Single-branch Er:fiber frequency comb for precision optical metrology with 10^−18 fractional instability
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
The comparison of optical atomic clocks with frequency instabilities reaching 1 part in 1016 at 1 s will enable more stringent tests of fundamental physics. These comparisons, mediated by optical frequency combs, require optical synthesis and measurement with a performance better than, or comparable to, the best optical clocks. Fiber-based mode-locked lasers have shown great potential for compact, robust, and efficient optical clockwork but typically require multiple amplifier and fiber optic paths that limit the achievable fractional frequency stability near 1 part in 1016 at 1 s. Here we describe an erbium-fiber laser frequency comb that overcomes these conventional challenges by ensuring that all critical fiber paths are common mode and within the servo-controlled feedback loop. Using this architecture, we demonstrate a fractional optical measurement uncertainty below 1×10−19 and fractional frequency instabilities less than 3×10−18 at 1 s and 1×10−19 at 1000 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Self-citationAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Takamoto, M., Hong, F.-L., Higashi, R., & Katori, H. (2005) · Nature · doi:10.1038/nature03541 · Cited by 853
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Self-citationSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Ma, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566
Hunting for topological dark matter with atomic clocks
Derevianko, A., & Pospelov, M. (2014) · Nature Physics · doi:10.1038/nphys3137 · Cited by 522
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
New Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431
Remote transfer of ultrastable frequency references via fiber networks
Foreman, S. M., Holman, K. W., Hudson, D. D., Jones, D. J., & Ye, J. (2007) · Review of Scientific Instruments · doi:10.1063/1.2437069 · Cited by 403
Gravitational wave detection with optical lattice atomic clocks
Kolkowitz, S., Pikovski, I., Langellier, N., Lukin, M. D., Walsworth, R. L., & Ye, J. (2016) · Physical Review D · doi:10.1103/physrevd.94.124043 · Cited by 396
Ultrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
Self-citationOptical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A. (2004) · Science · doi:10.1126/science.1095092 · Cited by 319
Self-citationOptical-Frequency Transfer over a Single-Span 1840 km Fiber Link
Droste, S., Ozimek, F., Udem, T., Predehl, K., Hänsch, T. W., Schnatz, H., Grosche, G., & Holzwarth, R. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.110801 · Cited by 315
Fortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Self-citation
Cited by
20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Self-citationFrequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
Self-citationEnd-to-end topology for fiber comb based optical frequency transfer at the 10 −21 level
Benkler, E., Lipphardt, B., Puppe, T., Wilk, R., Rohde, F., & Sterr, U. (2019) · Optics Express · doi:10.1364/oe.27.036886 · Cited by 51
“The broadband comb either originates from a single branch of the comb generation system [22–26] or is generated in two distinct branches which are actively stabilized to each other [27].”
BackgroundReal-time phase tracking for wide-band optical frequency measurements at the 20th decimal place
Giunta, M., Hänsel, W., Fischer, M., Lezius, M., Udem, T., & Holzwarth, R. (2020) · Nature Photonics · doi:10.1038/s41566-019-0520-5 · Cited by 41
Barbieri, P., Clivati, C., Pizzocaro, M., Levi, F., & Calonico, D. (2019) · Metrologia · doi:10.1088/1681-7575/ab2b0f · Cited by 18
“Even if single-branch combs achieve better performances [15, 16], a multibranch configuration offers higher powerper-mode in different spectral regions, which simplifies the measurement setup.”
Background
Metadata
- Authors
- Leopardi, H., Davila-Rodriguez, J., Quinlan, F., Olson, J., Sherman, J. A., Diddams, S. A., & Fortier, T. M.
- Venue
- Optica
- Publisher
- Optica Publishing Group
- Published
- 2017-07-27
- Volume
- 4
- Issue
- 8
- Pages
- 879
- ISSN
- 2334-2536 (ISSN-L)
- OpenAlex
- W2738522074
- Cited by
- 104
- References
- 16
- FWCI
- 5.53
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.