Abstract
The recent introduction of fluorescent bead-based technology, allowing the measurement of multiples analytes in a single 25-50 microl sample has revolutionized the study of cytokine responses. However, such multiplex approaches may compromise the ability of these assays to accurately measure actual cytokine levels. This study evaluates the performance of three commercially available multiplex cytokine fluorescent bead-based immunoassays (Bio-Rad's Cytokine 17-plex kit; LINCO Inc's 29-plex kit; and RnD System's Fluorokine-Multi Analyte Profiling (MAP) base kit A and B). The LINCO Inc kit was found to be the most sensitive assay for measuring concentrations of multiple recombinant cytokines in samples that had been spiked with serial dilutions of the standard provided by the manufacturer, followed respectively by the RnD Fluorokine-(MAP) and Bio-Rad 17-plex kits. A positive correlation was found in the levels of IFN-gamma measured in antigen stimulated whole blood culture supernatants by the LINCO Inc 29-plex, RnD Fluorokine-(MAP) and RnD system IFN-gamma Quantikine ELISA kits across a panel of controls and stimulated samples. Researchers should take the limitation of such multiplexed assays into account when planning experiments and the most appropriate use for these tests may currently be as screening tools for the selection of promising markers for analysis by more sensitive techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Finkelman, F. D., Shea-Donohue, T., Goldhill, J., Sullivan, C. A., Morris, S. C., Madden, K. B., Gause, W. C., & Urban, J. F. (1997) · Annual Review of Immunology · doi:10.1146/annurev.immunol.15.1.505 · Cited by 643 · cited 1×
“Cytokines are important modulators of immune response pathways [7,18,19].”
BackgroundKhan, S. S., Smith, M. S., Reda, D., Suffredini, A. F., & McCoy, J. P. (2004) · Cytometry Part B: Clinical Cytometry · doi:10.1002/cyto.b.20021 · Cited by 354 · cited 2×
“[11] have comparatively assessed multiplex kits from LINCO Research, BioRad Laboratories, RnD Systems and Biosource International and compared them to an enzyme-linked immunosorbant assay (ELISA).”
MethodduPont, N. C., Wang, K., Wadhwa, P. D., Culhane, J. F., & Nelson, E. L. (2005) · Journal of Reproductive Immunology · doi:10.1016/j.jri.2005.03.005 · Cited by 318 · cited 1×
“[5], a very strong correlation between the level of IFN-c measured by ELISA and the LINCO-plex kit in whole blood culture supernatant was found in the present study.”
ResultOpalka, D., Lachman, C. E., MacMullen, S. A., Jansen, K. U., Smith, J. F., Chirmule, N., & Esser, M. T. (2003) · Clinical and Vaccine Immunology · doi:10.1128/cdli.10.1.108-115.2003 · Cited by 276 · cited 1×
“The reduced sample volume and time-saving advantages of the luminex system have made it an attractive method for large-scale cross-sectional, association or cohort studies which investigate the host immune response [1,13,15,16].”
Methodde Jager, W., Prakken, B. J., Bijlsma, J. W. J., Kuis, W., & Rijkers, G. T. (2005) · Journal of Immunological Methods · doi:10.1016/j.jim.2005.03.009 · Cited by 258
Cytokines in innate host defense in the lung
Strieter, R. M., Belperio, J. A., & Keane, M. P. (2002) · Journal of Clinical Investigation · doi:10.1172/jci15277 · Cited by 198 · cited 1×
“Cytokines are important modulators of immune response pathways [7,18,19].”
BackgroundKellar, K. L., Kalwar, R. R., Dubois, K. A., Crouse, D., Chafin, W. D., & Kane, B.-E. (2001) · Cytometry · doi:10.1002/1097-0320(20010901)45:1<27::aid-cyto1141>3.0.co;2-i · Cited by 194
Liu, M. Y., Xydakis, A. M., Hoogeveen, R. C., Jones, P. H., Smith, E. O., Nelson, K. W., & Ballantyne, C. M. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.047084 · Cited by 178 · cited 1×
“It is clear that, at the present moment, the theoretical capabilities of this new technology cannot be fully achieved in practice [12].”
BackgroundSolid-phase and bead-based cytokine immunoassay: A comparison
de Jager, W., & Rijkers, G. T. (2006) · Methods · doi:10.1016/j.ymeth.2005.11.008 · Cited by 170
Cytokines in innate host defense in the lung
Strieter, R. M., Belperio, J. A., & Keane, M. P. (2002) · Journal of Clinical Investigation · doi:10.1172/jci0215277 · Cited by 158
Cited by
Distinct Cytokine Patterns Identified from Multiplex Profiles of Murine DSS and TNBS-Induced Colitis
Alex, P., Zachos, N. C., Nguyen, T., Gonzales, L., Chen, T.-E., Conklin, L. S., Centola, M., & Li, X. (2009) · Inflammatory Bowel Diseases · doi:10.1002/ibd.20753 · Cited by 750
Prerequisites for cytokine measurements in clinical trials with multiplex immunoassays
de Jager, W., Bourcier, K., Rijkers, G. T., Prakken, B. J., & Seyfert-Margolis, V. (2009) · BMC Immunology · doi:10.1186/1471-2172-10-52 · Cited by 427
Comprehensive Analysis of Inflammatory Immune Mediators in Vitreoretinal Diseases
Yoshimura, T., Sonoda, K.-H., Sugahara, M., Mochizuki, Y., Enaida, H., Oshima, Y., Ueno, A., Hata, Y., Yoshida, H., & Ishibashi, T. (2009) · PLoS ONE · doi:10.1371/journal.pone.0008158 · Cited by 342
Aptamer-Based Electrochemical Biosensor for Interferon Gamma Detection
Liu, Y., Tuleouva, N., Ramanculov, E., & Revzin, A. (2010) · Analytical Chemistry · doi:10.1021/ac101409t · Cited by 324
Bioanalytical Chemistry of Cytokines–a Review
Stenken, J. A., & Poschenrieder, A. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.10.009 · Cited by 302
“Others have found issues between different kits with respect to the coeffici ent of variation and other figures of merit [71, 72].”
Toxicology and risk assessment of coumarin: Focus on human data
Abraham, K., Wöhrlin, F., Lindtner, O., Heinemeyer, G., & Lampen, A. (2010) · Molecular Nutrition & Food Research · doi:10.1002/mnfr.200900281 · Cited by 292
Leng, Y., Sun, K., Chen, X., & Li, W. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00382a · Cited by 258
Plasma cytokine levels during acute HIV-1 infection predict HIV disease progression
Roberts, L., Passmore, J.-A. S., Williamson, C., Little, F., Bebell, L. M., Mlisana, K., Burgers, W. A., van Loggerenberg, F., Walzl, G., Djoba Siawaya, J. F., et al. (2010) · AIDS · doi:10.1097/qad.0b013e3283367836 · Cited by 228
“Measurement of plasma cytokines Thirty cytokines were measured in plasma from HIVuninfected and HIV-infected women using high-sensitivity and human cytokine LINCOplex kits (LINCO Research, St. Charles, Missouri, USA): interleukin (IL)1a, IL-1b, IL-1 receptor agonist (ra), IL-2, IL-4, IL-5, IL-6, IL-7, IL-8, IL-10, IL-…”
BackgroundSelf-citationArora, M. (2013) · Materials and Methods · doi:10.13070/mm.en.3.175 · Cited by 216
Ajmera, V., Perito, E. R., Bass, N. M., Terrault, N. A., Yates, K. P., Gill, R., Loomba, R., Diehl, A. M., & Aouizerat, B. E. (2017) · Hepatology · doi:10.1002/hep.28776 · Cited by 179
“Cytokine detection by Luminex is comparable to that with enzyme-linked immunosorbent assay,((19,20)) but the required input plasma volume is drastically reduced.”
MethodMultisite Comparison of High-Sensitivity Multiplex Cytokine Assays
Breen, E. C., Reynolds, S. M., Cox, C., Jacobson, L. P., Magpantay, L., Mulder, C. B., Dibben, O., Margolick, J. B., Bream, J. H., Sambrano, E., et al. (2011) · Clinical and Vaccine Immunology · doi:10.1128/cvi.05032-11 · Cited by 172
“greater sensitivity of Linco assays than the Bio-Rad assay (4) and greater sensitivity of MSD assays than the BioSource or Bio-Rad assay (8, 21).”
Method
Metadata
- Authors
- Djoba Siawaya, J. F., Roberts, T., Babb, C., Black, G., Golakai, H. J., Stanley, K., Bapela, N. B., Hoal, E., Parida, S., van Helden, P., & Walzl, G.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2008-07-02
- Volume
- 3
- Issue
- 7
- Pages
- e2535
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2090866819
- Cited by
- 172
- References
- 14
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.