Simulation of the Undiseased Human Cardiac Ventricular Action Potential: Model Formulation and Experimental Validation
Open accessThe DOI matches its Crossref record; 110 of the 110 references it cites were found in a registry or an index.
Abstract
Cellular electrophysiology experiments, important for understanding cardiac arrhythmia mechanisms, are usually performed with channels expressed in non myocytes, or with non-human myocytes. Differences between cell types and species affect results. Thus, an accurate model for the undiseased human ventricular action potential (AP) which reproduces a broad range of physiological behaviors is needed. Such a model requires extensive experimental data, but essential elements have been unavailable. Here, we develop a human ventricular AP model using new undiseased human ventricular data: Ca(2+) versus voltage dependent inactivation of L-type Ca(2+) current (I(CaL)); kinetics for the transient outward, rapid delayed rectifier (I(Kr)), Na(+)/Ca(2+) exchange (I(NaCa)), and inward rectifier currents; AP recordings at all physiological cycle lengths; and rate dependence and restitution of AP duration (APD) with and without a variety of specific channel blockers. Simulated APs reproduced the experimental AP morphology, APD rate dependence, and restitution. Using undiseased human mRNA and protein data, models for different transmural cell types were developed. Experiments for rate dependence of Ca(2+) (including peak and decay) and intracellular sodium ([Na(+)](i)) in undiseased human myocytes were quantitatively reproduced by the model. Early afterdepolarizations were induced by I(Kr) block during slow pacing, and AP and Ca(2+) alternans appeared at rates >200 bpm, as observed in the nonfailing human ventricle. Ca(2+)/calmodulin-dependent protein kinase II (CaMK) modulated rate dependence of Ca(2+) cycling. I(NaCa) linked Ca(2+) alternation to AP alternans. CaMK suppression or SERCA upregulation eliminated alternans. Steady state APD rate dependence was caused primarily by changes in [Na(+)](i), via its modulation of the electrogenic Na(+)/K(+) ATPase current. At fast pacing rates, late Na(+) current and I(CaL) were also contributors. APD shortening during restitution was primarily dependent on reduced late Na(+) and I(CaL) currents due to inactivation at short diastolic intervals, with additional contribution from elevated I(Kr) due to incomplete deactivation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 1 Undiseased human ICaL experiments and model validation. A) Experiments: ICaL traces for currents carried by Ca2+ (top), Ba2+ (middle), and Sr2+ (bottom). The voltage protocol is below the Ca2+ traces. Ca2+ current decay was visibly more rapid than decay for Ba2+ or Sr2+ currents. Simulations: ICaL in response to the same voltage protocol with CDI (CDI+VDI, top), and without CDI (VDI-only, bottom). B) Experimental data are on the left (white circles, N = 5, from 3 hearts). Simulation results are on the right (solid lines). FRC is fractional remaining current. Times after peak current shown are from 5 to 55 ms, in 5 ms steps (indicated by arrow). Top left) Experiments showing the voltage and time dependence of FRC with Ba2+ as charge carrier (VDI only). Top right) Simulations of FRC, with n−gate = 0 (representing VDI only; see text and panel E). Bottom left) Experiments showing FRC with Ca2+ as charge carrier (CDI and VDI are concurrent). FRC for CDI+VDI was significantly smaller at more hyperpolarized potentials (Vm = −20 to 0 mV, dashed box) than FRC for VDI-alone. Bottom right) Simulations of FRC with free running n gate, allowing both CDI and VDI to occur. C) Data are from Magyar et al.[11] (black squares), Fulop et al.[12] (black diamonds), and previously unpublished (white circles, N = 5, from 3 hearts). Simulation results are solid lines. From left to right, top to bottom: steady state activation, steady state inactivation, fast time constant for VDI, slow time constant for VDI, relative weight of the fast component for VDI, I–V curve, experiments showing recovery from inactivation, and corresponding simulations. D) Human AP clamp waveform, used to elicit 1 µM nisoldipine sensitive current (ICaL, experiments, left) and comparison to simulations using the same AP clamp (right). E) Schematic diagram for the n gate, representing the fraction of L-type channels undergoing CDI. Calmodulin (CaM) is constitutively attached to the L-type channel. Ca2+ ions bind to CaM (on-rate k1 and off-rate k-1). With Ca2+ ions bound, the Ca2+/CaM/channel complex may activate CDI mode (asterisk and black color indicate CDI activation, on-rate k2 and off-rate k-2).](https://figures.cochat.ai/paper-figures/77154b4d77164fafa05b6b606a19318d/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-1.jpg)
![Figure 2 Undiseased human Ito, INaCa, and IK1 experiments and model validation. A) Ito. Experimental data are white circles (N = 8 from 5 hearts for inactivation time constants, N = 10 from 5 hearts for recovery time constants, N = 9 from 6 hearts for steady state inactivation, and N = 23 from 8 hearts for the I–V curve). Simulation results are solid lines. From left to right, top to bottom: steady state activation, steady state inactivation, fast time constant for inactivation, slow time constant for inactivation (insets show fast and slow recovery from inactivation), relative weight of the fast component for inactivation and the I–V curve (normalized). B) INaCa. Experimental data are digitally averaged time traces (N = 3 from 2 hearts, white circles, gray is standard error of the mean). Simulation results are the solid line. Top) Voltage clamp protocol. Bottom) INaCa in response to the clamp. C) IK1. Experimental data are previously unpublished (white circles, N = 21 from 12 hearts), from Bailly et al.[37] (black squares) and Konarzewska et al.[38](black triangles). Simulation results are solid lines (black, gray and dashed black for [K+]o = 4, 8 and 20 mM). Top left) Voltage and [K+]o dependence of steady state rectification. Top right) Voltage and [K+]o dependence of steady state inactivation. Bottom left) Time constant for inactivation. Bottom right) I–V curve, and its [K+]o dependence.](https://figures.cochat.ai/paper-figures/0607c8584c2240a5b55c36291194fb4c/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-2.jpg)
![Figure 3 Undiseased human IKr and IKs experiments and model validation. A) IKr. Experimental data are white circles (N = 10 from 7 hearts for steady state activation, N = 7 from 3 hearts for activation and from 2 hearts for deactivation time constants and weights, and N = 10 from 7 hearts for tail currents). Simulation results are lines. From left to right, top to bottom: steady state activation, time constant for activation (fast (solid) and slow (dashed) time constants converge), fast time constant for deactivation, slow time constant for deactivation, relative weight of the fast component for deactivation, and the I–V curve for normalized tail currents. B) Activation/deactivation profiles in response to the voltage steps shown (−40 mV holding potential to +30 mV steps of various duration, followed by a return to −40 mV, top right inset). Experiments are above. Simulations are below. Activation is rapid, occurring within tens of milliseconds. Deactivation is slow, occurring after several seconds. C) Human AP clamp waveform (top), used to elicit 1 µM E-4031 sensitive current (IKr, bottom); experiments are on the left, and comparison to simulations using the same AP clamp is on the right. D) IKs. Data are from Virág et al.[41] (black circles). Simulation results are solid lines. From left to right: steady state activation, time constant for activation (much slower than deactivation at depolarized potentials), time constant for deactivation (much faster than activation at hyperpolarized potentials), and the I–V curve, showing normalized tail currents.](https://figures.cochat.ai/paper-figures/e000cfe343c1469d9064b4a0eeb86bd0/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-3.jpg)
![Figure 4 Nonfailing human fast INa and late INa experiments and model validation. A) Fast INa. Experiments are from Sakakibara et al.[44] (black squares) and Nagatomo et al.[45] (black triangles). Simulation results are solid lines. From left to right, top to bottom: steady state activation, time to peak (experiment) and activation time constant (simulation), steady state inactivation, fast time constant for development of inactivation, slow time constant for development of inactivation, time constant for recovery from inactivation, and the I–V curve (solid line simulation and data at 17°C, dashed line simulation at 37°C). In other panels, simulations and data were adjusted to 37°C. Time to peak was fit at 33°C. B) Late INa. Experiments are from Maltsev et al.[51] (black squares). Simulation results are solid lines. Top) Steady state activation. Middle) Steady state inactivation. Bottom) I–V curve.](https://figures.cochat.ai/paper-figures/1bc72be1ff78416eb0539041b17ce71d/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-4.jpg)


![Figure 7 Undiseased human endocardial AP response to pacing protocols from experiments (small tissue preparations) and model simulations. A) Steady state APD rate dependence. B) S1S2 APD restitution (DI – diastolic interval). APD30–90 are labeled at right. Solid lines are simulation results; white squares are experiments at 37°C (N = 140 hearts in panel A, N = 50 hearts in panel B). C) Repolarization rate at CL = 1000 ms. Trajectory of APD30 to APD90 is accurate in the ORd model (white squares are experimental data); less so in other models. D) Dynamic restitution protocol (see Methods). Experiments are from Koller et al.[58], measured in nonfailing human hearts with monophasic AP electrodes (black squares). Simulated results are the black line. At very short diastolic intervals (DI<90 ms), the model shows APD bifurcation (alternans).](https://figures.cochat.ai/paper-figures/5bf8b14e1f23445fbe171a340c65ec27/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-7.jpg)


![Figure 10 Transmural heterogeneity and validation of transmural cell type models. A–C) Expression ratio in the model (black bars) compared to experimental data from undiseased human hearts (grayscale bars, labeled). D) Transmural heterogeneity of Ito; simulations are lines, experiments are squares. Results for endo are gray; those for epi are black. E1) Rate dependence of APD90 in endo, M, and epi cell types. Epi and M data were obtained by scaling endo data (white squares) by epi/endo and M/endo APD90 ratios from Drouin et al.[50] (black squares). Simulations are black lines. E2) Same format as panel E1, showing epi APD90 at faster pacing rates. Data are from Glukhov et al.[71], (epi/endo scaling, black triangles). F) Top to bottom: Rate-dependence of endo, M, and epi APs. G) Pseudo-ECG, using a simulated transmural wedge. CL changes are indicated by arrows.](https://figures.cochat.ai/paper-figures/1858cf93ccb24d138364411aa9171594/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-10.jpg)
![Figure 11 Early afterdepolarizations (EADs). A) Top left) Experiments in isolated nonfailing human endo myocytes from Guo et al.[73] showed EADs with slow pacing (CL = 4000 ms) in the presence of IKr block (0.1 µM dofetilide, ∼85% IKr block[74], reproduce with permission). Top right) Following the experimental protocol of Guo et al. (CL = 4000 ms, 85% IKr block) the ORd model accurately showed a single large EAD. Bottom) GB (left) and TP (right) models failed to generate EADs (CL = 4000 ms, even with 100% IKr block). B) EAD mechanism. APs are on top. ICaL (black) and ICaL recovery gate (gray) are below. Slow pacing alone (CL = 4000 ms) did not cause an EAD (left). Slow pacing plus IKr block (85%) caused an EAD (solid lines, right). The EAD was depolarized by ICaL reactivation during the slowly repolarizing AP plateau (solid lines, solid arrows). When ICaL recovery was prevented, the EAD was eliminated (dashed lines and dashed arrow).](https://figures.cochat.ai/paper-figures/f149e810e43a4018aa88d922b48d5501/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-11.jpg)
![Figure 12 Rate dependence of intracellular ion concentrations. Simulation results are solid lines. A) [Na+]i versus pacing frequency (normalized to 0.25 Hz). Experiments are from nonfailing myocytes (Pieske et al.[57], black squares). B) Peak Ca2+ transient (normalized to 0.5 Hz). Experiments are from nonfailing myocytes (Schmidt et al.[76], black squares). C) Ca2+ transients from experiments (Fura-2-AM) and simulations. Results are normalized to illustrate the time course of decay. The arrow indicates pacing CL changes. D) Frequency dependent acceleration of relaxation. Undiseased human experimental data are white circles. Simulations are the black line.](https://figures.cochat.ai/paper-figures/ef54eb92e96d49ff88664d97c8a51055/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-12.jpg)
![Figure 13 CaMK and Ca2+ cycling. A) Rate dependence of CaMK active fraction. B) Ca2+ cycling under control conditions (left) and without CaMK (right). CL changes are indicated by arrows. Top) [Ca2+]i and diastolic values (inset). Middle) [Ca2+]JSR. Bottom) Jup and Jrel (inset, expanded time scale).](https://figures.cochat.ai/paper-figures/e1891823cb1c44268191312b4fe6d66e/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-13.jpg)
![Figure 14 AP and Ca2+ alternans at fast pacing. Black lines are control. Gray lines are without CaMK. The two consecutive beats are labeled 1 and 2. A) Pacing at CL = 250 ms. From left to right, top to bottom: AP, expanded time scale showing AP repolarization, Jrel (inset is expanded time scale), [Ca2+]i, [Ca2+]JSR, and Jup. B) Rate dependence of APD (top) and peak [Ca2+]i (bottom) at fast rates (alternans bifurcations disappear without CaMK). C) Same as panel B, but at slower rates (no bifurcations).](https://figures.cochat.ai/paper-figures/eac046432d3a40d7b4647ffa370f37f5/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-14.jpg)

![Figure 16 Major causes of steady state APD rate dependence and S1S2 APD restitution. A) APD rate dependence in control (solid black), and with [Na+]i and [Na+]ss clamped to slow rate (solid gray) or fast rate (dashed black) values. When late INa (dashed gray) or both late INa and ICaL inactivation gates were reset to their slow rate values (dash-dot-dot gray) in addition to [Na+]i and [Na+]ss slow rate clamp, APD lost almost all rate dependence. Note that slow rate [Na+]i and [Na+]ss clamp alone left residual APD rate dependence, especially at fast rates (CL = 300 to 700 ms, shaded box). B) APD rate dependence (control, solid black) was largely unaffected by resetting inactivation gates for late INa (dashed gray), ICaL (dash-dot-dot gray), or late INa and ICaL (solid gray) to their slow rate values (no [Na+]i and [Na+]ss clamping to slow rate values). C) [Na+]i and INaK increase with pacing rate under control conditions (left). When [Na+]i and [Na+]ss are clamped to slow rate values, INaK is small and rate independent (right). D) APD restitution in control (solid black), and when inactivation gates were reset to S1 values upon S2 delivery (late INa reset – dashed gray, ICaL reset – dash-dot-dot gray, late INa and ICaL reset – solid gray). Shown in dashed black is resetting late INa and ICaL inactivation to the DI = 5 ms value. E) [Na+]i and [Na+]ss clamp to S1 values (dashed gray) did not affect APD restitution (control, solid black).](https://figures.cochat.ai/paper-figures/48cb13a7d63148b88e1f1a1a957108d3/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-16.jpg)

![Figure 18 Comparison with other human ventricular AP models. Single endo cell simulations from ORd, TP, and GB models are solid black, gray, and dashed black lines, respectively. Experimental results (small tissue preparations) are white squares. A) APD rate dependence. Results for APD90, 70, 50 and 30 are shown top left, top right, bottom left, and bottom right, respectively. B) The AP, major currents, [Na+]i, and [Ca2+]i at steady state for CL = 1000 ms. From left to right, top to bottom: AP (with Vm rest inset at far right), INa (inset shows peaks), late INa (not present in TP or GB models), Ito (inset shows decay rate), ICaL (arrow shows ORd peak magnitude; inset shows normalized peaks, which are wide in TP and GB), IKr (arrow shows ORd early spike peak magnitude), IKs, IK1, INaCa, INaK, [Ca2+]i, [Ca2+]i decay rate, and [Na+]i.](https://figures.cochat.ai/paper-figures/ed5768b836094b8fa6a37c72910bad90/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-18.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“For subject-specific virtual patients, it may be possible to collect pre- and post-intervention data from the same subject, enabling validation of both the virtual patient in isolation and the coupled device-patient model (Fig 2d; see [56] for an example in stent-graft deployment)”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [56]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Calmodulin kinase determines calcium-dependent facilitation of L-type calcium channels
Dzhura, I., Wu, Y., Colbran, R. J., Balser, J. R., & Anderson, M. E. (2000) · Nature Cell Biology · doi:10.1038/35004052 · Cited by 335 · cited 1×
“dog ICaL model[19] and as measured experimentally[21].”
RetractedCoassembly of KVLQT1 and minK (IsK) proteins to form cardiac IKS potassium channel
Sanguinetti, M. C., Curran, M. E., Zou, A., Shen, J., Specter, P. S., Atkinson, D. L., & Keating, M. T. (1996) · Nature · doi:10.1038/384080a0 · Cited by 1,764 · cited 1×
“. The presence of KCNE1 carries two important functional consequences 1) ∼5 fold slower activation and 2) ∼5 fold larger conductance”
Luo, C. H., & Rudy, Y. (1994) · Circulation Research · doi:10.1161/01.res.74.6.1071 · Cited by 1,589 · cited 1×
“guinea pig predecessor[80].”
Self-citationLuo, C. H., & Rudy, Y. (1991) · Circulation Research · doi:10.1161/01.res.68.6.1501 · Cited by 1,468 · cited 12×
“ON NA+ HANDLING, INAK AND APD RATE DEPENDENCE .......................................................... 32 EFFECT OF KCNE1 HETEROGENEITY ON TRANSMURAL IKS AND AP SIMULATIONS ..................................................................... 33 APD ACCOMMODATION .....................................................…”
BackgroundInfluentialSelf-citationSanguinetti, M. C., & Jurkiewicz, N. K. (1990) · The Journal of general physiology · doi:10.1085/jgp.96.1.195 · Cited by 1,457
A model for human ventricular tissue
ten Tusscher, K. H. W. J., Noble, D., Noble, P. J., & Panfilov, A. V. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00794.2003 · Cited by 1,416 · cited 1×
“The TP model[81] and updated”
Alternans and spiral breakup in a human ventricular tissue model
ten Tusscher, K. H. W. J., & Panfilov, A. V. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00109.2006 · Cited by 1,122 · cited 5×
“Rate dependence in the TP model[9] is less [Na]i dependent because, as Grandi discussed[10], IKs is exaggerated.”
InfluentialCalmodulin Is the Ca2+ Sensor for Ca2+-Dependent Inactivation of L-Type Calcium Channels
Peterson, B. Z., DeMaria, C. D., & Yue, D. T. (1999) · Neuron · doi:10.1016/s0896-6273(00)80709-6 · Cited by 856
Cellular Basis for the Electrocardiographic J Wave
Yan, G.-X., & Antzelevitch, C. (1996) · Circulation · doi:10.1161/01.cir.93.2.372 · Cited by 812
Wehrens, X. H. T., Lehnart, S. E., Reiken, S. R., & Marks, A. R. (2004) · Circulation Research · doi:10.1161/01.res.0000125626.33738.e2 · Cited by 623 · cited 1×
“Wehrens et al.[96] with KN-93 in rabbit) should be performed in human ventricular myocytes to validate model predictions.”
Method
Cited by
Items 701–800 of 1,000
Woodworth, L. A., Cansız, B., & Kaliske, M. (2022) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3589 · Cited by 6
Jian, K., Li, C., Hancox, J. C., & Zhang, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.877428 · Cited by 6
Zhou, H., Zhang, Z., Zhu, L., Li, P., Hong, S., Liu, L., & Liu, X. (2022) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2022.116312 · Cited by 6
Weinberg, S. H. (2023) · The Journal of General Physiology · doi:10.1085/jgp.202313382 · Cited by 6
Sönmez, M. I., Goldack, S., Nurkkala, E., Schulz, C., Klampe, B., Schulze, T., Hansen, A., Eschenhagen, T., Koivumäki, J. T., & Christ, T. (2024) · EP Europace · doi:10.1093/europace/euae140 · Cited by 6
Development and Clinical Validation of a Cross-Sex Translator of ECG Drug Responses
Shetty, R., Morotti, S., Sobota, V., Bayer, J. D., Ni, H., & Grandi, E. (2025) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2025.05.015 · Cited by 6
Zhou, X., Bueno‐Orovio, A., Orini, M., Hanson, B. M., Hayward, M. P., Taggart, P. I., Lambiase, P. D., Burrage, K., & Rodríguez, B. (2013) · Oxford University Research Archive (ORA) (University of Oxford) · Cited by 6
Conditions for Waveblock Due to Anisotropy in a Model of Human Ventricular Tissue
Kudryashova, N., Kazbanov, I. V., Panfilov, A. V., & Игоревич, А. К. (2015) · PLoS ONE · doi:10.1371/journal.pone.0141832 · Cited by 6
Pérez‐Zabalza, M., Diez, E. R., Rhyins, J., Mountris, K. A., Vallejo‐Gil, J. M., Fresneda‐Roldán, P. C., Fañanás‐Mastral, J., Matamala‐Adell, M., Sorribas-Berjón, F., Vázquez‐Sancho, M., et al. (2020) · Computing in cardiology · doi:10.22489/cinc.2020.427 · Cited by 6
“The O’Hara-Virág-VarróRudy human ventricular action potential (AP) model [5] was used to simulate endocardial, midmyocardial and epicardial cardiomyocytes in a spatial configuration as reported experimentally [6].”
MethodA stable cell line inducibly expressing hERG1a/1b heteromeric channels
Pérez, E. B. R., Liu, F., Stevens-Sostre, W. A., Eichel, C. A., Silignavong, J., & Robertson, G. A. (2021) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2021.107081 · Cited by 6
“For all simulations we selected the version of the O’Hara-Rudy-CiPA model (Rudy et al., 2011) described by Dutta et al.”
MethodMountris, K. A., & Pueyo, E. (2021) · Mechanisms and machine science · doi:10.1007/978-3-030-67090-0_4 · Cited by 6
Computationally efficient model of myocardial electromechanics for multiscale simulations
Syomin, F. A., Osepyan, A., & Tsaturyan, A. K. (2021) · PLoS ONE · doi:10.1371/journal.pone.0255027 · Cited by 6
Image-based Cardiac Electrophysiology Simulation through the Meshfree Mixed Collocation Method
Mountris, K. A., Doblare, M., & Pueyo, E. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630632 · Cited by 6
“Cell electrophysiology was described by the O’Hara model [11].”
MethodModel-based analysis of myocardial strains in left bundle branch block
Taconné, M., Owashi, K. P., Galli, E., Duchenne, J., Hubert, A., Donal, E., Hernandez, A. I., & Rolle, V. L. (2022) · Frontiers in Applied Mathematics and Statistics · doi:10.3389/fams.2022.833003 · Cited by 6
Bukhari, S. H. A., Sánchez, C., Laguna, P., Potse, M., & Pueyo, E. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1060919 · Cited by 6
“Initially, we considered the O’Hara-Rudy model (O’Hara et al., 2011) and the Grandi-Pasqualini-Bers model (Grandi et al., 2010), but these models had limitations with respect to the simulation of hyperkalemic effects in tissues, as they did not show propagation of excitation for [ K + ] values…”
Interindividual Age-Independent Differences in Human CX43 Impact Ventricular Arrhythmic Risk
García‐Mendívil, L., Pérez‐Zabalza, M., Oliver-Gelabert, A., Vallejo‐Gil, J. M., Fañanás‐Mastral, J., Vázquez‐Sancho, M., Bellido‐Morales, J. A., Vaca‐Núñez, A. S., Ballester, C., Diez, E. R., et al. (2023) · Research · doi:10.34133/research.0254 · Cited by 6
“The O’Hara–Rudy model was used to describe the human ventricular action potential for the 2 types of cells [60].”
MethodBódi, I., Mettke, L., Michaelides, K., Hornyik, T., Meier, S., Nimani, S., Perez‐Feliz, S., El‐Battrawy, I., Bugger, H., Zehender, M., et al. (2024) · Cardiovascular Research · doi:10.1093/cvr/cvae149 · Cited by 6
“(N588K) SQT1 and WT formulations of I Kr from Loewe et al. 23 were embedded in the O’Hara-Rudy human ventricular AP computational model 24 to simulate WT and SQT1 conditions in the absence or presence of L-Carnitine treatment at the cellular and 2D tissue levels (see Supplementary material online,…”
MethodPassini, E., & Severi, S. (2012) · Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) · Cited by 6
Smith, J. L., Tester, D. J., Hall, A. R., Burgess, D. E., Hsu, C., Elayi, C. S., Anderson, C. L., January, C. T., Luo, J. Z., Hartzel, D. N., et al. (2018) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.117.005859 · Cited by 6
Kojima, A., Fukushima, Y., Itoh, H., Imoto, K., & Matsuura, H. (2020) · European Journal of Pharmacology · doi:10.1016/j.ejphar.2020.173378 · Cited by 6
Sampedro-Puente, D. A., Raphel, F., Fernández-Bes, J., Laguna, P., Lombardi, D., & Pueyo, E. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2984647 · Cited by 6
“plausible limits were retained, with those limits shown in Table 1 as determined based on [39], [42]–[47].”
A novel mutation in KCNH2 yields loss-of-function of hERG potassium channel in long QT syndrome 2
Gu, K., Qian, D., Qin, H., Cui, C., Fernando, W., Wang, D. W., Wang, J., Cao, K., & Chen, M. (2021) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-021-02518-1 · Cited by 6
Kimrey, J., Vo, T., & Bertram, R. (2022) · SIAM Journal on Applied Dynamical Systems · doi:10.1137/22m147757x · Cited by 6
Accelerating Detailed Tissue-Scale 3D Cardiac Simulations Using Heterogeneous CPU-Xeon Phi Computing
Langguth, J., Lan, Q., Gaur, N., & Cai, X. H. (2016) · International Journal of Parallel Programming · doi:10.1007/s10766-016-0461-2 · Cited by 6
“Tomimic the human cardiac ventricular tissue, we replace the electrophysiological current formulation of [11],whichmodels a guinea pig,with theO’Hara-Rudy (ORd) model [22] of a healthy human cardiac ventricular action potential.”
MethodBohannon, B. M., de la Cruz, A., Wu, X., Jowais, J. J., Perez, M. E., Dykxhoorn, D. M., Liin, S. I., & Larsson, H. P. (2020) · eLife · doi:10.7554/elife.60141 · Cited by 6
Hancox, J. C., Wang, Y., Copeland, C. S., Zhang, H., Harmer, S. C., & Henderson, G. (2024) · Journal of Molecular and Cellular Cardiology Plus · doi:10.1016/j.jmccpl.2024.100118 · Cited by 5
Mechanisms of Chemical Atrial Defibrillation by Flecainide and Ibutilide
Yang, P., Belardinelli, L., & Clancy, C. E. (2024) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2024.08.009 · Cited by 5
“43 Our study received the proper ethical oversight because no animals or humans were used.”
Kitajima, H., Yazawa, T., & Barrio, R. (2024) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/5.0230834 · Cited by 5
Tsumoto, K., Shimamoto, T., Aoji, Y., Himeno, Y., Kuda, Y., Tanida, M., Amano, A., & Kurata, Y. (2025) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2025.108587 · Cited by 5
Hanum, U. L., Qauli, A. I., Fuadah, Y. N., Izza, R. N., & Lim, K. M. (2025) · Archives of Toxicology · doi:10.1007/s00204-025-04079-z · Cited by 5
Morier, M., Padilla, J. R., Gallinari, P., & Sermesant, M. (2025) · Lecture notes in computer science · doi:10.1007/978-3-031-94559-5_13 · Cited by 5
“High-fidelity models, such as Ten Tusscher-Panfilov [2] or O’Hara-Rudy [3] are accurate but computationally expensive.”
Pikunov, A. V., Syunyaev, R. A., Ali, R. L., Prakosa, A., Gams, A., Boyle, P. M., Steckmeister, V., Kutschka, I., Rytkin, E., Voigt, N., et al. (2025) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.125.013898 · Cited by 5
Moise, N., Struckman, H. L., Smyth, J. W., Hoeker, G. S., Poelzing, S., Veeraraghavan, R., & Weinberg, S. H. (2026) · The Journal of Physiology · doi:10.1113/jp290135 · Cited by 6
Elevation of propofol sensitivity of cardiac IKs channel by KCNE1 polymorphism D85N
Kojima, A., Mi, X., Fukushima, Y., Ding, W., Omatsu‐Kanbe, M., & Matsuura, H. (2021) · British Journal of Pharmacology · doi:10.1111/bph.15460 · Cited by 5
“Finally, we simulated the effect of propofol on ventricular APD and QTc interval under conditions of wild-type (KCNQ1/KCNE1) or homozygous KCNQ1/KCNE1-D85N IKs using the Mann-revised ORd model without and with β-adrenoceptor stimulation (Mann et al., 2016; O'Hara et al., 2011).”
MethodRodríguez-Belenguer, P., Kopańska, K., Llopis‐Lorente, J., Trénor, B., Sáiz, J., & Pastor, M. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107345 · Cited by 5
Hwang, M., Lee, S.-J., Lim, C.-H., Shim, E. B., & Lee, H. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1123190 · Cited by 5
A Coupling Physics Model for Real-Time 4D Simulation of Cardiac Electromechanics
Chen, R., Cui, J., Li, S., & Hao, A. (2024) · Computer-Aided Design · doi:10.1016/j.cad.2024.103747 · Cited by 5
Prediction of excitable wave dynamics using machine learning
Mulimani, M. K., Echeverría-Alar, S., Reiß, M., & Rappel, W. (2025) · Chaos Solitons & Fractals · doi:10.1016/j.chaos.2025.115990 · Cited by 5
Computational modeling of post-myocardial infarction arrhythmias: Insights and predictions
Villar‐Valero, J., Gómez, J. F., Soto‐Iglesias, D., Penela, D., Berruezo, A., & Trénor, B. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110894 · Cited by 5
Silent mutation in long QT syndrome: Pathogenicity prediction by computer simulation
Bhuiyan, Z. A. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.10.012 · Cited by 5
Lan, Q., Gaur, N., Langguth, J., & Cai, X. H. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-27137-8_7 · Cited by 5
“The whole-cell values are consistent with [14].”
MethodResultInfluentialNieto-Marín, P., Jiménez‐Jáimez, J., Tinaquero, D., Alfayate, S., Utrilla, R. G., del Rey, M. D. M. R. V., Perín, F., Sarquella‐Brugada, G., Monserrat, L., Brugada, J., et al. (2018) · Revista Española de Cardiología · doi:10.1016/j.recesp.2018.03.009 · Cited by 5
Sampedro-Puente, D. A., Fernández-Bes, J., Virág, L., Varró, A., & Pueyo, E. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2921881 · Cited by 5
“A set of AP models was built based on the ORd human ventricular epicardial model [32].”
BackgroundMethodInfluentialSelf-citationEvaluating sequential and allosteric activation models in I Ks channels with mutated voltage sensors
Fedida, D., Sastre, D., Dou, Y., Westhoff, M., & Eldstrom, J. (2024) · The Journal of General Physiology · doi:10.1085/jgp.202313465 · Cited by 5
Arts, T. G. J., Lyon, A., Delhaas, T., Kuster, D. W. D., van der Velden, J., & Lumens, J. (2024) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2024.03.001 · Cited by 5
Cairns, D. I., Comstock, M. R., Fenton, F. H., & Cherry, E. M. (2025) · Royal Society Open Science · doi:10.1098/rsos.250048 · Cited by 5
Shimayoshi, T., Cha, C. Y., & Amano, A. (2015) · PLoS ONE · doi:10.1371/journal.pone.0124970 · Cited by 5
“The present method is applicable to recent and complicated ventricular myocyte models [23, 24], although rather simple models analysed in this paper are suitable for the initial demonstration of the proposed method.”
MethodPaci, M., Severi, S., & Hyttinen, J. (2014) · Computing in cardiology · Cited by 5
Hoshi, M., Liu, H., Kaufman, E. S., & Deschênes, I. (2015) · HeartRhythm Case Reports · doi:10.1016/j.hrcr.2015.02.011 · Cited by 5
“Simulated effect of mutations on action potential duration To further explore which mutation(s) was needed to explain the presence of LQT in the proband, we simulated the effects of the mutations on the human ventricular action potential in silico.(9) SCN5A-F1596I was defined as an 80% increase in late current, aþ5-mV…”
Extracellular calcium and L-type calcium current inactivation mechanisms: A computational study
Passini, E., & Severi, S. (2013) · Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) · Cited by 5
Heterogeneous electrical remodeling of the failing heart modulates the arrhythmogenic substrate
Gómez, J. F., Cardona, K., Romero, L., Sáiz, J., & Trénor, B. (2013) · Computing in cardiology · Cited by 5
Development of a novel Markov chain model for oxidative-dependent CaMKIIδ activation
Zhang, S., Li, Q., Zhou, L., Wang, K., & Zhang, H. (2015) · Computing in cardiology · doi:10.1109/cic.2015.7411052 · Cited by 5
“With respect to how CaMKII affects ion channels, we adopted a formulation developed by O'Hara et al. [5].”
MethodGong, J. Q. X., Shim, J. V., Núñez-Acosta, E., & Sobie, E. A. (2016) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2016.10.015 · Cited by 5
Simulation study of the ionic mechanisms underlying Torsade de Pointes in a 2D cardiac tissue
Priya, P. K., & Reddy, M. R. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.08.017 · Cited by 5
Humans Vary, So Cardiac Models Should Account for That Too!
Wiśniowska, B., Tylutki, Z., & Polak, S. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00700 · Cited by 5
“The O’Hara-Rudy (ORd) model was chosen as the starting point for developing an in silico model with the ultimate aim of providing a system suitable for regulatory decision making (O’Hara et al., 2011).”
BackgroundMethodZaniboni, M., & Cacciani, F. (2019) · EP Europace · doi:10.1093/europace/euz205 · Cited by 5
Zimik, S., Pandit, R. A., & Majumder, R. (2020) · PLoS ONE · doi:10.1371/journal.pone.0230214 · Cited by 5
“We initiate such a study by examining the effects of this type of heterogeneity in three cardiac-tissue models, which are, in order of increasing complexity and biological realism, (a) the two-variable Aliev-Panfilov model [33], (b) the ionically realistic O’Hara-Rudy (ORd) model [34] in two dimensions (2D), and (c) t…”
MethodQauli, A. I., Marcellinus, A., & Lim, K. M. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.697693 · Cited by 5
Simulation Modeling of Reduced Glycosylation Effects on Potassium Channels of Mouse Cardiomyocytes
Kim, H., Yang, H. Y., Ednie, A. R., & Bennett, E. S. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.816651 · Cited by 5
Phadumdeo, V. M., Mallare, B. L., Hund, T. J., & Weinberg, S. H. (2023) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00220.2023 · Cited by 5
Spiral-wave dynamics in excitable media: Insights from dynamic mode decomposition
Mulimani, M. K., Zimik, S., Alageshan, J. K., & Pandit, R. A. (2023) · Communications in Nonlinear Science and Numerical Simulation · doi:10.1016/j.cnsns.2023.107428 · Cited by 5
“The first is the set of twovariable coupled partial differential equations (PDEs) called the Barkley model [27]; and the second is the biophysically realistic O’Hara-Rudy (ORd) model [28].”
MethodGintant, G. A., & Braam, S. R. (2016) · Methods in pharmacology and toxicology · doi:10.1007/978-1-4939-6661-5_1 · Cited by 5
Wilders, R. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01795 · Cited by 5
“, 2014), where it is responsible for the fast >150 V/s upstroke of individual atrial and ventricular cardio-myocytes (Workman et al., 2001; O’Hara et al., 2011).”
BackgroundFrom Single Myocyte to Whole Heart: The Intricate Dance of Electrophysiology and Modeling
Despa, S. I., & Vigmond, E. J. (2016) · Circulation Research · doi:10.1161/circresaha.115.308067 · Cited by 5
Cluitmans, M. J. M. (2016) · Research Publications (Maastricht University) · doi:10.26481/dis.20160929mc · Cited by 5
A bond graph approach to integrative biophysical modelling
Pan, M. (2019) · Minerva Access (University of Melbourne) · Cited by 6
T-World: A highly general computational model of a human ventricular myocytePreprint
Tomek, J., Zhou, X., Martinez‐Navarro, H., Holmes, M., Bury, T. M., Berg, L. A., Tomková, M., Jo, E., Nagy, N., Bertrand, A., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.03.24.645031 · Cited by 5
“The model utilises a range of new developments, as well as components and ideas from two influential modelling families from the Rudy 4,19 and Grandi and Bers labs 11,12 .”
InfluentialThe shifting landscape of safety pharmacology in 2015
Pugsley, M. K., Authier, S., Stonerook, M., & Curtis, M. J. (2015) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2015.05.013 · Cited by 5
Sobota, V., Stoks, J., Patel, K. H. K., Shetty, R., Ni, H., Grandi, E., Ng, F. S., Volders, P. G. A., Cluitmans, M. J. M., & Bayer, J. D. (2025) · The Journal of Physiology · doi:10.1113/jp288356 · Cited by 4
“1 B ; O’Hara et al., 2011; Peirlinck et al., 2021) were incorporated into both models.”
Bertrand, A., Tomek, J., & Rodríguez, B. (2026) · The Journal of Physiology · doi:10.1113/jp287140 · Cited by 5
“…and Panfilov, Grandi et al., O’Hara et al. for human ventricular electrophysiology and excitation–contraction coupling (Grandi et al., 2010; T. O’Hara et al., 2011; ten Tusscher & Panfilov, 2006), β -adrenergic stimulation (Heijman et al., 2011), contractility (Coppini et al., 2019; Land…”
Liu, J., Bayer, J. D., Aschar‐Sobbi, R., Wauchop, M., SPEARS, D. A., Gollob, M. H., Vigmond, E. J., Tsushima, R. G., Backx, P. H., & Chauhan, V. S. (2018) · PLoS ONE · doi:10.1371/journal.pone.0197273 · Cited by 4
Balakina-Vikulova, N. A., Solovyova, O. E., Panfilov, A. V., & Katsnelson, L. B. (2018) · Computing in cardiology · doi:10.22489/cinc.2018.065 · Cited by 4
“Several reputed models of the human cardiomyocytes describe electrophysiological function of the cells [1-5].”
BackgroundAbraham, E. U., Welch, B. A., Kilic, A., & Kung, E. O. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.111391 · Cited by 4
A study of early afterdepolarizations in human ventricular tissue
Vandersickel, N., & Panfilov, A. V. (2015) · Computing in cardiology · doi:10.1109/cic.2015.7411135 · Cited by 4
“Here, we extend our studies to an anatomically accurate model of human ventricles and study the possible types of excitation patterns that can be observed there.”
BackgroundIn-silico Research Platform in the Cloud - Performance and Scalability Analysis
Ivanovic, M. R., Živić, A., Tachos, N. S., Gois, G., Filipović, N., & Fotiadis, D. I. (2021) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe52308.2021.9635574 · Cited by 4
“…resources: 1) O’Hara - O’Hara model provides Calcium concentration given the parameters such as rate constant for de-phosphorylation, fraction of active binding sites with a Ca 2+ /calmodulin complex on them, rate constant for calmodulin complex binding to CaMK , as explained in [6] and [3].”
Novaes, G. M., Álvarez-Lacalle, E., Alonso, S., & dos Santos, R. W. (2022) · PLoS ONE · doi:10.1371/journal.pone.0266233 · Cited by 4
Albors, C., Lluch, È., Gómez, J. F., Cedilnik, N., Mountris, K. A., Mansi, T., Khamzin, S., Dokuchaev, A., Solovyova, O. E., Pueyo, E., et al. (2022) · Applied Sciences · doi:10.3390/app12136438 · Cited by 4
Assessing drug safety by identifying the axis of arrhythmia in cardiomyocyte electrophysiology
Heitmann, S., Vandenberg, J. I., & Hill, A. P. (2023) · eLife · doi:10.7554/elife.90027.3 · Cited by 4
Optogenetic Modulation of Arrhythmia Triggers: Proof-of-Concept from Computational Modeling
Ochs, A., & Boyle, P. M. (2023) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-023-00781-z · Cited by 4
“(ORd) [56] in all cell and organ-scale simulations.”
BackgroundMethodKaboudian, A., Cherry, E. M., & Fenton, F. H. (2023) · Computing in cardiology · doi:10.22489/cinc.2023.136 · Cited by 4
“For this example, we used the 41-variable OVVR model [16] as the cell model.”
MethodInfluentialIn Silico Human Cardiomyocyte Action Potential Modeling: Exploring Ion Channel Input Combinations
Boulay, E., Troncy, É., Jacquemet, V., Huang, H., Pugsley, M. K., Downey, A.-M., Baca, R. V., & Authier, S. (2024) · International Journal of Toxicology · doi:10.1177/10915818241237988 · Cited by 4
Nakajima, T., Tamura, S., Kawabata‐Iwakawa, R., Itoh, H., Hasegawa, H., Kobari, T., Harasawa, S., Sekine, A., Nishiyama, M., Kurabayashi, M., et al. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1401822 · Cited by 4
Computational analysis of long QT syndrome type 2 and the therapeutic effects of KCNQ1 antibodies
Pan, Z., Fu, Q., Jiang, H., Wei, Z., & Zhang, S. (2024) · Digital Health · doi:10.1177/20552076241277032 · Cited by 4
Gómez-Gómez, M., Carro, J., Pueyo, E., Pérez, A., Oliván‐Viguera, A., & Monasterio, V. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3495027 · Cited by 4
Fijorek, K., Tanner, F. C., Stähli, B. E., Gielerak, G. G., Krzesiński, P., Uziębło‐Życzkowska, B., Smurzyński, P., Stańczyk, A., Stolarz‐Skrzypek, K., Kawecka−Jaszcz, K., et al. (2014) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-014-9558-4 · Cited by 4
“In BDMMs, the heart wall is assumed to be equivalent to the one-dimensional string of virtual cardiomyocyte cells, and the heart wall thickness is assumed to be equivalent to the length of the string of virtual cells [14–16].”
BackgroundBritton, O. J., Bueno‐Orovio, A., Virág, L., Varró, A., & Rodríguez, B. (2014) · Computing in cardiology · Cited by 4
Self-citationModules for Reusable and Collaborative Modelling of Biological Mathematical Systems
Gill, M., McKeever, S., & Gavaghan, D. J. (2012) · IEEE International Conference on Enabling Technologies: Infrastructure for Collaborative Enterprises (WETICE) · doi:10.1109/wetice.2012.86 · Cited by 4
Passini, E., Rodríguez, B., Mincholé, A., Coppini, R., Cerbai, E., Severi, S., & Bueno‐Orovio, A. (2014) · Computing in cardiology · Cited by 4
Models of the Ventricular Action Potential in Health and Disease
Grandi, E., & Bers, D. M. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4557-2856-5.00032-7 · Cited by 4
Inward rectifying potassium currents resolved into components: modeling of complex drug actions
Šimurda, J., Šimurdová, M., & Bébarová, M. (2017) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-017-2071-2 · Cited by 4
GPU-based Acceleration of Detailed Tissue-Scale Cardiac Simulations
Altanaite, N., & Langguth, J. (2018) · doi:10.1145/3180270.3180274 · Cited by 4
“Moreover, we combine it with the O’Hara-Rudy (ORd) model [16] to reproduce the cardiac ventricular action potential of a healthy human heart.”
MethodThe Arrhythmogenic Effect of Protein-Bound Uremic Toxin p-Cresylsulfate: An In Vitro Study.
Tsai, I., Hsu, C., Hung, W., Wang, C.-P., Yu, T., Houng, J., Lee, K., & Tang, W.-H. (2019) · Europe PMC (PubMed Central) · doi:10.6515/acs.201911_35(6).20190423c · Cited by 4
Personalization of Mathematical Models of Human Atrial Action Potential
Pikunov, A. V., Syunyaev, R. A., Steckmeister, V., Kutschka, I., Voigt, N., & Efimov, I. R. (2021) · Smart innovation, systems and technologies · doi:10.1007/978-981-33-4709-0_19 · Cited by 4
Controllability of voltage- and calcium-driven cardiac alternans in a map model
Muñoz, L. M., Ampofo, M. O., & Cherry, E. M. (2021) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/5.0040064 · Cited by 4
Baltov, B., Beyl, S., Baburin, I., Reinhardt, J. K., Szkokan, P., Garifulina, A. I., Timin, E., Kraushaar, U., Potterat, O., Hamburger, M. O., et al. (2023) · Toxicology Reports · doi:10.1016/j.toxrep.2023.04.014 · Cited by 4
“Simulated AP of the human ventricular cardiomyocyte at steady state with pacing at 1 Hz according to the O’Hara-Rudy model [21].”
MethodInfluentialPredicting hERG repolarization power at 37°C from recordings at room temperature
Oliveira-Mendes, B. B. R., Alameh, M., Montnach, J., Ollivier, B., Gibaud, S., Feliciangeli, S. F., Lesage, F., Charpentier, F., Loussouarn, G., WAARD, M. M. D., et al. (2023) · Clinical and Translational Medicine · doi:10.1002/ctm2.1266 · Cited by 5
Yoon, S., Lee, H.-L., Jeong, D. U., Lim, K. M., Park, S.-J., & Kim, K. (2023) · Frontiers in Pharmacology · doi:10.3389/fphar.2023.1220796 · Cited by 4
A Concept for Myocardial Current Density Estimation with Magnetoelectric Sensors
Engelhardt, E., Elzenheimer, E., Hoffman, J., Schmidt, T., Zaman, A., Frey, N., & Schmidt, G. U. (2023) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2023-1023 · Cited by 4
“As control function 𝑢 , we use the scaled and low-pass filtered absolute derivative of the action potential of a healthy ventricular cell calculated with Myokit [6] using the dynamic O’Hara-Rudy model [8] (cf. Fig.”
Wang, R., Qu, Z., & Huang, X. (2024) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1011930 · Cited by 4
Mateias, A. L., Armăşescu, F., Amuzescu, B. P., Corlan, A. D., & Radu, B. M. (2024) · Biomolecules · doi:10.3390/biom14121582 · Cited by 4
Metadata
- Authors
- O'Hara, T., Virág, L., Varró, A., & Rudy, Y.
- Affiliations
- University of Szeged (HU)
- Washington University in St. Louis (US)
- Corresponding author
- Rudy, Yoram
- Venue
- PLoS Computational Biology
- Publisher
- Public Library of Science (PLoS)
- Published
- 2011-05-26
- Volume
- 7
- Issue
- 5
- Pages
- e1002061
- ISSN
- 1553-734X (ISSN-L)
- 1553-7358
- PMC
- PMC3102752
- OpenAlex
- W2115765852
- Cited by
- 1,196
- References
- 110
- Citations by year
- 2026: 50 · 2025: 61 · 2024: 89 · 2023: 102 · 2022: 95 · 2021: 97 · 2020: 118 · 2019: 98 · 2018: 89 · 2017: 100 · 2016: 83 · 2015: 67 · 2014: 63 · 2013: 47 · 2012: 27
- FWCI
- 31.78
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- PLoS Computational Biology (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- SZTE Publicatio Repozitórium (University of Szeged) (acceptedVersion, other-oa)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Science Foundation (0929633)
- American Heart Association
- Fondation Leducq
- Hungarian Scientific Research Fund (OTKA CNK-77855)
- Nemzeti Kutatási és Technológiai Hivatal
- National Institutes of Health
- U.S. Public Health Service (R01-HLR01033343-26)
- National Heart, Lung, and Blood Institute (R01HL049054, R01HL-049054-18, R56HL049054)
- Division of Chemical, Bioengineering, Environmental, and Transport Systems
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion channel regulation and function
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- cardiac electrophysiology models, L-type calcium current, transient outward potassium current, Na+/Ca2+ exchanger, inward rectifier potassium current, action potential duration restitution, rate dependence, early afterdepolarizations, calcium alternans, calcium/calmodulin-dependent protein kinase, SERCA, intracellular sodium, late sodium current, transmural heterogeneity, human ventricular myocytes
- MeSH terms
- Action Potentials, Arrhythmias, Cardiac, Calmodulin, Heart Ventricles, Humans, Models, Cardiovascular, Reproducibility of Results, Sodium Channels, Ventricular Function, Patch-Clamp Techniques, Computational Biology, Calcium Channels, L-Type, Myocytes, Cardiac
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.