Automated Detection of Inaccurate and Imprecise Transitions in Peptide Quantification by Multiple Reaction Monitoring Mass Spectrometry
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Background: Multiple reaction monitoring mass spectrometry (MRM-MS) of peptides with stable isotope–labeled internal standards (SISs) is increasingly being used to develop quantitative assays for proteins in complex biological matrices. These assays can be highly precise and quantitative, but the frequent occurrence of interferences requires that MRM-MS data be manually reviewed, a time-intensive process subject to human error. We developed an algorithm that identifies inaccurate transition data based on the presence of interfering signal or inconsistent recovery among replicate samples. Methods: The algorithm objectively evaluates MRM-MS data with 2 orthogonal approaches. First, it compares the relative product ion intensities of the analyte peptide to those of the SIS peptide and uses a t-test to determine if they are significantly different. A CV is then calculated from the ratio of the analyte peak area to the SIS peak area from the sample replicates. Results: The algorithm identified problematic transitions and achieved accuracies of 94%–100%, with a sensitivity and specificity of 83%–100% for correct identification of errant transitions. The algorithm was robust when challenged with multiple types of interferences and problematic transitions. Conclusions: This algorithm for automated detection of inaccurate and imprecise transitions (AuDIT) in MRM-MS data reduces the time required for manual and subjective inspection of data, improves the overall accuracy of data analysis, and is easily implemented into the standard data-analysis work flow. AuDIT currently works with results exported from MRM-MS data-processing software packages and may be implemented as an analysis tool within such software.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
An introduction to ROC analysis
Fawcett, T. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.10.010 · Cited by 21,879
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Self-citationAbsolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832254100 · Cited by 1,733
Addona, T. A., Abbatiello, S. E., Schilling, B., Skates, S. J., Mani, D. R., Bunk, D. M., Spiegelman, C. H., Zimmerman, L. J., Ham, A.-J. L., Keshishian, H., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1546 · Cited by 1,037
Self-citationFull dynamic range proteome analysis of S. cerevisiae by targeted proteomics
Picotti, P., Bodenmiller, B., Mueller, L. N., Domon, B., & Aebersold, R. (2009) · Cell · doi:10.1016/j.cell.2009.05.051 · Cited by 744
400: A Method for Combining Non-Independent, One-Sided Tests of Significance
Brown, M. B. (1975) · Biometrics · doi:10.2307/2529826 · Cited by 473
Barr, J. R., Maggio, V. L., Patterson, D. G., Cooper, G. R., Henderson, L. O., Turner, W. E., Smith, S. J., Hannon, W. H., Needham, L. L., & Sampson, E. J. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.10.1676 · Cited by 347
Prakash, A., Tomazela, D. M., Frewen, B., MacLean, B., Merrihew, G., Peterman, S., & MacCoss, M. J. (2009) · Journal of Proteome Research · doi:10.1021/pr801028b · Cited by 147
Cited by
Selected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions
Picotti, P., & Aebersold, R. (2012) · Nature Methods · doi:10.1038/nmeth.2015 · Cited by 1,302
The Skyline ecosystem: Informatics for quantitative mass spectrometry proteomics
Pino, L. K., Searle, B. C., Bollinger, J. G., Nunn, B., MacLean, B., & MacCoss, M. J. (2020) · Mass Spectrometry Reviews · doi:10.1002/mas.21540 · Cited by 800
Carr, S. A., Abbatiello, S. E., Ackermann, B. L., Borchers, C., Domon, B., Deutsch, E. W., Grant, R. P., Hoofnagle, A. N., Hüttenhain, R., Koomen, J. M., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.036095 · Cited by 561
Self-citationmProphet: automated data processing and statistical validation for large-scale SRM experiments
Reiter, L., Rinner, O., Picotti, P., Hüttenhain, R., Beck, M., Brusniak, M.-Y., Hengartner, M. O., & Aebersold, R. (2011) · Nature Methods · doi:10.1038/nmeth.1584 · Cited by 532
“, the challenge of confidently identifying the target peptide has only recently been addresse”
BackgroundTargeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer
Gallien, S., Duriez, E., Crone, C., Kellmann, M., Moehring, T., & Domon, B. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.019802 · Cited by 510
Quantitative analysis of peptides and proteins in biomedicine by targeted mass spectrometry
Gillette, M. A., & Carr, S. A. (2013) · Nature Methods · doi:10.1038/nmeth.2309 · Cited by 495
Self-citationRauniyar, N. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms161226120 · Cited by 406
“Excessive amounts of heavy peptides, compared to endogenous peptide, will saturate the detector [51,52].”
BackgroundParallel reaction monitoring using quadrupole‐Orbitrap mass spectrometer: Principle and applications
Bourmaud, A., Gallien, S., & Domon, B. (2016) · PROTEOMICS · doi:10.1002/pmic.201500543 · Cited by 308
Parker, C. E., & Borchers, C. H. (2014) · Molecular Oncology · doi:10.1016/j.molonc.2014.03.006 · Cited by 238
“(Abbatiello et al., 2010; Domanski et al., 2012; Huttenhain et al., 2012; Kuzyk et al., 2013; Percy et al., 2013a, 2013b, 2013d; Sherman et al., 2009) Details of how interference testing is performed in our”
BackgroundPanorama: A Targeted Proteomics Knowledge Base
Sharma, V., Eckels, J., Taylor, G. K., Shulman, N. J., Stergachis, A. B., Joyner, S. A., Yan, P., Whiteaker, J. R., Halusa, G. N., Schilling, B., et al. (2014) · Journal of Proteome Research · doi:10.1021/pr5006636 · Cited by 223
Self-citationAbbatiello, S. E., Schilling, B., Mani, D. R., Zimmerman, L. J., Hall, S. C., MacLean, B., Albertolle, M., Allen, S., Burgess, M., Cusack, M. P., et al. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.047050 · Cited by 215
“In Phase I, three to five transitions per peptide were evaluated for interference in depleted plasma using AuDIT (50), and the three most abundant transitions with the least interference for each peptide were selected to monitor.”
MethodSelf-citationKennedy, J. J., Abbatiello, S. E., Kim, K., Yan, P., Whiteaker, J. R., Lin, C., Kim, J. S., Zhang, Y., Wang, X., Ivey, R. G., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2763 · Cited by 184
Self-citationLC–MS/MS for protein and peptide quantification in clinical chemistry
Rauh, M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.09.030 · Cited by 171
Generating and navigating proteome maps using mass spectrometry
Ahrens, C. H., Brunner, E., Qeli, E., Basler, K., & Aebersold, R. (2010) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2973 · Cited by 168
Boja, E. S., & Rodriguez, H. (2012) · PROTEOMICS · doi:10.1002/pmic.201100387 · Cited by 164
“Automated detection of inaccurate and imprecise transitions (AuDIT) [43] http://www.”
BackgroundMethodAgger, S. A., Marney, L. C., & Hoofnagle, A. N. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.152264 · Cited by 143
Neubert, H., Shuford, C. M., Olah, T. V., Garofolo, F., Schultz, G. A., Jones, B. R., Amaravadi, L., Laterza, O. F., Xu, K., & Ackermann, B. L. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvz022 · Cited by 109
Towards comprehensive and quantitative proteomics for diagnosis and therapy of human disease
Cifani, P., & Kentsis, A. (2017) · PROTEOMICS · doi:10.1002/pmic.201600079 · Cited by 101
Huth, C., von Toerne, C., Schederecker, F., de las Heras Gala, T., Herder, C., Kronenberg, F., Meisinger, C., Rathmann, W., Koenig, W., Waldenberger, M., et al. (2019) · European Journal of Epidemiology · doi:10.1007/s10654-018-0475-8 · Cited by 56
Quantifying Protein Measurands by Peptide Measurements: Where Do Errors Arise?
van den Broek, I., Romijn, F. P. H. T. M., Smit, N. P. M., van der Laarse, A., Drijfhout, J. W., van der Burgt, Y. E. M., & Cobbaert, C. M. (2015) · Journal of Proteome Research · doi:10.1021/pr5011179 · Cited by 49
van den Broek, I., Smit, N. P. M., Romijn, F. P. H. T. M., van der Laarse, A., Deelder, A. M., van der Burgt, Y. E. M., & Cobbaert, C. M. (2013) · Journal of Proteome Research · doi:10.1021/pr400763d · Cited by 49
Fert-Bober, J., Murray, C. I., Parker, S. J., & Van Eyk, J. E. (2018) · Circulation Research · doi:10.1161/circresaha.118.310966 · Cited by 45
Tsai, T.-H., Choi, M., Banfai, B., Liu, Y., MacLean, B. X., Dunkley, T., & Vitek, O. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.ra119.001792 · Cited by 31
Rezeli, M., Végvári, Á., Fehniger, T. E., Laurell, T., & Marko-Varga, G. (2011) · Journal of Clinical Bioinformatics · doi:10.1186/2043-9113-1-7 · Cited by 15
Quality requirements for quantitative clinical chemistry proteomics
(2014) · Translational Proteomics · doi:10.1016/j.trprot.2013.10.001 · Cited by 11
Metadata
- Authors
- Abbatiello, S. E., Mani, D. R., Keshishian, H., & Carr, S. A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-02-01
- Volume
- 56
- Issue
- 2
- Pages
- 291-305
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2062964117
- Cited by
- 198
- References
- 9
- FWCI
- 6.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.