Visual BOLD Response in Late Blind Subjects with Argus II Retinal Prosthesis
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Retinal prosthesis technologies require that the visual system downstream of the retinal circuitry be capable of transmitting and elaborating visual signals. We studied the capability of plastic remodeling in late blind subjects implanted with the Argus II Retinal Prosthesis with psychophysics and functional MRI (fMRI). After surgery, six out of seven retinitis pigmentosa (RP) blind subjects were able to detect high-contrast stimuli using the prosthetic implant. However, direction discrimination to contrast modulated stimuli remained at chance level in all of them. No subject showed any improvement of contrast sensitivity in either eye when not using the Argus II. Before the implant, the Blood Oxygenation Level Dependent (BOLD) activity in V1 and the lateral geniculate nucleus (LGN) was very weak or absent. Surprisingly, after prolonged use of Argus II, BOLD responses to visual input were enhanced. This is, to our knowledge, the first study tracking the neural changes of visual areas in patients after retinal implant, revealing a capacity to respond to restored visual input even after years of deprivation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural reorganization following sensory loss: the opportunity of change
Merabet, L. B., & Pascual-Leone, A. (2010) · Nature Reviews Neuroscience · doi:10.1038/nrn2758 · Cited by 751 · cited 1×
“Cross-modal plasticity [15–18], known to occur also in late blind subjects [19], may raise an additional obstacle to reactivate cortical responses to the restored input [20,21].”
BackgroundInterim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700 · cited 1×
“We also performed the Square Localization test, used previously with Argus II patients [10,27].”
MethodArtificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473 · cited 1×
“At present, two devices have been approved as commercial products with clinical trials: the subretinal visual implants Alpha IMS (Retina Implant AG, Reutlingen, Germany, see [8,9]), which induce excitation of the internal plexiform layer, and the Argus II implants (Second Sight, Sylmar, CA, see [10–12]), which induce…”
MethodShape conveyed by visual-to-auditory sensory substitution activates the lateral occipital complex
Amedi, A., Stern, W. M., Camprodon, J. A., Bermpohl, F., Merabet, L., Rotman, S., Hemond, C., Meijer, P., & Pascual-Leone, A. (2007) · Nature Neuroscience · doi:10.1038/nn1912 · Cited by 451
Subretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387 · cited 1×
“At present, two devices have been approved as commercial products with clinical trials: the subretinal visual implants Alpha IMS (Retina Implant AG, Reutlingen, Germany, see [8,9]), which induce excitation of the internal plexiform layer, and the Argus II implants (Second Sight, Sylmar, CA, see [10–12]), which induce…”
Methodda Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359 · cited 1×
“Our data show that the training with Argus II transfers to more subtle improvements than previously observed [30], including the detection of sinusoidal gratings that the patients never saw before and, importantly, that are not associated with overall mean luminance changes.”
ResultThe Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
A ventral visual stream reading center independent of visual experience
Reich, L., Szwed, M., Cohen, L., & Amedi, A. (2011) · Current Biology · doi:10.1016/j.cub.2011.01.040 · Cited by 295
Lewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228
The Retinotopic Organization of Striate Cortex Is Well Predicted by Surface Topology
Benson, N. C., Butt, O. H., Datta, R., Radoeva, P. D., Brainard, D. H., & Aguirre, G. K. (2012) · Current Biology · doi:10.1016/j.cub.2012.09.014 · Cited by 227
Cited by
Photovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration
Palanker, D., Le Mer, Y., Mohand-Said, S., Muqit, M., & Sahel, J. A. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2020.02.024 · Cited by 227
Cooperation, competition and antibiotic resistance in bacterial colonies
Frost, I., Smith, W. P. J., Mitri, S., Millan, A. S., Davit, Y., Osborne, J. M., Pitt-Francis, J. M., MacLean, R. C., & Foster, K. R. (2018) · The ISME Journal · doi:10.1038/s41396-018-0090-4 · Cited by 204
Simultaneous perception of prosthetic and natural vision in AMD patients
Palanker, D., Le Mer, Y., Mohand-Said, S., & Sahel, J. A. (2022) · Nature Communications · doi:10.1038/s41467-022-28125-x · Cited by 140
Beyeler, M., Rokem, A., Boynton, G. M., & Fine, I. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa795e · Cited by 102
Against Hybridism: Why We Need to Distinguish between Nature and Society, Now More than Ever
Malm, A. (2019) · Historical Materialism · doi:10.1163/1569206x-00001610 · Cited by 68
Vignal-Clermont, C., Girmens, J.-F., Audo, I., Said, S. M., Errera, M.-H., Plaine, L., O’Shaughnessy, D., Taiel, M., & Sahel, J.-A. (2021) · BioDrugs · doi:10.1007/s40259-021-00468-9 · Cited by 51
“Finally, brain plasticity could account for an effect on visual function in the contralateral eye, as was shown for blind subjects implanted with retinal prosthesis [33].”
BackgroundBrain-Machine Interfaces to Assist the Blind
Ptito, M., Bleau, M., Djerourou, I., Paré, S., Schneider, F. C., & Chebat, D.-R. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.638887 · Cited by 45
Biodistribution of intravitreal lenadogene nolparvovec gene therapy in nonhuman primates
Calkins, D. J., Yu-Wai-Man, P., Newman, N. J., Taiel, M., Singh, P., Chalmey, C., Rogue, A., Carelli, V., Ancian, P., & Sahel, J. A. (2021) · Molecular Therapy - Methods & Clinical Development · doi:10.1016/j.omtm.2021.09.013 · Cited by 37
Advances in neuroscience, not devices, will determine the effectiveness of visual prostheses
Abbasi, B., & Rizzo, J. F. (2021) · Seminars in Ophthalmology · doi:10.1080/08820538.2021.1887902 · Cited by 19
Metadata
- Authors
- Castaldi, E., Cicchini, G. M., Cinelli, L., Biagi, L., Rizzo, S., & Morrone, M. C.
- Venue
- PLOS Biology
- Publisher
- Public Library of Science (PLoS)
- Published
- 2016-10-25
- Volume
- 14
- Issue
- 10
- Pages
- e1002569
- ISSN
- 1544-9173 (ISSN-L)
- 1545-7885
- OpenAlex
- W2534549821
- Cited by
- 68
- References
- 16
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.