The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Determination of volatile organic compounds in exhaled breath of patients with lung cancer using solid phase microextraction and gas chromatography mass spectrometry
Abstract
BACKGROUND: Analysis of exhaled breath is a promising diagnostic method. Sampling of exhaled breath is non-invasive and can be performed as often as considered desirable. There are indications that the concentration and presence of certain of volatile compounds in exhaled breath of lung cancer patients is different from concentrations in healthy volunteers. This might lead to a future diagnostic test for lung cancer. METHODS: Exhaled breath samples from 65 patients with different stages of lung cancer and undergoing different treatment regimes were analysed. Mixed expiratory and indoor air samples were collected. Solid phase microextraction (SPME) with carboxen/polydimethylsiloxane (CAR/PDMS) sorbent was applied. Compounds were analysed by means of gas chromatography (GC) and mass spectrometry (MS). RESULTS: The method we used allowed identification with the spectral library of 103 compounds showing at least 15% higher concentration in exhaled breath than in inhaled air. Among those 103 compounds, 84 were confirmed by determination of the retention time using standards based on the respective pure compound. Approximately, one third of the compounds detected were hydrocarbons. We found aromatic hydrocarbons, alcohols, aldehydes, ketones, esters, ethers, sulfur compounds, nitrogen-containing compounds and halogenated compounds. Acetonitrile and benzene were two of 10 compounds which correlated with smoking behaviour. A comparison of results from cancer patients with those of 31 healthy volunteers revealed differences in the concentration and presence of certain compounds. The sensitivity for detection of lung cancer patients based on eight different compounds not seen in exhaled breath of healthy volunteers was 51% and the specificity was 100%. These eight potential markers for detection of lung cancer are 1-propanol, 2-butanone, 3-butyn-2-ol, benzaldehyde, 2-methyl-pentane, 3-methyl-pentane, n-pentane and n-hexane. CONCLUSIONS: SPME is a relatively insensitive method and compounds not observed in exhaled breath may be present at a concentration lower than LOD. The main achievement of the present work is the validated identification of compounds observed in exhaled breath of lung cancer patients. This identification is indispensible for future work on the biochemical sources of these compounds and their metabolic pathways.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solid phase microextraction with thermal desorption using fused silica optical fibers
Arthur, C. L., & Pawliszyn, J. (1990) · Analytical Chemistry · doi:10.1021/ac00218a019 · Cited by 4,997
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Self-citationQuantitative Analysis of Urine Vapor and Breath by Gas-Liquid Partition Chromatography
Pauling, L., Robinson, A. B., Teranishi, R., & Cary, P. (1971) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.68.10.2374 · Cited by 1,025
Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918
Human exhaled air analytics: biomarkers of diseases
Buszewski, B., Kęsy, M., Ligor, T., & Amann, A. (2007) · Biomedical Chromatography · doi:10.1002/bmc.835 · Cited by 792
Self-citationVariation in volatile organic compounds in the breath of normal humans
Phillips, M., Herrera, J., Krishnan, S., Zain, M., Greenberg, J., & Cataneo, R. N. (1999) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00127-9 · Cited by 738
High nitric oxide production in human paranasal sinuses
Lundberg, J. O. N., Farkas-Szallasi, T., Weitzberg, E., Rinder, J., Lidholm, J., Änggåard, A., Hökfelt, T., Lundberg, J. M., & Alving, K. (1995) · Nature Medicine · doi:10.1038/nm0495-370 · Cited by 628
Detection of Lung Cancer by Sensor Array Analyses of Exhaled Breath
Machado, R. F., Laskowski, D., Deffenderfer, O., Burch, T., Zheng, S., Mazzone, P. J., Mekhail, T., Jennings, C., Stoller, J. K., Pyle, J., et al. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200409-1184oc · Cited by 602
Agresti, A., & Caffo, B. (2000) · The American Statistician · doi:10.1080/00031305.2000.10474560 · Cited by 569
Detection of Lung Cancer With Volatile Markers in the Breatha
Phillips, M., Cataneo, R. N., Cummin, A. R. C., Gagliardi, A. J., Gleeson, K., Greenberg, J., Maxfield, R. A., & Rom, W. N. (2003) · Chest · doi:10.1378/chest.123.6.2115 · Cited by 567
Poli, D., Carbognani, P., Corradi, M., Goldoni, M., Acampa, O., Balbi, B., Bianchi, L., Rusca, M., & Mutti, A. (2005) · Respiratory Research · doi:10.1186/1465-9921-6-71 · Cited by 415
The diagnostic potential of breath analysis.
Manolis, A. (1983) · Clinical Chemistry · doi:10.1093/clinchem/29.1.5 · Cited by 399
Turner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Prediction of lung cancer using volatile biomarkers in breath1
Phillips, M., Altorki, N., Austin, J. H. M., Cameron, R. B., Cataneo, R. N., Greenberg, J., Kloss, R., Maxfield, R. A., Munawar, M. I., Pass, H. I., et al. (2007) · Cancer Biomarkers · doi:10.3233/cbm-2007-3204 · Cited by 323
Solid-Phase Microextraction for the Analysis of Human Breath
Grote, C., & Pawliszyn, J. (1997) · Analytical Chemistry · doi:10.1021/ac960749l · Cited by 300
Volatile Markers of Breast Cancer in the Breath
Phillips, M., Cataneo, R. N., Ditkoff, B. A., Fisher, P., Greenberg, J., Gunawardena, R., Kwon, C. S., Rahbari-Oskoui, F., & Wong, C. (2003) · The Breast Journal · doi:10.1046/j.1524-4741.2003.09309.x · Cited by 289
Lung cancer detection by proton transfer reaction mass-spectrometric analysis of human breath gas
Wehinger, A., Schmid, A., Mechtcheriakov, S., Ledochowski, M., Grabmer, C., Gastl, G. A., & Amann, A. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.05.012 · Cited by 280
Self-citationHuman breath isoprene and its relation to blood cholesterol levels: new measurements and modeling
Karl, T., Prazeller, P., Mayr, D., Jordan, A., Rieder, J., Fall, R., & Lindinger, W. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.2.762 · Cited by 264
A study of the volatile organic compounds exhaled by lung cancer cells in vitro for breath diagnosis
Chen, X., Xu, F., Wang, Y., Pan, Y., Lu, D., Wang, P., Ying, K., Chen, E., & Zhang, W. (2007) · Cancer · doi:10.1002/cncr.22844 · Cited by 251
Applications of breath gas analysis in medicine
Amann, A., Poupart, G., Telser, S., Ledochowski, M., Schmid, A., & Mechtcheriakov, S. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.08.010 · Cited by 208
Self-citationRelease of volatile organic compounds (VOCs) from the lung cancer cell line CALU-1 in vitro
Filipiak, W., Sponring, A., Mikoviny, T., Ager, C., Schubert, J., Miekisch, W., Amann, A., & Troppmair, J. (2008) · Cancer Cell International · doi:10.1186/1475-2867-8-17 · Cited by 201
Self-citationBreath Analysis: The Approach Towards Clinical Applications
Amann, A., Spanel, P., & Smith, D. (2007) · Mini-Reviews in Medicinal Chemistry · doi:10.2174/138955707779802606 · Cited by 198
Self-citationRelease of volatile organic compounds from the lung cancer cell line NCI-H2087 in vitro.
Sponring, A., Filipiak, W., Mikoviny, T., Ager, C., Schubert, J. K., Miekisch, W., Amann, A., & Troppmair, J. (2009) · PubMed · Cited by 169
Self-citationEndogenous Production of Methanol after the Consumption of Fruit
Lindinger, W., Taucher, J. A., Jordan, A., Hansel, A., & Vogel, W. (1997) · Alcoholism Clinical and Experimental Research · doi:10.1111/j.1530-0277.1997.tb03862.x · Cited by 157
Ligor, T., Ligor, M., Amann, A., Ager, C., Bachler, M., Dzien, A., & Buszewski, B. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/4/046006 · Cited by 156
Self-citationKushch, I., Schwarz, K., Schwentner, L., Baumann, B., Dzien, A., Schmid, A., Unterkofler, K., Gastl, G., Španěl, P., Smith, D. C., et al. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/2/026002 · Cited by 155
Self-citationKushch, I., Arendacká, B., Štolc, S., Mochalski, P., Filipiak, W., Schwarz, K., Schwentner, L., Schmid, A., Dzien, A., Lechleitner, M., et al. (2008) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.181 · Cited by 150
Self-citationTurner, C., Španěl, P., & Smith, D. C. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/7/007 · Cited by 150
Turner, C., Španěl, P., & Smith, D. C. (2005) · Physiological Measurement · doi:10.1088/0967-3334/27/1/002 · Cited by 140
Jordan, A., Hansel, A., Holzinger, R., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04236-e · Cited by 136
Heart allograft rejection: detection with breath alkanes in low levels (the HARDBALL study)
Phillips, M., BOEHMER, J. P., Cataneo, R. N., Cheema, T., Eisen, H. J., Fallon, J. T., Fisher, P. E., Gass, A. L., Greenberg, J. H., KOBASHIGAWA, J. A., et al. (2004) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2003.07.017 · Cited by 119
Breath analysis in critically ill patients: potential and limitations
Schubert, J. K., Miekisch, W., Geiger, K. K., & Nöldge‐Schomburg, G. (2004) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.4.5.619 · Cited by 110
Self-citationSchubert, J. K., Miekisch, W., Birken, T., Geiger, K. K., & Nöldge‐Schomburg, G. (2005) · Biomarkers · doi:10.1080/13547500500050259 · Cited by 102
Self-citationPabst, F., Miekisch, W., Fuchs, P., Kischkel, S., & Schubert, J. K. (2007) · Journal of Cardiothoracic Surgery · doi:10.1186/1749-8090-2-37 · Cited by 92
Self-citationAnalysis of organic compounds in human breath by gas chromatography-mass spectrometry.
Jansson, B., & Larsson, B. T. (1969) · PubMed · Cited by 91
Prediction of heart transplant rejection with a breath test for markers of oxidative stress
Phillips, M., BOEHMER, J. P., Cataneo, R. N., Cheema, T., Eisen, H. J., Fallon, J. T., Fisher, P. E., Gass, A. L., Greenberg, J. H., KOBASHIGAWA, J. A., et al. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.08.052 · Cited by 54
Toxicokinetics of isoprene in rodents and humans
Filser, J. G., Csanády, G. A., Denk, B., Hartmann, M., Kaufmann, A., Kessler, W., Kreuzer, P. E., Pütz, C., Shen, J., & Stei, P. (1996) · Toxicology · doi:10.1016/0300-483x(96)03457-9 · Cited by 49
Cited by
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Self-citationAmann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Self-citationPeng, G., Hakim, M., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., Tisch, U., & Haick, H. (2010) · British Journal of Cancer · doi:10.1038/sj.bjc.6605810 · Cited by 775
Noninvasive detection of lung cancer by analysis of exhaled breath
Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Schwarz, K., Ligor, M., Ligor, T., Filipiak, W., Denz, H., Fiegl, M., et al. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-348 · Cited by 597
Self-citationNondestructive Sampling of Living Systems Using in Vivo Solid-Phase Microextraction
Ouyang, G., Vuckovic, D., & Pawliszyn, J. (2011) · Chemical Reviews · doi:10.1021/cr100203t · Cited by 426
Metadata
- Authors
- Ligor, M., Ligor, T., Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Denz, H., Fiegl, M., Hilbe, W., Weiss, W., Lukas, P., Jamnig, H., Hackl, M., Buszewski, B., Miekisch, W., Schubert, J., & Amann, A.
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 2009-01-01
- Volume
- 47
- Issue
- 5
- Pages
- 550-60
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W1987001230
- Cited by
- 262
- References
- 37
- FWCI
- 13.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.