Simulation of the Undiseased Human Cardiac Ventricular Action Potential: Model Formulation and Experimental Validation
Open accessThe DOI matches its Crossref record; 110 of the 110 references it cites were found in a registry or an index.
Abstract
Cellular electrophysiology experiments, important for understanding cardiac arrhythmia mechanisms, are usually performed with channels expressed in non myocytes, or with non-human myocytes. Differences between cell types and species affect results. Thus, an accurate model for the undiseased human ventricular action potential (AP) which reproduces a broad range of physiological behaviors is needed. Such a model requires extensive experimental data, but essential elements have been unavailable. Here, we develop a human ventricular AP model using new undiseased human ventricular data: Ca(2+) versus voltage dependent inactivation of L-type Ca(2+) current (I(CaL)); kinetics for the transient outward, rapid delayed rectifier (I(Kr)), Na(+)/Ca(2+) exchange (I(NaCa)), and inward rectifier currents; AP recordings at all physiological cycle lengths; and rate dependence and restitution of AP duration (APD) with and without a variety of specific channel blockers. Simulated APs reproduced the experimental AP morphology, APD rate dependence, and restitution. Using undiseased human mRNA and protein data, models for different transmural cell types were developed. Experiments for rate dependence of Ca(2+) (including peak and decay) and intracellular sodium ([Na(+)](i)) in undiseased human myocytes were quantitatively reproduced by the model. Early afterdepolarizations were induced by I(Kr) block during slow pacing, and AP and Ca(2+) alternans appeared at rates >200 bpm, as observed in the nonfailing human ventricle. Ca(2+)/calmodulin-dependent protein kinase II (CaMK) modulated rate dependence of Ca(2+) cycling. I(NaCa) linked Ca(2+) alternation to AP alternans. CaMK suppression or SERCA upregulation eliminated alternans. Steady state APD rate dependence was caused primarily by changes in [Na(+)](i), via its modulation of the electrogenic Na(+)/K(+) ATPase current. At fast pacing rates, late Na(+) current and I(CaL) were also contributors. APD shortening during restitution was primarily dependent on reduced late Na(+) and I(CaL) currents due to inactivation at short diastolic intervals, with additional contribution from elevated I(Kr) due to incomplete deactivation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 1 Undiseased human ICaL experiments and model validation. A) Experiments: ICaL traces for currents carried by Ca2+ (top), Ba2+ (middle), and Sr2+ (bottom). The voltage protocol is below the Ca2+ traces. Ca2+ current decay was visibly more rapid than decay for Ba2+ or Sr2+ currents. Simulations: ICaL in response to the same voltage protocol with CDI (CDI+VDI, top), and without CDI (VDI-only, bottom). B) Experimental data are on the left (white circles, N = 5, from 3 hearts). Simulation results are on the right (solid lines). FRC is fractional remaining current. Times after peak current shown are from 5 to 55 ms, in 5 ms steps (indicated by arrow). Top left) Experiments showing the voltage and time dependence of FRC with Ba2+ as charge carrier (VDI only). Top right) Simulations of FRC, with n−gate = 0 (representing VDI only; see text and panel E). Bottom left) Experiments showing FRC with Ca2+ as charge carrier (CDI and VDI are concurrent). FRC for CDI+VDI was significantly smaller at more hyperpolarized potentials (Vm = −20 to 0 mV, dashed box) than FRC for VDI-alone. Bottom right) Simulations of FRC with free running n gate, allowing both CDI and VDI to occur. C) Data are from Magyar et al.[11] (black squares), Fulop et al.[12] (black diamonds), and previously unpublished (white circles, N = 5, from 3 hearts). Simulation results are solid lines. From left to right, top to bottom: steady state activation, steady state inactivation, fast time constant for VDI, slow time constant for VDI, relative weight of the fast component for VDI, I–V curve, experiments showing recovery from inactivation, and corresponding simulations. D) Human AP clamp waveform, used to elicit 1 µM nisoldipine sensitive current (ICaL, experiments, left) and comparison to simulations using the same AP clamp (right). E) Schematic diagram for the n gate, representing the fraction of L-type channels undergoing CDI. Calmodulin (CaM) is constitutively attached to the L-type channel. Ca2+ ions bind to CaM (on-rate k1 and off-rate k-1). With Ca2+ ions bound, the Ca2+/CaM/channel complex may activate CDI mode (asterisk and black color indicate CDI activation, on-rate k2 and off-rate k-2).](https://figures.cochat.ai/paper-figures/77154b4d77164fafa05b6b606a19318d/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-1.jpg)
![Figure 2 Undiseased human Ito, INaCa, and IK1 experiments and model validation. A) Ito. Experimental data are white circles (N = 8 from 5 hearts for inactivation time constants, N = 10 from 5 hearts for recovery time constants, N = 9 from 6 hearts for steady state inactivation, and N = 23 from 8 hearts for the I–V curve). Simulation results are solid lines. From left to right, top to bottom: steady state activation, steady state inactivation, fast time constant for inactivation, slow time constant for inactivation (insets show fast and slow recovery from inactivation), relative weight of the fast component for inactivation and the I–V curve (normalized). B) INaCa. Experimental data are digitally averaged time traces (N = 3 from 2 hearts, white circles, gray is standard error of the mean). Simulation results are the solid line. Top) Voltage clamp protocol. Bottom) INaCa in response to the clamp. C) IK1. Experimental data are previously unpublished (white circles, N = 21 from 12 hearts), from Bailly et al.[37] (black squares) and Konarzewska et al.[38](black triangles). Simulation results are solid lines (black, gray and dashed black for [K+]o = 4, 8 and 20 mM). Top left) Voltage and [K+]o dependence of steady state rectification. Top right) Voltage and [K+]o dependence of steady state inactivation. Bottom left) Time constant for inactivation. Bottom right) I–V curve, and its [K+]o dependence.](https://figures.cochat.ai/paper-figures/0607c8584c2240a5b55c36291194fb4c/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-2.jpg)
![Figure 3 Undiseased human IKr and IKs experiments and model validation. A) IKr. Experimental data are white circles (N = 10 from 7 hearts for steady state activation, N = 7 from 3 hearts for activation and from 2 hearts for deactivation time constants and weights, and N = 10 from 7 hearts for tail currents). Simulation results are lines. From left to right, top to bottom: steady state activation, time constant for activation (fast (solid) and slow (dashed) time constants converge), fast time constant for deactivation, slow time constant for deactivation, relative weight of the fast component for deactivation, and the I–V curve for normalized tail currents. B) Activation/deactivation profiles in response to the voltage steps shown (−40 mV holding potential to +30 mV steps of various duration, followed by a return to −40 mV, top right inset). Experiments are above. Simulations are below. Activation is rapid, occurring within tens of milliseconds. Deactivation is slow, occurring after several seconds. C) Human AP clamp waveform (top), used to elicit 1 µM E-4031 sensitive current (IKr, bottom); experiments are on the left, and comparison to simulations using the same AP clamp is on the right. D) IKs. Data are from Virág et al.[41] (black circles). Simulation results are solid lines. From left to right: steady state activation, time constant for activation (much slower than deactivation at depolarized potentials), time constant for deactivation (much faster than activation at hyperpolarized potentials), and the I–V curve, showing normalized tail currents.](https://figures.cochat.ai/paper-figures/e000cfe343c1469d9064b4a0eeb86bd0/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-3.jpg)
![Figure 4 Nonfailing human fast INa and late INa experiments and model validation. A) Fast INa. Experiments are from Sakakibara et al.[44] (black squares) and Nagatomo et al.[45] (black triangles). Simulation results are solid lines. From left to right, top to bottom: steady state activation, time to peak (experiment) and activation time constant (simulation), steady state inactivation, fast time constant for development of inactivation, slow time constant for development of inactivation, time constant for recovery from inactivation, and the I–V curve (solid line simulation and data at 17°C, dashed line simulation at 37°C). In other panels, simulations and data were adjusted to 37°C. Time to peak was fit at 33°C. B) Late INa. Experiments are from Maltsev et al.[51] (black squares). Simulation results are solid lines. Top) Steady state activation. Middle) Steady state inactivation. Bottom) I–V curve.](https://figures.cochat.ai/paper-figures/1bc72be1ff78416eb0539041b17ce71d/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-4.jpg)


![Figure 7 Undiseased human endocardial AP response to pacing protocols from experiments (small tissue preparations) and model simulations. A) Steady state APD rate dependence. B) S1S2 APD restitution (DI – diastolic interval). APD30–90 are labeled at right. Solid lines are simulation results; white squares are experiments at 37°C (N = 140 hearts in panel A, N = 50 hearts in panel B). C) Repolarization rate at CL = 1000 ms. Trajectory of APD30 to APD90 is accurate in the ORd model (white squares are experimental data); less so in other models. D) Dynamic restitution protocol (see Methods). Experiments are from Koller et al.[58], measured in nonfailing human hearts with monophasic AP electrodes (black squares). Simulated results are the black line. At very short diastolic intervals (DI<90 ms), the model shows APD bifurcation (alternans).](https://figures.cochat.ai/paper-figures/5bf8b14e1f23445fbe171a340c65ec27/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-7.jpg)


![Figure 10 Transmural heterogeneity and validation of transmural cell type models. A–C) Expression ratio in the model (black bars) compared to experimental data from undiseased human hearts (grayscale bars, labeled). D) Transmural heterogeneity of Ito; simulations are lines, experiments are squares. Results for endo are gray; those for epi are black. E1) Rate dependence of APD90 in endo, M, and epi cell types. Epi and M data were obtained by scaling endo data (white squares) by epi/endo and M/endo APD90 ratios from Drouin et al.[50] (black squares). Simulations are black lines. E2) Same format as panel E1, showing epi APD90 at faster pacing rates. Data are from Glukhov et al.[71], (epi/endo scaling, black triangles). F) Top to bottom: Rate-dependence of endo, M, and epi APs. G) Pseudo-ECG, using a simulated transmural wedge. CL changes are indicated by arrows.](https://figures.cochat.ai/paper-figures/1858cf93ccb24d138364411aa9171594/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-10.jpg)
![Figure 11 Early afterdepolarizations (EADs). A) Top left) Experiments in isolated nonfailing human endo myocytes from Guo et al.[73] showed EADs with slow pacing (CL = 4000 ms) in the presence of IKr block (0.1 µM dofetilide, ∼85% IKr block[74], reproduce with permission). Top right) Following the experimental protocol of Guo et al. (CL = 4000 ms, 85% IKr block) the ORd model accurately showed a single large EAD. Bottom) GB (left) and TP (right) models failed to generate EADs (CL = 4000 ms, even with 100% IKr block). B) EAD mechanism. APs are on top. ICaL (black) and ICaL recovery gate (gray) are below. Slow pacing alone (CL = 4000 ms) did not cause an EAD (left). Slow pacing plus IKr block (85%) caused an EAD (solid lines, right). The EAD was depolarized by ICaL reactivation during the slowly repolarizing AP plateau (solid lines, solid arrows). When ICaL recovery was prevented, the EAD was eliminated (dashed lines and dashed arrow).](https://figures.cochat.ai/paper-figures/f149e810e43a4018aa88d922b48d5501/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-11.jpg)
![Figure 12 Rate dependence of intracellular ion concentrations. Simulation results are solid lines. A) [Na+]i versus pacing frequency (normalized to 0.25 Hz). Experiments are from nonfailing myocytes (Pieske et al.[57], black squares). B) Peak Ca2+ transient (normalized to 0.5 Hz). Experiments are from nonfailing myocytes (Schmidt et al.[76], black squares). C) Ca2+ transients from experiments (Fura-2-AM) and simulations. Results are normalized to illustrate the time course of decay. The arrow indicates pacing CL changes. D) Frequency dependent acceleration of relaxation. Undiseased human experimental data are white circles. Simulations are the black line.](https://figures.cochat.ai/paper-figures/ef54eb92e96d49ff88664d97c8a51055/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-12.jpg)
![Figure 13 CaMK and Ca2+ cycling. A) Rate dependence of CaMK active fraction. B) Ca2+ cycling under control conditions (left) and without CaMK (right). CL changes are indicated by arrows. Top) [Ca2+]i and diastolic values (inset). Middle) [Ca2+]JSR. Bottom) Jup and Jrel (inset, expanded time scale).](https://figures.cochat.ai/paper-figures/e1891823cb1c44268191312b4fe6d66e/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-13.jpg)
![Figure 14 AP and Ca2+ alternans at fast pacing. Black lines are control. Gray lines are without CaMK. The two consecutive beats are labeled 1 and 2. A) Pacing at CL = 250 ms. From left to right, top to bottom: AP, expanded time scale showing AP repolarization, Jrel (inset is expanded time scale), [Ca2+]i, [Ca2+]JSR, and Jup. B) Rate dependence of APD (top) and peak [Ca2+]i (bottom) at fast rates (alternans bifurcations disappear without CaMK). C) Same as panel B, but at slower rates (no bifurcations).](https://figures.cochat.ai/paper-figures/eac046432d3a40d7b4647ffa370f37f5/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-14.jpg)

![Figure 16 Major causes of steady state APD rate dependence and S1S2 APD restitution. A) APD rate dependence in control (solid black), and with [Na+]i and [Na+]ss clamped to slow rate (solid gray) or fast rate (dashed black) values. When late INa (dashed gray) or both late INa and ICaL inactivation gates were reset to their slow rate values (dash-dot-dot gray) in addition to [Na+]i and [Na+]ss slow rate clamp, APD lost almost all rate dependence. Note that slow rate [Na+]i and [Na+]ss clamp alone left residual APD rate dependence, especially at fast rates (CL = 300 to 700 ms, shaded box). B) APD rate dependence (control, solid black) was largely unaffected by resetting inactivation gates for late INa (dashed gray), ICaL (dash-dot-dot gray), or late INa and ICaL (solid gray) to their slow rate values (no [Na+]i and [Na+]ss clamping to slow rate values). C) [Na+]i and INaK increase with pacing rate under control conditions (left). When [Na+]i and [Na+]ss are clamped to slow rate values, INaK is small and rate independent (right). D) APD restitution in control (solid black), and when inactivation gates were reset to S1 values upon S2 delivery (late INa reset – dashed gray, ICaL reset – dash-dot-dot gray, late INa and ICaL reset – solid gray). Shown in dashed black is resetting late INa and ICaL inactivation to the DI = 5 ms value. E) [Na+]i and [Na+]ss clamp to S1 values (dashed gray) did not affect APD restitution (control, solid black).](https://figures.cochat.ai/paper-figures/48cb13a7d63148b88e1f1a1a957108d3/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-16.jpg)

![Figure 18 Comparison with other human ventricular AP models. Single endo cell simulations from ORd, TP, and GB models are solid black, gray, and dashed black lines, respectively. Experimental results (small tissue preparations) are white squares. A) APD rate dependence. Results for APD90, 70, 50 and 30 are shown top left, top right, bottom left, and bottom right, respectively. B) The AP, major currents, [Na+]i, and [Ca2+]i at steady state for CL = 1000 ms. From left to right, top to bottom: AP (with Vm rest inset at far right), INa (inset shows peaks), late INa (not present in TP or GB models), Ito (inset shows decay rate), ICaL (arrow shows ORd peak magnitude; inset shows normalized peaks, which are wide in TP and GB), IKr (arrow shows ORd early spike peak magnitude), IKs, IK1, INaCa, INaK, [Ca2+]i, [Ca2+]i decay rate, and [Na+]i.](https://figures.cochat.ai/paper-figures/ed5768b836094b8fa6a37c72910bad90/simulation-of-the-undiseased-human-cardiac-ventricular-action-potential-model-figure-18.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“For subject-specific virtual patients, it may be possible to collect pre- and post-intervention data from the same subject, enabling validation of both the virtual patient in isolation and the coupled device-patient model (Fig 2d; see [56] for an example in stent-graft deployment)”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [56]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Calmodulin kinase determines calcium-dependent facilitation of L-type calcium channels
Dzhura, I., Wu, Y., Colbran, R. J., Balser, J. R., & Anderson, M. E. (2000) · Nature Cell Biology · doi:10.1038/35004052 · Cited by 335 · cited 1×
“dog ICaL model[19] and as measured experimentally[21].”
RetractedCoassembly of KVLQT1 and minK (IsK) proteins to form cardiac IKS potassium channel
Sanguinetti, M. C., Curran, M. E., Zou, A., Shen, J., Specter, P. S., Atkinson, D. L., & Keating, M. T. (1996) · Nature · doi:10.1038/384080a0 · Cited by 1,764 · cited 1×
“. The presence of KCNE1 carries two important functional consequences 1) ∼5 fold slower activation and 2) ∼5 fold larger conductance”
Luo, C. H., & Rudy, Y. (1994) · Circulation Research · doi:10.1161/01.res.74.6.1071 · Cited by 1,589 · cited 1×
“guinea pig predecessor[80].”
Self-citationLuo, C. H., & Rudy, Y. (1991) · Circulation Research · doi:10.1161/01.res.68.6.1501 · Cited by 1,468 · cited 12×
“ON NA+ HANDLING, INAK AND APD RATE DEPENDENCE .......................................................... 32 EFFECT OF KCNE1 HETEROGENEITY ON TRANSMURAL IKS AND AP SIMULATIONS ..................................................................... 33 APD ACCOMMODATION .....................................................…”
BackgroundInfluentialSelf-citationSanguinetti, M. C., & Jurkiewicz, N. K. (1990) · The Journal of general physiology · doi:10.1085/jgp.96.1.195 · Cited by 1,457
A model for human ventricular tissue
ten Tusscher, K. H. W. J., Noble, D., Noble, P. J., & Panfilov, A. V. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00794.2003 · Cited by 1,416 · cited 1×
“The TP model[81] and updated”
Alternans and spiral breakup in a human ventricular tissue model
ten Tusscher, K. H. W. J., & Panfilov, A. V. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00109.2006 · Cited by 1,122 · cited 5×
“Rate dependence in the TP model[9] is less [Na]i dependent because, as Grandi discussed[10], IKs is exaggerated.”
InfluentialCalmodulin Is the Ca2+ Sensor for Ca2+-Dependent Inactivation of L-Type Calcium Channels
Peterson, B. Z., DeMaria, C. D., & Yue, D. T. (1999) · Neuron · doi:10.1016/s0896-6273(00)80709-6 · Cited by 856
Cellular Basis for the Electrocardiographic J Wave
Yan, G.-X., & Antzelevitch, C. (1996) · Circulation · doi:10.1161/01.cir.93.2.372 · Cited by 812
Wehrens, X. H. T., Lehnart, S. E., Reiken, S. R., & Marks, A. R. (2004) · Circulation Research · doi:10.1161/01.res.0000125626.33738.e2 · Cited by 623 · cited 1×
“Wehrens et al.[96] with KN-93 in rabbit) should be performed in human ventricular myocytes to validate model predictions.”
Method
Cited by
Items 601–700 of 1,000
Qauli, A. I., Nurul Qashri Mahardika, T., Hanum, U. L., Vanheusden, F. J., & Lim, K. M. (2025) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2025.108609 · Cited by 10
Safety pharmacology in 2014: New focus on non-cardiac methods and models
Pugsley, M. K., Dalton, J. A., Authier, S., & Curtis, M. J. (2014) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2014.08.004 · Cited by 10
van Duijvenboden, S., Porter, B., Pueyo, E., Sampedro-Puente, D. A., Fernández-Bes, J., Sidhu, B. S., Gould, J., Orini, M., Bishop, M. J., Hanson, B. M., et al. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2019.01582 · Cited by 10
“In this study, a set of stochastic human ventricular action potential models was developed by individually varying the ionic conductances of IKr, ICaL, and IK1 from their nominal values in the O’HaraVirág-Varró-Rudy (ORd) action potential model (O’Hara et al., 2011).”
MethodHancox, J. C., Stuart, G., & Harmer, S. C. (2020) · Journal of Congenital Cardiology · doi:10.1186/s40949-020-00037-9 · Cited by 10
Mechanisms of flecainide induced negative inotropy: An in silico study
Yang, P., Giles, W. R., Belardinelli, L., & Clancy, C. E. (2021) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2021.05.007 · Cited by 10
“We utilized the computational models based on the Grandi-Bers formulations for atrial [24] and ventricular [21] myocyte action potential and [Ca2+] homeostasis as well as the O’HaraRudy ventricular human model [25].”
MethodKabakov, A. Y., Sengun, E., Lu, Y., Roder, K., Bronk, P., Baggett, B., Turan, N. N., Moshal, K. S., & Koren, G. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.672360 · Cited by 10
Jiang, H., Zhang, S., Bi, X., Ma, W., & Wei, Z. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.105066 · Cited by 10
Kaboudian, A., Cherry, E. M., & Fenton, F. H. (2021) · Computing in cardiology · doi:10.23919/cinc53138.2021.9662759 · Cited by 10
“1E-F use the OVVR model [13] with doubled capacitance g Ito and the time constant τ d multiplied by five, resulting in meandering dynamics and EADs emanating from the wave back.”
MethodInfluentialBukhari, S. H. A., Palmieri, F., Ferreira, D., Potse, M., Ramírez, J., Laguna, P., Sánchez, C., & Pueyo, E. (2019) · Computing in cardiology · doi:10.22489/cinc.2019.404 · Cited by 10
Zhang, S., Lu, W., Yang, F., Li, Z., Wang, S., Jiang, M., Wang, X., & Wei, Z. (2022) · npj Systems Biology and Applications · doi:10.1038/s41540-022-00254-5 · Cited by 10
“The ratio of ENDO:MCELL:EPI was set to 37:26:37 as in previous study 14 .”
Modeling Calcium Cycling in the Heart: Progress, Pitfalls, and Challenges
Qu, Z., Yan, D., & Song, Z. (2022) · Biomolecules · doi:10.3390/biom12111686 · Cited by 10
Efficient time splitting schemes for the monodomain equation in cardiac electrophysiology
Lindner, L. P., Gerach, T., Jahnke, T., Loewe, A., Weiss, D. L., & Wieners, C. (2023) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3666 · Cited by 10
“The advantages of SI-SVI or LI-SVI will likely transfer to more complex cell models, as the model by ten Tusscher and Panfilov, 47 O'Hara and Rudy 48 or Courtemanche.”
The role of β-adrenergic stimulation in QT interval adaptation to heart rate during stress test
Pérez, C., Cebollada, R., Mountris, K. A., Martínez, J. P., Laguna, P., & Pueyo, E. (2023) · PLoS ONE · doi:10.1371/journal.pone.0280901 · Cited by 10
Carbon monoxide effects on human ventricle action potential assessed by mathematical simulations
Trénor, B., Cardona, K., Sáiz, J., Rajamani, S., Belardinelli, L., & Giles, W. R. (2013) · Frontiers in Physiology · doi:10.3389/fphys.2013.00282 · Cited by 10
“Early in this study, some simulations were carried out using the latest human ventricular AP model published by O’Hara et al. (2011).”
MethodOn complex dynamics in a Purkinje and a ventricular cardiac cell model
Erhardt, A. H., & Solem, S. (2020) · Communications in Nonlinear Science and Numerical Simulation · doi:10.1016/j.cnsns.2020.105511 · Cited by 10
“Indeed, more complex calcium dynamics is expected for more up-to-date models, such as the ones in [27,54,56] .”
Parameter variations in personalized electrophysiological models of human heart ventricles
Ushenin, K. S., Kalinin, V., Gitinova, S., Sopov, O., & Solovyova, O. E. (2021) · PLoS ONE · doi:10.1371/journal.pone.0249062 · Cited by 10
Cardiovascular Drugs: an Insight of In Silico Drug Design Tools
Sarma, H., Upadhyaya, M., Gogoi, B., Phukan, M., Kashyap, P., Das, B., Devi, R., & Sharma, H. K. (2021) · Journal of Pharmaceutical Innovation · doi:10.1007/s12247-021-09587-w · Cited by 10
The Inverse Problem of Electrocardiology
Franzone, P. C., Pavarino, L. F., & Scacchi, S. (2014) · Modeling, simulation & applications · doi:10.1007/978-3-319-04801-7_6 · Cited by 10
Jæger, K. H., & Tveito, A. (2025) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1013149 · Cited by 9
T-World Virtual Human Cardiomyocyte. I. Development, Validation, and Cell Arrhythmogenesis
Tomek, J., Holmes, M., Bury, T. M., Tomková, M., Jo, H., Nagy, N., Bertrand, A., Bueno‐Orovio, A., Colman, M. A., Rodríguez, B., et al. (2026) · Circulation Research · doi:10.1161/circresaha.125.328073 · Cited by 9
“T-World replicates EADs under realistic conditions of drug-induced long QT (Figure 4B), similar to ToR-ORd and ORd models, 4,18 with a 13-mV amplitude, similar to experimental observations.”
InfluentialComputational Cardiac Safety Testing
Mirams, G. R. (2023) · Springer eBooks · doi:10.1007/978-3-030-73317-9_137-1 · Cited by 9
Grandits, T., Augustin, C. M., Haase, G., Jost, N., Mirams, G. R., Niederer, S., Plank, G., Varró, A., Virág, L., & Jung, A. (2023) · eLife · doi:10.7554/elife.91911.3 · Cited by 9
Self-citationEngelhardt, E., Elzenheimer, E., Hoffmann, J., Meledeth, C., Frey, N., & Schmidt, G. U. (2023) · Bioengineering · doi:10.3390/bioengineering10121432 · Cited by 9
“We use Myokit [20] to calculate an action potential based on the dynamic O’Hara-Rudy model [21].”
MethodWülfers, E. M., Moss, R., Lehrmann, H., Arentz, T., Westermann, D., Seemann, G., Odening, K. E., & Steinfurt, J. (2024) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2024.101373 · Cited by 9
“Cellular electrophysiology was computed using the O ’ Har-a – Vir ´ ag – Varr ´ o – Rudy model of human ventricular myocytes [33].”
MethodNurul Qashri Mahardika, T., Qauli, A. I., Marcellinus, A., & Lim, K. M. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1374355 · Cited by 9
“The development of the O ’ Hara Rudy (ORd) ventricular cell model was observed in disease-free human ventricular cells from a wealth of experimental data obtained from healthy individuals (O ’ Hara et al., 2011).”
MethodKaboudian, A., Gray, R. A., Uzelac, I., Cherry, E. M., & Fenton, F. H. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108456 · Cited by 9
Iwata, H., & Saito, R. (2024) · CPT Pharmacometrics & Systems Pharmacology · doi:10.1002/psp4.13288 · Cited by 9
Sex-specific human electromechanical multiscale in-silico models for virtual therapy evaluation
Holmes, M., Wang, Z. J., Doste, R., Camps, J., Martinez‐Navarro, H., Smith, H. J., Tomek, J., & Rodríguez, B. (2025) · Journal of Molecular and Cellular Cardiology Plus · doi:10.1016/j.jmccpl.2025.100479 · Cited by 9
“The single-cell simulations replicated the action potential duration (APD) prolongation induced by Ranolazine and Dofetilide observed in human ventricular myocytes [46] and canine ventricular wedge preparations [39] (Fig.”
InfluentialWei, H., Wu, J., & Liu, Z. (2017) · Methods in molecular biology · doi:10.1007/978-1-4939-7362-0_2 · Cited by 9
Yuniarti, A. R., Setianto, F., Marcellinus, A., Hwang, H. J., Choi, S. W., Trayanova, N. A., & Lim, K. M. (2018) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2970 · Cited by 9
“To confirm the electrophysiology properties in our study, we compared the shape of AP in single cell from our simulation with the previous studies.(1,7) For the WT condition, we compared the AP shape of endo, M, and epi cells with the model proposed by O'Hara et al,(1) which is based on experimental study from Gluckho…”
MethodResultCarro, J., Pueyo, E., & Matas, J. F. R. (2018) · PLoS ONE · doi:10.1371/journal.pone.0204411 · Cited by 9
Costabal, F. S., Jiang, Y. D., Sher, A., & Ellen Kuhl, A. (2018) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2018.10.003 · Cited by 9
Zhang, H., Zhang, S., Wang, W. J., Wang, K., & Shen, W. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00972 · Cited by 9
Hichri, E., Selimi, Z., & Kučera, J. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.589386 · Cited by 9
He, J., Pertsov, A. M., Cherry, E. M., Fenton, F. H., Roney, C. H., Niederer, S., Zang, Z., & Mangharam, R. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3223063 · Cited by 9
“OVER the past two decades, there has been steady progress towards the development of realistic electrophysiological models [1], [2], [3] of cardiac propagation with detailed”
BackgroundUncertainty assessment of proarrhythmia predictions derived from multi-level in silico models
Kopańska, K., Rodríguez-Belenguer, P., Llopis‐Lorente, J., Trénor, B., Sáiz, J., & Pastor, M. (2023) · Archives of Toxicology · doi:10.1007/s00204-023-03557-6 · Cited by 9
“(2011) (O’Hara et al. 2011) was used as the baseline model.”
MethodDubois, V. F. S., Casarotto, E., Danhof, M., & Pasqua, O. E. D. (2016) · British Journal of Pharmacology · doi:10.1111/bph.13558 · Cited by 9
“The authors propose a computational system including simulations for the evaluation of proarrthymic potential (Tusscher et al., 2004; O’Hara et al., 2011), taking into account the influence of inter-individual variability in the parameters of interest.”
An overview of the safety pharmacology society strategic plan
Pugsley, M. K., Authier, S., Koerner, J. E., Redfern, W. S., Markgraf, C. G., Brabham, T., Correll, K. G., Soloviev, M. V., Botchway, A., Engwall, M. J., et al. (2018) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2018.01.001 · Cited by 9
Christophe, B., & Crumb, W. (2018) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2018.12.004 · Cited by 9
Cansız, B., Woodworth, L. A., & Kaliske, M. (2021) · Mechanics Of Soft Materials · doi:10.1007/s42558-021-00033-y · Cited by 9
“In a recent in silico study which used the O’Hara-Rudy action potential model [40], Costabal et al.”
MethodSimulating the effects of serum potassium on the ECG
Kharche, S., Callisesi, G., Starý, T., Bracci, A., & Severi, S. (2012) · Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) · Cited by 9
Morissette, P., Polak, S., Chain, A. S. Y., Zhai, J., Imredy, J. P., Wildey, M. J., Travis, J. J., Fitzgerald, K. P., Fanelli, P. A., Passini, E., et al. (2020) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2020.114883 · Cited by 9
Qu, Y., Gao, B., Arimura, Z., Fang, M., & Vargas, H. M. (2021) · Clinical and Translational Science · doi:10.1111/cts.13039 · Cited by 9
Self-preservation ability and residential fire emergencies.
MacEachron, A. E., & Janicki, M. P. (1983) · PubMed · Cited by 9
Abrasheva, V. O., Sandaara, K., Slotvitsky, М. М., Scherbina, S., Aitova, A. A., Frolova, S. R., Tsvelaya, V. A., & Syunyaev, R. A. (2024) · The Journal of Physiology · doi:10.1113/jp285162 · Cited by 8
“…of I Na and I K1 conductivities (to 40 mS/ μ F and 0.76 mS/ μ F, respectively) abolished the oscillations, restored the resting potential of − 87 mV and resulted in a d V /d t max value of 250 V/s, typical of ventricular tissue (Drouin et al., 1995; Lemoine et al., 2017; O’Hara et al., 2011).”
BackgroundMethodInfluentialLu, H. R., Damiano, B. P., Kreir, M., Rohrbacher, J., van der Linde, H. J., Saidov, T. A., Teisman, A. C. H., & Gallacher, D. J. (2023) · Biomolecules · doi:10.3390/biom13091355 · Cited by 8
“Our studies and overall analysis of in vitro and in vivo nonclinical findings for lop-eramide fully support the high safety margins of loperamide and its well-established clinical safety profile, when used within its recommended therapeutic dose range for the treatment of acute diarrhea.”
Zhang, Y., Zhang, Z., & Qu, Z. (2024) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00004.2024 · Cited by 8
Role of ryanodine receptor cooperativity in Ca2+‐wave‐mediated triggered activity in cardiomyocytes
Zhong, M., & Karma, A. (2024) · The Journal of Physiology · doi:10.1113/jp286145 · Cited by 8
“Therefore, it might be possible to replicate these phenomena using the widely used common pool model, a computationally cost-effective framework that treats the entire cytosol space as a single compartment (Luo & Rudy, 1994; Mahajan et al., 2008; O’Hara et al., 2011; Shiferaw et al., 2003).”
Learning high-dimensional ionic model dynamics using Fourier Neural Operators
Pellegrini, L., Ghiotto, M., Centofanti, E., & Pavarino, L. F. (2025) · Machine learning for computational science and engineering · doi:10.1007/s44379-025-00046-8 · Cited by 8
“Finally, we discuss the three specific ionic models considered in this study: the FitzHugh-Nagumo [9], Hodgkin-Huxley [13], and O’Hara-Rudy [24] models.”
InfluentialVandersickel, N., Kazbanov, I. V., Defauw, A., Pijnappels, D. A., & Panfilov, A. V. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.01.033 · Cited by 8
“It would be interesting to study this effect in other models.(48,49) This study investigated defibrillation in anisotropic cardiac tissue with parallel fibers; studies for more complex fiber orientations were not performed.”
BackgroundCardiac computational modelling
Bragard, J. R., Cámara, Ó., Echebarria, B., Gerardo‐Giorda, L., Pueyo, E., Sáiz, J., Sebastián, R., Soudah, E., & Vázquez, M. (2020) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2020.05.024 · Cited by 8
“For instance, in cardiac electrophysiology, experimental and clinical data are integrated by improved computational models of human action potential 2 and its propagation in 2-dimensional (2D) and 3-dimensional (3D) cardiac structures.”
BackgroundClark, A. P., Clerx, M., Wei, S., Lei, C. L., de Boer, T. P., Mirams, G. R., Christini, D. J., & Krogh‐Madsen, T. (2023) · EP Europace · doi:10.1093/europace/euad243 · Cited by 8
“Non-firing cells (MP = − 42 ± 8 mV) and cells with spontaneously firing APs were depolarized (MP = − 54 ± 7 mV)—the spontaneously firing cells also had a shorter AP duration ( APD 90 = 128 ± 71 ms) ( Figure 7B ) relative to adult cardiomyocytes 28 and iPSC-CM models.”
ResultNeeds, D., Wu, T., Nguyen, H. X., Henriquez, C. S., & Bursac, N. (2023) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00287.2023 · Cited by 8
Fibrosis modeling choice affects morphology of ventricular arrhythmia in non-ischemic cardiomyopathy
Myklebust, L., Maleckar, M. M., & Arevalo, H. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1370795 · Cited by 8
A new myofilament contraction model with ATP consumption for ventricular cell model
Muangkram, Y., Noma, A., & Amano, A. (2017) · The Journal of Physiological Sciences · doi:10.1007/s12576-017-0560-x · Cited by 8
“of the human ventricular models [42, 43], including the HuVEC model, failed to evoke the appropriate magnitudes”
BackgroundMethodAutomated Adjoints of Coupled PDE-ODE Systems
Farrell, P. E., Hake, J. E., Funke, S. W., & Rognes, M. E. (2019) · SIAM Journal on Scientific Computing · doi:10.1137/17m1144532 · Cited by 8
“The specific form of I ion and F are typically prescribed by a given cardiac cell model and may vary greatly in complexity: from involving a single state variable s such as the FitzHugh-Nagumo model [11] to models with e.g. 41 state variables such as the model of O’Hara et al. [21].”
MethodXu, J., & Rudy, Y. (2018) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2018.10.003 · Cited by 8
“We incorporated these parameters in a human myocyte model [18], which was paced at a cycle length of 300ms (Figure 3B).”
MethodInfluentialSelf-citationPaci, M., Passini, E., Klimas, A., Severi, S., Hyttinen, J., Rodríguez, B., & Entcheva, E. G. (2018) · Computing in cardiology · doi:10.22489/cinc.2018.086 · Cited by 8
“Q10 factors to translate the model from 37°C to 21°C [4–7].”
Conditions for the genesis of early afterdepolarization in a model of a ventricular myocyte
Chu, Z., Yang, D., & Huang, X. (2020) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.5133086 · Cited by 8
Reciprocal interaction between IK1 and If in biological pacemakers: A simulation study
Li, Y., Wang, K., Li, Q., Hancox, J. C., & Zhang, H. (2021) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1008177 · Cited by 8
Barral, Y.-S. H. M., Shuttleworth, J. G., Clerx, M., Whittaker, D. J., Wang, K., Polonchuk, L., Gavaghan, D. J., & Mirams, G. R. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.879035 · Cited by 8
“(2020) also noted that the question of initial conditions for ionic concentrations is often overlooked when fitting AP models, when they fitted the O’Hara Rudy model (O’Hara et al., 2011) to AP recordings from optical mapping experiments in human ventricular wedges.”
High throughput measurement of hERG drug block kinetics using the CiPA dynamic protocol
Windley, M. J., Farr, J., TeBay, C., Vandenberg, J. I., & Hill, A. P. (2022) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2022.107192 · Cited by 8
Ramos, A. N., Fenton, F. H., & Cherry, E. M. (2022) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-022-02685-y · Cited by 8
“An example is approximate Bayesian computation sequential Monte Carlo (ABC-SMC) [19, 20], which has been applied to obtain parameter distributions for the Hodgkin-Huxley neural model [15] and for the O’Hara et al. model [21] of cardiac cells [22].”
MethodVerkerk, A. O., Doszpod, I. J., Mengarelli, I., Magyar, T., Polyák, A., Pászti, B., Efimov, I. R., Wilders, R., & Koncz, I. (2022) · Biomedicines · doi:10.3390/biomedicines10112987 · Cited by 8
“Effects of ACh-induced changes in the L-type Ca2+ current (ICaL) and the rapid and slow delayed rectifier K+ currents (IKr and IKs, respectively) on the electrical activity of the O’Hara–Rudy human ventricular cell model [44] at 1 Hz.”
BackgroundMethodInfluentialAlvarez, J. A. E., Jafri, M. S., & Ullah, A. (2023) · Biomolecules · doi:10.3390/biom13081259 · Cited by 8
“recordings for human ventricular epicardial cell types) [16]; Bárándi et al.”
BackgroundMethodInfluentialHigh frequency stimulation of cardiac myocytes: A theoretical and computational study
Weinberg, S. H. (2014) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.4897618 · Cited by 8
Quadratic adaptive algorithm for solving cardiac action potential models
Chen, M.-H., Chen, P.-Y., & Luo, C. (2016) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2016.09.001 · Cited by 8
Abidi, Y., Bellassoued, M., Mahjoub, M., & Zemzemi, N. (2019) · Mathematical Modelling of Natural Phenomena · doi:10.1051/mmnp/2018060 · Cited by 8
“Rudy and his collaborators proposed series of models based on the HH formalism which are chronologically more and more complex [34, 36, 37, 40, 45] and take into account more and more the physiological behaviors of the ion channels.”
BackgroundLoewe, A., Mesa, M. H., Pilia, N., Severi, S., & Dössel, O. (2018) · Computing in cardiology · doi:10.22489/cinc.2018.068 · Cited by 9
“The changes for the M cells compared to the parent model are within the experimentally reported error margins [8] except for AmpNaK.”
ResultAltomare, C., Bartolucci, C., Sala, L., Balbi, C., Burrello, J., Pietrogiovanna, N., Burrello, A., Bolis, S., Panella, S., Arici, M., et al. (2023) · Communications Biology · doi:10.1038/s42003-023-04674-9 · Cited by 8
Nieto-Marín, P., Jiménez‐Jáimez, J., Tinaquero, D., Alfayate, S., Utrilla, R. G., del Rey, M. D. M. R. V., Perín, F., Sarquella‐Brugada, G., Monserrat, L., Brugada, J., et al. (2019) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2018.03.012 · Cited by 8
“5 mutations, alone or combined, on the AP characteristics were simulated using a validated model of human endocardial ventricular myocytes (Figure 6).(14) The model was run in baseline conditions (WT) or by introducing the kinetic and conductance changes produced by the p.”
MethodA Comprehensive Comparison of GPU Implementations of Cardiac Electrophysiology Models
Kaboudian, A., Velasco-Perez, H. A., Iravanian, S., Shiferaw, Y., Cherry, E. M., & Fenton, F. H. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-31514-6_2 · Cited by 8
Aguado‐Sierra, J., Butakoff, C., Brigham, R. C., Baron, A. K., Houzeaux, G., Palmero, M. J. G., Carreras, F., Rama, D. F., Iaizzo, P. A., Iles, T. L., et al. (2021) · medRxiv · doi:10.1101/2021.04.21.21255870 · Cited by 8
Kohjitani, H., Koda, S., Himeno, Y., Makiyama, T., Yamamoto, Y., Yoshinaga, D., Wuriyanghai, Y., Kashiwa, A., Toyoda, F., Zhang, Y., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-23398-0 · Cited by 7
“The baseline model of hiPSC-CM membrane excitation 97 The baseline model of hiPSC-CMs was essentially the same as the human ventricular cell model (hVC 98 model), which has been fully described in references [10,11] and shares many comparable characteristics with 99 other human models so far published [8,9].”
ResultWahid, M., Saqib, F., Abbas, G., Shah, S., Alshammari, A., Albekairi, T. H., Ali, A., Khurm, M., & Mubarak, M. S. (2024) · Frontiers in Pharmacology · doi:10.3389/fphar.2023.1277594 · Cited by 7
Jæger, K. H., Charwat, V., Wall, S., Healy, K. E., & Tveito, A. (2024) · npj Systems Biology and Applications · doi:10.1038/s41540-024-00347-3 · Cited by 7
“We have seen that the original model runs into difficulties when the calcium current is blocked.”
BackgroundEscobar, F., Friis, S., Adly, N., Brinkwirth, N., Gomis-Tena, J., Sáiz, J., Klaerke, D. A., Stoelzle‐Feix, S., & Romero, L. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108293 · Cited by 7
Jæger, K. H., Louch, W. E., & Tveito, A. (2025) · Physiological Reports · doi:10.14814/phy2.70461 · Cited by 7
Nonaxisymmetric mathematical model of the cardiac left ventricle anatomy
Pravdin, S. F. (2013) · Russian journal of biomechanics · Cited by 7
Foo, K. S., Lehtinen, M. L., Leung, C. Y., Lian, X. L., Xu, J., Keung, W., Geng, L., Kolstad, T. R., Thams, S., Wong, A. O. T., et al. (2020) · Molecular Therapy · doi:10.1016/j.ymthe.2020.11.015 · Cited by 7
Nicolò, C., Sips, F. L. P., Vaghi, C., Baretta, A., Carbone, V., Emili, L., & Bursi, R. (2022) · Annals of Biomedical Engineering · doi:10.1007/s10439-022-03052-6 · Cited by 7
“…TdP Risk Screen was built using a machine learning tool, based on cellular simulations of the O’Hara et al. human ventricular action potential model 21 and existing pharmacological data (IC 50 and effective free therapeutic plasma concentration) for 109 drugs of known torsadogenic risk from the…”
MethodNizamieva, A., Frolova, S. R., Slotvitsky, М. М., Sandaara, K., Tsvelaya, V. A., Никитина, А. В., Sergeevichev, D., & Игоревич, А. К. (2022) · Naunyn-Schmiedeberg s Archives of Pharmacology · doi:10.1007/s00210-022-02332-1 · Cited by 7
“The influence of a substance on the operation of ion channels is not limited to a change in peak amplitude; in general, it is possible to change the characteristic times channel activation and deactivation (such effects can occur, for example, during adreno stimulation) (O'Hara et al. 2011).”
BackgroundqInward variability-based in-silico proarrhythmic risk assessment of drugs using deep learning model
Jeong, D. U., Nurul Qashri Mahardika, T., Marcellinus, A., & Lim, K. M. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.1080190 · Cited by 7
“This study used the Tomek-Ohara Rudy model (ToR-ORD model), which was developed to integrate and delineate wellmimicked healthy and diseased hearts according to drug effects by (O’Hara et al., 2011; Dutta et al., 2017; Tomek et al., 2019).”
MethodBueno‐Palomeque, F. L., Mountris, K. A., Ortigosa, N., Bailón, R., Bijnens, B. H., Crispi, F., Pueyo, E., Mincholé, A., & Laguna, P. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3297550 · Cited by 7
“human ventricular cell electrophysiology by the O’Hara-Rudy AP model for healthy tissue [16].”
MethodAguado‐Sierra, J., Brigham, R. C., Baron, A. K., Dominguez-Gomez, P., Houzeaux, G., Palmero, M. J. G., Carreras, F., Rama, D. F., Vázquez, M., Iaizzo, P. A., et al. (2023) · Methods in molecular biology · doi:10.1007/978-1-0716-3449-3_14 · Cited by 7
Enabling Tissue-Scale Cardiac Simulations Using Heterogeneous Computing on Tianhe-2
Langguth, J., Lan, Q., Gaur, N., Cai, X. H., Wen, M., & Zhang, C. (2016) · IEEE International Conference on Parallel and Distributed Systems (ICPADS) · doi:10.1109/icpads.2016.0114 · Cited by 7
“…most half of that is available for applications [16] Our multiscale model of stochastic calcium handling in a ventricular myocyte is similar to [2], combined with the O'Hara-Rudy (ORd) model [17] of electrophysiological current formulation for a healthy human cardiac ventricular action potential.”
Bystricky, W., Maier, C., Gintant, G. A., Bergau, D., Kamradt, K., Welsh, P., & Carter, D. (2019) · PLoS ONE · doi:10.1371/journal.pone.0204712 · Cited by 7
Escobar, F., Gomis-Tena, J., Sáiz, J., & Romero, L. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107148 · Cited by 7
Lee, W., Ng, B., Mangala, M. M., Perry, M., Subbiah, R. N., Vandenberg, J. I., & Hill, A. P. (2023) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.122.011574 · Cited by 7
Forouzandehmehr, M., Paci, M., Hyttinen, J., & Koivumäki, J. T. (2024) · Disease Models & Mechanisms · doi:10.1242/dmm.050365 · Cited by 7
Mahati, E., Li, P., Kurata, Y., Maharani, N., Ikeda, N., Sakata, S., Ogura, K., Miake, J., Aiba, T., Shimizu, W., et al. (2016) · Circulation Journal · doi:10.1253/circj.cj-16-0712 · Cited by 7
Mechanistic investigation of Ca2+ alternans in human heart failure and its modulation by fibroblasts
Mora, M. T., Gómez, J. F., Morley, G. E., Ferrero, J. M., & Trénor, B. (2019) · PLoS ONE · doi:10.1371/journal.pone.0217993 · Cited by 7
Restitution and Stability of Human Ventricular Action Potential at High and Variable Pacing Rate
Zaniboni, M. (2019) · Biophysical Journal · doi:10.1016/j.bpj.2019.08.020 · Cited by 7
“’s human ventricular AP model (29), paced with stimulation protocols in which CL changes beat-tobeat according, in turn, to sinusoidal, saw-tooth, and random law.”
BackgroundMethodResultInfluentialA coupled monodomain solver with optimal memory usage for the simulation of cardiac wave propagation
Chamakuri, N., & Kügler, P. (2020) · Applied Mathematics and Computation · doi:10.1016/j.amc.2020.125212 · Cited by 7
An Unsupervised Domain Adaptation Approach to Classification of Stem Cell-Derived Cardiomyocytes
Pacheco, C., & Vidal, R. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-32239-7_89 · Cited by 7
Safety pharmacology methods and models in an evolving regulatory environment
Pugsley, M. K., de Korte, T., Authier, S., Huang, H., Accardi, M. V., & Curtis, M. J. (2017) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2017.04.012 · Cited by 7
Zhang, Y., Zhang, K., Prakosa, A., James, C. A., Zimmerman, S. L., Carrick, R. T., Sung, E., Gasperetti, A., Tichnell, C., Murray, B. A., et al. (2023) · eLife · doi:10.7554/elife.88865.1 · Cited by 7
Brennan, S., Chen, S., Makwana, S., Esposito, S., McGuinness, L. R., Alnaimi, A. I. M., Sims, M. W., Patel, M., Aziz, Q. H., Ojake, L., et al. (2024) · British Journal of Pharmacology · doi:10.1111/bph.16390 · Cited by 6
“Action potentials were simulated in the OpenCOR 0.7.1 (RRID:SCR_ 019001) environment using an established ‘ Rudy-O'Hara-CiPA version ’ ventricular cardiomyocyte model (Chang et al., 2017; Dutta et al., 2017; Li, Dutta, et al., 2017; O'Hara et al., 2011).”
InfluentialA possible path to persistent re-entry waves at the outlet of the left pulmonary vein
Jæger, K. H., & Tveito, A. (2024) · npj Systems Biology and Applications · doi:10.1038/s41540-024-00406-9 · Cited by 6
Huethorst, E., Bishop, M. J., Burton, F. L., Denning, C. N., Gadegaard, N., Myles, R. C., & Smith, G. L. (2025) · Cardiovascular Research · doi:10.1093/cvr/cvaf034 · Cited by 6
“40 Adult myocardium paced at short cycle lengths (300 ms, 3.3 Hz) commonly shows APD alternans associated with a DI ∼ 50–70 ms. 40,43 This is comparable with the threshold DI for alternans and 2:1 block observed during the EHT pacing protocol ( Figure 2B and F ).”
Influential
Metadata
- Authors
- O'Hara, T., Virág, L., Varró, A., & Rudy, Y.
- Affiliations
- University of Szeged (HU)
- Washington University in St. Louis (US)
- Corresponding author
- Rudy, Yoram
- Venue
- PLoS Computational Biology
- Publisher
- Public Library of Science (PLoS)
- Published
- 2011-05-26
- Volume
- 7
- Issue
- 5
- Pages
- e1002061
- ISSN
- 1553-734X (ISSN-L)
- 1553-7358
- PMC
- PMC3102752
- OpenAlex
- W2115765852
- Cited by
- 1,196
- References
- 110
- Citations by year
- 2026: 50 · 2025: 61 · 2024: 89 · 2023: 102 · 2022: 95 · 2021: 97 · 2020: 118 · 2019: 98 · 2018: 89 · 2017: 100 · 2016: 83 · 2015: 67 · 2014: 63 · 2013: 47 · 2012: 27
- FWCI
- 31.78
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- PLoS Computational Biology (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- SZTE Publicatio Repozitórium (University of Szeged) (acceptedVersion, other-oa)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Science Foundation (0929633)
- American Heart Association
- Fondation Leducq
- Hungarian Scientific Research Fund (OTKA CNK-77855)
- Nemzeti Kutatási és Technológiai Hivatal
- National Institutes of Health
- U.S. Public Health Service (R01-HLR01033343-26)
- National Heart, Lung, and Blood Institute (R01HL049054, R01HL-049054-18, R56HL049054)
- Division of Chemical, Bioengineering, Environmental, and Transport Systems
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion channel regulation and function
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- cardiac electrophysiology models, L-type calcium current, transient outward potassium current, Na+/Ca2+ exchanger, inward rectifier potassium current, action potential duration restitution, rate dependence, early afterdepolarizations, calcium alternans, calcium/calmodulin-dependent protein kinase, SERCA, intracellular sodium, late sodium current, transmural heterogeneity, human ventricular myocytes
- MeSH terms
- Action Potentials, Arrhythmias, Cardiac, Calmodulin, Heart Ventricles, Humans, Models, Cardiovascular, Reproducibility of Results, Sodium Channels, Ventricular Function, Patch-Clamp Techniques, Computational Biology, Calcium Channels, L-Type, Myocytes, Cardiac
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.