A Reversibly Sealed, Easy Access, Modular (SEAM) Microfluidic Architecture to Establish In Vitro Tissue Interfaces
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Microfluidic barrier tissue models have emerged as advanced in vitro tools to explore interactions with external stimuli such as drug candidates, pathogens, or toxins. However, the procedures required to establish and maintain these systems can be challenging to implement for end users, particularly those without significant in-house engineering expertise. Here we present a module-based approach that provides an easy-to-use workflow to establish, maintain, and analyze microscale tissue constructs. Our approach begins with a removable culture insert that is magnetically coupled, decoupled, and transferred between standalone, prefabricated microfluidic modules for simplified cell seeding, culture, and downstream analysis. The modular approach allows several options for perfusion including standard syringe pumps or integration with a self-contained gravity-fed module for simple cell maintenance. As proof of concept, we establish a culture of primary human microvascular endothelial cells (HMVEC) and report combined surface protein imaging and gene expression after controlled apical stimulation with the bacterial endotoxin lipopolysaccharide (LPS). We also demonstrate the feasibility of incorporating hydrated biomaterial interfaces into the microfluidic architecture by integrating an ultra-thin (< 1 μm), self-assembled hyaluronic acid/peptide amphiphile culture membrane with brain-specific Young's modulus (~ 1kPa). To highlight the importance of including biomimetic interfaces into microscale models we report multi-tiered readouts from primary rat cortical cells cultured on the self-assembled membrane and compare a panel of mRNA targets with primary brain tissue signatures. We anticipate that the modular approach and simplified operational workflows presented here will enable a wide range of research groups to incorporate microfluidic barrier tissue models into their work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Myotubes differentiate optimally on substrates with tissue-like stiffness
Engler, A. J., Griffin, M. A., Sen, S., Bönnemann, C. G., Sweeney, H. L., & Discher, D. E. (2004) · The Journal of Cell Biology · doi:10.1083/jcb.200405004 · Cited by 1,743
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Extracellular matrix as a biological scaffold material: Structure and function
BADYLAK, S., FREYTES, D., & GILBERT, T. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.09.013 · Cited by 1,671
Microfabrication of human organs-on-chips
Huh, D., Kim, H. J., Fraser, J. P., Shea, D. E., Khan, M., Bahinski, A., Hamilton, G. A., & Ingber, D. E. (2013) · Nature Protocols · doi:10.1038/nprot.2013.137 · Cited by 712 · cited 1×
“For example, a typical microfluidic system is seeded with ~ 20,000 primary human cells on one side of the membrane [58].”
BackgroundRuoslahti, E. (1996) · Glycobiology · doi:10.1093/glycob/6.5.489 · Cited by 467
Biomimetic tissues on a chip for drug discovery
Ghaemmaghami, A. M., Hancock, M. J., Harrington, H., Kaji, H., & Khademhosseini, A. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.029 · Cited by 359 · cited 1×
“Microfluidic barrier tissues (MBTs) are advanced in vitro culture models that combine microengineering techniques with living cells to help address the need for biologically representative assays to explore complex biological interactions [1,2].”
BackgroundMulti-cellular 3D human primary liver cell culture elevates metabolic activity under fluidic flow
Esch, M. B., Prot, J.-M., Wang, Y. I., Miller, P., Llamas-Vidales, J. R., Naughton, B. A., Applegate, D. R., & Shuler, M. L. (2015) · Lab on a Chip · doi:10.1039/c5lc00237k · Cited by 173
Cited by
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Wang, X., Sun, Q., & Pei, J. (2018) · Micromachines · doi:10.3390/mi9100493 · Cited by 106
Flat and microstructured polymeric membranes in organs-on-chips
Pasman, T., Grijpma, D., Stamatialis, D., & Poot, A. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2018.0351 · Cited by 98
Basement membrane properties and their recapitulation in organ-on-chip applications
Salimbeigi, G., Vrana, N. E., Ghaemmaghami, A. M., Huri, P. Y., & McGuinness, G. B. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2022.100301 · Cited by 57
Engineering fiber anisotropy within natural collagen hydrogels
Ahmed, A., Joshi, I. M., Mansouri, M., Ahamed, N. N. N., Hsu, M.-C., Gaborski, T. R., & Abhyankar, V. V. (2021) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00036.2021 · Cited by 41
Self-citation
Metadata
- Authors
- Abhyankar, V. V., Wu, M., Koh, C.-Y., & Hatch, A. V.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2016-05-26
- Volume
- 11
- Issue
- 5
- Pages
- e0156341
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2398055718
- Cited by
- 46
- References
- 8
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Reversibly Sealed, Easy Access, Modular (SEAM) Microfluidic Architecture to Establish In Vitro Tissue Interfaces. https://app.cochat.ai/papers/10.1371/journal.pone.0156341
- The paper
- Abhyankar, V. V., Wu, M., Koh, C.-Y., & Hatch, A. V. (2016). A Reversibly Sealed, Easy Access, Modular (SEAM) Microfluidic Architecture to Establish In Vitro Tissue Interfaces. PLOS ONE. https://doi.org/10.1371/journal.pone.0156341
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.