Credibility assessment of patient-specific computational modeling using patient-specific cardiac modeling as an exemplar
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
Reliable and robust simulation of individual patients using patient-specific models (PSMs) is one of the next frontiers for modeling and simulation (M&S) in healthcare. PSMs, which form the basis of digital twins, can be employed as clinical tools to, for example, assess disease state, predict response to therapy, or optimize therapy. They may also be used to construct virtual cohorts of patients, for in silico evaluation of medical product safety and/or performance. Methods and frameworks have recently been proposed for evaluating the credibility of M&S in healthcare applications. However, such efforts have generally been motivated by models of medical devices or generic patient models; how best to evaluate the credibility of PSMs has largely been unexplored. The aim of this paper is to understand and demonstrate the credibility assessment process for PSMs using patient-specific cardiac electrophysiological (EP) modeling as an exemplar. We first review approaches used to generate cardiac PSMs and consider how verification, validation, and uncertainty quantification (VVUQ) apply to cardiac PSMs. Next, we execute two simulation studies using a publicly available virtual cohort of 24 patient-specific ventricular models, the first a multi-patient verification study, the second investigating the impact of uncertainty in personalized and non-personalized inputs in a virtual cohort. We then use the findings from our analyses to identify how important characteristics of PSMs can be considered when assessing credibility with the approach of the ASME V&V40 Standard, accounting for PSM concepts such as inter- and intra-user variability, multi-patient and "every-patient" error estimation, uncertainty quantification in personalized vs non-personalized inputs, clinical validation, and others. The results of this paper will be useful to developers of cardiac and other medical image based PSMs, when assessing PSM credibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In previous work, we explored credibility of patient-specific models [9]. We considered what verification, validation and uncertainty quantification each mean for PSMs, unique considerations that arise for PSM credibility assessment, and discussed how to apply ASME V&V40 2018 to PSMs.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [9]
The cited source says what the claim attributes to it.
In the citing paper
“First, we noted that with PSMs it is common to perform calculation verification studies such as grid refinement studies using a single, assumed representative, patient.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [9]
The cited source says what the claim attributes to it.
In the citing paper
“User variability was also identified in [9] as a potential source of error for PSMs.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [9]
The cited source says what the claim attributes to it.
In the citing paper
“In our previous work for patient-specific models we identified unique calculation verification considerations that arise for PSMs [9].”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [9]
The cited source says what the claim attributes to it.
In the citing paper
“As an example, in [9] we performed UQ for a cardiac virtual cohort simulation study and demonstrated that the study conclusion is not affected by uncertainty in personalized anatomic regions.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [9]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439 · cited 1×
“However, all publications reviewed fell into one of these categories, and important PSMs from other fields do so as well, for example Heartflow [1] is a PSM-CT and the Virtual Family [60] is a PSM-VC.”
BackgroundA model for human ventricular tissue
ten Tusscher, K. H. W. J., Noble, D., Noble, P. J., & Panfilov, A. V. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00794.2003 · Cited by 1,416 · cited 1×
“cell model [37], using the cardiac EP simulator Chaste [52].”
MethodO'Hara, T., Virág, L., Varró, A., & Rudy, Y. (2011) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1002061 · Cited by 1,196
Alternans and spiral breakup in a human ventricular tissue model
ten Tusscher, K. H. W. J., & Panfilov, A. V. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00109.2006 · Cited by 1,122
The ‘Digital Twin’ to enable the vision of precision cardiology
Corral-Acero, J., Margara, F., Marciniak, M., Rodero, C., Loncaric, F., Feng, Y., Gilbert, A., Fernandes, J. F., Bukhari, H. A., Wajdan, A., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa159 · Cited by 932 · cited 1×
“Alternatively, it has been defined more precisely as a “comprehensive, virtual tool that integrates coherently and dynamically the clinical data acquired over time for an individual using mechanistic and statistical models” [5].”
BackgroundModels of cardiac tissue electrophysiology: Progress, challenges and open questions
Clayton, R. H., Bernus, O., Cherry, E. M., Dierckx, H., Fenton, F. H., Mirabella, L., Panfilov, A. V., Sachse, F. B., Seemann, G., & Zhang, H. (2011) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2010.05.008 · Cited by 585
Bayer, J. D., Blake, R. C., Plank, G., & Trayanova, N. A. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0593-5 · Cited by 557 · cited 1×
“Each model has fibers generated using a rule-based method [51].”
MethodArevalo, H. J., Vadakkumpadan, F., Guallar, E., Jebb, A., Malamas, P., Wu, K. C., & Trayanova, N. A. (2016) · Nature Communications · doi:10.1038/ncomms11437 · Cited by 465 · cited 3×
“For example, a study comparing model-based ablation targets against clinician-chosen ablation targets [13] or a study evaluating the performance of a PSM arrhythmia risk stratification tool that compares the model risk score against a clinical study endpoint of appropriate ICD firing or cardiac death [16].”
BackgroundA novel computational model of the human ventricular action potential and Ca transient
Grandi, E., Pasqualini, F. S., & Bers, D. M. (2010) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2009.09.019 · Cited by 450
Chaste: An Open Source C++ Library for Computational Physiology and Biology
Mirams, G. R., Arthurs, C. J., Bernabeu, M. O., Bordas, R., Cooper, J., Corrias, A., Davit, Y., Dunn, S.-J., Fletcher, A. G., Harvey, D. G., et al. (2013) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1002970 · Cited by 423
Research works printed but not linked: 3
- ASME. V&V 40–2018 Assessing Credibility of Com putational Modeling through Verification and Validation: Application to Medical Devices. 2018.
- Costa CM. A Virtual Cohort of Twenty-four Left-ventricular Models of Ischemic Cardiomyopathy Patients. 2020.
- Kreinovich V, Nguyen HT, Niwitpong S-a. Statistical hypothesis testing under interval uncertainty: An overview. International Journal of Intelligent Technologies and Applied Statistics. 2008; 1(1): 1– 32.
Cited by
Building Digital Twins for Cardiovascular Health: From Principles to Clinical Impact
Sel, K., Osman, D., Zare, F., Shahrbabak, S. M., Brattain, L. J., Hahn, J., Inan, O. T., Mukkamala, R., Palmer, J., Paydarfar, D., et al. (2024) · Journal of the American Heart Association · doi:10.1161/jaha.123.031981 · Cited by 210
“102,105 Yet, given the diverse nature of data and sensor types, statistical and mechanistic models, and underlying assumptions in building a digital twin, validation proves to be difficult.”
BackgroundA scoping review of human digital twins in healthcare applications and usage patterns
Tudor, B. H., Shargo, R., Gray, G. M., Fierstein, J. L., Kuo, F. H., Burton, R., Johnson, J. T., Scully, B. B., Asante‐Korang, A., Rehman, M., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01910-w · Cited by 149
“For instance, Galappaththige et al. outline a comprehensive roadmap for incorporating VVUQ practices into the development of personalized digital models 162 .”
Strocchi, M., Longobardi, S., Augustin, C. M., Gsell, M. A. F., Petras, A., Rinaldi, C. A., Vigmond, E. J., Plank, G., Oates, C. J., Wilkinson, R. D., et al. (2023) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1011257 · Cited by 67
Credibility assessment of in silico clinical trials for medical devices
Pathmanathan, P., Aycock, K., Badal, A., Bighamian, R., Bodner, J., Craven, B. A., & Niederer, S. (2024) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1012289 · Cited by 62
Viceconti, M., & Emili, L. (2024) · Synthesis lectures on biomedical engineering · doi:10.1007/978-3-031-48284-7 · Cited by 56
Current progress of digital twin construction using medical imaging
Zhao, F., Wu, Y., Hu, M., Chang, C., Liu, R., Qiu, R. L. J., & Yang, X. (2025) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.70226 · Cited by 78
Aycock, K. I., Battisti, T., Peterson, A., Jiang, Y. D., Kreuzer, S. M., Capelli, C., Pant, S., Pathmanathan, P., Hoganson, D. M., Levine, S. M., et al. (2024) · Frontiers in Medicine · doi:10.3389/fmed.2024.1433372 · Cited by 40
A systematic review of cardiac in-silico clinical trials
Rodero, C., Baptiste, T. M. G., Barrows, R. K., Keramati, H., Sillett, C., Strocchi, M., Lamata, P., & Niederer, S. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/acdc71 · Cited by 44
Atrial fibrosis in atrial fibrillation: Mechanisms, mapping techniques and clinical applications
Horrach, C. V., Bevis, L., Nwanna, C., Zolotarev, A. M., Ehnesh, M., Misghina, S. B., Al‐Aidarous, S., Honarbakhsh, S., & Roney, C. H. (2025) · The Journal of Physiology · doi:10.1113/jp288680 · Cited by 28
“Validation remains a challenge as a result of the limited experimental data available, and model credibility assessment methods are still evolving (Galappaththige et al., 2022).”
A Review of Personalised Cardiac Computational Modelling Using Electroanatomical Mapping Data
Jaffery, O. A., Melki, L., Slabaugh, G., Good, W. W., & Roney, C. H. (2024) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2023.25 · Cited by 24
“84,85 Computational intensity : simulating cardiac EP at high spatiotemporal resolution requires significant computational resources, making real-time or large-scale simulations challenging.”
BackgroundChallenges and opportunities in uncertainty quantification for healthcare and biological systems
Kimpton, L. M., Păun, L. M., Colebank, M. J., & Volodina, V. (2025) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2024.0232 · Cited by 30
“More resources are now dedicated towards modelling for medical device development [35], ‘patient-specific’ models [36] and in silico clinical trails [37].”
The biomechanical evolution of the uterus and cervix and fetal growth in human pregnancy
Louwagie, E., Russell, S. R., Hairston, J. C., Nottman, C., Nhan‐Chang, C., Fuchs, K. M., Gyamfi‐Bannerman, C., Booker, W. A., Andrikopoulou, M., Friedman, A. M., et al. (2024) · npj Women s Health · doi:10.1038/s44294-024-00038-8 · Cited by 14
“Advancements in in-silico methods for clinical study havefacilitatedvastresearchin fi eldssuchascardiovascular, cartilage, and tumor growth biomechanics 11 – 13 .”
Promising tools for future drug discovery and development in antiarrhythmic therapy
Mondéjar‐Parreño, G., Sánchez-Pérez, P., Cruz, F. M., & Jalife, J. (2024) · Pharmacological Reviews · doi:10.1124/pharmrev.124.001297 · Cited by 17
Martinez‐Navarro, H., Zhou, X., & Rodríguez, B. (2024) · Annual Review of Physiology · doi:10.1146/annurev-physiol-042022-020541 · Cited by 13
Rad, F. S., Bitaraf, E., Jafarpour, M., & Juan, L. I. (2026) · JMIR Cardio · doi:10.2196/78499 · Cited by 23
“The key insights are as follows: • Electrophysiology models were the most common (19 studies [11,17,18,20,21,25,27,28,30,34,35,37,39, 41,43,44,46,51,54]).”
Design specifications for biomedical virtual twins in engineered adoptive cellular immunotherapies
Weirauch, U., Kreuz, M., Birkenbihl, C., Alb, M., Quaranta, M., Calzone, L., Orozco-Ruiz, S., Binder, S., Fischer, L., Clavreul, S., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01809-6 · Cited by 14
“However, bidirectional interchange is subject to uncertainties in both directions, impacting the credibility, i.e., the trust in “ the predictive capability ” 68,69 , of a VT.”
InfluentialKaboudian, A., Gray, R. A., Uzelac, I., Cherry, E. M., & Fenton, F. H. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108456 · Cited by 9
Catalano, C., Scuoppo, R., Turgut, T., Bouwman, V., Götzen, N., Cannata, S., Gentile, G., Gandolfo, C. M., & Pasta, S. (2025) · APL Bioengineering · doi:10.1063/5.0280958 · Cited by 7
“In the cardiovascular field, Galappaththige et al. 15 expanded the ASME V&V 40 framework to encompass patient-specific cardiac models.”
Bridio, S., Deceuninck, P., Whelan, M., & Worth, A. P. (2025) · Science Progress · doi:10.1177/00368504251344145 · Cited by 9
Scuoppo, R., Catalano, C., Turgut, T., Götzen, N., Cannata, S., Gentile, G., Gandolfo, C. M., & Pasta, S. (2025) · APL Bioengineering · doi:10.1063/5.0280959 · Cited by 6
“9 In the context of patient-specific modeling, Galappaththige et al. 10 employed an in silico cardiac electrophysiology model to estimate uncertainty arising from population variability, demonstrating the role of UQ in supporting robust model-based decision-making.”
Gillette, K. K., Winkler, B., Kurath‐Koller, S., Scherr, D., Vigmond, E. J., Bär, M., & Plank, G. (2024) · EP Europace · doi:10.1093/europace/euae223 · Cited by 7
“66”
Numerical accuracy of closed-loop steady state in a zero-dimensional cardiovascular model
van Osta, N., van den Acker, G. P. H., van Loon, T., Arts, T. G. J., Delhaas, T., & Lumens, J. (2025) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2024.0208 · Cited by 5
“Effective software quality assurance ensures that computational models perform as expected under various (patho-)physiological conditions [11].”
Parametric Solid Models of the At-Term Uterus From Magnetic Resonance Images
Louwagie, E., Rajasekharan, D., Feder, A. D., Fang, S., Nhan‐Chang, C., Mourad, M., & Myers, K. M. (2024) · Journal of Biomechanical Engineering · doi:10.1115/1.4065109 · Cited by 5
A verification study on the accuracy of virtual thoracic endovascular aneurysm repair procedure
Campo, G. D., Barati, S., Ramella, A., Heijmen, R. H., Trimarchi, S., Migliavacca, F., & Luraghi, G. (2025) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2025.112875 · Cited by 4
Scuoppo, R., Catalano, C., Crascì, F., & Pasta, S. (2025) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-025-00801-1 · Cited by 4
“Apart from our current study, another significant exploration of ASME V&V40 with a focus on patient-specific model credibility is the research conducted by Galappaththige and colleagues [26] concerning patient-specific cardiac electrophysiological modeling.”
Evolution of digital twins in precision health applications: a scoping review studyPreprint
Bian, J., Huang, Y., Dai, H., Xu, J., Wei, R., Sun, L., Guo, Y. M., & Guo, J. S. (2024) · Research Square · doi:10.21203/rs.3.rs-4612942/v1 · Cited by 8
Xie, H., Huang, Q., Yu, H., Qu, Y., Yuan, M., Wu, H., Wang, J., Zhu, Z., & Li, Z. (2025) · Information Fusion · doi:10.1016/j.inffus.2025.103957 · Cited by 6
Fontana, C., & Ajabshir, S. Z. (2026) · Computation · doi:10.3390/computation14070143 · Cited by 4
Uterus and cervix anatomical changes and cervix stiffness evolution throughout pregnancyPreprint
Louwagie, E., Russell, S. R., Hairston, J. C., Nottman, C., Nhan‐Chang, C., Fuchs, K. M., Gyamfi‐Bannerman, C., Booker, W. A., Andrikopoulou, M., Friedman, A. M., et al. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.05.01.592023 · Cited by 3
“Advancements in in-silico methods for clinical study have facilitated vast research in fields such as cardiovascular, cartilage, and tumor growth biomechanics [11–13].”
MethodDigital twins for cardiopulmonary medicine: the case for pulmonary arterial hypertension
Niederer, S., Balmus, M., Burr, C., Chico, T., Clayton, R. H., Bai, W., Rangel-Smith, C., Wagg, D., Wilkinson, R. D., Wang, S., et al. (2026) · American Journal of Respiratory and Critical Care Medicine · doi:10.1093/ajrccm/aamag082 · Cited by 2
Kalinich, M., Luccarelli, J., Maria, J. P. S., Moss, F., & Torous, J. B. (2026) · BMJ Mental Health · doi:10.1136/bmjment-2026-302626 · Cited by 6
Amiodarone prevents wave front-tail interactions in patients with heart failure: an in silico study
Gray, R. A., & Franz, M. R. (2023) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00227.2023 · Cited by 1
Kostelich, E. J., Xu, Y., Calderón-Valero, C. E., Harris, D. C., Alcantar-Garibay, O., Gomez-Castro, G., On, T. J., Dortch, R. D., Kuang, Y., & Preul, M. C. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2025.1647144 · Cited by 1
Wu, W., Shi, Z., & Pang, Q. (2026) · Biofabrication · doi:10.1088/1758-5090/ae647e · Cited by 3
“These models usually fail to integrate key systemic physiological factors, such as immune response, innervation and hormone regulation, which are essential for successful regeneration [85, 86].”
Buonocunto, M., Jung, A., Meier, S., & Heijman, J. (2026) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2026.2674735 · Cited by 1
“Recently, a first implementation of these standards in digital twins of cardiac electrophysiology has been reported [94], but only a limited number of further applications have been described in other areas of cardiac digital twinning [95–97], underscoring how demanding compliance with these…”
Ramezani, A., Seefeldt, T., Keller, S. P., Hackmann, A. E., Osho, A. A., Rabi, S. A., & Nezami, F. R. (2026) · medRxiv · doi:10.64898/2026.01.01.26343307 · Cited by 1
Kulesza, A. J., Loewe, A., Stenti, A., Nicolò, C., Orcajo, E. M., Courcelles, E., Sips, F. L. P., Pappalardo, F., Russo, G. L., Horner, M., et al. (2024) · Synthesis lectures on biomedical engineering · doi:10.1007/978-3-031-48284-7_3 · Cited by 2
Gray, R. A. (2025) · Heart Rhythm · doi:10.1016/j.hrthm.2024.12.044
Striking the balance: Complexity, simplicity, and credibility in mathematical biology
Rodero, C., & Niederer, S. (2025) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2504067122
Munipalle, M., Dang, A., Celiz, A. D., Li, J., & Li‐Jessen, N. Y. K. (2026) · Tissue Engineering Part B Reviews · doi:10.1177/19373368261449957 · Cited by 2
Systems biology during 20 years of PLoS Computational Biology
Alber, M., Birtwistle, M. R., Finley, S. D., & Mendes, P. (2026) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1014465
“ML approaches are also used for developing personalized models and digital twins in biology and healthcare [39–42].”
Verification, Validation and Uncertainty Quantification of Cardiac Electrophysiological Models
Pathmanathan, P. (2026) · Springer eBooks · doi:10.1007/978-3-032-09180-2_19
Pandelani, T., & Nemavhola, F. J. (2026) · Bioengineering · doi:10.3390/bioengineering13090991
Recent Developments, Applications, and Future Prospects of Advanced Hearts-on-a-Chip
Kang, A., Lee, H., Park, G., Kim, T., Kim, H., Park, T., Staley, S., Kang, M., & Kang, Y. B. (2026) · Micromachines · doi:10.3390/mi17091079
Integration of Multi-Omics in AI-Based Models for Predictive Oncology
Nativel, A., Dandou, S., Favier, F., Lesage, C., Mangé, A., Aligon, J., Coopman, P. J., & Larive, R. M. (2026) · Genes · doi:10.3390/genes17101231
Metadata
- Authors
- Galappaththige, S., Gray, R. A., Costa, C. M., Niederer, S., & Pathmanathan, P.
- Affiliations
- United States Food and Drug Administration (US)
- King's College London (GB)
- Corresponding author
- Pathmanathan, Pras
- Venue
- PLoS Computational Biology
- Publisher
- Public Library of Science (PLoS)
- Published
- 2022-10-10
- Volume
- 18
- Issue
- 10
- Pages
- e1010541
- ISSN
- 1553-734X (ISSN-L)
- 1553-7358
- PMC
- PMC9550052
- OpenAlex
- W4304092601
- Cited by
- 45
- References
- 54
- Citations by year
- 2026: 13 · 2025: 15 · 2024: 14 · 2023: 3
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- public-domain
- creativecommons.org/publicdomain/zero/1.0/ (vor)
- Locations
- PLoS Computational Biology (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- U.S. Food and Drug Administration
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Social Sciences › Education › Simulation-Based Education in Healthcare
- Social Sciences › Decision Sciences › Management Science and Operations Research › Simulation Techniques and Applications
- Keywords
- patient-specific models, credibility assessment, digital twin, verification and validation, uncertainty quantification, virtual patient cohorts, ventricular model, clinical validation
- MeSH terms
- Computer Simulation, Heart, Humans, Cohort Studies, Uncertainty, Patient-Specific Modeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.