Adverse Events in Robotic Surgery: A Retrospective Study of 14 Years of FDA Data
Open accessThe DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Use of robotic systems for minimally invasive surgery has rapidly increased during the last decade. Understanding the causes of adverse events and their impact on patients in robot-assisted surgery will help improve systems and operational practices to avoid incidents in the future. METHODS: By developing an automated natural language processing tool, we performed a comprehensive analysis of the adverse events reported to the publicly available MAUDE database (maintained by the U.S. Food and Drug Administration) from 2000 to 2013. We determined the number of events reported per procedure and per surgical specialty, the most common types of device malfunctions and their impact on patients, and the potential causes for catastrophic events such as patient injuries and deaths. RESULTS: During the study period, 144 deaths (1.4% of the 10,624 reports), 1,391 patient injuries (13.1%), and 8,061 device malfunctions (75.9%) were reported. The numbers of injury and death events per procedure have stayed relatively constant (mean = 83.4, 95% confidence interval (CI), 74.2-92.7 per 100,000 procedures) over the years. Surgical specialties for which robots are extensively used, such as gynecology and urology, had lower numbers of injuries, deaths, and conversions per procedure than more complex surgeries, such as cardiothoracic and head and neck (106.3 vs. 232.9 per 100,000 procedures, Risk Ratio = 2.2, 95% CI, 1.9-2.6). Device and instrument malfunctions, such as falling of burnt/broken pieces of instruments into the patient (14.7%), electrical arcing of instruments (10.5%), unintended operation of instruments (8.6%), system errors (5%), and video/imaging problems (2.6%), constituted a major part of the reports. Device malfunctions impacted patients in terms of injuries or procedure interruptions. In 1,104 (10.4%) of all the events, the procedure was interrupted to restart the system (3.1%), to convert the procedure to non-robotic techniques (7.3%), or to reschedule it (2.5%). CONCLUSIONS: Despite widespread adoption of robotic systems for minimally invasive surgery in the U.S., a non-negligible number of technical difficulties and complications are still being experienced during procedures. Adoption of advanced techniques in design and operation of robotic surgical systems and enhanced mechanisms for adverse event reporting may reduce these preventable incidents in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

![Fig 2 Data extraction and analysis flow from the FDA MAUDE database. The dictionaries of keywords for surgery types/specialties and surgical instruments were constructed based on the online information available on the da Vinci surgeries [32] and instruments catalog [33] from the manufacturer. The analysis tool was developed using open-source Python libraries for natural language processing, data analysis, and machine learning.](https://figures.cochat.ai/paper-figures/52d4daa60f2347c8938ae62f07d16891/adverse-events-in-robotic-surgery-a-retrospective-study-of-14-years-of-fda-data-figure-2.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“On health care despite the known advantages of using robots in surgeries, medical robots were reported to have a negative impact on patients’ lives due to inaccuracy mistakes and errors [210], or due to cyber-attacks (i.e. data exposure/leakage) such as the case of North Korea-Unit 180 (Lazarus) attack on UK’s National Health Service (NHS) in 2017 [211, 212].”
From Robotics cyber security: vulnerabilities, attacks, countermeasures, and recommendations (2022) · cites this paper as [210]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foundations of statistical natural language processing
Manning, C. D., & Schütze, H. (1999) · Cited by 9,816
Corke, P., Roberts, J., Cunningham, J., & Hainsworth, D. (2008) · Springer Handbook of Robotics · doi:10.1007/978-3-540-30301-5_50 · Cited by 3,543
Sample Size Tables for Clinical Studies
Machin, D., Campbell, M. J., Tan, S. B., & Tan, S. H. (2008) · Wiley eBooks · doi:10.1002/9781444300710 · Cited by 1,336
New Technology and Health Care Costs — The Case of Robot-Assisted Surgery
Barbash, G. I., & Glied, S. A. (2010) · New England Journal of Medicine · doi:10.1056/nejmp1006602 · Cited by 993
Minimally invasive mitral valve surgery: a systematic review and meta-analysis
Modi, P., Hassan, A., & Chitwood, W. R. (2008) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2008.07.057 · Cited by 503
An open-source research kit for the da Vinci® Surgical System
Kazanzides, P., Chen, Z., Deguet, A., Fischer, G. S., Taylor, R. H., & DiMaio, S. P. (2014) · 2014 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2014.6907809 · Cited by 493
Raven-II: An Open Platform for Surgical Robotics Research
Hannaford, B., Rosen, J., Friedman, D. W., King, H., Roan, P., Cheng, L., Glozman, D., Ma, J., Kosari, S. N., & White, L. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2228858 · Cited by 372
Holzhey, D. M., Seeburger, J., Misfeld, M., Borger, M. A., & Mohr, F. W. (2013) · Circulation · doi:10.1161/circulationaha.112.001402 · Cited by 302
Hauser, R. G., Katsiyiannis, W. T., Gornick, C. C., Almquist, A. K., & Kallinen, L. M. (2010) · Europace · doi:10.1093/europace/eup375 · Cited by 264
The RAVEN: Design and Validation of a Telesurgery System
Lum, M. J. H., Friedman, D. C. W., Sankaranarayanan, G., King, H., Fodero, K., Leuschke, R., Hannaford, B., Rosen, J., & Sinanan, M. N. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909101795 · Cited by 264
Research works printed but not linked: 2
- Eichel L, Ahlering TE, Clayman RV. " Robotics in Urologic Surgery: Risks and Benefits." AUA Update Series 2005; 24(lesson 13): 106– 111.
- Alemzadeh Homa, et al " A Software Framework for Simulation of Safety Hazards in Robotic Surgical Systems," SIGBED Review (Special Issue on Medical Cyber Physical Systems Workshop) 12 4 (2015).
Cited by
Micro/nanorobots for biomedicine: Delivery, surgery, sensing, and detoxification
Li, J., Esteban-Fernández de Ávila, B., Gao, W., Zhang, L., & Wang, J. (2017) · Science Robotics · doi:10.1126/scirobotics.aam6431 · Cited by 1,565
“Despite widespread adoption of robotic systems for minimally invasive surgery, there are still major technical difficulties and challenges (4).”
BackgroundEthics and governance of trustworthy medical artificial intelligence
Zhang, J., & Zhang, Z.-M. (2023) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-023-02103-9 · Cited by 507
“Between 2000 and 2013, surgical robots in the United States were responsible for at least 1,391 harm-causing incidents and 144 deaths [48].”
BackgroundRobotics cyber security: vulnerabilities, attacks, countermeasures, and recommendations
Yaacoub, J.-P. A., Noura, H. N., Salman, O., & Chehab, A. (2022) · International Journal of Information Security · doi:10.1007/s10207-021-00545-8 · Cited by 320
Transparency, auditability, and explainability of machine learning models in credit scoring
Bücker, M., Szepannek, G., Gosiewska, A., & Biecek, P. (2022) · Journal of the Operational Research Society · doi:10.1080/01605682.2021.1922098 · Cited by 189
“Thirdly, there is a growing number of reported failures of complex predictive models in different domains in the recent past that can be traced back to a lack of proper model validation and model understanding (Alemzadeh et al. 2016; Wexler 2017; McGough 2018; O’Neil 2016).”
BackgroundLegal personality of robots, corporations, idols and chimpanzees: a quest for legitimacy
Solaiman, S. M. (2017) · Artificial Intelligence and Law · doi:10.1007/s10506-016-9192-3 · Cited by 221
On the safety of machine learning: Cyber-physical systems, decision sciences, and data products
Varshney, K. R., & Alemzadeh, H. (2017) · Big Data · doi:10.1089/big.2016.0051 · Cited by 211
“As one example in the medical devices domain, we have mined a large database of adverse events to obtain exactly uch characterizations [11].”
BackgroundMethodSelf-citationMinimally Invasive and Regenerative Therapeutics
Ashammakhi, N., Ahadian, S., Darabi, M. A., El Tahchi, M., Lee, J., Suthiwanich, K., Sheikhi, A., Dokmeci, M. R., Oklu, R., & Khademhosseini, A. (2019) · Advanced Materials · doi:10.1002/adma.201804041 · Cited by 190
Accelerating Surgical Robotics Research: A Review of 10 Years With the da Vinci Research Kit
D'Ettorre, C., Mariani, A., Stilli, A., Rodriguez y Baena, F., Valdastri, P., Deguet, A., Kazanzides, P., Taylor, R. H., Fischer, G. S., DiMaio, S. P., et al. (2021) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2021.3101646 · Cited by 160
“To date, the dVRK, together with the purely research focused RAVEN robot [7] are the only examples of open research platforms in surgical robotics that have been used across multiple research groups.”
Banerjee, S. S., Jha, S., Cyriac, J., Kalbarczyk, Z. T., & Iyer, R. K. (2018) · 2018 48th Annual IEEE/IFIP International Conference on Dependable Systems and Networks (DSN) · doi:10.1109/dsn.2018.00066 · Cited by 142
“Airplanes [39] and surgical robots [40] are safety-critical semi-autonomous systems that have seen ubiquitous deployment, as well as a significant body of work characterizing and improving their resilience.”
BackgroundSelf-citationA Cross-sectional Analysis of Adverse Events and Litigation for Injectable Fillers
Rayess, H. M., Svider, P. F., Hanba, C. J., Patel, V. S., DeJoseph, L. M., Carron, M. A., & Zuliani, G. F. (2017) · JAMA Facial Plastic Surgery · doi:10.1001/jamafacial.2017.1888 · Cited by 152
Robotics in Healthcare: A Survey
Silvera‐Tawil, D. (2024) · SN Computer Science · doi:10.1007/s42979-023-02551-0 · Cited by 185
“However, this success does not translate into MIS involving soft tissue manipulation, where robots have not delivered on its early promise, with studies divided on their overall benefits [180, 181].”
Fosch‐Villaronga, E., & Mahler, T. (2021) · Computer law & security review · doi:10.1016/j.clsr.2021.105528 · Cited by 145
Chen, I., Ghazi, A., Sridhar, A. N., Stoyanov, D. V., Slack, M. C., Kelly, J. D., & Collins, J. W. (2020) · World Journal of Urology · doi:10.1007/s00345-020-03467-7 · Cited by 128
“In the US between 2000 and 2013 10,624 adverse events related to robotic procedures were reported [2].”
BackgroundTonutti, M., Elson, D. S., Yang, G., Darzi, A. W., & Sodergren, M. H. (2016) · Postgraduate Medical Journal · doi:10.1136/postgradmedj-2016-134311 · Cited by 121
Simpler is better: Lifting interpretability-performance trade-off via automated feature engineering
Gosiewska, A., Kozak, A., & Biecek, P. (2021) · Decision Support Systems · doi:10.1016/j.dss.2021.113556 · Cited by 135
Collins, J. W., Levy, J. A., Stefanidis, D., Gallagher, A. G., Coleman, M., Cecil, T. D., Ericsson, A. K., Mottrie, A., Wiklund, P. N., Ahmed, K., et al. (2019) · European Urology · doi:10.1016/j.eururo.2018.12.044 · Cited by 107
Ethics of Artificial Intelligence: Case Studies and Options for Addressing Ethical Challenges
Stahl, B. C., Schroeder, D., & Rodrigues, R. (2023) · SpringerBriefs in Research and Innovation Governance · doi:10.1007/978-3-031-17040-9 · Cited by 82
Consumer resistance to service robots at the hotel front desk: A mixed-methods research
Wang, X., Zhang, Z., Huang, D., & Li, Z. (2023) · Tourism Management Perspectives · doi:10.1016/j.tmp.2023.101074 · Cited by 113
Targeted Attacks on Teleoperated Surgical Robots: Dynamic Model-Based Detection and Mitigation
Alemzadeh, H., Chen, D., Li, X., Kesavadas, T., Kalbarczyk, Z. T., & Iyer, R. K. (2016) · 2016 46th Annual IEEE/IFIP International Conference on Dependable Systems and Networks (DSN) · doi:10.1109/dsn.2016.43 · Cited by 88
“As discussed in [25], in several safety incidents reported to the U.”
BackgroundSelf-citationAugmented-reality integrated robotics in neurosurgery: are we there yet?
Madhavan, K., Kolcun, J. P. G., Chieng, L. O., & Wang, M. Y. (2017) · Neurosurgical FOCUS · doi:10.3171/2017.2.focus177 · Cited by 87
Human Factors Integration in Robotic Surgery
Catchpole, K., Cohen, T., Alfred, M. C., Lawton, S., Kanji, F. F., Shouhed, D., Nemeth, L. S., & Anger, J. T. (2022) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/00187208211068946 · Cited by 101
“The FDA MAUDE database from 2000 to 2013 identi fi ed 1391 patient injuries, 8061 device malfunctions, and 144 deaths related to RAS (Alemzadeh et al., 2016).”
BackgroundArtificial Intelligence in Cardiac Surgery: Transforming Outcomes and Shaping the Future
Leivaditis, V., Beltsios, E. T., Papatriantafyllou, A., Grapatsas, K., Mulita, F., Kontodimopoulos, N., Baikoussis, N. G., Tchabashvili, L., Tasios, K., Maroulis, I., et al. (2025) · Clinics and Practice · doi:10.3390/clinpract15010017 · Cited by 91
Fosch‐Villaronga, E., Khanna, P., Drukarch, H., & Custers, B. H. M. (2022) · International Journal of Social Robotics · doi:10.1007/s12369-022-00875-0 · Cited by 87
“Indeed, some long term studies report that out of all equipment related failures reported in surgical procedures, nearly 43% can be attributed to incorrect configuration and settings [1].”
BackgroundInfluentialWatrowski, R., Kostov, S. G., & Alkatout, İ. (2021) · Videosurgery and Other Miniinvasive Techniques · doi:10.5114/wiitm.2021.108800 · Cited by 85
“Despite technical developments, equipment malfunctions are not infrequent in RALS [164, 165].”
BackgroundMedical Robotics and Computer-Integrated Interventional Medicine
Taylor, R. H., Kazanzides, P., Fischer, G. S., & Simaan, N. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-816034-3.00019-5 · Cited by 72
Complications of Robotic Surgery
Jara, R. D., Guerron, A. D., & Portenier, D. D. (2020) · Surgical Clinics of North America · doi:10.1016/j.suc.2019.12.008 · Cited by 71
Evaluation status of current and emerging minimally invasive robotic surgical platforms
Boal, M. W. E., Girasole, C. G. D., Tesfai, F. M., Morrison, T. E. M., Higgs, S., Ahmad, J., Arezzo, A., & Francis, N. K. (2023) · Surgical Endoscopy · doi:10.1007/s00464-023-10554-4 · Cited by 70
“Along with this expansion there have been calls for reporting on safe implementation of novel platforms and standardisation of training and accreditation within robotics, due to concerns over errors and patient safety [13, 14].”
BackgroundAutomated Pick-Up of Suturing Needles for Robotic Surgical Assistance
D’Ettorre, C., Dwyer, G., Du, X., Chadebecq, F., Vasconcelos, F., Momi, E. D., & Stoyanov, D. V. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8461200 · Cited by 66
Kelkar, D. S., Borse, M., Godbole, G. P., Kurlekar, U., & Slack, M. C. (2020) · Surgical Endoscopy · doi:10.1007/s00464-020-08014-4 · Cited by 65
Requirements elicitation for robotic and computer-assisted minimally invasive surgery
Nakawala, H., Momi, E. D., Tzemanaki, A., Dogramadzi, S., Russo, A., Catellani, M., Bianchi, R., COBELLI, O. D., Sideridis, A., Papakostas, E., et al. (2019) · International Journal of Advanced Robotic Systems · doi:10.1177/1729881419865805 · Cited by 64
“This lack of market penetration may have been triggered by poor training programmes, excessive cost, need for reconfiguration of conventional surgical theatres as well as reported suboptimal results in some surgical areas.(4) The U.”
BackgroundResultFrom Illusion to Reality: A Brief History of Robotic Surgery
Marino, M. V., Shabat, G., Gulotta, G., & Komorowski, A. L. (2018) · Surgical Innovation · doi:10.1177/1553350618771417 · Cited by 64
“In 2013, a spike in the number of adverse events during robotic procedures led the FDA to perform a survey in order to verify if these events had truly increased, or whether the reports improved due to growing awareness of surgeons, or if they are a consequence of the massive use of the robotic system or of insufficie…”
Robot-assisted partial nephrectomy
Novara, G., Falce, S. L., Kungulli, A., Gandaglia, G., Ficarra, V., & Mottrie, A. (2016) · International Journal of Surgery · doi:10.1016/j.ijsu.2016.05.073 · Cited by 63
On Threat Modeling and Mitigation of Medical Cyber-Physical Systems
Almohri, H. M. J., Cheng, L., Yao, D. D., & Alemzadeh, H. (2017) · IEEE/ACM Conference on Connected Health: Applications, Systems and Engineering Technologies · doi:10.1109/chase.2017.69 · Cited by 68
Self-citationExpert Consensus Recommendations for Robotic Surgery Credentialing
Stefanidis, D., Huffman, E. M., Collins, J. W., Martino, M. A., Satava, R. M., & Levy, J. S. (2020) · Annals of Surgery · doi:10.1097/sla.0000000000004531 · Cited by 63
“4 Indeed, prior studies have suggested there may be an increased risk for patient complications during the introduction of new technology, including robotic surgery, though this remains to be identified in prospective trials.(5-7) To ensure safe surgical practice and safe introduction of new technologies, the Joint Co…”
BackgroundIntraoperative and postoperative outcomes of robot-assisted cholecystectomy: a systematic review
Shenoy, R. S., Mederos, M. A., Ye, L., Mak, S., Begashaw, M. M., Booth, M. S., Shekelle, P., Wilson, M., Gunnar, W., Maggard-Gibbons, M. A., et al. (2021) · Systematic Reviews · doi:10.1186/s13643-021-01673-x · Cited by 59
“Between 2012 and 2018, a large statewide collaborative described a more-than-10-fold increase in robot-assisted general surgery cases [3].”
BackgroundThe Future of Open Heart Surgery in the Era of Robotic and Minimal Surgical Interventions
Harky, A., Chaplin, G., Chan, J. S. K., Eriksen, P., MacCarthy‐Ofosu, B., Theologou, T., & Muir, A. D. (2019) · Heart Lung and Circulation · doi:10.1016/j.hlc.2019.05.170 · Cited by 57
Can technological advancements help to alleviate COVID-19 pandemic? a review
Thomas, M. J., Lal, V., Baby, A. K., Rabeeh, V. M., James, A., & Raj, A. K. (2021) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2021.103787 · Cited by 61
“The study showed that from 2000 to 2013, there had been 144 casualties, 1391 injuries, and 8061 device malfunctioning cases reported by the use of robots during surgeries [117].”
Healthcare Digitalisation and the Changing Nature of Work and Society
Sætra, H. S., & Fosch‐Villaronga, E. (2021) · Healthcare · doi:10.3390/healthcare9081007 · Cited by 68
“Broken or burnt robot pieces can fall into the patient, electric sparks may burn human tissue, and instruments may operate unintendedly; all of which may cause harm, including death [41].”
BackgroundInfluentialThe 100 most influential manuscripts in robotic surgery: a bibliometric analysis
Connelly, T. M., Malik, Z., Sehgal, R., Byrnes, G., Coffey, J. C., & Peirce, C. B. (2019) · Journal of Robotic Surgery · doi:10.1007/s11701-019-00956-9 · Cited by 61
Schuessler, Z., Stiles, A. S., & Mancuso, P. J. (2019) · Journal of Clinical Nursing · doi:10.1111/jocn.15053 · Cited by 52
Robot Accident Investigation: A Case Study in Responsible Robotics
Winfield, A. F. T., Winkle, K., Webb, H., Lyngs, U., Jirotka, M. D., & Macrae, C. (2020) · Springer eBooks · doi:10.1007/978-3-030-66494-7_6 · Cited by 48
Clinical evaluation of complete solo surgery with the “ViKY®” robotic laparoscope manipulator
Takahashi, M., Takahashi, M., NISHINARI, N., Matsuya, H., Tosha, T., Minagawa, Y., Shimooki, O., & Abe, T. (2016) · Surgical Endoscopy · doi:10.1007/s00464-016-5058-8 · Cited by 47
Kamel, M., Villena‐Vargas, J., Rahouma, M., Lee, B., Harrison, S. W., Stiles, B. M., Abdelrahman, A. M., Altorki, N. K., & Port, J. L. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezz111 · Cited by 47
Comprehensive training in robotic surgery
Brook, N. R., Dell’Oglio, P., Barod, R., Collins, J. W., & Mottrie, A. (2018) · Current Opinion in Urology · doi:10.1097/mou.0000000000000566 · Cited by 46
Kim, C., Chung, D. G., Hwang, M., Cheon, B., Kim, H., Kim, J., & Kwon, D. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2926953 · Cited by 46
Robot-assisted surgery in India: A SWOT analysis
Mavuduru, R. S., Bora, G., Narain, T. A., Sharma, A., Devana, S., Singh, S., & Mandal, A. (2020) · Indian Journal of Urology · doi:10.4103/iju.iju_220_19 · Cited by 46
“[11] Manufacturer and User facility Device Experience, which is an independent voluntary database for reporting robotic malfunction, is also plagued by a significant under-reporting and remains an imprecise tool for reporting such malfunction.[11]”
BackgroundCollins, J. W., Ghazi, A., Stoyanov, D. V., Hung, A. J., Coleman, M., Cecil, T. D., Ericsson, A. K., Anvari, M., Wang, Y., Beaulieu, Y., et al. (2020) · European Urology Open Science · doi:10.1016/j.euros.2020.09.005 · Cited by 43
“It is recognised that errors are more common early in the surgeons’ learning curve, and the combination of simultaneously learning about both technology and technique has inherent patient safety risks [7,8].”
BackgroundEndoscopic Image-Based Skill Assessment in Robot-Assisted Minimally Invasive Surgery
Lajkó, G., Elek, R. N., & Haidegger, T. P. (2021) · Sensors · doi:10.3390/s21165412 · Cited by 48
“6% of the cases do adverse events occur [15], 75.”
BackgroundKim, S. S., Schumacher, L., Cooke, D. T., Servais, E. L., Rice, D., Sarkaria, I. S., Yang, S. S., Abbas, A., Sancheti, M. S., Long, J., et al. (2024) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2024.12.003 · Cited by 42
Robot-Assisted Minimally Invasive Surgical Skill Assessment—Manual and Automated Platforms
Elek, R. N., & Haidegger, T. P. (2019) · Acta Polytechnica Hungarica · doi:10.12700/aph.16.8.2019.8.9 · Cited by 55
A human in the loop in surgery automation
Fosch‐Villaronga, E., Khanna, P., Drukarch, H., & Custers, B. H. M. (2021) · Nature Machine Intelligence · doi:10.1038/s42256-021-00349-4 · Cited by 50
Adam, K., Mohamed, I. I., & Ibrahim, Y. (2021) · IEEE Access · doi:10.1109/access.2021.3076716 · Cited by 49
“This is mainly because even small errors might lead to serious injury or death, as reported by the Food and Drug Administration (FDA) department [14].”
BackgroundSystems-Theoretic Safety Assessment of Robotic Telesurgical Systems
Alemzadeh, H., Chen, D., Lewis, A. J., Kalbarczyk, Z., Raman, J., Leveson, N. G., & Iyer, R. K. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24255-2_16 · Cited by 48
“015: Authors. or reschedule it to a later date (24.8%). (Note that these categories are not mutually exclusive. In some cases after several system resets, the procedure was converted or rescheduled.) [2]. This data shows the importance of designing robust safety features in robotic surgical systems and verifying the e…”
BackgroundInfluentialSelf-citationRobot-assisted cholecystectomy is a safe but costly approach: A national database review
Pokala, B., Flores, L. E., Armijo, P. R., Kothari, V. M., & Oleynikov, D. (2019) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2019.08.014 · Cited by 40
On Healthcare Robots: Concepts, definitions, and considerations for healthcare robot governancePreprint
Fosch‐Villaronga, E., & Drukarch, H. (2021) · Leiden Repository (Leiden University) · doi:10.48550/arxiv.2106.03468 · Cited by 45
“To prevent or, at least, reduce such preventable incidents in the future, advanced techniques in the design and operation of robotic surgical systems and enhanced mechanisms for adverse event reporting ought to be adopted (Alemzadeh et al., 2016).”
BackgroundInfluentialReal-Time Context-Aware Detection of Unsafe Events in Robot-Assisted Surgery
Yasar, M. S., & Alemzadeh, H. (2020) · International Conference on Dependable Systems & Networks/Proceedings · doi:10.1109/dsn48063.2020.00054 · Cited by 44
Self-citationArtificial intelligence enabled healthcare: A hype, hope or harm
Bhattacharya, S., Pradhan, K. B., Bashar, M., Tripathi, S., Semwal, J., Marzo, R. R., Bhattacharya, S., & Singh, A. (2019) · Journal of Family Medicine and Primary Care · doi:10.4103/jfmpc.jfmpc_155_19 · Cited by 43
Ethical Dilemmas of Using Artificial Intelligence in Medicine
Astărăstoae, V., Rogozea, L. M., Leaşu, F., & Ioan, B. G. (2024) · American Journal of Therapeutics · doi:10.1097/mjt.0000000000001693 · Cited by 43
“63 The errors produced were caused by the software component and hardware defects, some of which were recognized and documented by important bodies, such as the U.S. Food and Drug Administration, which in 2019, discovered serious software errors in the ROSA Brain 3.0 robotic surgical system.”
InfluentialMultimodal Sensorimotor Integration for Expert-in-the-Loop Telerobotic Surgical Training
Shahbazi, M., Atashzar, S. F., Ward, C., Talebi, H. A., & Patel, R. V. (2018) · IEEE Transactions on Robotics · doi:10.1109/tro.2018.2861916 · Cited by 37
“There have been several RAMIS-related adverse events reported to the FDA during the past 15 years [7].”
BackgroundLaser Controlled 65 Micrometer Long Microrobot Made of Ni‐Ti Shape Memory Alloy
Kim, M., Lee, H., & Ahn, S. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900583 · Cited by 37
Kelkar, D. S., Kurlekar, U., Stevens, L., Wagholikar, G. D., & Slack, M. (2022) · Annals of Surgery · doi:10.1097/sla.0000000000005410 · Cited by 37
Regulating safety-critical autonomous systems: past, present, and future perspectives
Cummings, M. L., & Britton, D. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815367-3.00006-2 · Cited by 36
Autonomous surgery in the era of robotic urology: friend or foe of the future surgeon?
Connor, M. J., Prokar Dasgupta, A., Ahmed, H. U., & Raza, A. (2020) · Nature Reviews Urology · doi:10.1038/s41585-020-0375-z · Cited by 36
Adverse Events Associated With Aesthetic Dermal Fillers: A 10-Year Retrospective Study of FDA Data
Povolotskiy, R., Oleck, N. C., Hatzis, C. M., & Paskhover, B. (2018) · The American Journal of Cosmetic Surgery · doi:10.1177/0748806818757123 · Cited by 35
Do Not Trust Additive Explanations
Gosiewska, A., & Biecek, P. (2019) · arXiv · doi:10.48550/arxiv.1903.11420 · Cited by 34
“The list of such cases range from accidents while using surgical robots that cause minor injuries to patients (Alemzadeh et al., 2016) to problems with automated criminal justice technologies (Wexler, 2017) or incorrect predictions of air quality (McGough, 2018).”
BackgroundPuliatti, S., Mazzone, E., Amato, M., GROOTE, R. D., Mottrie, A., & Gallagher, A. G. (2020) · Surgical Endoscopy · doi:10.1007/s00464-020-07918-5 · Cited by 34
Chang, T. P., Chok, A. Y., Tan, D. T. M., Rogers, A. C., Rasheed, S., Tekkis, P. P., & Kontovounisios, C. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10071518 · Cited by 34
“75 million robotic procedures have been performed since 2003, there are low but nonnegligible numbers of technical difficulties and complications still being experienced during procedures [25].”
BackgroundPower, D. (2024) · Discover Artificial Intelligence · doi:10.1007/s44163-024-00166-9 · Cited by 32
Evaluation of current and emerging endoluminal robotic platforms using the IDEAL framework
Shah, D., Tesfai, F. M., Boal, M. W. E., Arezzo, A., & Francis, N. K. (2025) · Minimally Invasive Therapy & Allied Technologies · doi:10.1080/13645706.2025.2467805 · Cited by 32
“Key factors affecting the adoption of technologies include costs (initial and maintenance), lack of standardisation in training, limited clinical evidence to confirm patient safety [53,54], and lack of availability of national guidance on this matter [55].”
Borza, T., Jacobs, B. L., Montgomery, J. S., Weizer, A. Z., Morgan, T. M., Hafez, K. S., Lee, C. T., Li, B. Y., Min, H. S., He, C., et al. (2017) · Urology · doi:10.1016/j.urology.2017.01.042 · Cited by 32
“, due to positioning, out-of-field injury).(14) In addition, even though both approaches could lead to the same complication, the severity of the complication, and thus the burden of the readmission, could vary substantially.”
An interpretable automated feature engineering framework for improving logistic regression
Liu, M., Guo, C., & Xu, L. (2024) · Applied Soft Computing · doi:10.1016/j.asoc.2024.111269 · Cited by 36
Evaluation of contactless human–machine interface for robotic surgical training
Despinoy, F., Zemiti, N., Forestier, G., Sánchez, A., Jannin, P., & Poignet, P. (2017) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-017-1666-6 · Cited by 31
“, patient damaging, longer recovery period) which are sometimes underestimated [2, 4].”
BackgroundWu, C. Z., Klebanoff, J. S., Tyan, P., & Moawad, G. (2019) · Journal of Robotic Surgery · doi:10.1007/s11701-019-00948-9 · Cited by 31
An eye-tracking based robotic scrub nurse: proof of concept
Ezzat, A., Kogkas, A., Holt, J., Thakkar, R., Darzi, A. W., & Mylonas, G. P. (2021) · Surgical Endoscopy · doi:10.1007/s00464-021-08569-w · Cited by 31
“5 million laparoscopic surgeries, demonstrating reduced post-operative pain, hospital stay and improved surgical accessibility and view in confined anatomical spaces [2].”
BackgroundClassification Schemas for Artificial Intelligence Failures
Scott, P. J. H., & Yampolskiy, R. V. (2019) · Delphi - Interdisciplinary Review of Emerging Technologies · doi:10.21552/delphi/2019/4/8 · Cited by 37
Zhou, X., Chen, Y., Miao, G., Guo, Y., Zhang, Q., & Bi, J. (2024) · iScience · doi:10.1016/j.isci.2024.111509 · Cited by 29
Supervised Autonomous Electrosurgery via Biocompatible Near-Infrared Tissue Tracking Techniques
Saeidi, H., Ge, J., Kam, M., Opfermann, J. D., Léonard, S., Joshi, A. S., & Krieger, A. (2019) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2019.2949870 · Cited by 39
“Digital Object Identifier 10.1109/TMRB.2019.2949870 I. INTRODUCTION CONSIDERABLE advances in robotic and camera tech-nology [1], have led to a total of approximately 1.75 million robotic surgeries by 2016 in the United States [2].”
BackgroundInfluentialDeveloping a Robotic Surgery Curriculum: Selection of Virtual Reality Drills for Content Alignment
Alterio, R. E., Nagaraj, M. B., Scott, D. J., Tellez, J. C., Radi, I., Baker, H. B., Zeh, H. J., & Polanco, P. M. (2022) · Journal of Surgical Research · doi:10.1016/j.jss.2022.11.019 · Cited by 27
Implementing Ai Principles: Frameworks, Processes, and ToolsPreprint
Boza, P., & Evgeniou, T. (2021) · SSRN Electronic Journal · doi:10.2139/ssrn.3783124 · Cited by 36
Robotische Chirurgie – operiert der Roboter?
Schuler, P. J. (2018) · Laryngo-Rhino-Otologie · doi:10.1055/s-0043-121791 · Cited by 28
“[3] Alemzadeh H, Raman J, Leveson N et al.”
BackgroundEthical Considerations for Generative Artificial Intelligence in Plastic Surgery
Dhawan, R., Brooks, K. D., Shauly, O., Shay, D., & Losken, A. (2025) · Plastic & Reconstructive Surgery Global Open · doi:10.1097/gox.0000000000006825 · Cited by 29
“70 For example, the adoption of robotic-assisted tools for minimally invasive procedures, though seemingly infallible, has a nonzero number of adverse events 71 and was initially met with considerable skepticism and underwent decades of review before approval.”
Correa, J., Aribo, C., Stuparich, M. A., Nahas, S., Cheung, C. S.-S., & Behbehani, S. (2021) · Journal of Minimally Invasive Gynecology · doi:10.1016/j.jmig.2021.08.021 · Cited by 26
Artificial intelligence, human intelligence, and the future of public health
Bhattacharya, S. (2022) · AIMS Public Health · doi:10.3934/publichealth.2022045 · Cited by 26
Criminal risks of medical robots turnover
Shutova, А. A. (2023) · Актуальные проблемы экономики и права · doi:10.21202/2782-2923.2023.3.571-585 · Cited by 25
He, B., de Smet, M. D., Sodhi, M., Etminan, M., & Maberley, D. (2021) · Eye · doi:10.1038/s41433-021-01599-7 · Cited by 25
Ludvigsen, K. R., & Nagaraja, S. (2022) · Computer law & security review · doi:10.1016/j.clsr.2022.105656 · Cited by 28
Neurointerventional Robotics: Challenges and Opportunities
Goyal, M., Sutherland, G. R., Lama, S., Cimflová, P., Kashani, N., Mayank, A., Psychogios, M., Spelle, L., Costalat, V., Sakai, N., et al. (2020) · Clinical Neuroradiology · doi:10.1007/s00062-020-00913-2 · Cited by 25
Investment and quality competition in healthcare markets
Ghandour, Z., Siciliani, L., & Straume, O. R. (2022) · Journal of Health Economics · doi:10.1016/j.jhealeco.2022.102588 · Cited by 27
Analysis of executional and procedural errors in dry‐lab robotic surgery experiments
Hutchinson, K., Li, Z., Cantrell, L. A., Schenkman, N. S., & Alemzadeh, H. (2022) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.2375 · Cited by 24
“2 Methods Sources of errors in RAS are diverse and domain-specific, including faults in the robotic system software and hardware, or human errors [2].”
BackgroundSelf-citationConversions in pediatric robot-assisted laparoscopic surgery
Cundy, T. P., Fabrizio, D. D., Alizai, N. K., & Najmaldin, A. (2021) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2021.10.056 · Cited by 24
A comparison of outcomes between laparoscopic and robotic appendectomy among ACS-NSQIP hospitals
Becker, T., DeLeon, G., Rao, V., & Pei, K. Y. (2023) · Laparoscopic Endoscopic and Robotic Surgery · doi:10.1016/j.lers.2023.04.003 · Cited by 24
Liu, T., Wang, J., Wong, S. W., Razjigaev, A., Beier, S., Peng, S., Do, T. N., Song, S., Chu, D., Wang, C., et al. (2024) · Advanced Intelligent Systems · doi:10.1002/aisy.202400197 · Cited by 27
Verma, N., Kumar, N., Verma, C., Illés, Z., & Singh, D. (2025) · International Journal of Information Security · doi:10.1007/s10207-025-01041-z · Cited by 26
“The study conducted by [77] on data analysis pertaining to patient safety-related incidents, including deaths, injuries, and device malfunctions such as system errors, video/imaging problems, uncontrolled instrument movements, and spontaneous powering on/off, highlights the necessity of enhancing…”
Nik‐Ahd, F., Souders, C., Houman, J., Zhao, H. H., Chughtai, B. I., & Anger, J. T. (2019) · Journal of Endourology · doi:10.1089/end.2018.0802 · Cited by 23
Cai, Y., Choi, P., Hui, C.-W. V., Taylor, R. H., & Au, K. W. S. (2021) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2021.3058174 · Cited by 23
Design and Implementation of an Emergency Undocking Curriculum for Robotic Surgery
Melnyk, R., Saba, P., Holler, T., Cameron, K., Mithal, P., Rappold, P., Wu, G., Cubillos, J., Rashid, H., Joseph, J. V., et al. (2021) · Simulation in Healthcare The Journal of the Society for Simulation in Healthcare · doi:10.1097/sih.0000000000000596 · Cited by 24
“Our review identified that with the widespread adoption of robotic systems for minimally invasive surgery in the United States, a nonnegligible number of technical difficulties and complications are experienced.(4) More than 75% of 10,624 reported adverse events were due to device and instrument malfunctions, resultin…”
BackgroundInfluentialAutonomous Nanorobots as Miniaturized Surgeons for Intracellular Applications
Tang, D., Peng, X., Wu, S., & Tang, S. (2024) · Nanomaterials · doi:10.3390/nano14070595 · Cited by 28
“His ideas of ‘swallowing the surgeon’ inspired the development of tiny surgical robots designed to be ingested [1,2].”
BackgroundTakács, K., Lukács, E., Levendovics, R., Pekli, D., Szíjártó, A., & Haidegger, T. P. (2024) · Sensors · doi:10.3390/s24092915 · Cited by 25
“Computer-integrated surgery has seen significant technical challenges on the top of the clinical complications [15,16].”
BackgroundTexture differentiation using audio signal analysis with robotic interventional instruments
Chen, C. H., Sühn, T., Kalmar, M., Maldonado, I., Wex, C. B. A., Croner, R. S., Boese, A., Friebe, M., & Manríquez, A. I. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103370 · Cited by 23
Advanced diagnostic and therapeutic strategies in nanotechnology for lung cancer
Duan, Y., Shen, C., Zhang, Y., & Luo, Y. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.1031000 · Cited by 24
Metadata
- Authors
- Alemzadeh, H., Raman, J., Leveson, N., Kalbarczyk, Z., & Iyer, R. K.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Massachusetts Institute of Technology (US)
- Corresponding author
- Alemzadeh, Homa
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2016-04-20
- Volume
- 11
- Issue
- 4
- Pages
- e0151470
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC4838256
- OpenAlex
- W1720752806
- Cited by
- 441
- References
- 53
- Citations by year
- 2026: 51 · 2025: 51 · 2024: 51 · 2023: 31 · 2022: 36 · 2021: 69 · 2020: 34 · 2019: 50 · 2018: 33 · 2017: 22 · 2016: 10
- FWCI
- 66.22
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc-sa)
- Figshare (submittedVersion, cc-by)
- arXiv (Cornell University)
- Funders
- National Science Foundation (1314891, 1545069)
- Society of Thoracic Surgeons
- University of Illinois at Urbana-Champaign
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Pharmacovigilance and Adverse Drug Reactions
- Social Sciences › Law › Medical Malpractice and Liability Issues
- Keywords
- robotic surgery, adverse events, equipment failure, patient harm, MAUDE database, natural language processing, conversion to open surgery, surgical specialties, minimally invasive surgery, patient safety, FDA adverse event reports, cardiothoracic surgery, head and neck surgery
- MeSH terms
- Equipment Failure, Humans, Laparoscopy, Retrospective Studies, Robotics, United States, United States Food and Drug Administration, Databases, Factual
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.