Human perception of electrical stimulation on the surface of somatosensory cortex
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
Recent advancement in electrocorticography (ECoG)-based brain-computer interface technology has sparked a new interest in providing somatosensory feedback using ECoG electrodes, i.e., cortical surface electrodes. We conducted a 28-day study of cortical surface stimulation in an individual with arm paralysis due to brachial plexus injury to examine the sensation produced by electrical stimulation of the somatosensory cortex. A high-density ECoG grid was implanted over the somatosensory and motor cortices. Stimulation through cortical surface electrodes over the somatosensory cortex successfully elicited arm and hand sensations in our participant with chronic paralysis. There were three key findings. First, the intensity of perceived sensation increased monotonically with both pulse amplitude and pulse frequency. Second, changing pulse width changed the type of sensation based on qualitative description provided by the human participant. Third, the participant could distinguish between stimulation applied to two neighboring cortical surface electrodes, 4.5 mm center-to-center distance, for three out of seven electrode pairs tested. Taken together, we found that it was possible to modulate sensation intensity, sensation type, and evoke sensations across a range of locations from the fingers to the upper arm using different stimulation electrodes even in an individual with chronic impairment of somatosensory function. These three features are essential to provide effective somatosensory feedback for neuroprosthetic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The first is penetrating microelectrodes with low-charge/phase thresholds, high-charge density thresholds and smaller surface area, which are more suitable for stimulating specific functional areas in a selective and high spatial resolution way.[543,544]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [544]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Some Utah electrodes also use flexible substrates to improve their adaptability to complex surface.[544]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [544]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
A permanent change in brain function resulting from daily electrical stimulation
Goddard, G. V., McIntyre, D. C., & Leech, C. K. (1969) · Experimental Neurology · doi:10.1016/0014-4886(69)90128-9 · Cited by 3,052
(1909) · Cited by 2,575
Ditunno, J. F., Young, W., Donovan, W. H., & Creasey, G. (1994) · Spinal Cord · doi:10.1038/sc.1994.13 · Cited by 1,643
(1985) · Journal of Affective Disorders · doi:10.1016/0165-0327(85)90062-x · Cited by 1,254
The Cerebral Cortex of Man: A Clinical Study of Localization of Function
(1968) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1968.03150020096041 · Cited by 1,214
Spectral Changes in Cortical Surface Potentials during Motor Movement
Miller, K. J., Leuthardt, E. C., Schalk, G., Rao, R. P. N., Anderson, N. R., Moran, D. W., Miller, J. W., & Ojemann, J. G. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.3886-06.2007 · Cited by 738
Self-citationCharge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704
Self-citationActive tactile exploration using a brain–machine–brain interface
O’Doherty, J. E., Lebedev, M. A., Ifft, P. J., Zhuang, K. Z., Shokur, S., Bleuler, H., & Nicolelis, M. A. L. (2011) · Nature · doi:10.1038/nature10489 · Cited by 629
Cited by
A brain-computer interface that evokes tactile sensations improves robotic arm control
Flesher, S. N., Downey, J. E., Weiss, J. M., Hughes, C. L., Herrera, A. J., Tyler-Kabara, E. C., Boninger, M. L., Collinger, J. L., & Gaunt, R. A. (2021) · Science · doi:10.1126/science.abd0380 · Cited by 617
Self-citationFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Materials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498
Bioelectronics for electrical stimulation: materials, devices and biomedical applications
Huang, Y., Yao, K., Zhang, Q., Huang, X., Chen, Z., Zhou, Y., & Yu, X. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00413b · Cited by 183
The state of clinical trials of implantable brain–computer interfaces
Patrick-Krueger, K. M., Burkhart, I., & Contreras-Vidal, J. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00239-5 · Cited by 125
Decoding Movement From Electrocorticographic Activity: A Review
Volkova, K., Lebedev, M. A., Kaplan, A., & Ossadtchi, A. (2019) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2019.00074 · Cited by 110
“We foresee that the next series of major advances will be made in bidirectional BCI technology that combines motorcontrol loops with sensory feedback provided by cortical stimulation and/or sensory substitution methods (Wilson et al., 2012; Cronin et al., 2016; Hiremath et al., 2017).”
BackgroundBrain Computer Interfaces in Rehabilitation Medicine
Bockbrader, M. A., Francisco, G. E., Lee, R., Olson, J. D., Solinsky, R. J., & Boninger, M. L. (2018) · PM&R · doi:10.1016/j.pmrj.2018.05.028 · Cited by 126
“For example, brain stimulation on upper limb areas of somatosensory cortex evokes tingling in discrete hand areas based on cortical location of stimulation [27].”
BackgroundSelf-citationNeuroprosthetics: from sensorimotor to cognitive disorders
Gupta, A., Vardalakis, N., & Wagner, F. B. (2023) · Communications Biology · doi:10.1038/s42003-022-04390-w · Cited by 121
Fifer, M. S., McMullen, D. P., Osborn, L. E., Thomas, T. M., Christie, B., Nickl, R. W., Candrea, D. N., Pohlmeyer, E. A., Thompson, M. C., Anaya, M. A., et al. (2022) · Neurology · doi:10.1212/wnl.0000000000013173 · Cited by 103
Engineering Artificial Somatosensation Through Cortical Stimulation in Humans
Lee, B., Kramer, D., Armenta Salas, M., Kellis, S., Brown, D., Dobreva, T., Klaes, C., Heck, C., Liu, C., & Andersen, R. A. (2018) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2018.00024 · Cited by 91
“Only one previous study with a different high-density ECoG grid was able to get a rough somatotopic representation of the hand and arm, but could not distinguish receptive fields within the hand (Hiremath et al., 2017).”
BackgroundResultInfluentialCaldwell, D. J., Ojemann, J. G., & Rao, R. P. N. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00804 · Cited by 81
“Prior work has shown that humans can respond to DES of the surface of the primary somatosensory (S1) cortex (Ray et al., 1999; Libet et al., 1964; Johnson et al., 2013; Hiremath et al., 2017), which results in an artificial sensory percept organized according to the standard somatotopy of cortex.”
BackgroundPu, H., Malekzadeh-Arasteh, O., Danesh, A. R., Nenadić, Z., Do, A. H., & Heydari, P. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3108578 · Cited by 79
Extensive Cortical Convergence to Primate Reticulospinal Pathways
Fisher, K. M., Zaaimi, B., Edgley, S. A., & Baker, S. N. (2020) · Journal of Neuroscience · doi:10.1523/jneurosci.1379-20.2020 · Cited by 74
“2mA; this is comparable to motor thresholds measured in human patients with epicortical grid electrodes over M1 (2–7mA; Hiremath et al., 2017).”
BackgroundInfluentialSchofield, J. S., Shell, C. E., Beckler, D. T., Thumser, Z. C., & Marasco, P. D. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00120 · Cited by 68
“, 2015), and direct cortical stimulation of the primary somatosensory cortex (e.g., Tabot et al., 2013; Hiremath et al., 2017).”
BackgroundBidirectional brain-computer interfaces
Hughes, C. L., Herrera, A. J., Gaunt, R. A., & Collinger, J. L. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00013-5 · Cited by 81
Self-citationDegenhart, A. D., Hiremath, S. V., Yang, Y., Foldes, S., Collinger, J. L., Boninger, M., Tyler-Kabara, E. C., & Wang, W. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9bfb · Cited by 52
“Head radiographs from subjects S1 and S3 are reproduced from [32], respectively.”
BackgroundMethodSelf-citationSzymanski, L. J., Kellis, S., Liu, C. Y., Jones, K. T., Andersen, R. A., Commins, D., Lee, B., McCreery, D. B., & Miller, C. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac127e · Cited by 46
Caldwell, D. J., Cronin, J. A., Wu, J., Weaver, K. E., Ko, A. L., Rao, R. P. N., & Ojemann, J. G. (2019) · Scientific Reports · doi:10.1038/s41598-019-38619-2 · Cited by 54
Eles, J. R., & Kozai, T. D. Y. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.119767 · Cited by 49
Flexible Microinterventional Sensors for Advanced Biosignal Monitoring
Liu, Y., Fan, P., Pan, Y., & Ping, J. F. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.5c00115 · Cited by 43
Chandrasekaran, S., Fifer, M. S., Bickel, S., Osborn, L. E., Herrero, J. L., Christie, B. P., Xu, J., Murphy, R. K. J., Singh, S., Glasser, M. F., et al. (2021) · Bioelectronic Medicine · doi:10.1186/s42234-021-00076-6 · Cited by 45
“…microstimulation (ICMS) via microelectrode arrays (Fifer et al. 2020; Flesher et al. 2016a, 2016b; Salas et al. 2018) or cortical surface stimulation using electrocorticogra-phy (ECoG) grids (Hiremath et al. 2017; Kramer et al. 2021; Lee et al. 2018) in S1, specifically Brodmann ’ s area 1.”
MethodSelf-citationExploring Cognition with Brain–Machine Interfaces
Andersen, R. A., Aflalo, T., Bashford, L., Bjånes, D. A., & Kellis, S. (2022) · Annual Review of Psychology · doi:10.1146/annurev-psych-030221-030214 · Cited by 47
“One method to provide this stimulation is by delivering electric current through electrocorticography (ECoG) contacts (Hiremath et al. 2017, Lee et al. 2018).”
BackgroundMethodZhang, J., Hao, M., Yang, F., Liang, W., Sun, A., Chou, C.-H., & Lan, N. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac6062 · Cited by 40
“The nature of interface, stimulation location, and stimulation parameters determine perceptual qualities [9, 10, 13, 17, 18] and multiple sensory types for invasive stimulation techniques [8, 16, 19, 20].”
BackgroundHolmes, N. P., & Tamè, L. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00614.2018 · Cited by 38
Soft, conformal PDMS-based ECoG electrode array for long-term in vivo applications
Moon, H., Jang, J., Park, S., Kim, J.-H., Kim, J. S., & Kim, S. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.135099 · Cited by 40
A modular strategy for next-generation upper-limb sensory-motor neuroprostheses
Shokur, S., Mazzoni, A., Schiavone, G., Weber, D. J., & Micera, S. (2021) · Med · doi:10.1016/j.medj.2021.05.002 · Cited by 37
Self-citationQuantum information theoretic approach to the mind–brain problem
Georgiev, D. D. (2020) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2020.08.002 · Cited by 37
Remote-Controlled Fully Implantable Neural Stimulator for Freely Moving Small Animal
Yun, S., Koh, C. S., Jeong, J., Seo, J., Ahn, S.-H., Choi, G. J., Shim, S., Shin, J., Jung, H. H., Chang, J. W., et al. (2019) · Electronics · doi:10.3390/electronics8060706 · Cited by 34
Ji, B., Sun, F., Guo, J., Zhou, Y., You, X., Ye, F., Wang, L., Xu, M., Zeng, W., Liu, J., et al. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00597-x · Cited by 29
“Currently, most commercially available ECoG cortical electrodes are the macro-electrodes composed of silicone and platinum-iridium alloy 26,27 , such as conventional ECoG devices from Cortec GmbH, g.tec medical engineering GmbH, PMT Corporation, Ad-Tech Medical Instrument Corporation, etc.”
BackgroundSignal recovery from stimulation artifacts in intracranial recordings with dictionary learning
Caldwell, D. J., Cronin, J. A., Rao, R. P. N., Collins, K. L., Weaver, K. E., Ko, A. L., Ojemann, J. G., Kutz, J. N., & Brunton, B. W. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab7a4f · Cited by 30
Chandrasekaran, S., Bickel, S., Herrero, J. L., Kim, J.-W., Markowitz, N., Espinal, E., Bhagat, N. A., Ramdeo, R., Xu, J., Glasser, M. F., et al. (2021) · Brain stimulation · doi:10.1016/j.brs.2021.07.009 · Cited by 29
Achieving Neural Compatibility With Human Sensorimotor Control in Prosthetic and Therapeutic Devices
Lan, N., Niu, C. M., Hao, M., Chou, C.-H., & Dai, C. (2019) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2019.2930356 · Cited by 28
“gies have emerged as promising means to communicate sensory information to the brain of amputees and patients with spinal cord injury [104]–[106].”
BackgroundLong-term flexible penetrating neural interfaces: materials, structures, and implantation
Gu, C., Jiang, J., Tao, T. H., Wei, X., & Sun, L. (2021) · Science China Information Sciences · doi:10.1007/s11432-021-3321-7 · Cited by 24
A Psychometric Platform to Collect Somatosensory Sensations for Neuroprosthetic Use
Valle, G., Iberite, F., Strauss, I., D’Anna, E., Granata, G., Iorio, R. D., Stieglitz, T., Raspopović, S., Petrini, F. M., Rossini, P. M., et al. (2021) · Frontiers in Medical Technology · doi:10.3389/fmedt.2021.619280 · Cited by 24
“Several research groups have investigated the ability to restore sensory feedback in patients with upper or lower limb amputation, tetraplegia or paraplegia using invasive [2–11] and non-invasive [12–15] interfaces with the PNS and the CNS (Figure 1).”
BackgroundKramer, D. R., Lee, M. B., Barbaro, M. F., Gogia, A. S., Peng, T. D., Liu, C. Y., Kellis, S., & Lee, B. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab7c8e · Cited by 22
“Hiremath et al completed a 28 d study of upper extremity sensory restoration of in a patient with chronic sensory impairment due to brachial plexus injury [14].”
BackgroundThe Short-Term Repeatability of Subdermal Electrical Stimulation for Sensory Feedback
Dong, J. C., Kamavuako, E. N., Dosen, S. S., Jensen, W., & Geng, B. (2020) · IEEE Access · doi:10.1109/access.2020.2984534 · Cited by 20
“This can be achieved by using implanted interfaces to directly stimulate peripheral nerves via circumferential electrodes [18], [19] or intraneural electrodes [20]–[24], or through the application of cortical surface stimulation [25], [26] and intracortical microstimulation [27], [28].”
BackgroundMcMullen, D. P., Thomas, T. M., Fifer, M. S., Candrea, D. N., Tenore, F. V., Nickl, R. W., Pohlmeyer, E. A., Coogan, C. G., Osborn, L. E., Schiavi, A. J., et al. (2021) · Journal of neurosurgery · doi:10.3171/2020.9.jns202675 · Cited by 23
Workshops of the eighth international brain–computer interface meeting: BCIs: the next frontier
Huggins, J. E., Krusienski, D. J., Vansteensel, M. J., Valeriani, D., Thelen, A., Stavisky, S. D., Norton, J. J. S., Nijholt, A., Müller-Putz, G., Kosmyna, N., et al. (2022) · Brain-Computer Interfaces · doi:10.1080/2326263x.2021.2009654 · Cited by 21
Self-citationCortical maps of somatosensory perception in human
Ryun, S., Kim, M., Kim, J. S., & Chung, C. K. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120197 · Cited by 19
“However, unlike the ICMS study, we were not able to directly change the stimulus parameters because the present research was retrospective.”
BackgroundInfluentialPreserved cortical somatotopic and motor representations in tetraplegic humans
Andersen, R. A., & Aflalo, T. (2022) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2022.102547 · Cited by 19
Central nervous system microstimulation: Towards selective micro-neuromodulation
Urdaneta, M. E., Koivuniemi, A. S., & Otto, K. J. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.012 · Cited by 16
Sensory information feedback for neural prostheses
Weber, D. J., Hao, M., Urbin, M. A., Schoenewald, C., & Lan, N. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816034-3.00021-3 · Cited by 17
Self-citationZheng, X. S., Yang, Q., Vazquez, A. L., & Cui, X. T. (2021) · Advanced NanoBiomed Research · doi:10.1002/anbr.202000092 · Cited by 17
Power Budget of a Skull Unit in a Fully-Implantable Brain-Computer Interface: Bio-Heat Model
Serrano-Amenos, C., Heydari, P., Liu, C. Y., Do, A. H., & Nenadić, Z. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3323916 · Cited by 16
“After extensive literature review [62], [72], [73], [74], [75], [76], [78], we found that artificial sensation could be elicited by subdural electrostimulation with activation thresholds ranging from 35 to 700 µ C · Hz.”
BackgroundMethodInfluentialDanesh, A. R., Pu, H., Safiallah, M., Do, A. H., Nenadić, Z., & Heydari, P. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3391190 · Cited by 15
“Meanwhile, cortical stimulation through ECoG electrode array requires up to ∼ 10-mA of current to evoke artificial sensation [11].”
Innovations in Electrical Stimulation Harness Neural Plasticity to Restore Motor Function
Peng, X., Hickman, J. L., Bowles, S. G., Donegan, D., & Welle, C. G. (2018) · Bioelectronics in Medicine · doi:10.2217/bem-2019-0002 · Cited by 13
Somatosensation Evoked by Cortical Surface Stimulation of the Human Primary Somatosensory Cortex
Kirin, S. C., Yanagisawa, T., Oshino, S., Edakawa, K., Tanaka, M., Kishima, H., & Nishimura, Y. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01019 · Cited by 12
Introduction to somatosensory neuroprostheses
Güçlü, B. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00022-8 · Cited by 12
Injecting Information into the Mammalian Cortex: Progress, Challenges, and Promise
Mazurek, K. A., & Schieber, M. H. (2020) · The Neuroscientist · doi:10.1177/1073858420936253 · Cited by 12
Pu, H., Lim, J., Kellis, S., Liu, C. Y., Andersen, R. A., Do, A. H., Heydari, P., & Nenadić, Z. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab82ac · Cited by 11
Hong, Y., Ryun, S., & Chung, C. K. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1428256 · Cited by 10
Sohn, W. J., Lim, J., Wang, P. T., Pu, H., Malekzadeh-Arasteh, O., Shaw, S. J., Armacost, M., Gong, H., Kellis, S., Andersen, R. A., et al. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.1075971 · Cited by 9
“BD-BCI research initially largely focused on characterizing how various stimulation parameters could evoke different modalities of sensation (Johnson et al., 2013; Cronin et al., 2016; Collins et al., 2017; Hiremath et al., 2017; Lee et al., 2018; Caldwell et al., 2019).”
BackgroundLim, J., Wang, P. T., Pu, H., Liu, C. Y., Kellis, S., Andersen, R. A., Heydari, P., Do, A. H., & Nenadić, Z. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8716961 · Cited by 9
“Recent human studies [3], [4] used subdurally implanted ECoG”
Real-time brain-computer interface control of walking exoskeleton with bilateral sensory feedback
Lim, J., Wang, P. T., Sohn, W. J., Lin, D., Thaploo, S., Bashford, L., Bjånes, D. A., Nguyen, A., Gong, H., Armacost, M., et al. (2026) · Brain stimulation · doi:10.1016/j.brs.2026.103065 · Cited by 8
Towards precise synthetic neural codes: high-dimensional stimulation with flexible electrodes
Kim, R., Liu, Y., Zhang, J., Xie, C., & Luan, L. (2025) · npj Flexible Electronics · doi:10.1038/s41528-025-00447-y · Cited by 7
“Surface arrays, while offering wide spatial coverage, typically require higher stimulation amplitudes due to their considerable distance from the cortex, typically ranging from hundreds of microamps to milliamps 23,52,56 .”
Kramer, D. R., Lamorie‐Foote, K., Barbaro, M. F., Lee, M. B., Peng, T. D., Gogia, A. S., Nune, G. C., Liu, C. Y., Kellis, S., & Lee, B. (2020) · Neurosurgical FOCUS · doi:10.3171/2019.11.focus19696 · Cited by 8
“8,9,16 Below 20 Hz, subjects did not report somato-sensation, and at 20 Hz, they described the stimulation as “inconsistent.””
BackgroundBrain–computer interfaces for human gait restoration
Nenadić, Z. (2021) · Control Theory and Technology · doi:10.1007/s11768-021-00070-y · Cited by 9
“ECoG grids are also FDA-approved for cortical electrostimulation, which when delivered over the sensory cortex, can elicit artificial sensation [52, 53].”
BackgroundLim, J., Wang, P. T., Karimi-Bidhendi, A., Malekzadeh-Arasteh, O., Shaw, S. J., Armacost, M., Gong, H., Liu, C. Y., Heydari, P., Do, A. H., et al. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513216 · Cited by 7
“ECoG grid cortical stimulation has recently been reported in [6], although not in the context of BCI control.”
Artificial sensory feedback for bionic hands
Downey, J. E., Brooks, J., & Bensmaïa, S. J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814942-3.00008-8 · Cited by 7
BCI-Based Neuroprostheses and Physiotherapies for Stroke Motor Rehabilitation
Lim, J., Lin, D., Sohn, W. J., McCrimmon, C. M., Wang, P. T., Nenadić, Z., & Do, A. H. (2022) · Springer eBooks · doi:10.1007/978-3-031-08995-4_22 · Cited by 6
Yoo, K. (2023) · Journal of Exercise Rehabilitation · doi:10.12965/jer.2346242.121 · Cited by 8
“This concept is reinforced by the emerging trend in braincomputer interfaces (BCIs) wherein researchers focus on developing technologies that enable the extraction of brain activity signals for motor control and somatosensory feedback, allowing for the restoration of lost motor functions through the development of dec…”
Suppression of cortical electrostimulation artifacts using pre-whitening and null projection
Lim, J., Wang, P. T., Bashford, L., Kellis, S., Shaw, S. J., Gong, H., Armacost, M., Heydari, P., Do, A. H., Andersen, R. A., et al. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acf68b · Cited by 7
“Invasive BCIs based on electrocorticography (ECoG) [10, 11] or intracortical microelectrode arrays (MEAs) [12, 13] have the ability to elicit somatosensation via electrostimulation of cortical tissue.”
A self-powered wearable brain–machine-interface system for ceasing action
Wang, X., Xie, Y., Han, Y., Long, Z., Zhang, W., Zhong, T., Liang, S., Xing, L., Xue, X., & Zhan, Y. (2022) · Nanoscale · doi:10.1039/d1nr08168c · Cited by 7
Artifact propagation in subdural cortical electrostimulation: Characterization and modeling
Lim, J., Wang, P. T., Shaw, S. J., Gong, H., Armacost, M., Liu, C. Y., Do, A. H., Heydari, P., & Nenadić, Z. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.1021097 · Cited by 6
“However, recent studies (Hiremath et al., 2017; Lee et al., 2018) have demonstrated that electrostimulation via subdurally implanted ECoG grids can elicit somatosensory percepts.”
BackgroundInfluentialObara, K., Kaneshige, M., Suzuki, M., Yokoyama, O., Tazoe, T., & Nishimura, Y. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1127095 · Cited by 6
“Furthermore, there is a linear relationship between current intensity and the perceived intensity of the evoked sensation (Johnson et al., 2013; Hiremath et al., 2017; Lee et al., 2018; Kirin et al., 2019).”
BackgroundFunctional Frequency Discrimination From Cortical Somatosensory Stimulation in Humans
Kramer, D. R., Lamorie‐Foote, K., Barbaro, M. F., Lee, M., Peng, T. D., Gogia, A. S., Liu, C. Y., Kellis, S., & Lee, B. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00832 · Cited by 6
Howell, P., Rabe, F., Meneghin, C., Schading‐Sassenhausen, S., Schone, H. R., Sonar, H., Paik, J. K., Freund, P., Wenderoth, N., & Kikkert, S. (2026) · Journal of Neuroscience · doi:10.1523/jneurosci.0644-25.2026 · Cited by 6
Neurosurgery and the Brain-Computer Interface
Rosenfeld, J. V. (2024) · Advances in experimental medicine and biology · doi:10.1007/978-3-031-64892-2_32 · Cited by 8
Sohn, W. J., Wang, P. T., Kellis, S., Andersen, R. A., Liu, C. Y., Heydari, P., Nenadić, Z., & Do, A. H. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176718 · Cited by 5
“0 kΩ load (a typical electrode impedance above somatosensory cortex is <600Ω between two neighboring channels [15]) therefore supply voltage as high as 15V is required.”
BackgroundFoldes, S. T., Chandrasekaran, S., Camerone, J., Lowe, J., Ramdeo, R., Ebersole, J. S., & Bouton, C. E. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.739693 · Cited by 5
“The MEG mapping approach reported here may also be useful in placement of other implant types such as subdural or depth electrocorticography electrodes which have also been demonstrated in evoking focal tactile percepts in the hand (Chandrasekaran et al., 2020; Hiremath et al., 2017).”
BackgroundSelf-citationXu, D., Hong, J., Park, K., & Ahn, J. (2026) · Small · doi:10.1002/smll.202514286 · Cited by 5
Badi, M., Borgognon, S., O’Doherty, J. E., & Shokur, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00008-3 · Cited by 5
Idowu, O. P., Huang, J., Zhao, Y., Samuel, O. W., Yu, M., Fang, P., & Li, G. (2020) · Cognitive Neurodynamics · doi:10.1007/s11571-020-09603-8 · Cited by 4
Multimodal Integrative Perception : Biological correlates and qualitative experiences
Maldonato, N. M., Sperandeo, R., Coco, M., Cioffi, V., de Lucia, S., Mosca, L. L., & Esposito, A. A. (2020) · IEEE International Conference on Cognitive Infocommunications · doi:10.1109/coginfocom50765.2020.9237912 · Cited by 4
“Somatosensory inputs are transmitted in a reasonably short conduction time to the brain [26].”
BackgroundAn artificial nervous system to treat chronic stroke
Serruya, M. D., & Rosenwasser, R. H. (2021) · Artificial Organs · doi:10.1111/aor.13998 · Cited by 5
Touch restoration through electrical cortical stimulation in humans
Caldwell, D. J., Cronin, J. A., Levinson, L. H., & Rao, R. P. N. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00021-6 · Cited by 4
Early feasibility of an embedded bi-directional brain-computer interface for ambulation
Lim, J., Wang, P. T., Sohn, W. J., Serrano-Amenos, C., Ibrahim, M., Lin, D., Thaploo, S., Shaw, S. J., Armacost, M., Gong, H., et al. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10782271 · Cited by 4
“In contrast, invasive BCI can potentially incorporate artificial somatic sensation via direct cortical electrical stimulation (DCES) of sensory areas [6], [7].”
Supracortical Microstimulation: Advances in Microelectrode Design and In Vivo Validation
Schmitz, C. M., Smith, J. E., Rachinskiy, I., Pesaran, B., Vitale, F., Sommer, M. A., & Viventi, J. (2025) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-103023-072855 · Cited by 3
Coordinates for the somatosensory homunculus
Schieber, M. H. (2018) · The Journal of Physiology · doi:10.1113/jp275765 · Cited by 3
“Current efforts directed at the development of neuroprosthetic devices are providing such opportunities via electrocorticography grids (Hiremath et al. 2017) and penetrating microelectrode arrays (Flesher et al. 2016) implanted in human patients for days to months.”
BackgroundRestoring the sense of touch with electrical stimulation of the nerve and brain
Callier, T., & Bensmaïa, S. J. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00010-1 · Cited by 3
Artificial Sensory Feedback to the Brain: Somatosensory Feedback for Neural Devices and BCI
Bjånes, D. A., & Moritz, C. T. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_111-2 · Cited by 4
Human psychophysics of direct cortical stimulation of somatosensory cortex
Cronin, J. A. (2018) · ResearchWorks at the University of Washington (University of Washington) · Cited by 4
Pan, L., Lun, J., Ren, Z., Zhao, H., Mu, R., & Li, J. (2025) · Journal of Bionic Engineering · doi:10.1007/s42235-025-00810-9 · Cited by 2
“The pulse frequency was set to 150 Hz, since the human body shows a better perceptual resolution at 100–200 Hz electrical stimulation [34, 35].”
Restoring vision and touch with cortical microstimulation
Valle, G., Oswalt, D. N., Gaunt, R. A., Roelfsema, P. R., Greenspon, C. M., & Fernandez, E. (2026) · Nature Reviews Bioengineering · doi:10.1038/s44222-026-00449-z · Cited by 2
“In S1, direct electrical stimulation evokes sensations such as tingling, buzzing, pressure or tapping 22,44,65 , with changes in ICMS parameters altering intensity, size and qualitative composition 72 .”
Self-citationChen, Q., Huang, N., Tong, C., Liu, P., Que, S., Xue, H., Xiao, X., & Song, E. (2026) · npj Biosensing · doi:10.1038/s44328-026-00109-7 · Cited by 4
Brain Computer Interface for the Hand Function Restoration
Zhang, X., Song, Z., Li, S., Zhang, Y., Fang, T., Wang, S., Li, H., Lin, Y., Jia, J., Zhang, L., et al. (2021) · International Winter Conference on Brain-Computer Interface (BCI) · doi:10.1109/bci51272.2021.9385348 · Cited by 4
“Hiremath et al. conducted a 28-day study of cortical surface stimulation in an individual with arm paralysis due to brachial plexus injury to examine the sensation produced by electrical stimulation of the somatosensory cortex [30].”
BackgroundSomatosensory Neuromodulation with a Focus Towards Clinical Systems
Graczyk, E. L., & Tyler, D. J. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_92-1 · Cited by 2
Gozzi, N., & Valle, G. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-18498-7.00014-4 · Cited by 4
Bülbül, D. K., Walston, S. T., Duvan, F. T., Garrido, J. A., & Güçlü, B. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad9405 · Cited by 2
“Several studies also showed artificial tactile sensations elicited by the stimulation of human S1 with ECoG electrode arrays (Hiremath et al 2017, Lee et al 2018).”
Nielsen, M. T. H., Emonds, A. M., Iskarous, M. M., Alamri, A. H., Roldan, L. M., Bose, R., Graczyk, E. L., & Greenspon, C. M. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3737698 · Cited by 3
“…this typically involves annotation of a flattened representation of the arm or leg in a 2D plane on a piece of paper or digital tablet [3], [4], [5], [6], [7], [8], [9], [10], [11], [12], [13], [14], [15], [16], [17], [18], [19], [20] ( Figure 1A , B ), similar to tactile receptive field…”
Lim, J., Wang, P. T., Shaw, S. J., Armacost, M., Gong, H., Liu, C. Y., Do, A. H., Heydari, P., & Nenadić, Z. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175760 · Cited by 2
“Additionally, subdural ECoG electrodes can elicit somatosensation by delivering cortical electrostimulation [3], [4].”
BackgroundResultBjånes, D. A., & Moritz, C. T. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00018-6 · Cited by 2
Touching the Void: Intracranial Stimulation for NeuroHaptic Feedback in Virtual Reality
Paschall, C. J., Hauptman, J. S., Rao, R. P. N., Ojemann, J. G., & Herron, J. A. (2022) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc53654.2022.9945366 · Cited by 3
“DCS by variation of pulse amplitude, pulse width, pulse frequency, and burst frequency [4,6,7,8,9].”
BackgroundMethodGschwind, C. R., Ledgard, J. P., & Scott, T. R. D. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_55 · Cited by 2
Osborn, L. E., Betthauser, J., & Thakor, N. V. (2019) · Wiley eBooks · doi:10.1002/047134608x.w1424.pub2 · Cited by 4
Single and Multi-Site Cortical Stimulation Related to Human Sensorimotor FunctionPreprint
Ryun, S., & Chung, C. K. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.01.18.574786 · Cited by 2
Hughes, C. L. (2021) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 4
Noninvasive and Invasive BCIs and Hardware and Software Components for BCIs
Guger, C., Grünwald, J., & Xu, R. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_34-2 · Cited by 3
Motor BMIs Have Entered the Clinical Realm
Caldwell, D. J., Herron, J. A., Ko, A. L., & Ojemann, J. G. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_108-1 · Cited by 1
Neurosurgical Considerations for the Brain Computer Interface
Rosenfeld, J. V., Wong, Y. T., Szlawski, J., & Gutman, M. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_38-1 · Cited by 1
Metadata
- Authors
- Hiremath, S. V., Tyler-Kabara, E. C., Wheeler, J. J., Moran, D. W., Gaunt, R. A., Collinger, J. L., Foldes, S. T., Weber, D. J., Chen, W., Boninger, M. L., & Wang, W.
- Affiliations
- University of Pittsburgh (US)
- Washington University in St. Louis (US)
- Barrow Neurological Institute (US)
- Barnes-Jewish Hospital (US)
- Corresponding author
- Wang, Wei
- ORCID
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-05-10
- Volume
- 12
- Issue
- 5
- Pages
- e0176020
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC5425101
- OpenAlex
- W2612430951
- Semantic Scholar
- d7d0e92e52073e41abbb829d501115269871b176
- Cited by
- 122
- References
- 28
- Citations by year
- 2026: 8 · 2025: 8 · 2024: 10 · 2023: 19 · 2022: 15 · 2021: 24 · 2020: 16 · 2019: 13 · 2018: 7 · 2017: 2
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- public-domain
- creativecommons.org/publicdomain/zero/1.0/ (vor)
- Locations
- PLoS ONE (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- Digital Commons@Becker (Washington University School of Medicine) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- TUScholarShare (Temple University) (submittedVersion, public-domain)
- Funders
- National Institute of Neurological Disorders and Stroke (3R01NS050256-05S1)
- National Center for Advancing Translational Sciences (8KL2TR000146)
- Paralyzed Veterans of America (PVA#3039)
- University of Pittsburgh Medical Center
- University of Pittsburgh Medical Center Rehabilitation Institute (US)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- electrocorticography, somatosensory feedback, brain-computer interface, somatosensory cortex, brachial plexus injury, upper limb paralysis, pulse amplitude, pulse frequency, pulse duration, sensory perception, neuroprosthetics
- MeSH terms
- Brain Mapping, Electric Stimulation, Electrodes, Electrodes, Implanted, Humans, Somatosensory Cortex, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.