The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Computational illumination for high-speed in vitro Fourier ptychographic microscopy
Open accessAbstract
We demonstrate a new computational illumination technique that achieves large space-bandwidth-time product, for quantitative phase imaging of unstained live samples in vitro. Microscope lenses can have either large field of view (FOV) or high resolution, not both. Fourier ptychographic microscopy (FPM) is a new computational imaging technique that circumvents this limit by fusing information from multiple images taken with different illumination angles. The result is a gigapixel-scale image having both wide FOV and high resolution, i.e. large space-bandwidth product (SBP). FPM has enormous potential for revolutionizing microscopy and has already found application in digital pathology. However, it suffers from long acquisition times (on the order of minutes), limiting throughput. Faster capture times would not only improve imaging speed, but also allow studies of live samples, where motion artifacts degrade results. In contrast to fixed (e.g. pathology) slides, live samples are continuously evolving at various spatial and temporal scales. Here, we present a new source coding scheme, along with real-time hardware control, to achieve 0.8 NA resolution across a 4x FOV with sub-second capture times. We propose an improved algorithm and new initialization scheme, which allow robust phase reconstruction over long time-lapse experiments. We present the first FPM results for both growing and confluent in vitro cell cultures, capturing videos of subcellular dynamical phenomena in popular cell lines undergoing division and migration. Our method opens up FPM to applications with live samples, for observing rare events in both space and time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596
CellProfiler: image analysis software for identifying and quantifying cell phenotypes
Carpenter, A. E., Jones, T. R., Lamprecht, M. R., Clarke, C., Kang, I. H., Friman, O., Guertin, D. A., Chang, J. H., Lindquist, R. A., Moffat, J., et al. (2006) · Genome Biology · doi:10.1186/gb-2006-7-10-r100 · Cited by 5,157
Gustafsson, M. G. L. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00710.x · Cited by 3,786
Wide-field, high-resolution Fourier ptychographic microscopy
Zheng, G., Horstmeyer, R., & Yang, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.187 · Cited by 1,829
Boyd, M. R., & Paull, K. D. (1995) · Drug Development Research · doi:10.1002/ddr.430340203 · Cited by 1,572
An improved ptychographical phase retrieval algorithm for diffractive imaging
Maiden, A. M., & Rodenburg, J. M. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2009.05.012 · Cited by 1,496
Serial time-encoded amplified imaging for real-time observation of fast dynamic phenomena
Goda, K., Tsia, K. K., & Jalali, B. (2009) · Nature · doi:10.1038/nature07980 · Cited by 763
Probe retrieval in ptychographic coherent diffractive imaging
Thibault, P., Dierolf, M., Bunk, O., Menzel, A., & Pfeiffer, F. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2008.12.011 · Cited by 717
Multiplexed coded illumination for Fourier Ptychography with an LED array microscope
Tian, L., Li, X., Ramchandran, K., & Waller, L. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002376 · Cited by 584
Self-citationImaging without lenses: achievements and remaining challenges of wide-field on-chip microscopy
Greenbaum, A., Luo, W., Su, T.-W., Göröcs, Z., Xue, L., Isikman, S. O., Coskun, A. F., Mudanyali, O., & Ozcan, A. (2012) · Nature Methods · doi:10.1038/nmeth.2114 · Cited by 540
Phase-retrieval stagnation problems and solutions
Fienup, J. R., & Wackerman, C. C. (1986) · Journal of the Optical Society of America A · doi:10.1364/josaa.3.001897 · Cited by 538
Phase retrieval with transverse translation diversity: a nonlinear optimization approach
Guizar-Sicairos, M., & Fienup, J. R. (2008) · Optics Express · doi:10.1364/oe.16.007264 · Cited by 525
Optical imaging of cell mass and growth dynamics
Popescu, G., Park, Y., Lue, N., Best-Popescu, C., Deflores, L., Dasari, R. R., Feld, M. S., & Badizadegan, K. (2008) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00121.2008 · Cited by 518
Embedded pupil function recovery for Fourier ptychographic microscopy
Ou, X., Zheng, G., & Yang, C. (2014) · Optics Express · doi:10.1364/oe.22.004960 · Cited by 443
Interference Microscopy and Mass Determination
BARER, R. (1952) · Nature · doi:10.1038/169366b0 · Cited by 433
Optical measurement of cycle-dependent cell growth
Mir, M., Wang, Z., Shen, Z., Bednarz, M., Bashir, R., Golding, I., Prasanth, S. G., & Popescu, G. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1100506108 · Cited by 409
Quantitative differential phase contrast imaging in an LED array microscope
Tian, L., & Waller, L. (2015) · Optics Express · doi:10.1364/oe.23.011394 · Cited by 392
Self-citationOptical Systems with Resolving Powers Exceeding the Classical Limit*
Lukosz, W. (1966) · Journal of the Optical Society of America · doi:10.1364/josa.56.001463 · Cited by 362
Cellular imaging in drug discovery
Lang, P., Yeow, K., Nichols, A., & Scheer, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2008 · Cited by 351
Optical Systems with Resolving Powers Exceeding the Classical Limit II
Lukosz, W. (1967) · Journal of the Optical Society of America · doi:10.1364/josa.57.000932 · Cited by 331
Influence of the overlap parameter on the convergence of the ptychographical iterative engine
Bunk, O., Dierolf, M., Kynde, S., Johnson, I., Marti, O., & Pfeiffer, F. (2008) · Ultramicroscopy · doi:10.1016/j.ultramic.2007.08.003 · Cited by 307
Wide-field computational imaging of pathology slides using lens-free on-chip microscopy
Greenbaum, A., Zhang, Y., Feizi, A., Chung, P.-L., Luo, W., Kandukuri, S. R., & Ozcan, A. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3009850 · Cited by 294
Synthetic aperture-based on-chip microscopy
Luo, W., Greenbaum, A., Zhang, Y., & Ozcan, A. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.34 · Cited by 257
Mehta, S. B., & Sheppard, C. J. R. (2009) · Optics Letters · doi:10.1364/ol.34.001924 · Cited by 220
Zheng, G., Lee, S. A., Antebi, Y., Elowitz, M. B., & Yang, C. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1110681108 · Cited by 209
Quantitative phase‐amplitude microscopy I: optical microscopy
Barone‐Nugent, E. D., Barty, A., & Nugent, K. A. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01027.x · Cited by 190
Continuous live imaging of adult neural stem cell division and lineage progression in vitro
Costa, M. R., Ortega, F., Brill, M. S., Beckervordersandforth, R., Petrone, C., Schroeder, T., Götz, M., & Berninger, B. (2011) · Development · doi:10.1242/dev.061663 · Cited by 159
Computational prediction of neural progenitor cell fates
Cohen, A. R., Gomes, F. L. A. F., Roysam, B., & Cayouette, M. (2010) · Nature Methods · doi:10.1038/nmeth.1424 · Cited by 111
Multi-Contrast Imaging and Digital Refocusing on a Mobile Microscope with a Domed LED Array
Phillips, Z. F., D’Ambrosio, M. V., Tian, L., Rulison, J. J., Patel, H. S., Sadras, N., Gande, A. V., Switz, N. A., Fletcher, D. A., & Waller, L. (2015) · PLoS ONE · doi:10.1371/journal.pone.0124938 · Cited by 104
Self-citationResolving a misconception about structured illumination
Wicker, K., & Heintzmann, R. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.88 · Cited by 99
Microscopy with microlens arrays: high throughput, high resolution and light-field imaging
Orth, A., & Crozier, K. B. (2012) · Optics Express · doi:10.1364/oe.20.013522 · Cited by 87
Artifact Halo Reduction in Phase Contrast Microscopy Using Apodization
Otaki, T. (2000) · Optical Review · doi:10.1007/s10043-000-0119-5 · Cited by 53
Getting the whole picture: combining throughput with content in microscopy
Rimon, N., & Schuldiner, M. (2011) · Journal of Cell Science · doi:10.1242/jcs.087486 · Cited by 46
Cited by
Concept, implementations and applications of Fourier ptychography
Zheng, G., Shen, C., Jiang, S., Song, P., & Yang, C. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00280-y · Cited by 416
Experimental robustness of Fourier ptychography phase retrieval algorithms
Yeh, L.-H., Dong, J., Zhong, J., Tian, L., Chen, M., Tang, G., Soltanolkotabi, M., & Waller, L. (2015) · Optics Express · doi:10.1364/oe.23.033214 · Cited by 320
Self-citationQuantitative Phase Imaging: Recent Advances and Expanding Potential in Biomedicine
Nguyen, T. L., Pradeep, S., Judson-Torres, R. L., Reed, J., Teitell, M. A., & Zangle, T. A. (2022) · ACS Nano · doi:10.1021/acsnano.1c11507 · Cited by 318
Quantitative phase imaging based on holography: trends and new perspectives
Huang, Z., & Cao, L. (2024) · Light: Science & Applications · doi:10.1038/s41377-024-01453-x · Cited by 277
Deep learning approach for Fourier ptychography microscopy
Nguyen, T., Xue, Y., Li, Y., Tian, L., & Nehmetallah, G. (2018) · Optics Express · doi:10.1364/oe.26.026470 · Cited by 261
Self-citation
Metadata
- Authors
- Tian, L., Liu, Z., Yeh, L.-H., Chen, M., Zhong, J., & Waller, L.
- Venue
- Optica
- Publisher
- Optica Publishing Group
- Published
- 2015-10-14
- Volume
- 2
- Issue
- 10
- Pages
- 904
- ISSN
- 2334-2536 (ISSN-L)
- OpenAlex
- W2261975831
- Cited by
- 317
- References
- 34
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.