The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
X-ray phase imaging with a grating interferometer
Open accessAbstract
Using a high-efficiency grating interferometer for hard X rays (10-30 keV) and a phase-stepping technique, separate radiographs of the phase and absorption profiles of bulk samples can be obtained from a single set of measurements. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index, with a spatial resolution down to a few microns. The method is mechanically robust, requires little spatial coherence and monochromaticity, and can be scaled up to large fields of view, with a detector of correspondingly moderate spatial resolution. These are important prerequisites for use with laboratory X-ray sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase-contrast imaging using polychromatic hard X-rays
Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A., & Stevenson, A. W. (1996) · Nature · doi:10.1038/384335a0 · Cited by 1,766
Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S., & Schelokov, I. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146073 · Cited by 1,493
Cloetens, P., Ludwig, W., Baruchel, J., Van Dyck, D., Van Landuyt, J., Guigay, J. P., & Schlenker, M. (1999) · Applied Physics Letters · doi:10.1063/1.125225 · Cited by 1,078
Self-citationPhase-contrast imaging of weakly absorbing materials using hard X-rays
Davis, T. J., Gao, D., Gureyev, T. E., Stevenson, A. W., & Wilkins, S. W. (1995) · Nature · doi:10.1038/373595a0 · Cited by 1,010
Phase–contrast X–ray computed tomography for observing biological soft tissues
Momose, A., Takeda, T., Itai, Y., & Hirano, K. (1996) · Nature Medicine · doi:10.1038/nm0496-473 · Cited by 850
Fitzgerald, R. (2000) · Physics Today · doi:10.1063/1.1292471 · Cited by 555
X-ray plane-wave topography observation of the phase contrast from a non-crystalline object
Ingal, V. N., & Beliaevskaya, E. A. (1995) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/28/11/012 · Cited by 411
Phase-sensitive imaging and phase tomography using X-ray interferometers
Momose, A. (2003) · Optics Express · doi:10.1364/oe.11.002303 · Cited by 276
Cited by
Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
Pfeiffer, F., Weitkamp, T., Bunk, O., & David, C. (2006) · Nature Physics · doi:10.1038/nphys265 · Cited by 1,855
Self-citationMaire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
X-ray phase-contrast imaging: from pre-clinical applications towards clinics
Bravin, A., Coan, P., & Suortti, P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/1/r1 · Cited by 846
X-ray computed tomography of polymer composites
Garcea, S. C., Wang, Y., & Withers, P. J. (2018) · Composites Science and Technology · doi:10.1016/j.compscitech.2017.10.023 · Cited by 719
Stripe and ring artifact removal with combined wavelet—Fourier filtering
Münch, B., Trtik, P., Marone, F., & Stampanoni, M. (2009) · Optics Express · doi:10.1364/oe.17.008567 · Cited by 681
Self-citationX-Rays and Extreme Ultraviolet Radiation: Principles and Applications
Attwood, D., & Sakdinawat, A. (2016) · CERN Document Server (European Organization for Nuclear Research) · doi:10.1017/cbo9781107477629 · Cited by 644
Willemink, M. J., & Noël, P. B. (2019) · European Radiology · doi:10.1007/s00330-018-5810-7 · Cited by 603
Recent advances in X-ray microtomography applied to materials
Stock, S. R. (2008) · International Materials Reviews · doi:10.1179/174328008x277803 · Cited by 517
Trends in synchrotron-based tomographic imaging: the SLS experience
Stampanoni, M., Groso, A., Isenegger, A., Mikuljan, G., Chen, Q., Bertrand, A., Henein, S., Betemps, R., Frommherz, U., Böhler, P., et al. (2006) · SPIE Proceedings · doi:10.1117/12.679497 · Cited by 304
Self-citationDevelopment of phase-contrast X-ray imaging techniques and potential medical applications
Zhou, S.-A., & Brahme, A. (2008) · Physica Medica · doi:10.1016/j.ejmp.2008.05.006 · Cited by 268
A review of X-ray explosives detection techniques for checked baggage
Wells, K., & Bradley, D. A. (2012) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2012.01.011 · Cited by 259
Stampanoni, M., Wang, Z., Thüring, T., David, C., Roessl, E., Trippel, M., Kubik-Huch, R. A., Singer, G., Hohl, M. K., & Hauser, N. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e31822a585f · Cited by 254
Self-citationDense neuronal reconstruction through X-ray holographic nano-tomography
Kuan, A. T., Phelps, J. S., Thomas, L. A., Nguyen, T. M., Han, J., Chen, C.-L., Azevedo, A. W., Tuthill, J. C., Funke, J., Cloetens, P., et al. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-0704-9 · Cited by 160
Self-citationFast 3D reconstruction method for differential phase contrast X-ray CT
McCann, M. T., Nilchian, M., Stampanoni, M., & Unser, M. (2016) · Optics Express · doi:10.1364/oe.24.014564 · Cited by 28
Self-citation
Metadata
- Authors
- Weitkamp, T., Diaz, A., David, C., Pfeiffer, F., Stampanoni, M., Cloetens, P., & Ziegler, E.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2005-08-08
- Volume
- 13
- Issue
- 16
- Pages
- 6296
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2084265296
- Cited by
- 1,211
- References
- 8
- FWCI
- 21.43
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.