A Novel Modular Bioreactor to In Vitro Study the Hepatic Sinusoid
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
We describe a unique, versatile bioreactor consisting of two plates and a modified commercial porous membrane suitable for in vitro analysis of the liver sinusoid. The modular bioreactor allows i) excellent control of the cell seeding process; ii) cell culture under controlled shear stress stimulus, and; iii) individual analysis of each cell type upon completion of the experiment. The advantages of the bioreactor detailed here are derived from the modification of a commercial porous membrane with an elastomeric wall specifically moulded in order to define the cell culture area, to act as a gasket that will fit into the bioreactor, and to provide improved mechanical robustness. The device presented herein has been designed to simulate the in vivo organization of a liver sinusoid and tested by co-culturing endothelial cells (EC) and hepatic stellate cells (HSC). The results show both an optimal morphology of the endothelial cells as well as an improvement in the phenotype of stellate cells, most probably due to paracrine factors released from endothelial cells. This device is proposed as a versatile, easy-to-use co-culture system that can be applied to biomedical research of vascular systems, including the liver.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734 · cited 1×
“Organ on a chip devices have been developed to study the pathophysiology of a variety of organs, including lung [12], liver [13], gut [14] and kidney [15].”
Biomimetic tissues on a chip for drug discovery
Ghaemmaghami, A. M., Hancock, M. J., Harrington, H., Kaji, H., & Khademhosseini, A. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.029 · Cited by 359 · cited 1×
“Advances in microfabrication and polymer processing technologies have enabled the development of highly complex systems where a variety of cell types can be cocultured in a controlled environment, thereby establishing a new multidisciplinary scientific field known as organ on a chip [4–11].”
BackgroundOrgans-on-a-chip: a new tool for drug discovery
Polini, A., Prodanov, L., Bhise, N. S., Manoharan, V., Dokmeci, M. R., & Khademhosseini, A. (2014) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2014.886562 · Cited by 223 · cited 1×
“Advances in microfabrication and polymer processing technologies have enabled the development of highly complex systems where a variety of cell types can be cocultured in a controlled environment, thereby establishing a new multidisciplinary scientific field known as organ on a chip [4–11].”
BackgroundBaker, M. (2011) · Nature · doi:10.1038/471661a · Cited by 188 · cited 1×
“Advances in microfabrication and polymer processing technologies have enabled the development of highly complex systems where a variety of cell types can be cocultured in a controlled environment, thereby establishing a new multidisciplinary scientific field known as organ on a chip [4–11].”
BackgroundIn vitro analysis of a hepatic device with intrinsic microvascular-based channels
Carraro, A., Hsu, W.-M., Kulig, K. M., Cheung, W. S., Miller, M. L., Weinberg, E. J., Swart, E. F., Kaazempur-Mofrad, M., Borenstein, J. T., Vacanti, J. P., et al. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9194-3 · Cited by 168 · cited 1×
“This has traditionally been accomplished by the creation of scaffolds, by embedding cells in 3D hydrogels [19,20], by means of nanoporous membranes [21], or by culturing them on grooved substrates [22].”
MethodApproaching the in vitro clinical trial: engineering organs on chips
Capulli, A. K., Tian, K., Mehandru, N., Bukhta, A., Choudhury, S. F., Suchyta, M., & Parker, K. K. (2014) · Lab on a Chip · doi:10.1039/c4lc00276h · Cited by 111
Cited by
Sinusoidal communication in liver fibrosis and regeneration
Marrone, G., Shah, V. H., & Gracia-Sancho, J. (2016) · Journal of Hepatology · doi:10.1016/j.jhep.2016.04.018 · Cited by 323
Self-citationMarx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Hepatic microcirculation and mechanisms of portal hypertension
Gracia-Sancho, J., Marrone, G., & Fernández-Iglesias, A. (2019) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-018-0097-3 · Cited by 274
Self-citationMarrone, G., Maeso-Díaz, R., García-Cardena, G., Abraldes, J. G., García-Pagán, J. C., Bosch, J., & Gracia-Sancho, J. (2015) · Gut · doi:10.1136/gutjnl-2014-308338 · Cited by 222
Self-citationFlat and microstructured polymeric membranes in organs-on-chips
Pasman, T., Grijpma, D., Stamatialis, D., & Poot, A. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2018.0351 · Cited by 98
Metadata
- Authors
- Illa, X., Vila, S., Yeste, J., Peralta, C., Gracia-Sancho, J., & Villa, R.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2014-11-06
- Volume
- 9
- Issue
- 11
- Pages
- e111864
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2079330060
- Cited by
- 36
- References
- 7
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Modular Bioreactor to In Vitro Study the Hepatic Sinusoid. https://app.cochat.ai/papers/10.1371/journal.pone.0111864
- The paper
- Illa, X., Vila, S., Yeste, J., Peralta, C., Gracia-Sancho, J., & Villa, R. (2014). A Novel Modular Bioreactor to In Vitro Study the Hepatic Sinusoid. PLoS ONE. https://doi.org/10.1371/journal.pone.0111864
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.