Simulation of the Undiseased Human Cardiac Ventricular Action Potential: Model Formulation and Experimental Validation
Open accessThe DOI matches its Crossref record; 110 of the 110 references it cites were found in a registry or an index.
Abstract
Cellular electrophysiology experiments, important for understanding cardiac arrhythmia mechanisms, are usually performed with channels expressed in non myocytes, or with non-human myocytes. Differences between cell types and species affect results. Thus, an accurate model for the undiseased human ventricular action potential (AP) which reproduces a broad range of physiological behaviors is needed. Such a model requires extensive experimental data, but essential elements have been unavailable. Here, we develop a human ventricular AP model using new undiseased human ventricular data: Ca(2+) versus voltage dependent inactivation of L-type Ca(2+) current (I(CaL)); kinetics for the transient outward, rapid delayed rectifier (I(Kr)), Na(+)/Ca(2+) exchange (I(NaCa)), and inward rectifier currents; AP recordings at all physiological cycle lengths; and rate dependence and restitution of AP duration (APD) with and without a variety of specific channel blockers. Simulated APs reproduced the experimental AP morphology, APD rate dependence, and restitution. Using undiseased human mRNA and protein data, models for different transmural cell types were developed. Experiments for rate dependence of Ca(2+) (including peak and decay) and intracellular sodium ([Na(+)](i)) in undiseased human myocytes were quantitatively reproduced by the model. Early afterdepolarizations were induced by I(Kr) block during slow pacing, and AP and Ca(2+) alternans appeared at rates >200 bpm, as observed in the nonfailing human ventricle. Ca(2+)/calmodulin-dependent protein kinase II (CaMK) modulated rate dependence of Ca(2+) cycling. I(NaCa) linked Ca(2+) alternation to AP alternans. CaMK suppression or SERCA upregulation eliminated alternans. Steady state APD rate dependence was caused primarily by changes in [Na(+)](i), via its modulation of the electrogenic Na(+)/K(+) ATPase current. At fast pacing rates, late Na(+) current and I(CaL) were also contributors. APD shortening during restitution was primarily dependent on reduced late Na(+) and I(CaL) currents due to inactivation at short diastolic intervals, with additional contribution from elevated I(Kr) due to incomplete deactivation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 1 Undiseased human ICaL experiments and model validation. A) Experiments: ICaL traces for currents carried by Ca2+ (top), Ba2+ (middle), and Sr2+ (bottom). The voltage protocol is below the Ca2+ traces. Ca2+ current decay was visibly more rapid than decay for Ba2+ or Sr2+ currents. Simulations: ICaL in response to the same voltage protocol with CDI (CDI+VDI, top), and without CDI (VDI-only, bottom). B) Experimental data are on the left (white circles, N = 5, from 3 hearts). Simulation results are on the right (solid lines). FRC is fractional remaining current. Times after peak current shown are from 5 to 55 ms, in 5 ms steps (indicated by arrow). Top left) Experiments showing the voltage and time dependence of FRC with Ba2+ as charge carrier (VDI only). Top right) Simulations of FRC, with n−gate = 0 (representing VDI only; see text and panel E). Bottom left) Experiments showing FRC with Ca2+ as charge carrier (CDI and VDI are concurrent). FRC for CDI+VDI was significantly smaller at more hyperpolarized potentials (Vm = −20 to 0 mV, dashed box) than FRC for VDI-alone. Bottom right) Simulations of FRC with free running n gate, allowing both CDI and VDI to occur. C) Data are from Magyar et al.[11] (black squares), Fulop et al.[12] (black diamonds), and previously unpublished (white circles, N = 5, from 3 hearts). Simulation results are solid lines. From left to right, top to bottom: steady state activation, steady state inactivation, fast time constant for VDI, slow time constant for VDI, relative weight of the fast component for VDI, I–V curve, experiments showing recovery from inactivation, and corresponding simulations. D) Human AP clamp waveform, used to elicit 1 µM nisoldipine sensitive current (ICaL, experiments, left) and comparison to simulations using the same AP clamp (right). E) Schematic diagram for the n gate, representing the fraction of L-type channels undergoing CDI. Calmodulin (CaM) is constitutively attached to the L-type channel. Ca2+ ions bind to CaM (on-rate k1 and off-rate k-1). With Ca2+ ions bound, the Ca2+/CaM/channel complex may activate CDI mode (asterisk and black color indicate CDI activation, on-rate k2 and off-rate k-2).](https://figures.cochat.ai/paper-figures/77154b4d77164fafa05b6b606a19318d/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-1.jpg)
![Figure 2 Undiseased human Ito, INaCa, and IK1 experiments and model validation. A) Ito. Experimental data are white circles (N = 8 from 5 hearts for inactivation time constants, N = 10 from 5 hearts for recovery time constants, N = 9 from 6 hearts for steady state inactivation, and N = 23 from 8 hearts for the I–V curve). Simulation results are solid lines. From left to right, top to bottom: steady state activation, steady state inactivation, fast time constant for inactivation, slow time constant for inactivation (insets show fast and slow recovery from inactivation), relative weight of the fast component for inactivation and the I–V curve (normalized). B) INaCa. Experimental data are digitally averaged time traces (N = 3 from 2 hearts, white circles, gray is standard error of the mean). Simulation results are the solid line. Top) Voltage clamp protocol. Bottom) INaCa in response to the clamp. C) IK1. Experimental data are previously unpublished (white circles, N = 21 from 12 hearts), from Bailly et al.[37] (black squares) and Konarzewska et al.[38](black triangles). Simulation results are solid lines (black, gray and dashed black for [K+]o = 4, 8 and 20 mM). Top left) Voltage and [K+]o dependence of steady state rectification. Top right) Voltage and [K+]o dependence of steady state inactivation. Bottom left) Time constant for inactivation. Bottom right) I–V curve, and its [K+]o dependence.](https://figures.cochat.ai/paper-figures/0607c8584c2240a5b55c36291194fb4c/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-2.jpg)
![Figure 3 Undiseased human IKr and IKs experiments and model validation. A) IKr. Experimental data are white circles (N = 10 from 7 hearts for steady state activation, N = 7 from 3 hearts for activation and from 2 hearts for deactivation time constants and weights, and N = 10 from 7 hearts for tail currents). Simulation results are lines. From left to right, top to bottom: steady state activation, time constant for activation (fast (solid) and slow (dashed) time constants converge), fast time constant for deactivation, slow time constant for deactivation, relative weight of the fast component for deactivation, and the I–V curve for normalized tail currents. B) Activation/deactivation profiles in response to the voltage steps shown (−40 mV holding potential to +30 mV steps of various duration, followed by a return to −40 mV, top right inset). Experiments are above. Simulations are below. Activation is rapid, occurring within tens of milliseconds. Deactivation is slow, occurring after several seconds. C) Human AP clamp waveform (top), used to elicit 1 µM E-4031 sensitive current (IKr, bottom); experiments are on the left, and comparison to simulations using the same AP clamp is on the right. D) IKs. Data are from Virág et al.[41] (black circles). Simulation results are solid lines. From left to right: steady state activation, time constant for activation (much slower than deactivation at depolarized potentials), time constant for deactivation (much faster than activation at hyperpolarized potentials), and the I–V curve, showing normalized tail currents.](https://figures.cochat.ai/paper-figures/e000cfe343c1469d9064b4a0eeb86bd0/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-3.jpg)
![Figure 4 Nonfailing human fast INa and late INa experiments and model validation. A) Fast INa. Experiments are from Sakakibara et al.[44] (black squares) and Nagatomo et al.[45] (black triangles). Simulation results are solid lines. From left to right, top to bottom: steady state activation, time to peak (experiment) and activation time constant (simulation), steady state inactivation, fast time constant for development of inactivation, slow time constant for development of inactivation, time constant for recovery from inactivation, and the I–V curve (solid line simulation and data at 17°C, dashed line simulation at 37°C). In other panels, simulations and data were adjusted to 37°C. Time to peak was fit at 33°C. B) Late INa. Experiments are from Maltsev et al.[51] (black squares). Simulation results are solid lines. Top) Steady state activation. Middle) Steady state inactivation. Bottom) I–V curve.](https://figures.cochat.ai/paper-figures/1bc72be1ff78416eb0539041b17ce71d/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-4.jpg)


![Figure 7 Undiseased human endocardial AP response to pacing protocols from experiments (small tissue preparations) and model simulations. A) Steady state APD rate dependence. B) S1S2 APD restitution (DI – diastolic interval). APD30–90 are labeled at right. Solid lines are simulation results; white squares are experiments at 37°C (N = 140 hearts in panel A, N = 50 hearts in panel B). C) Repolarization rate at CL = 1000 ms. Trajectory of APD30 to APD90 is accurate in the ORd model (white squares are experimental data); less so in other models. D) Dynamic restitution protocol (see Methods). Experiments are from Koller et al.[58], measured in nonfailing human hearts with monophasic AP electrodes (black squares). Simulated results are the black line. At very short diastolic intervals (DI<90 ms), the model shows APD bifurcation (alternans).](https://figures.cochat.ai/paper-figures/5bf8b14e1f23445fbe171a340c65ec27/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-7.jpg)


![Figure 10 Transmural heterogeneity and validation of transmural cell type models. A–C) Expression ratio in the model (black bars) compared to experimental data from undiseased human hearts (grayscale bars, labeled). D) Transmural heterogeneity of Ito; simulations are lines, experiments are squares. Results for endo are gray; those for epi are black. E1) Rate dependence of APD90 in endo, M, and epi cell types. Epi and M data were obtained by scaling endo data (white squares) by epi/endo and M/endo APD90 ratios from Drouin et al.[50] (black squares). Simulations are black lines. E2) Same format as panel E1, showing epi APD90 at faster pacing rates. Data are from Glukhov et al.[71], (epi/endo scaling, black triangles). F) Top to bottom: Rate-dependence of endo, M, and epi APs. G) Pseudo-ECG, using a simulated transmural wedge. CL changes are indicated by arrows.](https://figures.cochat.ai/paper-figures/1858cf93ccb24d138364411aa9171594/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-10.jpg)
![Figure 11 Early afterdepolarizations (EADs). A) Top left) Experiments in isolated nonfailing human endo myocytes from Guo et al.[73] showed EADs with slow pacing (CL = 4000 ms) in the presence of IKr block (0.1 µM dofetilide, ∼85% IKr block[74], reproduce with permission). Top right) Following the experimental protocol of Guo et al. (CL = 4000 ms, 85% IKr block) the ORd model accurately showed a single large EAD. Bottom) GB (left) and TP (right) models failed to generate EADs (CL = 4000 ms, even with 100% IKr block). B) EAD mechanism. APs are on top. ICaL (black) and ICaL recovery gate (gray) are below. Slow pacing alone (CL = 4000 ms) did not cause an EAD (left). Slow pacing plus IKr block (85%) caused an EAD (solid lines, right). The EAD was depolarized by ICaL reactivation during the slowly repolarizing AP plateau (solid lines, solid arrows). When ICaL recovery was prevented, the EAD was eliminated (dashed lines and dashed arrow).](https://figures.cochat.ai/paper-figures/f149e810e43a4018aa88d922b48d5501/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-11.jpg)
![Figure 12 Rate dependence of intracellular ion concentrations. Simulation results are solid lines. A) [Na+]i versus pacing frequency (normalized to 0.25 Hz). Experiments are from nonfailing myocytes (Pieske et al.[57], black squares). B) Peak Ca2+ transient (normalized to 0.5 Hz). Experiments are from nonfailing myocytes (Schmidt et al.[76], black squares). C) Ca2+ transients from experiments (Fura-2-AM) and simulations. Results are normalized to illustrate the time course of decay. The arrow indicates pacing CL changes. D) Frequency dependent acceleration of relaxation. Undiseased human experimental data are white circles. Simulations are the black line.](https://figures.cochat.ai/paper-figures/ef54eb92e96d49ff88664d97c8a51055/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-12.jpg)
![Figure 13 CaMK and Ca2+ cycling. A) Rate dependence of CaMK active fraction. B) Ca2+ cycling under control conditions (left) and without CaMK (right). CL changes are indicated by arrows. Top) [Ca2+]i and diastolic values (inset). Middle) [Ca2+]JSR. Bottom) Jup and Jrel (inset, expanded time scale).](https://figures.cochat.ai/paper-figures/e1891823cb1c44268191312b4fe6d66e/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-13.jpg)
![Figure 14 AP and Ca2+ alternans at fast pacing. Black lines are control. Gray lines are without CaMK. The two consecutive beats are labeled 1 and 2. A) Pacing at CL = 250 ms. From left to right, top to bottom: AP, expanded time scale showing AP repolarization, Jrel (inset is expanded time scale), [Ca2+]i, [Ca2+]JSR, and Jup. B) Rate dependence of APD (top) and peak [Ca2+]i (bottom) at fast rates (alternans bifurcations disappear without CaMK). C) Same as panel B, but at slower rates (no bifurcations).](https://figures.cochat.ai/paper-figures/eac046432d3a40d7b4647ffa370f37f5/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-14.jpg)

![Figure 16 Major causes of steady state APD rate dependence and S1S2 APD restitution. A) APD rate dependence in control (solid black), and with [Na+]i and [Na+]ss clamped to slow rate (solid gray) or fast rate (dashed black) values. When late INa (dashed gray) or both late INa and ICaL inactivation gates were reset to their slow rate values (dash-dot-dot gray) in addition to [Na+]i and [Na+]ss slow rate clamp, APD lost almost all rate dependence. Note that slow rate [Na+]i and [Na+]ss clamp alone left residual APD rate dependence, especially at fast rates (CL = 300 to 700 ms, shaded box). B) APD rate dependence (control, solid black) was largely unaffected by resetting inactivation gates for late INa (dashed gray), ICaL (dash-dot-dot gray), or late INa and ICaL (solid gray) to their slow rate values (no [Na+]i and [Na+]ss clamping to slow rate values). C) [Na+]i and INaK increase with pacing rate under control conditions (left). When [Na+]i and [Na+]ss are clamped to slow rate values, INaK is small and rate independent (right). D) APD restitution in control (solid black), and when inactivation gates were reset to S1 values upon S2 delivery (late INa reset – dashed gray, ICaL reset – dash-dot-dot gray, late INa and ICaL reset – solid gray). Shown in dashed black is resetting late INa and ICaL inactivation to the DI = 5 ms value. E) [Na+]i and [Na+]ss clamp to S1 values (dashed gray) did not affect APD restitution (control, solid black).](https://figures.cochat.ai/paper-figures/48cb13a7d63148b88e1f1a1a957108d3/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-16.jpg)

![Figure 18 Comparison with other human ventricular AP models. Single endo cell simulations from ORd, TP, and GB models are solid black, gray, and dashed black lines, respectively. Experimental results (small tissue preparations) are white squares. A) APD rate dependence. Results for APD90, 70, 50 and 30 are shown top left, top right, bottom left, and bottom right, respectively. B) The AP, major currents, [Na+]i, and [Ca2+]i at steady state for CL = 1000 ms. From left to right, top to bottom: AP (with Vm rest inset at far right), INa (inset shows peaks), late INa (not present in TP or GB models), Ito (inset shows decay rate), ICaL (arrow shows ORd peak magnitude; inset shows normalized peaks, which are wide in TP and GB), IKr (arrow shows ORd early spike peak magnitude), IKs, IK1, INaCa, INaK, [Ca2+]i, [Ca2+]i decay rate, and [Na+]i.](https://figures.cochat.ai/paper-figures/ed5768b836094b8fa6a37c72910bad90/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-18.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“For subject-specific virtual patients, it may be possible to collect pre- and post-intervention data from the same subject, enabling validation of both the virtual patient in isolation and the coupled device-patient model (Fig 2d; see [56] for an example in stent-graft deployment)”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [56]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Calmodulin kinase determines calcium-dependent facilitation of L-type calcium channels
Dzhura, I., Wu, Y., Colbran, R. J., Balser, J. R., & Anderson, M. E. (2000) · Nature Cell Biology · doi:10.1038/35004052 · Cited by 335 · cited 1×
“dog ICaL model[19] and as measured experimentally[21].”
RetractedCoassembly of KVLQT1 and minK (IsK) proteins to form cardiac IKS potassium channel
Sanguinetti, M. C., Curran, M. E., Zou, A., Shen, J., Specter, P. S., Atkinson, D. L., & Keating, M. T. (1996) · Nature · doi:10.1038/384080a0 · Cited by 1,764 · cited 1×
“. The presence of KCNE1 carries two important functional consequences 1) ∼5 fold slower activation and 2) ∼5 fold larger conductance”
Luo, C. H., & Rudy, Y. (1994) · Circulation Research · doi:10.1161/01.res.74.6.1071 · Cited by 1,589 · cited 1×
“guinea pig predecessor[80].”
Self-citationLuo, C. H., & Rudy, Y. (1991) · Circulation Research · doi:10.1161/01.res.68.6.1501 · Cited by 1,468 · cited 12×
“ON NA+ HANDLING, INAK AND APD RATE DEPENDENCE .......................................................... 32 EFFECT OF KCNE1 HETEROGENEITY ON TRANSMURAL IKS AND AP SIMULATIONS ..................................................................... 33 APD ACCOMMODATION .....................................................…”
BackgroundInfluentialSelf-citationSanguinetti, M. C., & Jurkiewicz, N. K. (1990) · The Journal of general physiology · doi:10.1085/jgp.96.1.195 · Cited by 1,457
A model for human ventricular tissue
ten Tusscher, K. H. W. J., Noble, D., Noble, P. J., & Panfilov, A. V. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00794.2003 · Cited by 1,416 · cited 1×
“The TP model[81] and updated”
Alternans and spiral breakup in a human ventricular tissue model
ten Tusscher, K. H. W. J., & Panfilov, A. V. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00109.2006 · Cited by 1,122 · cited 5×
“Rate dependence in the TP model[9] is less [Na]i dependent because, as Grandi discussed[10], IKs is exaggerated.”
InfluentialCalmodulin Is the Ca2+ Sensor for Ca2+-Dependent Inactivation of L-Type Calcium Channels
Peterson, B. Z., DeMaria, C. D., & Yue, D. T. (1999) · Neuron · doi:10.1016/s0896-6273(00)80709-6 · Cited by 856
Cellular Basis for the Electrocardiographic J Wave
Yan, G.-X., & Antzelevitch, C. (1996) · Circulation · doi:10.1161/01.cir.93.2.372 · Cited by 812
Wehrens, X. H. T., Lehnart, S. E., Reiken, S. R., & Marks, A. R. (2004) · Circulation Research · doi:10.1161/01.res.0000125626.33738.e2 · Cited by 623 · cited 1×
“Wehrens et al.[96] with KN-93 in rabbit) should be performed in human ventricular myocytes to validate model predictions.”
Method
Cited by
Items 901–1,000 of 1,000
Pacing and Ionic Conductance Effects on Excitation Waves in Early Afterdepolarization Cardiac Models
Prusty, D., & Nayak, A. R. (2025) · Journal of Computational and Nonlinear Dynamics · doi:10.1115/1.4069263 · Cited by 2
Development of a Family of Regional Cell Models
Colman, M. A. (2013) · Springer theses · doi:10.1007/978-3-319-01643-6_4 · Cited by 2
Computational Modelling of Cardiac Electrophysiology: from Cell to Bedside
Passini, E. (2015) · AMS Dottorato Institutional Doctoral Theses Repository (University of Bologna) · doi:10.6092/unibo/amsdottorato/7187 · Cited by 2
Dai, L., Zang, Y., Zheng, D., Luo, R., & Xia, L. (2014) · Computing in cardiology · doi:10.25405/ncl.34302771 · Cited by 2
Shivkumar, K., & Narayan, S. M. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3002806 · Cited by 2
“e ECGI solution to the inverse problem is steeped in fundamental studies of the mechanisms underlying activation and recovery at cellular (5) and subcellular levels and their subsequent translation into numerical computational models (6).”
Pro-arrhythmic effects of increased late sodium current in failing human heart
Bai, J., Wang, K., Bai, X., Yuan, Y., & Zhang, H. (2014) · doi:10.13140/rg.2.1.2928.5524 · Cited by 2
The Comprehensive In Vitro Proarrhythmia Assay Initiative
Turner, J. R., Karnad, D. R., & Kothari, S. (2016) · Springer eBooks · doi:10.1007/978-3-319-40347-2_9 · Cited by 2
Epstein, R., Mejia, J., & Robertson, R. E. (2016) · Behavior Analysis Research and Practice · doi:10.1037/bar0000052 · Cited by 2
Luo, C., Li, L., Liu, T., Wang, K., Bai, X., He, Y., & Zhang, H. (2018) · Computing in cardiology · doi:10.22489/cinc.2018.166 · Cited by 2
“The late sodium current (INaL) equation [13] was incorporated.”
MethodHeikhmakhtiar, A. K., Lee, C., Song, K. S., & Lim, K. M. (2020) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-020-02124-w · Cited by 2
“Nowadays, various electrophysiological cell models have been developed and validated with experimental data, producing many models with different types of species including the rabbit, human atrium, and ventricle [7, 17, 51, 55, 56, 59, 68, 69].”
BackgroundBystricky, W., Maier, C., Gintant, G. A., Bergau, D., & Carter, D. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.567383 · Cited by 2
“…complex approaches extend the cellular simulation to multiple scales up to the level of the whole heart in three dimensions (Zemzemi et al., 2013; Okada et al., 2015; Hwang et al., 2019; Yang et al., 2020) and combine simulation with machine learning techniques to assess the arrhythmogenic risk…”
BackgroundPhillips, K. G., Turnbull, I. C., Hajjar, R. J., Costa, K. D., & Mayourian, J. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.755881 · Cited by 2
“, 2004), healthy endocardial hCM (O’Hara et al., 2011; Mora et al., 2018), heart failure human cardiomyocyte in non-fibrotic myocardium (HF-hCM) (Mora et al.”
BackgroundResultInfluentialComputational Physiology: Simula Summer School 2021 − Student Reports
McCabe, K. J. (2022) · Simula SpringerBriefs on computing · doi:10.1007/978-3-032-28826-4 · Cited by 2
Simakov, S. S., Gamilov, T. M., Liang, F., Chomakhidze, P. S., & Kopylov, P. (2023) · Russian Journal of Numerical Analysis and Mathematical Modelling · doi:10.1515/rnam-2023-0013 · Cited by 2
Evaluating pro-arrhythmogenic effects of the T634S-hERG mutation: insights from a simulation study
Hu, W., Zhang, W., Zhang, K., Al‐Moubarak, E., Zhang, Y., Harmer, S. C., Hancox, J. C., & Zhang, H. (2023) · Interface Focus · doi:10.1098/rsfs.2023.0035 · Cited by 2
“In this study, we followed previous studies [34,37] to consider three distinct cell types in the transmural ventricular myocardium, which consists of EPI, MIDDLE and ENDO regions [34,37 – 39], and considered inhomogeneous I Kr densities among them, with a ratio of G Kr among the three regions as…”
BackgroundMethodInfluentialDevelopment of a New Model for Simulating the Electrical Action Potentials of Human Atrial Myocytes
Colman, M. A. (2013) · Springer theses · doi:10.1007/978-3-319-01643-6_3 · Cited by 2
Investigation of the mechanisms underlying cardiac alternans - insights from a computational study
Wang, W., Ni, H., & Zhang, H. (2015) · Computing in cardiology · doi:10.1109/cic.2015.7411107 · Cited by 2
“The O’Hara-Rudy model [4] of human ventricular cells was implemented to simulate cardiac alternans.”
MethodChapter 10. In Silico Organ Modelling in Predicting Efficacy and Safety of New Medicines
Rodríguez, B. (2014) · RSC drug discovery/RSC drug discovery series · doi:10.1039/9781782620136-00219 · Cited by 2
Ionic Modulation of Calcium Dynamics in Simulated Human Heart Failure
Mora, M. T., Ferrero, J. M., & Trénor, B. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.248-074 · Cited by 2
“(ORd), which includes a detailed formulation of calcium dynamics [8].”
BackgroundEffects of Quinidine on Short QT Syndrome Variant 2 in the Human Ventricles: a Modelling Study
Luo, C., Wang, K., Zhang, H., Liu, Y., & Xia, Y. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.310-147 · Cited by 2
Simulation of Electrical Restitution in Cardiomyocytes
Иванушкина, Н. Г., Ivanko, K. O., Prokopenko, Y. V., Redaelli, A. C. L., Timofeyev, V. I., & Visone, R. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-91008-6_62 · Cited by 2
Carbon Monoxide Effects on Electrophysiological Mechanisms of Ventricular Arrhythmogenesis
Al‐Owais, M. M., Holden, A. V., Peers, C., Steele, D. S., & Benson, A. P. (2018) · Computing in cardiology · doi:10.22489/cinc.2018.124 · Cited by 2
“In all simulations with the O’Hara & Rudy (2011) cell models, with a 100 beats at a BCL of 1 the effects of CO are to prolong the action potentials smoothly.”
InfluentialPersonalization of Cellular Electrophysiology Models: Utopia?
Clerx, M. (2018) · Computing in cardiology · doi:10.22489/cinc.2018.063 · Cited by 2
“compare the 30 mV corrections to human INa data employed in [23] to the mean voltage shift of around 5 mV caused by INa mutations [24]).”
MethodComposite Smeared Finite Element – Application to Electrical Field
Geroski, V., Milošević, M., Simić, V., Miličević, B., Filipović, N., & Kojić, M. (2020) · Learning and analytics in intelligent systems · doi:10.1007/978-3-030-43658-2_4 · Cited by 2
Electro-anatomical computational cardiology in humans and experimental animal models
Kharche, S., Mudathir, R., & McIntyre, C. W. (2022) · Translational Research in Anatomy · doi:10.1016/j.tria.2022.100162 · Cited by 2
Mechanisms Underlying QT Interval Adaptation Behind Heart Rate During Stress Test
Cebollada, R., Perez, C., Mountris, K. A., Martínez, J. P., Laguna, P., & Pueyo, E. (2021) · Computing in cardiology · doi:10.23919/cinc53138.2021.9662880 · Cited by 2
“AP model [9] was used to represent the electrophysiology of a human ventricular cell by including descriptions of the main ionic current and fluxes:”
MethodHaraguchi, R., Matsuyama, T., Yoshimoto, J., & Ashihara, T. (2019) · Computing in cardiology · doi:10.22489/cinc.2019.009 · Cited by 2
Observation Guided Systematic Reduction of a Detailed Human Ventricular Cell Model
Gerach, T., Weiß, D., Dössel, O., & Loewe, A. (2019) · Computing in cardiology · doi:10.22489/cinc.2019.357 · Cited by 2
Bialecki, R. A., Lainée, P., & Valentin, J.-P. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.64976-0 · Cited by 2
The generalized myocyte–fibroblast Fitzhugh–Nagumo bioheat model: design and study
Djoumessi, R. T., & Pelap, F. B. (2022) · Indian Journal of Physics · doi:10.1007/s12648-022-02394-0 · Cited by 2
Botti, S., Bartolucci, C., Altomare, C., Barile, L., Krause, R., Pavarino, L. F., & Severi, S. (2022) · Computing in cardiology · doi:10.22489/cinc.2022.101 · Cited by 2
van Herck, I., Mora, M. T., Llopis‐Lorente, J., Finsberg, H. N. T., Daversin, C., Sáiz, J., Trénor, B., Arevalo, H., & Wall", S. (2022) · Computing in cardiology · doi:10.22489/cinc.2022.033 · Cited by 2
“A fully coupled 0D ODE based EM model of endocardial ventricular tissue was developed by coupling a modified version of the O’Hara-Rudy electrophysiological model [6] and the Land model [7] for active contraction.”
MethodCarNum: parallel numerical framework for computational cardiac electromechanics
Liogky, A. A., Chernyshenko, A. Y., Danilov, A. A., & Syomin, F. A. (2023) · Russian Journal of Numerical Analysis and Mathematical Modelling · doi:10.1515/rnam-2023-0011 · Cited by 2
Computational Physiology: Simula Summer School 2023 − Student Reports
McCabe, K. J. (2024) · Simula SpringerBriefs on computing · doi:10.1007/978-3-031-53145-3 · Cited by 2
An integrative framework for computational modelling of cardiac electromechanics in the mouse
Land, S. (2013) · Oxford University Research Archive (ORA) (University of Oxford) · doi:10.5287/ora-wx6yednkk · Cited by 2
López-Yunta, M. (2018) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-124702 · Cited by 2
Computational Modelling in the Management of Patients with Aortic Valve Stenosis
Archer, G. T. (2020) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York) · Cited by 2
Koh, C. H., Wu, J., Chung, Y. Y., Liu, Z., Zhang, R., Chong, K., Korzh, V. P., Ting, S., Oh, S., SHIM, W. S. N., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-09613-3 · Cited by 2
Bueno‐Orovio, A., Britton, O. J., Muszkiewicz, A., & Rodríguez, B. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-394447-4.40014-3 · Cited by 2
Klein, V., Davids, M., Schad, L. R., Wald, L. L., & Guérin, B. (2022) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29293 · Cited by 2
Abstraction in Physiological Modelling Languages
McKeever, S., Gill, M., Connor, A. J., & Johnson, D. (2013) · Uppsala University Publications (Uppsala University) · doi:10.13140/rg.2.1.4232.8161 · Cited by 2
The effect of increasing amitriptyline doses on cardiomyocytes’ electrophysiology – simulation study
Tylutki, Z., Jornil, J. R., & Polak, S. (2016) · Bio-Algorithms and Med-Systems · doi:10.1515/bams-2015-0043 · Cited by 1
“The O’Hara-Rudy model build-in to CSS was used during the study [8].”
MethodKong, C. H. T., & Cannell, M. B. (2023) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2023.07.005 · Cited by 1
“The V m - and Ca 2+ -dependence of LCC gating kinetics was calculated using the LCC open probability (P O,LCC ) from existing LCC models [25,26] and mean open time ( τ O,LCC ) from single channel recordings made in near physiological conditions [27].”
Modeling Human Ventricular Cardiomyocyte Force-Frequency Relationship
Duhme, J.-E., Krauß, J., & Loewe, A. (2024) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2024-2051 · Cited by 1
Seo, Y. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27135774 · Cited by 1
“Multi-channel data can be incorporated into mathematical cardiomyocyte models to estimate how simultaneous effects on IKr, INa, ICa, L, IKs, and other currents influence repolarization reserve, action-potential duration, and torsadogenic risk [44–49, 129 ].”
Wilders, R. (2022) · Computing in cardiology · doi:10.22489/cinc.2022.294 · Cited by 1
“[8] (ORd 2017 model) at 1 Hz stimulation.”
MethodInfluentialDokuchaev, A., Kursanov, A. G., Balakina-Vikulova, N. A., Katsnelson, L. B., & Solovyova, O. E. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1187956 · Cited by 1
“, 2014), including models of human cardiomyocytes starting from the original TNNP and ORd models of cell electrophysiology (O’Hara et al., 2011; Christophe, 2013; Vandersickel et al., 2016; Kojima et al., 2020) to their recent updates (Tomek et al.”
MethodMyocardial ischemia simulation based on a multi-scale heart electrophysiology model
Zhu, J., Li, M., & Liu, R. (2024) · Technology and Health Care · doi:10.3233/thc-248003 · Cited by 1
Trancuccio, A., Tarifa, C., Bongianino, R., Priori, S. G., & Santiago, D. J. (2024) · Scientific Reports · doi:10.1038/s41598-024-80726-2 · Cited by 1
“Following previously published methodology 17 , FRC was used to quantify the voltage and time dependencies of inactivation.”
InfluentialDong, Y., & Liu, F. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms252413396 · Cited by 1
“Human ventricular cardiomyocyte models, parameterized with ion channel and calcium handling data derived from human experimental data by Grandi et al. [20] and more recently by O’Hara et al. [21], exemplify rigorous efforts to standardize these models.”
Rosales, R. M., Doblaré, M., Mazo, M. M., & Pueyo, E. (2024) · Computing in cardiology · doi:10.22489/cinc.2024.376 · Cited by 1
“The biophysically detailed cellular models of O’Hara et al. [9], Paci et al. [10] and Stewart et al. [11] were em-Figure ployed for the definition of the HZ, the hiPSC-CM and CS APs, respectively.”
BackgroundNebot, L., Villar‐Valero, J., Gómez, J. F., Boukens, B. J., & Trénor, B. (2024) · Computing in cardiology · doi:10.22489/cinc.2024.428 · Cited by 1
“To simulate the presence of fibroblasts in the BZ a model based on MacCannell et al. (2007) [12] combined with the modified O’Hara myocyte model [10] was incorporated.”
Multi-scale Cardiac Modeling for ECG Forward Problem Based on Finite Element Method
Chen, L., Li, Y., Li, M., Lv, X., Yang, Z., & Zhang, H. (2024) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm62325.2024.10822228 · Cited by 1
“The basic theory of the model can be referenced in Ref [23-24].”
Sex differences in cardiac dynamics during myocardial ischemia using a single cell approach
Wei, N. (2025) · Scientific Reports · doi:10.1038/s41598-025-94055-5 · Cited by 1
“A modified human ventricular model, based on 48 and an updated version of the O’Hara human cell model (ORd) 49 , was used to investigate the electrophysiological properties under ischemic conditions.”
Independent derivations of the axis of arrhythmia for predicting drug‐induced torsades de pointes
Heitmann, S., Vandenberg, J. I., & Hill, A. P. (2025) · British Journal of Pharmacology · doi:10.1111/bph.70078 · Cited by 1
Bueno‐Palomeque, F. L., Zacur, E., Pueyo, E., Crispi, F., Laguna, P., & Mincholé, A. (2025) · The Journal of Physiology · doi:10.1113/jp288197 · Cited by 1
“The O’Hara-Rudy (ORd) AP model for healthy tissue (Dutta et al., 2017; O’Hara et al., 2011) was used to simulate the cellular electro-physiological behaviour of the ventricles.”
Frosio, A., Marchese, P., Bertoli, G., Molla, D., Arici, M., Bartolucci, C., Piantoni, C., Guidi, G., Bazzini, C., Benzoni, P., et al. (2025) · EP Europace · doi:10.1093/europace/euaf160 · Cited by 1
The influence of intercalated disk nanostructure on local ionic currents and cardiac conduction
Sui, R., Moise, N., & Weinberg, S. H. (2025) · Biophysical Journal · doi:10.1016/j.bpj.2025.11.025 · Cited by 2
Heikhmakhtiar, A. K., Qauli, A. I., Fuadah, Y. N., Pramudito, M. A., Pramawijaya, I. N., Marcellinus, A., Seok, K. Y., Vanheusden, F. J., & Lim, K. M. (2025) · Toxicological Research · doi:10.1007/s43188-025-00320-0 · Cited by 1
“To simulate the electrophysiological effects of drugs on the human ventricle, the FDA based its framework on the O’Hara-Rudy dynamic (ORD) model [11, 12].”
Reduced Macroscopic Models: The Monodomain and Eikonal Models
Franzone, P. C., Pavarino, L. F., & Scacchi, S. (2014) · Modeling, simulation & applications · doi:10.1007/978-3-319-04801-7_4 · Cited by 1
Janková, N., Král, M., Švecová, O., Zídková, J., Lietava, S., Sladeček, S., Pacherník, J., Pašek, M., Novotný, T., & Bébarová, M. (2026) · EP Europace · doi:10.1093/europace/euag001 · Cited by 1
“13 The variant caused a ∼ 69% reduction of I Kr , while no or only subtle changes were detected in voltage-and time-dependent characteristics of the channel gating.”
Simone, F., Trancuccio, A., Sochacki, J., Prieto, C. M., Priori, S. G., Pavarino, L. F., & Santiago, D. J. (2026) · Scientific Reports · doi:10.1038/s41598-026-37707-4 · Cited by 1
Rosales, R. M., Wu, M., Claus, P., Janssens, S., Ríos-Muñoz, G. R., Fernández‐Santos, M. E., Martínez‐Legazpi, P., Bermejo, J., Flanagan, A., Doblaré, M., et al. (2026) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1013688 · Cited by 1
costi, M., Ferrero, J. M., & Matas, J. F. R. (2026) · Computational and Structural Biotechnology Journal · doi:10.34133/csbj.0041 · Cited by 1
“Over the years, several models have been proposed to study electrophysiological phenomena ranging from reentry mechanisms, such as rotors, to the prediction of pharmacological effects induced by newly administered drugs, such as the O’Hara–Rudy model [ 20 ].”
Olivia, Y., Park, H., Ariyadi, Qauli, A. I., Fuadah, Y. N., Marcellinus, A., Heikhmakhtiar, A. K., & Lim, K. M. (2026) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2026.117831 · Cited by 1
Kiseleva, D. G., Kazakova, M. A., Plyusnina, T. Y., Markina, Y. V., & Markin, A. M. (2026) · BioMedInformatics · doi:10.3390/biomedinformatics6030027 · Cited by 1
“Contemporary biophysically detailed cardiac electrophysiology models, including those developed by ten Tusscher and Pan-filov [16], O’Hara–Rudy [17], Gattoni et al. [18], and ToR-ORd [19], incorporate comprehensive descriptions of ionic currents, intracellular calcium handling, and membrane…”
Ohnemus, S., Dasí, A., Ramadan, A. F., Greiner, J., Wülfers, E. M., Stoyek, M. R., Tillert, L., Vierock, J., Quinn, T. A., Köhl, P., et al. (2026) · The Journal of Physiology · doi:10.64898/2026.05.11.724228 · Cited by 1
Buonocunto, M., Jung, A., Meier, S., & Heijman, J. (2026) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2026.2674735 · Cited by 1
“Among these, a derivative of the O’Hara et al. model [32] of the human ventricular cardiomyocyte, CiPAORdv1.”
Dominguez-Gomez, P., Zingaro, A., Balzotti, C., Leitner, M., Jacobo‐Piqueras, N., Vazquez, M., Rast, G. F., & Aguado‐Sierra, J. (2026) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2026.106138 · Cited by 1
Flannery, K., Miller, J. A., Poelzing, S., & Weinberg, S. H. (2026) · The Journal of Physiology · doi:10.1113/jp290497 · Cited by 1
Synthetic cannabinoid receptor agonists inhibit the cardiac voltage-gated potassium channel hERG
Ottosson, N. E., Frampton, D. J. A., Pipatpolkai, T., Norman, C., Karlsson, U., Jauregi‐Miguel, A., Venter, M., Sridhar, A., Larsson, H. P., Gréen, H., et al. (2026) · Acta Pharmacologica Sinica · doi:10.1038/s41401-026-01876-9 · Cited by 1
“ORd Model MATLAB simulations of the ventricular action potential in the epicardium of the human heart were performed using the ORd model as previously described [41, 42].”
Computer simulations to investigate the causes of T-wave notching
Galeotti, L., van Dam, P. M., Johannesen, L., Vicente, J., & Strauss, D. G. (2015) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2015.08.012 · Cited by 1
“Using the O’Hara–Rudy model [7], we simulated the effects of a pure-hERG potassium channel”
MethodヒトiPS細胞由来心筋細胞シートの不整脈研究への応用可能性:in silico不整脈学の観点から
貴司, 芦., 黒川, 洵., 泰成, 諫., 亮, 原., Inada, S., 一雄, 中., & 稔, 堀. (2015) · Seitai ikougaku/Seitai ikogaku · doi:10.11239/jsmbe.53.100 · Cited by 1
Badyra, B., Lisowski, B., Polak, S., Kudolo, J., & Wiśniowska, B. (2015) · PubMed · Cited by 1
Sampedro-Puente, D. A., Fernández-Bes, J., & Pueyo, E. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.250-453 · Cited by 1
“(ORd) human ventricular model [6] served as a basis to construct a set of AP models covering a range of experimentally observed characteristics.”
MethodCombined mathematical model of the electrical and mechanical activity of the human cardiomyocyte
Sulman, T., Solovyova, O. E., & Katsnelson, L. B. (2018) · Ural Symposium on Biomedical Engineering, Radioelectronics and Information Technology (USBEREIT) · doi:10.1109/usbereit.2018.8384541 · Cited by 1
“Combined electrical and mechanical subunits We developed electromechanical model of the human cardiomyocyte (E-ORd model) combining O'Hara-Rudy model (ORd) describing human cardiac ventricular action potential and ionic currents [1] with the Ekaterinburg mechanical activity and calcium handling model created earlier a…”
MethodNi, H., Rajamani, S., & Giles, W. R. (2019) · International Journal of Cardiology · doi:10.1016/j.ijcard.2019.02.011 · Cited by 1
Fibroblasts Induce Calcium Alternans When Coupled to Cardiomyocytes: A Simulation Study
Mora, M. T., Dasí, A., Sáiz, J., Trénor, B., & Ferrero, J. M. (2018) · Computing in cardiology · doi:10.22489/cinc.2018.140 · Cited by 1
“[6] was used to simulate the electrophysiological activity of endocardial myocytes and,”
MethodWatanabe, K., Tsubouchi, T., Yamada, T., Hinoi, E., & Miyawaki, I. (2019) · The Journal of Toxicological Sciences · doi:10.2131/jts.44.441 · Cited by 1
“Although in vitro and in silico assay systems that use in vitro data of multiple cardiac ion channel inhibitory potential have been reported as challenges for TdP risk prediction (Kramer et al., 2013; O’Hara et al., 2011; Li et al., 2019), in vivo studies are considered as the definitive approach.”
Coupling of PDE and ODE Solvers in INMOST Parallel Platform: Application to Electrophysiology
Chernyshenko, A. Y., Danilov, A. A., & Kramarenko, V. K. (2019) · Communications in computer and information science · doi:10.1007/978-3-030-36592-9_16 · Cited by 1
Observation Guided Systematic Reduction of a Detailed Human Ventricular Cell Model
Gerach, T., Weis, D., Dössel, O., & Loewe, A. (2019) · Computing in cardiology · doi:10.23919/cinc49843.2019.9005729 · Cited by 1
“In this study, we use the ORd model [4] to represent human ventricular electrophysiology.”
BackgroundMethodBartolucci, C., Paci, M., Hyttinen, J., Passini, E., & Severi, S. (2019) · Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) · doi:10.23919/cinc49843.2019.9005755 · Cited by 1
“The ORd human ventricular AP [1] model was chosen as basis for this study because of the large number of”
MethodInfluentialZhang, S., Wang, W., Wang, K., Shen, W., & Zhang, H. (2020) · IEEE Access · doi:10.1109/access.2020.2992102 · Cited by 1
“[47] in their simulation on the O’Hara & Rudy human ventricular cell model [48], in which a moderate decrease of [Ca]JSR promotes CaT alternans, but further depletion of [Ca]JSR abolishes CaT alternans.”
MethodAfterdepolarlizations induced by wave pattern in human ventricular tissue
Wang, X., Peng, W., & Guo-Ning, T. (2017) · Acta Physica Sinica · doi:10.7498/aps.66.068201 · Cited by 1
Fabbri, A., Prins, A., & de Boer, T. P. (2020) · Computing in cardiology · doi:10.22489/cinc.2020.381 · Cited by 1
“on the O’Hara-Rudy 2011 model [9], one of the latest and most used models).”
MethodKEY FACTORS TO THE RATE DEPENDENCE OF EARLY AFTERDEPOLARIZATIONS: A SIMULATION STUDY
Jin, L. J., Huang, Y., Zhu, H., Geng, Z., & Wu, X. (2021) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519421500020 · Cited by 1
Adaptation of the Calcium-dependent Tension Development in Ventricular Cardiomyocytes
Appel, S., Gerach, T., Dössel, O., & Loewe, A. (2021) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2021-2064 · Cited by 1
Rate dependence of early afterdepolarizations in the His-Purkinje system: A simulation study
Geng, Z., Jin, L. J., Huang, Y., & Wu, X. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106665 · Cited by 1
Curious ECG Morphology of a Cardiac Device: A New Normal?
Murphy, C. E., Bartol, K. D., & Symons, J. G. (2022) · Circulation · doi:10.1161/circulationaha.122.059326 · Cited by 1
Monasterio, V., Pueyo, E., Rodríguez-Matas, J. F., & Carro, J. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107121 · Cited by 1
Prediction of anesthetic torsadogenicity using a human ventricular cell model
Kojima, A., Fukushima, Y., & Matsuura, H. (2023) · Journal of Anesthesia · doi:10.1007/s00540-023-03238-9 · Cited by 1
“The O’Hara-Rudy dynamic (ORd) model provides a detailed description of the electrophysiological properties of endocardial, mid-myocardial and epicardial cells in undiseased human ventricles, such as action potentials, ionic currents and intracellular ion concentrations [19].”
BackgroundMethodMythri, T. G., Shaikh, J. H., Greenstein, J. L., Winslow, R. L., & Bhattacharya, B. (2024) · Journal of Engineering Mechanics · doi:10.1061/jenmdt.emeng-7487 · Cited by 1
Mathematical Models of Cellular Bioelectrical Activity
Franzone, P. C., Pavarino, L. F., & Scacchi, S. (2014) · Modeling, simulation & applications · doi:10.1007/978-3-319-04801-7_2 · Cited by 1
The Mechanistic Basis of hERG Blockade and the Proarrhythmic Effects Thereof
Pearlstein, R. A., MacCannell, K. A., Hu, Q., Farid, R., & Duca, J. S. (2015) · Methods and principles in medicinal chemistry · doi:10.1002/9783527673643.ch14 · Cited by 1
Model Composition for Biological Mathematical Systems
Gill, M., McKeever, S., & Gavaghan, D. J. (2014) · International Conference on Model-Driven Engineering and Software Development · doi:10.5220/0004699202170224 · Cited by 1
“They can be used to alter equations, for example to model ion channel changes and resulting effect on the AP caused by mutation or drug block (O’Hara et al., 2011) in an abstracted manner.”
MethodComputational Modelling of Cardiac Electrophysiological Changes in Malarial Fever.
Atkinson, L., Basharat, A., Benson, A. P., Colman, M. A., Holden, A. V., Kagugube, G. W., & Pervolaraki, E. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.315-270 · Cited by 1
“● with changed parameters ◌ with standard values for O’Hara Rudy [9] endo- (bottom trace) , M- (top trace) and epicardial (middle trace) cell models.”
MethodTwo Aspects of Cardiac Alternans: Difference and Correlation Between Them
Wang, W., Whittaker, D. J., Ni, H., Wang, K., & Zhang, H. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.316-259 · Cited by 1
“(the TP model), and the other is the O’Hara-Rudy dynamic model [6] (the ORd model).”
MethodNi, H., Whittaker, D. J., Wang, W., & Zhang, H. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.243-411 · Cited by 1
Global Optimization Approaches to Generate Dynamically Robust Electrophysiological Models
Krogh‐Madsen, T., & Christini, D. J. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-44733-1.00032-8 · Cited by 1
Batista, L., Bastogne, T., Delaunois, A. G., Valentin, J., & Atienzar, F. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.05.038 · Cited by 1
Metadata
- Authors
- O'Hara, T., Virág, L., Varró, A., & Rudy, Y.
- Affiliations
- University of Szeged (HU)
- Washington University in St. Louis (US)
- Corresponding author
- Rudy, Yoram
- Venue
- PLoS Computational Biology
- Publisher
- Public Library of Science (PLoS)
- Published
- 2011-05-26
- Volume
- 7
- Issue
- 5
- Pages
- e1002061
- ISSN
- 1553-734X (ISSN-L)
- 1553-7358
- PMC
- PMC3102752
- OpenAlex
- W2115765852
- Cited by
- 1,196
- References
- 110
- Citations by year
- 2026: 50 · 2025: 61 · 2024: 89 · 2023: 102 · 2022: 95 · 2021: 97 · 2020: 118 · 2019: 98 · 2018: 89 · 2017: 100 · 2016: 83 · 2015: 67 · 2014: 63 · 2013: 47 · 2012: 27
- FWCI
- 31.78
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- PLoS Computational Biology (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- SZTE Publicatio Repozitórium (University of Szeged) (acceptedVersion, other-oa)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Science Foundation (0929633)
- American Heart Association
- Fondation Leducq
- Hungarian Scientific Research Fund (OTKA CNK-77855)
- Nemzeti Kutatási és Technológiai Hivatal
- National Institutes of Health
- U.S. Public Health Service (R01-HLR01033343-26)
- National Heart, Lung, and Blood Institute (R01HL049054, R01HL-049054-18, R56HL049054)
- Division of Chemical, Bioengineering, Environmental, and Transport Systems
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion channel regulation and function
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- cardiac electrophysiology models, L-type calcium current, transient outward potassium current, Na+/Ca2+ exchanger, inward rectifier potassium current, action potential duration restitution, rate dependence, early afterdepolarizations, calcium alternans, calcium/calmodulin-dependent protein kinase, SERCA, intracellular sodium, late sodium current, transmural heterogeneity, human ventricular myocytes
- MeSH terms
- Action Potentials, Arrhythmias, Cardiac, Calmodulin, Heart Ventricles, Humans, Models, Cardiovascular, Reproducibility of Results, Sodium Channels, Ventricular Function, Patch-Clamp Techniques, Computational Biology, Calcium Channels, L-Type, Myocytes, Cardiac
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.