Simulation of the Undiseased Human Cardiac Ventricular Action Potential: Model Formulation and Experimental Validation
Open accessThe DOI matches its Crossref record; 110 of the 110 references it cites were found in a registry or an index.
Abstract
Cellular electrophysiology experiments, important for understanding cardiac arrhythmia mechanisms, are usually performed with channels expressed in non myocytes, or with non-human myocytes. Differences between cell types and species affect results. Thus, an accurate model for the undiseased human ventricular action potential (AP) which reproduces a broad range of physiological behaviors is needed. Such a model requires extensive experimental data, but essential elements have been unavailable. Here, we develop a human ventricular AP model using new undiseased human ventricular data: Ca(2+) versus voltage dependent inactivation of L-type Ca(2+) current (I(CaL)); kinetics for the transient outward, rapid delayed rectifier (I(Kr)), Na(+)/Ca(2+) exchange (I(NaCa)), and inward rectifier currents; AP recordings at all physiological cycle lengths; and rate dependence and restitution of AP duration (APD) with and without a variety of specific channel blockers. Simulated APs reproduced the experimental AP morphology, APD rate dependence, and restitution. Using undiseased human mRNA and protein data, models for different transmural cell types were developed. Experiments for rate dependence of Ca(2+) (including peak and decay) and intracellular sodium ([Na(+)](i)) in undiseased human myocytes were quantitatively reproduced by the model. Early afterdepolarizations were induced by I(Kr) block during slow pacing, and AP and Ca(2+) alternans appeared at rates >200 bpm, as observed in the nonfailing human ventricle. Ca(2+)/calmodulin-dependent protein kinase II (CaMK) modulated rate dependence of Ca(2+) cycling. I(NaCa) linked Ca(2+) alternation to AP alternans. CaMK suppression or SERCA upregulation eliminated alternans. Steady state APD rate dependence was caused primarily by changes in [Na(+)](i), via its modulation of the electrogenic Na(+)/K(+) ATPase current. At fast pacing rates, late Na(+) current and I(CaL) were also contributors. APD shortening during restitution was primarily dependent on reduced late Na(+) and I(CaL) currents due to inactivation at short diastolic intervals, with additional contribution from elevated I(Kr) due to incomplete deactivation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 1 Undiseased human ICaL experiments and model validation. A) Experiments: ICaL traces for currents carried by Ca2+ (top), Ba2+ (middle), and Sr2+ (bottom). The voltage protocol is below the Ca2+ traces. Ca2+ current decay was visibly more rapid than decay for Ba2+ or Sr2+ currents. Simulations: ICaL in response to the same voltage protocol with CDI (CDI+VDI, top), and without CDI (VDI-only, bottom). B) Experimental data are on the left (white circles, N = 5, from 3 hearts). Simulation results are on the right (solid lines). FRC is fractional remaining current. Times after peak current shown are from 5 to 55 ms, in 5 ms steps (indicated by arrow). Top left) Experiments showing the voltage and time dependence of FRC with Ba2+ as charge carrier (VDI only). Top right) Simulations of FRC, with n−gate = 0 (representing VDI only; see text and panel E). Bottom left) Experiments showing FRC with Ca2+ as charge carrier (CDI and VDI are concurrent). FRC for CDI+VDI was significantly smaller at more hyperpolarized potentials (Vm = −20 to 0 mV, dashed box) than FRC for VDI-alone. Bottom right) Simulations of FRC with free running n gate, allowing both CDI and VDI to occur. C) Data are from Magyar et al.[11] (black squares), Fulop et al.[12] (black diamonds), and previously unpublished (white circles, N = 5, from 3 hearts). Simulation results are solid lines. From left to right, top to bottom: steady state activation, steady state inactivation, fast time constant for VDI, slow time constant for VDI, relative weight of the fast component for VDI, I–V curve, experiments showing recovery from inactivation, and corresponding simulations. D) Human AP clamp waveform, used to elicit 1 µM nisoldipine sensitive current (ICaL, experiments, left) and comparison to simulations using the same AP clamp (right). E) Schematic diagram for the n gate, representing the fraction of L-type channels undergoing CDI. Calmodulin (CaM) is constitutively attached to the L-type channel. Ca2+ ions bind to CaM (on-rate k1 and off-rate k-1). With Ca2+ ions bound, the Ca2+/CaM/channel complex may activate CDI mode (asterisk and black color indicate CDI activation, on-rate k2 and off-rate k-2).](https://figures.cochat.ai/paper-figures/77154b4d77164fafa05b6b606a19318d/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-1.jpg)
![Figure 2 Undiseased human Ito, INaCa, and IK1 experiments and model validation. A) Ito. Experimental data are white circles (N = 8 from 5 hearts for inactivation time constants, N = 10 from 5 hearts for recovery time constants, N = 9 from 6 hearts for steady state inactivation, and N = 23 from 8 hearts for the I–V curve). Simulation results are solid lines. From left to right, top to bottom: steady state activation, steady state inactivation, fast time constant for inactivation, slow time constant for inactivation (insets show fast and slow recovery from inactivation), relative weight of the fast component for inactivation and the I–V curve (normalized). B) INaCa. Experimental data are digitally averaged time traces (N = 3 from 2 hearts, white circles, gray is standard error of the mean). Simulation results are the solid line. Top) Voltage clamp protocol. Bottom) INaCa in response to the clamp. C) IK1. Experimental data are previously unpublished (white circles, N = 21 from 12 hearts), from Bailly et al.[37] (black squares) and Konarzewska et al.[38](black triangles). Simulation results are solid lines (black, gray and dashed black for [K+]o = 4, 8 and 20 mM). Top left) Voltage and [K+]o dependence of steady state rectification. Top right) Voltage and [K+]o dependence of steady state inactivation. Bottom left) Time constant for inactivation. Bottom right) I–V curve, and its [K+]o dependence.](https://figures.cochat.ai/paper-figures/0607c8584c2240a5b55c36291194fb4c/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-2.jpg)
![Figure 3 Undiseased human IKr and IKs experiments and model validation. A) IKr. Experimental data are white circles (N = 10 from 7 hearts for steady state activation, N = 7 from 3 hearts for activation and from 2 hearts for deactivation time constants and weights, and N = 10 from 7 hearts for tail currents). Simulation results are lines. From left to right, top to bottom: steady state activation, time constant for activation (fast (solid) and slow (dashed) time constants converge), fast time constant for deactivation, slow time constant for deactivation, relative weight of the fast component for deactivation, and the I–V curve for normalized tail currents. B) Activation/deactivation profiles in response to the voltage steps shown (−40 mV holding potential to +30 mV steps of various duration, followed by a return to −40 mV, top right inset). Experiments are above. Simulations are below. Activation is rapid, occurring within tens of milliseconds. Deactivation is slow, occurring after several seconds. C) Human AP clamp waveform (top), used to elicit 1 µM E-4031 sensitive current (IKr, bottom); experiments are on the left, and comparison to simulations using the same AP clamp is on the right. D) IKs. Data are from Virág et al.[41] (black circles). Simulation results are solid lines. From left to right: steady state activation, time constant for activation (much slower than deactivation at depolarized potentials), time constant for deactivation (much faster than activation at hyperpolarized potentials), and the I–V curve, showing normalized tail currents.](https://figures.cochat.ai/paper-figures/e000cfe343c1469d9064b4a0eeb86bd0/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-3.jpg)
![Figure 4 Nonfailing human fast INa and late INa experiments and model validation. A) Fast INa. Experiments are from Sakakibara et al.[44] (black squares) and Nagatomo et al.[45] (black triangles). Simulation results are solid lines. From left to right, top to bottom: steady state activation, time to peak (experiment) and activation time constant (simulation), steady state inactivation, fast time constant for development of inactivation, slow time constant for development of inactivation, time constant for recovery from inactivation, and the I–V curve (solid line simulation and data at 17°C, dashed line simulation at 37°C). In other panels, simulations and data were adjusted to 37°C. Time to peak was fit at 33°C. B) Late INa. Experiments are from Maltsev et al.[51] (black squares). Simulation results are solid lines. Top) Steady state activation. Middle) Steady state inactivation. Bottom) I–V curve.](https://figures.cochat.ai/paper-figures/1bc72be1ff78416eb0539041b17ce71d/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-4.jpg)


![Figure 7 Undiseased human endocardial AP response to pacing protocols from experiments (small tissue preparations) and model simulations. A) Steady state APD rate dependence. B) S1S2 APD restitution (DI – diastolic interval). APD30–90 are labeled at right. Solid lines are simulation results; white squares are experiments at 37°C (N = 140 hearts in panel A, N = 50 hearts in panel B). C) Repolarization rate at CL = 1000 ms. Trajectory of APD30 to APD90 is accurate in the ORd model (white squares are experimental data); less so in other models. D) Dynamic restitution protocol (see Methods). Experiments are from Koller et al.[58], measured in nonfailing human hearts with monophasic AP electrodes (black squares). Simulated results are the black line. At very short diastolic intervals (DI<90 ms), the model shows APD bifurcation (alternans).](https://figures.cochat.ai/paper-figures/5bf8b14e1f23445fbe171a340c65ec27/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-7.jpg)


![Figure 10 Transmural heterogeneity and validation of transmural cell type models. A–C) Expression ratio in the model (black bars) compared to experimental data from undiseased human hearts (grayscale bars, labeled). D) Transmural heterogeneity of Ito; simulations are lines, experiments are squares. Results for endo are gray; those for epi are black. E1) Rate dependence of APD90 in endo, M, and epi cell types. Epi and M data were obtained by scaling endo data (white squares) by epi/endo and M/endo APD90 ratios from Drouin et al.[50] (black squares). Simulations are black lines. E2) Same format as panel E1, showing epi APD90 at faster pacing rates. Data are from Glukhov et al.[71], (epi/endo scaling, black triangles). F) Top to bottom: Rate-dependence of endo, M, and epi APs. G) Pseudo-ECG, using a simulated transmural wedge. CL changes are indicated by arrows.](https://figures.cochat.ai/paper-figures/1858cf93ccb24d138364411aa9171594/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-10.jpg)
![Figure 11 Early afterdepolarizations (EADs). A) Top left) Experiments in isolated nonfailing human endo myocytes from Guo et al.[73] showed EADs with slow pacing (CL = 4000 ms) in the presence of IKr block (0.1 µM dofetilide, ∼85% IKr block[74], reproduce with permission). Top right) Following the experimental protocol of Guo et al. (CL = 4000 ms, 85% IKr block) the ORd model accurately showed a single large EAD. Bottom) GB (left) and TP (right) models failed to generate EADs (CL = 4000 ms, even with 100% IKr block). B) EAD mechanism. APs are on top. ICaL (black) and ICaL recovery gate (gray) are below. Slow pacing alone (CL = 4000 ms) did not cause an EAD (left). Slow pacing plus IKr block (85%) caused an EAD (solid lines, right). The EAD was depolarized by ICaL reactivation during the slowly repolarizing AP plateau (solid lines, solid arrows). When ICaL recovery was prevented, the EAD was eliminated (dashed lines and dashed arrow).](https://figures.cochat.ai/paper-figures/f149e810e43a4018aa88d922b48d5501/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-11.jpg)
![Figure 12 Rate dependence of intracellular ion concentrations. Simulation results are solid lines. A) [Na+]i versus pacing frequency (normalized to 0.25 Hz). Experiments are from nonfailing myocytes (Pieske et al.[57], black squares). B) Peak Ca2+ transient (normalized to 0.5 Hz). Experiments are from nonfailing myocytes (Schmidt et al.[76], black squares). C) Ca2+ transients from experiments (Fura-2-AM) and simulations. Results are normalized to illustrate the time course of decay. The arrow indicates pacing CL changes. D) Frequency dependent acceleration of relaxation. Undiseased human experimental data are white circles. Simulations are the black line.](https://figures.cochat.ai/paper-figures/ef54eb92e96d49ff88664d97c8a51055/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-12.jpg)
![Figure 13 CaMK and Ca2+ cycling. A) Rate dependence of CaMK active fraction. B) Ca2+ cycling under control conditions (left) and without CaMK (right). CL changes are indicated by arrows. Top) [Ca2+]i and diastolic values (inset). Middle) [Ca2+]JSR. Bottom) Jup and Jrel (inset, expanded time scale).](https://figures.cochat.ai/paper-figures/e1891823cb1c44268191312b4fe6d66e/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-13.jpg)
![Figure 14 AP and Ca2+ alternans at fast pacing. Black lines are control. Gray lines are without CaMK. The two consecutive beats are labeled 1 and 2. A) Pacing at CL = 250 ms. From left to right, top to bottom: AP, expanded time scale showing AP repolarization, Jrel (inset is expanded time scale), [Ca2+]i, [Ca2+]JSR, and Jup. B) Rate dependence of APD (top) and peak [Ca2+]i (bottom) at fast rates (alternans bifurcations disappear without CaMK). C) Same as panel B, but at slower rates (no bifurcations).](https://figures.cochat.ai/paper-figures/eac046432d3a40d7b4647ffa370f37f5/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-14.jpg)

![Figure 16 Major causes of steady state APD rate dependence and S1S2 APD restitution. A) APD rate dependence in control (solid black), and with [Na+]i and [Na+]ss clamped to slow rate (solid gray) or fast rate (dashed black) values. When late INa (dashed gray) or both late INa and ICaL inactivation gates were reset to their slow rate values (dash-dot-dot gray) in addition to [Na+]i and [Na+]ss slow rate clamp, APD lost almost all rate dependence. Note that slow rate [Na+]i and [Na+]ss clamp alone left residual APD rate dependence, especially at fast rates (CL = 300 to 700 ms, shaded box). B) APD rate dependence (control, solid black) was largely unaffected by resetting inactivation gates for late INa (dashed gray), ICaL (dash-dot-dot gray), or late INa and ICaL (solid gray) to their slow rate values (no [Na+]i and [Na+]ss clamping to slow rate values). C) [Na+]i and INaK increase with pacing rate under control conditions (left). When [Na+]i and [Na+]ss are clamped to slow rate values, INaK is small and rate independent (right). D) APD restitution in control (solid black), and when inactivation gates were reset to S1 values upon S2 delivery (late INa reset – dashed gray, ICaL reset – dash-dot-dot gray, late INa and ICaL reset – solid gray). Shown in dashed black is resetting late INa and ICaL inactivation to the DI = 5 ms value. E) [Na+]i and [Na+]ss clamp to S1 values (dashed gray) did not affect APD restitution (control, solid black).](https://figures.cochat.ai/paper-figures/48cb13a7d63148b88e1f1a1a957108d3/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-16.jpg)

![Figure 18 Comparison with other human ventricular AP models. Single endo cell simulations from ORd, TP, and GB models are solid black, gray, and dashed black lines, respectively. Experimental results (small tissue preparations) are white squares. A) APD rate dependence. Results for APD90, 70, 50 and 30 are shown top left, top right, bottom left, and bottom right, respectively. B) The AP, major currents, [Na+]i, and [Ca2+]i at steady state for CL = 1000 ms. From left to right, top to bottom: AP (with Vm rest inset at far right), INa (inset shows peaks), late INa (not present in TP or GB models), Ito (inset shows decay rate), ICaL (arrow shows ORd peak magnitude; inset shows normalized peaks, which are wide in TP and GB), IKr (arrow shows ORd early spike peak magnitude), IKs, IK1, INaCa, INaK, [Ca2+]i, [Ca2+]i decay rate, and [Na+]i.](https://figures.cochat.ai/paper-figures/ed5768b836094b8fa6a37c72910bad90/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-18.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“For subject-specific virtual patients, it may be possible to collect pre- and post-intervention data from the same subject, enabling validation of both the virtual patient in isolation and the coupled device-patient model (Fig 2d; see [56] for an example in stent-graft deployment)”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [56]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Calmodulin kinase determines calcium-dependent facilitation of L-type calcium channels
Dzhura, I., Wu, Y., Colbran, R. J., Balser, J. R., & Anderson, M. E. (2000) · Nature Cell Biology · doi:10.1038/35004052 · Cited by 335 · cited 1×
“dog ICaL model[19] and as measured experimentally[21].”
RetractedCoassembly of KVLQT1 and minK (IsK) proteins to form cardiac IKS potassium channel
Sanguinetti, M. C., Curran, M. E., Zou, A., Shen, J., Specter, P. S., Atkinson, D. L., & Keating, M. T. (1996) · Nature · doi:10.1038/384080a0 · Cited by 1,764 · cited 1×
“. The presence of KCNE1 carries two important functional consequences 1) ∼5 fold slower activation and 2) ∼5 fold larger conductance”
Luo, C. H., & Rudy, Y. (1994) · Circulation Research · doi:10.1161/01.res.74.6.1071 · Cited by 1,589 · cited 1×
“guinea pig predecessor[80].”
Self-citationLuo, C. H., & Rudy, Y. (1991) · Circulation Research · doi:10.1161/01.res.68.6.1501 · Cited by 1,468 · cited 12×
“ON NA+ HANDLING, INAK AND APD RATE DEPENDENCE .......................................................... 32 EFFECT OF KCNE1 HETEROGENEITY ON TRANSMURAL IKS AND AP SIMULATIONS ..................................................................... 33 APD ACCOMMODATION .....................................................…”
BackgroundInfluentialSelf-citationSanguinetti, M. C., & Jurkiewicz, N. K. (1990) · The Journal of general physiology · doi:10.1085/jgp.96.1.195 · Cited by 1,457
A model for human ventricular tissue
ten Tusscher, K. H. W. J., Noble, D., Noble, P. J., & Panfilov, A. V. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00794.2003 · Cited by 1,416 · cited 1×
“The TP model[81] and updated”
Alternans and spiral breakup in a human ventricular tissue model
ten Tusscher, K. H. W. J., & Panfilov, A. V. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00109.2006 · Cited by 1,122 · cited 5×
“Rate dependence in the TP model[9] is less [Na]i dependent because, as Grandi discussed[10], IKs is exaggerated.”
InfluentialCalmodulin Is the Ca2+ Sensor for Ca2+-Dependent Inactivation of L-Type Calcium Channels
Peterson, B. Z., DeMaria, C. D., & Yue, D. T. (1999) · Neuron · doi:10.1016/s0896-6273(00)80709-6 · Cited by 856
Cellular Basis for the Electrocardiographic J Wave
Yan, G.-X., & Antzelevitch, C. (1996) · Circulation · doi:10.1161/01.cir.93.2.372 · Cited by 812
Wehrens, X. H. T., Lehnart, S. E., Reiken, S. R., & Marks, A. R. (2004) · Circulation Research · doi:10.1161/01.res.0000125626.33738.e2 · Cited by 623 · cited 1×
“Wehrens et al.[96] with KN-93 in rabbit) should be performed in human ventricular myocytes to validate model predictions.”
Method
Cited by
Items 801–900 of 1,000
Drug-Induced Prolongation of the QT Interval: Present and Future Challenges for Drug Discovery
Gintant, G. A., & Valentin, J. (2015) · Springer eBooks · doi:10.1007/978-3-319-15961-4_49 · Cited by 4
“The O’Hara–Rudy computer reconstruction [ 85 ] is one candidate in silico model expected to integrate drug responses on multiple cardiac channels and detect emergent proarrhythmic events (including early afterpolarizations).”
MethodA Novel Bi-Level Framework for Fitting the Parameters in Cardiac Cellular Models
Pouranbarani, E., & Nygren, A. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512883 · Cited by 4
“Keen readers can refer to [14] for the detailed descriptions of the differential equation set related to the base model.”
BackgroundMethodInteractive 3D Human Heart Simulations on Segmented Human MRI Hearts
Berman, J. P., Kaboudian, A., Uzelac, I., Iravanian, S., Iles, T. L., Iaizzo, P. A., Lim, H., Smolka, S. A., Glimm, J. G., Cherry, E. M., et al. (2021) · Computing in cardiology · doi:10.23919/cinc53138.2021.9662948 · Cited by 4
“[16], who performed some of the first high-resolution simulations of the Luo-Rudy 1 model in a highly discretized rabbit ventricular structure, by performing some of the first simulations on a whole highresolution human heart with one of the most up-to-date human ventricular models, the O’Hara-Virág-Varró-Rudy (OVVR)…”
MethodInfluentialComputational analysis of the electromechanical consequences of short QT syndrome
Huang, C. L.-H. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00044 · Cited by 4
“…section of the article, further validation including improved and more physiologically detailed representations of Ca2+ dynamics (Iribe et al., 2006; Grandi et al., 2010; O’Hara et al., 2011) as further experimental data becomes available, will help test uniqueness in the model’s predictions.”
BackgroundGómez, J. F., Cardona, K., Romero, L., Sáiz, J., Belardinelli, L., Rajamani, S., & Trénor, B. (2012) · Computing in cardiology · Cited by 4
Computational analysis of Head-Down Bed Rest effects on cardiac action potential duration
Passini, E., Pellegrini, A., Caiani, E. G., & Severi, S. (2013) · Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) · Cited by 4
Multi-scale modeling and variability in cardiac cellular electrophysiology
Clerx (2017) · Research Publications (Maastricht University) · doi:10.26481/dis.20170420mc · Cited by 4
Marrus, S. B., Springer, S. J., Johnson, E., Martinez, R. J., Dranoff, E. J., Mellor, R. L., & Yamada, K. A. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/135400 · Cited by 4
“Equations for the computational models (see supporting data) of human ventricular IK1 and Ito,f were previously published by O’Hara et al.[22] Transcript analysis”
MethodInfluentialSafety pharmacology methods and regulatory considerations evolve together
Pugsley, M. K., Harter, M. L., de Korte, T., Connaughton, C. E., Authier, S., & Curtis, M. J. (2018) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2018.06.004 · Cited by 4
Şulea, T. A., Draga, S., Mernea, M., Corlan, A. D., Radu, B. M., Petrescu, A., & Amuzescu, B. P. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26010358 · Cited by 3
Influence of cellular mechano-calcium feedback in numerical models of cardiac electromechanics
Radišić, I., Regazzoni, F., Bucelli, M., Pagani, S., Dede’, L., & Quarteroni, A. M. (2025) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2025.118172 · Cited by 3
“For ionic models represented as systems of ODEs, such as (1), ion concentration evolutions are governed by extracellular ionic fluxes mediated by ionic channels, and intracellular ionic fluxes through various cellular compartments, mimicking the spatial disposition of a cardiomyocyte [39, 40].”
InfluentialZhang, Z., Green, J. T., Haigney, M. C., Walker, P. F., Shivkumar, K., Garfinkel, A., & Qu, Z. (2025) · Journal of the American Heart Association · doi:10.1161/jaha.125.042201 · Cited by 3
“We used 4 AP models: the 1994 Luo and Rudy (LRd) guinea pig model, 27 29 and the modified ORd model by Tomek et al.. 30 The endocardial versions of the human models were used.”
Casoni, E., Zingaro, A., Mora, M. M., Gómez, J. F., Pozo, J. M., Gonzalez-Martin, P., Vázquez, M., Trénor, B., & Aguado‐Sierra, J. (2026) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-025-02038-2 · Cited by 3
Zukowski, H. M., & Clancy, C. E. (2026) · The Journal of Physiology · doi:10.1113/jp289495 · Cited by 3
Ventricular Conduction System Modeling for Electrophysiological Simulation of the Porcine Heart
Rosales, R. M., Mountris, K. A., Doblaré, M., Mazo, M. M., & Pueyo, E. (2022) · Computing in cardiology · doi:10.22489/cinc.2022.030 · Cited by 3
“The O’HaraRudy model [7] was employed to represent the cellular action potential of the endo-, mid- and epicardium, while CS cellular electrophysiology was defined by the Stewart model [8].”
MethodPrediction of experimental cardiac magnetostimulation thresholds using pig‐specific body models
Klein, V., Davids, M., Vendramini, L., Ferris, N. G., Schad, L. R., Sosnovik, D. E., Nguyen, C. T., Wald, L. L., & Guérin, B. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29717 · Cited by 3
Mechanisms of fever-induced QT prolongation and torsades de pointes in patients with KCNH2 mutation
Usuda, K., Hayashi, K., Nakajima, T., Kurata, Y., Cui, S., Kusayama, T., Tsuda, T., Tada, H., Kato, T., Sakata, K., et al. (2023) · EP Europace · doi:10.1093/europace/euad161 · Cited by 3
“Computer simulations of human ventricular action potentials for wild-type and each mutant KCNH2 We simulated early afterdepolarization (EAD) generations in LQT2 cardiomyocytes using a mathematical model of human ventricular myocytes developed by Kurata et al.16 A mid-myocardial (M) cell version of the model was develo…”
MethodVerkerk, A. O., & Wilders, R. (2024) · Reviews in Cardiovascular Medicine · doi:10.31083/j.rcm2506194 · Cited by 3
Tsukada, S., Iwasaki, Y., & Tsukada, Y. T. (2024) · PLOS Digital Health · doi:10.1371/journal.pdig.0000273 · Cited by 3
Blair, G. A., Depman, M., Adams, W. P., Maisonneuve, R. O., Hoeker, G. S., Weinberg, S. H., & Poelzing, S. (2024) · Journal of the American Heart Association · doi:10.1161/jaha.123.030433 · Cited by 3
“We used an established human ventricular myocyte ionic model 38 to represent individual ion channel dynamics.”
Dominguez-Gomez, P., Butakoff, C., Rast, G. F., Darpö, B., Vázquez, M., & Aguado‐Sierra, J. (2025) · The Journal of Precision Medicine Health and Disease · doi:10.1016/j.premed.2025.100011 · Cited by 3
Particle model of creation and annihilation captures termination dynamics of spiral defect chaos
Tyree, T. J., Reiß, M., & Rappel, W. (2025) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/5.0277113 · Cited by 3
A Mathematical Spline-Based Model of Cardiac Left Ventricle Anatomy and Morphology
Pravdin, S. F. (2016) · Computation · doi:10.3390/computation4040042 · Cited by 3
“Recently, several models of the electrical and/or mechanical activity of the whole heart or its chambers have been proposed [1–12].”
BackgroundLuo, C., Wang, K., Liu, Y., Xia, Y., & Zhang, H. (2017) · Computing in cardiology · Cited by 3
Computer Modelling of Cardiac Cells Electrical Activity
Иванушкина, Н. Г., Ivanko, K. O., Prokopenko, Y. V., Timofeyev, V. I., Visone, R., & Redaelli, A. C. L. (2018) · IEEE International Conference on Electronics and Nanotechnology (ELNANO) · doi:10.1109/elnano.2018.8477567 · Cited by 3
“The study of the heart electrical activity is performed by using experimental and mathematical models [1, 2].”
MethodBartolucci, C., Passini, E., & Severi, S. (2018) · Computing in cardiology · doi:10.22489/cinc.2018.333 · Cited by 3
“Nowadays the “gold standard” in the in silico human ventricular cellular electrophysiology is the O’Hara-Rudy model (ORd) [3].”
BackgroundMethodInfluentialIntegrative and theoretical research on the architecture of a biological system and its disorder
Uchida, S., Asai, Y., Kariya, Y., Tsumoto, K., Hibino, H., Honma, M., Abé, T., Nin, F., Kurata, Y., Furutani, K., et al. (2019) · The Journal of Physiological Sciences · doi:10.1007/s12576-019-00667-8 · Cited by 3
Approach for Cardiac Action Potential Detection from Noised Recordings
Иванушкина, Н. Г., Ivanko, K. O., Prokopenko, Y. V., Redaelli, A. C. L., Timofeyev, V. I., & Ivanushkina, M. (2019) · IEEE International Conference on Electronics and Nanotechnology (ELNANO) · doi:10.1109/elnano.2019.8783603 · Cited by 3
“Many scientists focus their efforts to study the heart activity by using experimental and mathematical models [1, 2].”
BackgroundHemodynamic Effects of Late Sodium Current Inhibitors in a Swine Model of Heart Failure
Goldstein, R. E., Klein, M. G., Ouimet, S. P., Shou, M., Hood, M. N., Flagg, T. P., & Haigney, M. C. (2019) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2019.08.015 · Cited by 3
Dasí, A., Hernández‐Romero, I., Gómez, J. F., Climent, A. M., Ferrero, J. M., & Trénor, B. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104796 · Cited by 3
“The use of in-silico models has promoted the formulation of several virtual hAdultV-CM [13] and even hiPSC-CM models [14 – 16].”
MethodResultZaniboni, M. (2022) · Biomolecules · doi:10.3390/biom12070873 · Cited by 3
“2011 (OR) model of human ventricular AP [16] under oscillatory pacing, also in comparison with other numerical models.”
MethodResultDelaunois, A. G., Mathy, F., Cornet, M., Gryshkova, V., Korlowski, C., Bonfitto, F., Koch, J., Schlit, A., Hebeisen, S., Passini, E., et al. (2023) · Pharmacology Research & Perspectives · doi:10.1002/prp2.1059 · Cited by 3
Hohendanner, F., Böck, M., Keznickl-Pulst, J., Furundzija, V., Scholz, S., Schöppenthau, D., Hrytsyna, Y., Falk, V., Pieske, B. M., Hindricks, G., et al. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1086730 · Cited by 3
“More complex simulation models incorporate representations of the ventricular tissue structure and simulate a multitude of electrophysiological parameters or mechanical actuation (Kummer et al., 2022; O’Hara et al., 2011) potentially allowing to even analyze ablation effects on a cellular level.”
MethodHimeno, Y., Zhang, Y., Enomoto, S., Nomura, H., Yamamoto, N., Kiyokawa, S., Ujihara, M., Muangkram, Y., Noma, A., & Amano, A. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms242015378 · Cited by 3
“Accordingly, we first determined whether our comprehensive human ventricular myocyte (hVC) model [15] could reproduce the all-or-none repolarization as demonstrated by Trenor et al. (2017) [2] using the ORd model [12].”
MethodCell-to-cell heterogeneity in ion channel conductance impacts substrate vulnerability to arrhythmia
Pullinger, T. K., & Sobie, E. A. (2024) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00645.2023 · Cited by 3
Wei, N., & Diekman, C. O. (2025) · Journal of Biological Rhythms · doi:10.1177/07487304251326628 · Cited by 3
“In this paper, we focused on 11 of these drugs and used the O’Hara-Rudy (ORd) model of ventricular myocytes—the base model chosen for the in silico component of CiPA—to investigate how circadian regulation of cardiac ion channels affects drug-induced TdP risk (O’Hara et al., 2011).”
Okada, J., Washio, T., Hisada, T., & Sugiura, S. (2025) · Circulation Journal · doi:10.1253/circj.cj-24-0814 · Cited by 3
Lei, C. L., Clark, A. P., Clerx, M., Wei, S., Bloothooft, M., de Boer, T. P., Christini, D. J., Krogh‐Madsen, T., & Mirams, G. R. (2025) · Advanced Science · doi:10.1002/advs.202500691 · Cited by 3
In silico cardiac safety profile of drugs and their potential to induce clinical cardiotoxicity
Christophe, B. (2025) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2025.117426 · Cited by 3
Cardiac Arrhythmias: Mechanistic Knowledge and Innovation from Computer Models
Trayanova, N. A., & Boyle, P. M. (2015) · Modeling, simulation & applications · doi:10.1007/978-3-319-05230-4_1 · Cited by 3
“model has 19 equations [43], the O’Hara human ventricular model has 43 [91], and the Sampson human Purkinje fiber model has 83 [108].”
BackgroundMethodRecurrent Neural Networks for Classifying Human Embryonic Stem Cell-Derived Cardiomyocytes
Pacheco, C., & Vidal, R. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-00928-1_66 · Cited by 3
“The O’hara-Rudy model (ORd) [18] and the Nygren model [17] were paced at 1.”
Mulimani, M. K., Nayak, A. R., & Pandit, R. A. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033443 · Cited by 3
“, the O’Hara Rudy model [36], can be used; a comprehensive comparison of all these models lies beyond the scope of this paper.”
MethodAn inner‐outer subcycling algorithm for parallel cardiac electrophysiology simulations
Laudenschlager, S., & Cai, X. (2022) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3677 · Cited by 3
“This would further reduce simulation turnaround time, but also allow the subcycling algorithm to be seamlessly used on other potential ionic models, including the more recent ORd model.(50) However, further testing is required to determine the applicability of our subcycling algorithm to other ionic models.”
MethodMulimani, M. K., Zimik, S., Alageshan, J. K., Majumder, R., Nayak, A. R., & Pandit, R. A. (2023) · Springer eBooks · doi:10.1007/978-3-031-33588-4_18 · Cited by 3
Electrotonic Coupling Effect on Pharmacological Cardiotoxicity Assessment in Atrial Tissue
costi, M., torre, I. D., Ferrero, J. M., & Matas, J. F. R. (2023) · Computing in cardiology · doi:10.22489/cinc.2023.328 · Cited by 3
“However, previous results, as those in [9], have been obtained using a ventricular Action Potential model [14], and no specific study has been conducted for atrial cardiomyocytes.”
ResultA Metamorphosis Distance for Embryonic Cardiac Action Potential Interpolation and Classification
Gorospe, G., Laurent Younes, B., Tung, L., & Vidal, R. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40811-3_59 · Cited by 3
Linking a novel mutation to its short QT phenotype through multiscale computational modelling
Bartolucci, C., Moreno, C., de la Cruz, A., Lambiase, P. D., Severi, S., & Valenzuela, C. (2014) · Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) · Cited by 3
Recent human ventricular cell action potential models under varied ischaemic conditions
Dutta, S., Mincholé, A., Quinn, T. A., & Rodríguez, B. (2013) · Computing in cardiology · Cited by 3
A comparison of two models of human ventricular tissue: Simulated ischaemia and re-entry
Abbasi, M., & Clayton, R. H. (2013) · Computing in cardiology · Cited by 3
Porting Tissue-Scale Cardiac Simulations to the Knights Landing Platform
Langguth, J., Jarvis, C., & Cai, X. H. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-67630-2_28 · Cited by 3
Bialecki, R., Lainée, P., & Valentin, J. (2010) · Elsevier eBooks · doi:10.1016/b978-0-08-046884-6.00718-1 · Cited by 4
The effect of low potassium in Brugrada Syndrome: A simulation study
Cardona, K., Gómez, J. L., Sáiz, J., Giles, W. R., & Trénor, B. (2014) · Computing in cardiology · Cited by 3
Observability analysis and state observer design for a cardiac ionic cell model
Guzman, A., Vogt, R., Charron, C., Pusarla, K., & Muñoz, L. M. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103910 · Cited by 3
Pouranbarani, E., Berg, L. A., Oliveira, R. S., dos Santos, R. W., & Nygren, A. (2021) · Journal of Computational Science · doi:10.1016/j.jocs.2021.101375 · Cited by 3
Estimation of Parameters for an Archetypal Model of Cardiomyocyte Membrane Potentials
Aziz, N., & Simitev, R. D. (2022) · International Journal Bioautomation · doi:10.7546/ijba.2022.26.3.000832 · Cited by 3
“For example, a recent model of the human ventricular action potential [41] consists of 49 ordinary differential equations and includes 206 model parameters.”
Slepukhina, E., Bashkirtseva, I. A., Kügler, P., & Ryashko, L. B. (2021) · Mathematical Methods in the Applied Sciences · doi:10.1002/mma.7688 · Cited by 3
Heijman, J. (2012) · Research Publications (Maastricht University) · doi:10.26481/dis.20120427jh · Cited by 3
Vorobyov, I. V., & Clancy, C. E. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.01.028 · Cited by 3
Aghasafari, P., Yang, P., Kernik, D. C., Sakamoto, K., Kanda, Y., Kurokawa, J., Vorobyov, I. V., & Clancy, C. E. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.09.28.317461 · Cited by 3
“Comparing translated adult-CMs AP APD90 values with 50% IKr block (turquoise asterisks) with previously published simulated (red curve for drugged and black for drug-free control) and experimental (blue squares) values in O’Hara-Rudy study [40] indicates successful model validation.”
InfluentialSelvaggio, G., Wan, H., & Pearlstein, R. A. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.11.15.384032 · Cited by 3
“Materials and methods We previously generated the ORd/hERG Markov model via substitution of the original HodgkinHuxley-based hERG formulation with a published Markov formulation ([14] and Figure 3 of [12]).”
MethodGeneral structure-free energy relationships of hERG blocker binding under native cellular conditionsPreprint
Wan, H., Spiru, K., Williams, S., & Pearlstein, R. A. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.10.07.463585 · Cited by 3
“The arrhythmic tipping point resides at a dynamic hERG occupancy of 50-60% (depending on the gating cycle length) [10,11] in simulations that we performed previously using a modified version of the O’Hara-Rudy model of the undiseased ventricular AP [8,9].”
MethodPugsley, M. K., Koshman, Y. E., de Korte, T., Authier, S., Winters, B. R., & Curtis, M. J. (2022) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2022.107206 · Cited by 3
Adeniran, I., Wadee, H., & Degens, H. (2024) · BioMed Research International · doi:10.1155/2024/6160554 · Cited by 2
The Impact of Potassium Dynamics on Cardiomyocyte Beating in Hemodialysis Treatment
Hamada, H., Tomo, T., Kim, S., & Yamashita, A. C. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13082289 · Cited by 2
“On the other hand, in the analysis of contraction, we first performed a deterministic numerical simulation of a mathematical model expressing the excitability of ventricular cells developed by the Rudy Group [16], and we obtained changes in cytosol electrolyte concentration during treatment time.”
MethodQauli, A. I., Danadibrata, R. Z., Marcellinus, A., & Lim, K. M. (2024) · Translational and Clinical Pharmacology · doi:10.12793/tcp.2024.32.e7 · Cited by 2
Ruiz, C. R., Gómez, J. F., Mora, M. T., Osca, J., Izquierdo, M., & Trénor, B. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106649 · Cited by 2
Reconstructing ventricular cardiomyocyte dynamics and parameter estimation using data assimilation
Mendez, M. J., Cherry, E. M., Hoeker, G. S., Poelzing, S., & Weinberg, S. H. (2024) · Biophysical Journal · doi:10.1016/j.bpj.2024.10.018 · Cited by 2
Wilders, R. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms252413351 · Cited by 3
Studying ECG signals using nonlinear oscillators and genetic algorithm
Chowdhury, S., Ghosal, A., Roychowdhury, S., & Chaudhuri, I. (2025) · International Journal of Dynamics and Control · doi:10.1007/s40435-025-01610-z · Cited by 2
“O’Hara et al. [22] were successful in simulating the healthy human cardiac ventricular action potential and also verified it experimentally.”
RvD1 and LXA4 inhibitory effects on cardiac voltage-gated potassium channels
de la Cruz, A., Ronchi, C., Bartolucci, C., Socuéllamos, P. G., de Benito-Bueno, Á., Severi, S., Zaza, A., & Valenzuela, C. (2025) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2025.118083 · Cited by 2
Dong, R., Fu, Z., Zhang, C., Liu, Y., Wang, Y., Zhang, N., Wang, Z., Hou, J., Xia, L., Wu, Y., et al. (2025) · Physiological Reports · doi:10.14814/phy2.70435 · Cited by 2
Comparison of Spiral Waves in Simplified Cardiac Tissue Models
Mohanty, S., Prusty, D., & Nayak, A. R. (2025) · Journal of Experimental and Theoretical Physics Letters · doi:10.1134/s0021364025600053 · Cited by 2
Mathematical model of the zebrafish ventricular cardiomyocyte action potential and calcium transient
Cestariolo, L., Long, Z. D., Verkerk, A. O., Ferrero, J. M., Quinn, T. A., & Matas, J. F. R. (2025) · The Journal of Physiology · doi:10.1113/jp287624 · Cited by 2
“The current density of I CaL in the models, however, is higher than for human, with peak and plateau values almost double those found in recent human ventricular AP models (Bartolucci et al., 2020; O’Hara et al., 2011; Tomek et al., 2019), such that it will have a larger direct role in the CaT.”
InfluentialYuniarti, A. R., Marcellinus, A., Qauli, A. I., & Lim, K. M. (2025) · Biomedical Engineering Letters · doi:10.1007/s13534-025-00510-7 · Cited by 2
Zhang, Y., Prakosa, A., Zhang, K., Carrick, R. T., Chrispin, J., Zimmerman, S. L., Aronis, K. N., Kholmovski, E. G., Tichnell, C., Murray, B. A., et al. (2026) · Communications Medicine · doi:10.1038/s43856-026-01662-y · Cited by 2
Cabo, C. (2025) · Physiological Reports · doi:10.14814/phy2.70693 · Cited by 2
“The channel density of I Kr in epicardial cells is about 50% larger than in mid-myocardial cells (O'Hara et al., 2011), which results in the much larger repolarizing current in epicardial cells (Figure 2, top right).”
InfluentialCan in silico models predict drug-induced cardiac risk in vulnerable populations?
Dominguez-Gomez, P., González, P., Baldo-Canut, L., Casoni, E., Amar, A., Pozo, J. M., Butakoff, C., Vázquez, M., & Aguado‐Sierra, J. (2025) · Toxicology Reports · doi:10.1016/j.toxrep.2025.102179 · Cited by 2
“Electrophysiology was modelled using the mon-odomain approximation coupled to the O’Hara-Rudy (ORd) cellular model [49], using a modified version of the ORd model by Passini et al. [33] with modified conductances as described in Dutta et al. [50].”
Okada, J., Fujiu, K., Hasumi, E., Chen, Y., Washio, T., Hisada, T., & Sugiura, S. (2026) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2026.109247 · Cited by 2
Valibeigi, Y., Kaboudian, A., Fenton, F. H., & Bub, G. (2026) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1014590 · Cited by 2
“This tool supports complex models such as Fenton-Karma [32] and O’Hara–Virág–Varró–Rudy (OVVR) [33], enabling dynamic wave propagation to be computed in real-time [34].”
Mikkelsen, C. R., Jornil, J. R., Andersen, L. V., Hasselstrøm, J. B., & Polak, S. (2018) · Toxicology Mechanisms and Methods · doi:10.1080/15376516.2018.1475537 · Cited by 2
Hamada, H., Tomo, T., Kim, S., Hanai, T., Okamoto, M., & Yamashita, A. C. (2020) · Journal of Artificial Organs · doi:10.1007/s10047-020-01207-7 · Cited by 2
Wiśniowska, B., Holbrook, M., Pollard, C. E., & Polak, S. (2022) · Journal of Clinical Pharmacy and Therapeutics · doi:10.1111/jcpt.13762 · Cited by 2
“The optimized IKr-dynamic ORd model proposed by Dutta et al.(21) was not used due to lack of data describing drug block conditions for fenspiride.”
MethodJiang, H., Zhang, S., Lu, W., Yang, F., Bi, X., Ma, W., & Wei, Z. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.1018299 · Cited by 2
“The O’Hara-Rudy dynamics (ORd) model (O’Hara et al., 2011) was utilized to simulate the electrophysiology of human ventricular myocytes in this study.”
MethodAction potential morphology affects T-wave symmetry (simulation study)
Arteyeva, N. V., Komarov, I. A., & Azarov, J. E. (2023) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2023.10.004 · Cited by 2
Biomimetic Cardiac Tissue Models for In Vitro Arrhythmia Studies
Aitova, A. A., Berezhnoy, A., Tsvelaya, V. A., Gusev, O., Lyundup, A. V., Efimov, А. Е., Agapov, I. I., & Игоревич, А. К. (2023) · Biomimetics · doi:10.3390/biomimetics8060487 · Cited by 2
“Cardiac arrhythmia refers to any deviations from the normal electromechanical functioning of the heart, which involves disturbances in the generation and propagation of a cardiac impulse [6]. functioning of the heart, which involves disturbances in the generation and a cardiac impulse [6].”
BackgroundOptimization of a cardiomyocyte model illuminates role of increased INa,L in repolarization reserve
Fullerton, K. E., Clark, A. P., Krogh‐Madsen, T., & Christini, D. J. (2023) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00553.2023 · Cited by 2
Zhang, Y., Toyoda, F., Himeno, Y., Noma, A., & Amano, A. (2024) · Scientific Reports · doi:10.1038/s41598-024-63413-0 · Cited by 2
Cardiac Cellular Electrophysiological Modeling
Tran, K., Pan, M., Hunter, P. J., & Nickerson, D. P. (2024) · Springer eBooks · doi:10.1007/978-3-031-71067-4_12 · Cited by 2
Impact of segregation scheme on performance of a strongly coupled cardiac electromechanical solver
Myklebust, L., Arevalo, H., Daversin, C., Wall, S., & Finsberg, H. N. T. (2025) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2025.118270 · Cited by 2
An analysis of cardiomyocytes’ electrophysiology in the presence of the hERG gene mutations
Glinka, A., & Polak, S. (2013) · Bio-Algorithms and Med-Systems · doi:10.1515/bams-2013-0017 · Cited by 2
“The ORd model couples equations describing ionic channels, pumps, and exchangers with available information on human transmural heterogeneity, cell geometry, and ionic concentrations [18].”
BackgroundMethodAn Introduction to Mathematical and Numerical Modeling of Heart Electrophysiology
Gerardo‐Giorda, L. (2016) · SEMA SIMAI Springer series · doi:10.1007/978-3-319-33054-9_5 · Cited by 2
“Modern detailed ionic models take into account transmembrane current flows, intracellular calcium handling, and can include energetics and force production [15, 41] Higher levels of complexity govern the propagation of the electrical impulse for optimal contraction at the tissue and organ levels.”
Efficient partitioned numerical integrators for myocardial cell models
Spiteri, R. J., & Guo, W. (2019) · Applied Mathematics and Computation · doi:10.1016/j.amc.2019.124738 · Cited by 2
Pires, C. W. S., Vasconcellos, E. C., & Clua, E. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-58799-4_28 · Cited by 2
Computational analysis of vulnerability to reentry in acute myocardial ischemia
Carpio, E. F., Gómez, J. F., Rodríguez, J. F., Trénor, B., & Ferrero, J. M. (2020) · Computing in cardiology · doi:10.22489/cinc.2020.241 · Cited by 2
“Our simulations were performed using a modified version of the O’Hara ventricular action potential model [6], that includes the changes described in our previous work [5].”
MethodRosales, R., Mountris, K. A., Doblaré, M., Mazo, M. M., & Pueyo, E. (2023) · Computing in cardiology · doi:10.22489/cinc.2023.275 · Cited by 2
Interpretation of field and LEAP potentials recorded from cardiomyocyte monolayers
Ernault, A. C., Al‐Shama, R., Li, J., Devalla, H. D., de Groot, J. R., Coronel, R., Vigmond, E. J., & Boukens, B. J. (2024) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00463.2023 · Cited by 2
Nozaleda, G. L., Poloni, S., Soliveri, L., & Valen‐Sendstad, K. (2024) · Simula SpringerBriefs on computing · doi:10.1007/978-3-031-53145-3_7 · Cited by 2
Zaniboni, M. (2024) · Physiological Reports · doi:10.14814/phy2.70085 · Cited by 2
“Thus, by means of one of the most affirmed models of the human cardiac ventricular AP (O'Hara et al., 2011, Ord model) I introduce here a three-dimensional AP representation showing the time-evolution of quasi-instantaneous IV curves during repolarization, IVT-surface in short.”
InfluentialAl-Ali, S., Mora, M. T., Sermesant, M., Trénor, B., & Balelli, I. (2024) · Computing in cardiology · doi:10.22489/cinc.2024.408 · Cited by 2
Dominant ionic currents in rabbit ventricular action potential dynamics
Yang, Z., Gao, H., Smith, G. L., & Simitev, R. D. (2025) · PLoS ONE · doi:10.1371/journal.pone.0328261 · Cited by 2
Metadata
- Authors
- O'Hara, T., Virág, L., Varró, A., & Rudy, Y.
- Affiliations
- University of Szeged (HU)
- Washington University in St. Louis (US)
- Corresponding author
- Rudy, Yoram
- Venue
- PLoS Computational Biology
- Publisher
- Public Library of Science (PLoS)
- Published
- 2011-05-26
- Volume
- 7
- Issue
- 5
- Pages
- e1002061
- ISSN
- 1553-734X (ISSN-L)
- 1553-7358
- PMC
- PMC3102752
- OpenAlex
- W2115765852
- Cited by
- 1,196
- References
- 110
- Citations by year
- 2026: 50 · 2025: 61 · 2024: 89 · 2023: 102 · 2022: 95 · 2021: 97 · 2020: 118 · 2019: 98 · 2018: 89 · 2017: 100 · 2016: 83 · 2015: 67 · 2014: 63 · 2013: 47 · 2012: 27
- FWCI
- 31.78
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- PLoS Computational Biology (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- SZTE Publicatio Repozitórium (University of Szeged) (acceptedVersion, other-oa)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Science Foundation (0929633)
- American Heart Association
- Fondation Leducq
- Hungarian Scientific Research Fund (OTKA CNK-77855)
- Nemzeti Kutatási és Technológiai Hivatal
- National Institutes of Health
- U.S. Public Health Service (R01-HLR01033343-26)
- National Heart, Lung, and Blood Institute (R01HL049054, R01HL-049054-18, R56HL049054)
- Division of Chemical, Bioengineering, Environmental, and Transport Systems
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion channel regulation and function
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- cardiac electrophysiology models, L-type calcium current, transient outward potassium current, Na+/Ca2+ exchanger, inward rectifier potassium current, action potential duration restitution, rate dependence, early afterdepolarizations, calcium alternans, calcium/calmodulin-dependent protein kinase, SERCA, intracellular sodium, late sodium current, transmural heterogeneity, human ventricular myocytes
- MeSH terms
- Action Potentials, Arrhythmias, Cardiac, Calmodulin, Heart Ventricles, Humans, Models, Cardiovascular, Reproducibility of Results, Sodium Channels, Ventricular Function, Patch-Clamp Techniques, Computational Biology, Calcium Channels, L-Type, Myocytes, Cardiac
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.