. A., & Polman, C. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70168-x · Cited by 596
Self-citationThe Development, Commercialization, and Impact of Optical Coherence Tomography
Fujimoto, J., & Swanson, E. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19963 · Cited by 472
Metadata
- Authors
- Cense, B., Nassif, N. A., Chen, T. C., Pierce, M. C., Yun, S.-H., Park, B. H., Bouma, B. E., Tearney, G. J., & de Boer, J. F.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2004-05-31
- Volume
- 12
- Issue
- 11
- Pages
- 2435
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2096412116
- Cited by
- 468
- References
- 20
- FWCI
- 23.97
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.