Human perception of electrical stimulation on the surface of somatosensory cortex

Open access

Abstract

Recent advancement in electrocorticography (ECoG)-based brain-computer interface technology has sparked a new interest in providing somatosensory feedback using ECoG electrodes, i.e., cortical surface electrodes. We conducted a 28-day study of cortical surface stimulation in an individual with arm paralysis due to brachial plexus injury to examine the sensation produced by electrical stimulation of the somatosensory cortex. A high-density ECoG grid was implanted over the somatosensory and motor cortices. Stimulation through cortical surface electrodes over the somatosensory cortex successfully elicited arm and hand sensations in our participant with chronic paralysis. There were three key findings. First, the intensity of perceived sensation increased monotonically with both pulse amplitude and pulse frequency. Second, changing pulse width changed the type of sensation based on qualitative description provided by the human participant. Third, the participant could distinguish between stimulation applied to two neighboring cortical surface electrodes, 4.5 mm center-to-center distance, for three out of seven electrode pairs tested. Taken together, we found that it was possible to modulate sensation intensity, sensation type, and evoke sensations across a range of locations from the fingers to the upper arm using different stimulation electrodes even in an individual with chronic impairment of somatosensory function. These three features are essential to provide effective somatosensory feedback for neuroprosthetic applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0176020

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 ECoG grid and activation thresholds. A: Photograph of the high-density ECoG grid used in this study. The camera is looking at the back of the grid, the non-brain facing surface. The grid was composed of a silicone sheet (4 cm × 4 cm in size, 1 mm thick) with 64 platinum electrodes. The electrodes were 2 mm in diameter and 4.5 mm apart (center-to-center), except for the two ground electrodes that were 3 mm in diameter and 5 mm from the neighboring electrodes (center-to-center). All electrodes were connected to platinum lead wires that formed four 60-cm long leads. B: Post-operative skull radiograph showing the ECoG grid. C: Grid location on brain surface. The blue electrodes are above the motor cortex (M1). The yellow electrodes are above the somatosensory cortex (S1). The green and grey electrodes are dura-facing ground and reference electrodes, respectively. The white electrodes did not generate a response to any cortical stimulation attempted within the safety limits of our study (less than 57 μC/cm2 per phase). D: Activation thresholds. G1 and G2 (black electrodes) were the return electrodes for Electrodes 1–32 and Electrodes 33–64, respectively. The threshold values are presented in terms of charge exchange per second (μC•Hz) required to elicit a response. The gray line separates the electrodes above the motor and somatosensory cortices. The stimulation pulse amplitude, width, and frequency ranged from 1 to 7 mA, 50 to 400 μs, and 50 to 500 Hz, respectively. The color bar represents the range of the charge exchange.
Fig 1 ECoG grid and activation thresholds. A: Photograph of the high-density ECoG grid used in this study. The camera is looking at the back of the grid, the non-brain facing surface. The grid was composed of a silicone sheet (4 cm × 4 cm in size, 1 mm thick) with 64 platinum electrodes. The electrodes were 2 mm in diameter and 4.5 mm apart (center-to-center), except for the two ground electrodes that were 3 mm in diameter and 5 mm from the neighboring electrodes (center-to-center). All electrodes were connected to platinum lead wires that formed four 60-cm long leads. B: Post-operative skull radiograph showing the ECoG grid. C: Grid location on brain surface. The blue electrodes are above the motor cortex (M1). The yellow electrodes are above the somatosensory cortex (S1). The green and grey electrodes are dura-facing ground and reference electrodes, respectively. The white electrodes did not generate a response to any cortical stimulation attempted within the safety limits of our study (less than 57 μC/cm2 per phase). D: Activation thresholds. G1 and G2 (black electrodes) were the return electrodes for Electrodes 1–32 and Electrodes 33–64, respectively. The threshold values are presented in terms of charge exchange per second (μC•Hz) required to elicit a response. The gray line separates the electrodes above the motor and somatosensory cortices. The stimulation pulse amplitude, width, and frequency ranged from 1 to 7 mA, 50 to 400 μs, and 50 to 500 Hz, respectively. The color bar represents the range of the charge exchange.CC0 · PubMed Central
Fig 2 Stimulation paradigms. A stimulus train is a group of bi-phasic pulses drawn in red. This figure is not drawn to actual time scale.
Fig 2 Stimulation paradigms. A stimulus train is a group of bi-phasic pulses drawn in red. This figure is not drawn to actual time scale.CC0 · PubMed Central
Fig 3 Motor and somatosensory cortical electrode activation thresholds and electrode impedances. A: Median and interquartile range of activation thresholds for electrodes above the somatosensory cortex (light gray) and those above the motor cortex (dark gray). Activation thresholds were significantly different between the somatosensory and motor cortical electrodes (Wilcoxon rank sum test, p<0.05). B: Median and interquartile range of impedances for electrodes above the somatosensory cortex (light gray) and those above the motor cortex (dark gray). Electrode impedances were tested at the end of the implantation surgery using the clinical XLTEK® system (non-programmable default testing signal frequency of 1000 Hz). There was no significant difference in electrode impedance between the somatosensory and motor cortical electrodes (Wilcoxon rank sum test, p = 0.66).
Fig 3 Motor and somatosensory cortical electrode activation thresholds and electrode impedances. A: Median and interquartile range of activation thresholds for electrodes above the somatosensory cortex (light gray) and those above the motor cortex (dark gray). Activation thresholds were significantly different between the somatosensory and motor cortical electrodes (Wilcoxon rank sum test, p<0.05). B: Median and interquartile range of impedances for electrodes above the somatosensory cortex (light gray) and those above the motor cortex (dark gray). Electrode impedances were tested at the end of the implantation surgery using the clinical XLTEK® system (non-programmable default testing signal frequency of 1000 Hz). There was no significant difference in electrode impedance between the somatosensory and motor cortical electrodes (Wilcoxon rank sum test, p = 0.66).CC0 · PubMed Central
Fig 4 Sensation fields perceived by the participant. A: Electrode groups that correspond to the eight patterns of evoked sensations indicated by the participant. The white electrodes had no response to cortical stimulation. B: The eight patterns of activity, corresponding to various sensation fields, perceived by the participant during stimulation of the sensory electrodes. The sketches were made by the participant using his right hand on a template.
Fig 4 Sensation fields perceived by the participant. A: Electrode groups that correspond to the eight patterns of evoked sensations indicated by the participant. The white electrodes had no response to cortical stimulation. B: The eight patterns of activity, corresponding to various sensation fields, perceived by the participant during stimulation of the sensory electrodes. The sketches were made by the participant using his right hand on a template.CC0 · PubMed Central
Fig 5 Perceived intensity as a function of stimulation pulse amplitude and frequency. The figures indicate the percentage of perceived intensity (y-axis) for a second stimulus train with respect to a preceding reference stimulus train. All trials consisted of two stimulus trains separated by a 2 s time gap. The x-axis indicates the pulse amplitude or frequency. The reference pulse amplitude and frequency are marked by black arrows. The black dots and error bars represent mean and 95% confidence interval, and the linear fit was drawn as a black line. A: The figure corresponds to 10 repetitions of stimulations at Electrode 38 (Linear fit: R2 = 0.99, p< 0.05). A similar monotonic pattern was observed with three other electrodes (3, 11, and 20). B: The figure corresponds to 3 repetitions of stimulations at Electrode 38 (Linear fit: R2 = 0.48, p< 0.05). A similar pattern was observed with three other electrodes (3, 20, and 46). C: Perceived intensity reported by the participant for a smaller frequency range (100 to 200 Hz) compared to B. The figure corresponds to 10 repetitions of stimulations at Electrode 38 (Linear fit: R2 = 0.71, p< 0.05). A similar pattern was observed with three other electrodes (3, 20, and 46).
Fig 5 Perceived intensity as a function of stimulation pulse amplitude and frequency. The figures indicate the percentage of perceived intensity (y-axis) for a second stimulus train with respect to a preceding reference stimulus train. All trials consisted of two stimulus trains separated by a 2 s time gap. The x-axis indicates the pulse amplitude or frequency. The reference pulse amplitude and frequency are marked by black arrows. The black dots and error bars represent mean and 95% confidence interval, and the linear fit was drawn as a black line. A: The figure corresponds to 10 repetitions of stimulations at Electrode 38 (Linear fit: R2 = 0.99, p< 0.05). A similar monotonic pattern was observed with three other electrodes (3, 11, and 20). B: The figure corresponds to 3 repetitions of stimulations at Electrode 38 (Linear fit: R2 = 0.48, p< 0.05). A similar pattern was observed with three other electrodes (3, 20, and 46). C: Perceived intensity reported by the participant for a smaller frequency range (100 to 200 Hz) compared to B. The figure corresponds to 10 repetitions of stimulations at Electrode 38 (Linear fit: R2 = 0.71, p< 0.05). A similar pattern was observed with three other electrodes (3, 20, and 46).CC0 · PubMed Central
Fig 6 Perceived sensation for two types of stimulus trains. The two types of stimulus trains were 0.5 s in duration and had pulse widths of 200 μs and 400 μs. The participant reported two distinct sensations (tingling and electrical buzz) for four of the eight electrodes (20: 100%. 38: 90%. 39: 90%. 46: 90%) when the stimulus train pulse width was changed from 400 μs (10 repetitions) to 200 μs (10 repetitions). The sensation types of tingling, electrical buzz (E. Buzz), vibration, and vertigo are indicated by yellow, cyan, green, and blue colored tiles, respectively. The white colored tiles indicate no perceived sensation.
Fig 6 Perceived sensation for two types of stimulus trains. The two types of stimulus trains were 0.5 s in duration and had pulse widths of 200 μs and 400 μs. The participant reported two distinct sensations (tingling and electrical buzz) for four of the eight electrodes (20: 100%. 38: 90%. 39: 90%. 46: 90%) when the stimulus train pulse width was changed from 400 μs (10 repetitions) to 200 μs (10 repetitions). The sensation types of tingling, electrical buzz (E. Buzz), vibration, and vertigo are indicated by yellow, cyan, green, and blue colored tiles, respectively. The white colored tiles indicate no perceived sensation.CC0 · PubMed Central
Fig 7 Spatial discrimination for cortical stimulation. ECoG grid showing the pairs of electrodes that were tested for spatial discrimination and their corresponding perceived body parts indicated by colored outlines. The pulse width, pulse frequency, and stimulus train duration were 400 μs, 500 Hz, and 0.5 s, respectively. The pulse amplitude for Electrodes 3, 11, 19, 12, 20, 38, 39, and 46 were 2.5 mA, 1.5 mA, 1.5 mA, 2 mA, 1.5 mA, 2.5 mA, 2 mA, and 2 mA, respectively.
Fig 7 Spatial discrimination for cortical stimulation. ECoG grid showing the pairs of electrodes that were tested for spatial discrimination and their corresponding perceived body parts indicated by colored outlines. The pulse width, pulse frequency, and stimulus train duration were 400 μs, 500 Hz, and 0.5 s, respectively. The pulse amplitude for Electrodes 3, 11, 19, 12, 20, 38, 39, and 46 were 2.5 mA, 1.5 mA, 1.5 mA, 2 mA, 1.5 mA, 2.5 mA, 2 mA, and 2 mA, respectively.CC0 · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 124

Metadata

Authors
Hiremath, S. V., Tyler-Kabara, E. C., Wheeler, J. J., Moran, D. W., Gaunt, R. A., Collinger, J. L., Foldes, S. T., Weber, D. J., Chen, W., Boninger, M. L., & Wang, W.
Affiliations
  • University of Pittsburgh (US)
  • Washington University in St. Louis (US)
  • Barrow Neurological Institute (US)
  • Barnes-Jewish Hospital (US)
Corresponding author
Wang, Wei
Venue
PLOS ONE
Published
2017-05-10
Volume
12
Issue
5
Pages
e0176020
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2612430951
Cited by
122
References
28
Citations by year
2026: 8 · 2025: 8 · 2024: 10 · 2023: 19 · 2022: 15 · 2021: 24 · 2020: 16 · 2019: 13 · 2018: 7 · 2017: 2
FWCI
5.08
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, public-domain)
  • PubMed Central (publishedVersion, public-domain)
  • PubMed (publishedVersion)
  • Digital Commons@Becker (Washington University School of Medicine) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • TUScholarShare (Temple University) (submittedVersion, public-domain)
Funders
  • National Institute of Neurological Disorders and Stroke (3R01NS050256-05S1)
  • National Center for Advancing Translational Sciences (8KL2TR000146)
  • Paralyzed Veterans of America (PVA#3039)
  • University of Pittsburgh Medical Center
  • University of Pittsburgh Medical Center Rehabilitation Institute (US)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
Keywords
electrocorticography, somatosensory feedback, brain-computer interface, somatosensory cortex, brachial plexus injury, upper limb paralysis, pulse amplitude, pulse frequency, pulse duration, sensory perception, neuroprosthetics
MeSH terms
Brain Mapping, Electric Stimulation, Electrodes, Electrodes, Implanted, Humans, Somatosensory Cortex, Brain-Computer Interfaces

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Human perception of electrical stimulation on the surface of somatosensory cortex. https://app.cochat.ai/papers/10.1371/journal.pone.0176020
The paper
Hiremath, S. V., Tyler-Kabara, E. C., Wheeler, J. J., Moran, D. W., Gaunt, R. A., Collinger, J. L., Foldes, S. T., Weber, D. J., Chen, W., Boninger, M. L., & Wang, W. (2017). Human perception of electrical stimulation on the surface of somatosensory cortex. PLOS ONE. https://doi.org/10.1371/journal.pone.0176020

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.