The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Shortwave-infrared (SWIR) emitters for biological imaging: a review of challenges and opportunities
Open accessAbstract
Shortwave infrared radiation (SWIR) is the portion of the electromagnetic spectrum from approximately 900 nm to 2500 nm. Recent advances in imaging systems have expanded the application of SWIR emitters from traditional fields in materials science to biomedical imaging, and the new detectors in SWIR opened an opportunity of deep tissue imaging. Achieving deep photon penetration while maintaining high resolution is one of the main objectives and challenges in bioimaging used for the investigation of diverse processes in living organisms. The application of SWIR emitters in biological settings is, however, hampered by low quantum efficiency. So far, photoluminescent properties in the SWIR region have not been improved by extending concepts that have been developed for the visible (400–650 nm) and near-infrared (NIR, 700–900 nm) wavelengths, which indicates that the governing behavior is fundamentally different in the SWIR. The focus of this minireview is to examine the mechanisms behind the low efficiency of SWIR emitters as well as to highlight the progress in their design for biological applications. Several common mechanisms will be considered in this review: (a) the effect of the energy gap between the excited and ground state on the quantum efficiency, (b) the coupling of the excited electronic states in SWIR emitters to vibrational states in the surrounding matrix, and (c) the role of environment in quenching the excited states. General strategies to improve the quantum yields for a diverse type of SWIR emitters will be also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
The energy gap law for radiationless transitions in large molecules
Englman, R., & Jortner, J. (1970) · Molecular Physics · doi:10.1080/00268977000100171 · Cited by 2,778
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
A route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287
Welsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Brightening of carbon nanotube photoluminescence through the incorporation of sp3 defects
Piao, Y., Meany, B., Powell, L. R., Valley, N., Kwon, H., Schatz, G. C., & Wang, Y. (2013) · Nature Chemistry · doi:10.1038/nchem.1711 · Cited by 480
Cited by
Persistent luminescence instead of phosphorescence: History, mechanism, and perspective
Xu, J., & Tanabe, S. (2019) · Journal of Luminescence · doi:10.1016/j.jlumin.2018.09.047 · Cited by 680
Optical nano-agents in the second near-infrared window for biomedical applications
Cai, Y., Wei, Z., Song, C., Tang, C., Han, W., & Dong, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00494c · Cited by 603
Sheng, Z., Guo, B., Hu, D., Xu, S., Wu, W., Liew, W. H., Yao, K., Jiang, J., Liu, C., Zheng, H., et al. (2018) · Advanced Materials · doi:10.1002/adma.201800766 · Cited by 445
Flavylium Polymethine Fluorophores for Near‐ and Shortwave Infrared Imaging
Cosco, E. D., Caram, J. R., Bruns, O. T., Franke, D., Day, R. A., Farr, E. P., Bawendi, M. G., & Sletten, E. M. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201706974 · Cited by 415
Cosco, E. D., Spearman, A. L., Ramakrishnan, S., Lingg, J. G. P., Saccomano, M., Pengshung, M., Arús, B. A., Wong, K. C. Y., Glasl, S., Ntziachristos, V., et al. (2020) · Nature Chemistry · doi:10.1038/s41557-020-00554-5 · Cited by 337
Metadata
- Authors
- Thimsen, E., Sadtler, B., & Berezin, M. Y.
- Venue
- Nanophotonics
- Publisher
- Walter de Gruyter GmbH
- Published
- 2017-06-29
- Volume
- 6
- Issue
- 5
- Pages
- 1043-1054
- ISSN
- 2192-8606 (ISSN-L)
- 2192-8614
- OpenAlex
- W2726678465
- Cited by
- 208
- References
- 6
- FWCI
- 6.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Shortwave-infrared (SWIR) emitters for biological imaging: a review of challenges and opportunities. https://app.cochat.ai/papers/10.1515/nanoph-2017-0039
- The paper
- Thimsen, E., Sadtler, B., & Berezin, M. Y. (2017). Shortwave-infrared (SWIR) emitters for biological imaging: a review of challenges and opportunities. Nanophotonics. https://doi.org/10.1515/nanoph-2017-0039
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.