Eudragit®: a technology evaluation
The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: Eudragit is the brand name for a diverse range of polymethacrylate-based copolymers. It includes anionic, cationic, and neutral copolymers based on methacrylic acid and methacrylic/acrylic esters or their derivatives. AREAS COVERED: In this review, the physicochemical characteristics and applications of different grades of Eudragit in colon-specific/enteric-coated/sustained release drug delivery and taste masking have been addressed. EXPERT OPINION: Eudragits are amorphous polymers having glass transition temperatures between 9 to > 150(o)C. Eudragits are non-biodegradable, nonabsorbable, and nontoxic. Anionic Eudragit L dissolves at pH > 6 and is used for enteric coating, while Eudragit S, soluble at pH > 7 is used for colon targeting. Studies in human volunteers have confirmed that pH drops from 7.0 at terminal ileum to 6.0 at ascending colon, and Eudragit S based systems sometimes fail to release the drug. To overcome the shortcoming, combination of Eudragit S and Eudragit L which ensures drug release at pH < 7 has been advocated. Eudragit RL and RS, having quaternary ammonium groups, are water insoluble, but swellable/permeable polymers which are suitable for the sustained release film coating applications. Cationic Eudragit E, insoluble at pH ≥ 5, can prevent drug release in saliva and finds application in taste masking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Pharmaceutical Excipients
Rowe, R. C., Sheskey, P. J., & Quinn, M. E. (1994) · Cited by 3,493
Measurement of gastrointestinal pH profiles in normal ambulant human subjects
Evans, D. F., Pye, G., Bramley, R., Clark, A. G., Dyson, T. J., & Hardcastle, J. D. (1988) · Gut · doi:10.1136/gut.29.8.1035 · Cited by 1,240 · cited 1×
“0) [28] (though it has been reported that pH drops slightly in colon and is highest in ileocecal junction [29]).”
Pharmaceutical Applications of Hot-Melt Extrusion: Part I
Crowley, M. M., Zhang, F., Repka, M. A., Thumma, S., Upadhye, S. B., Kumar Battu, S., McGinity, J. W., & Martin, C. (2007) · Drug Development and Industrial Pharmacy · doi:10.1080/03639040701498759 · Cited by 824
Handbook of Pharmaceutical Excipients
Kibbe, A. H. (2003) · Medical Entomology and Zoology · Cited by 713
NUGENT, S. G., KUMAR, D., RAMPTON, D. S., & EVANS, D. F. (2001) · Gut · doi:10.1136/gut.48.4.571 · Cited by 700
Aqueous Polymeric Coatings for Pharmaceutical Dosage Forms
(2016) · CRC Press eBooks · doi:10.1201/9781315369938 · Cited by 492
A pH-dependent colon targeted oral drug delivery system using methacrylic acid copolymers
Khan, M. Z. I., Prebeg, Ž., & Kurjaković, N. (1999) · Journal of Controlled Release · doi:10.1016/s0168-3659(98)00151-5 · Cited by 325
Enteric coated HPMC capsules designed to achieve intestinal targeting
Cole, E. T., Scott, R. A., Connor, A. L., Wilding, I. R., Petereit, H.-U., Schminke, C., Beckert, T., & Cadé, D. (2002) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(01)00871-7 · Cited by 240
Pharmaceutical Dosage Forms - Tablets: Unit Operations and Mechanical Properties
(2008) · CRC Press eBooks · doi:10.3109/9781420020281 · Cited by 224
Watts, P. J., & Lllum, L. (1997) · Drug Development and Industrial Pharmacy · doi:10.3109/03639049709148695 · Cited by 209
Cited by
3D printing in pharmaceutics: A new tool for designing customized drug delivery systems
Goole, J., & Amighi, K. (2016) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2015.12.071 · Cited by 660
PLGA: a Unique Polymer for Drug Delivery
Kapoor, D. N., Bhatia, A., Kaur, R., Sharma, R., Kaur, G., & Dhawan, S. (2015) · Therapeutic Delivery · doi:10.4155/tde.14.91 · Cited by 609
Biomaterial-based antimicrobial therapies for the treatment of bacterial infections
Kalelkar, P. P., Riddick, M., & García, A. J. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00362-4 · Cited by 548
Nanoparticles for oral delivery: Design, evaluation and state-of-the-art
Date, A. A., Hanes, J., & Ensign, L. M. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.06.016 · Cited by 539
Hua, S. (2020) · Frontiers in Pharmacology · doi:10.3389/fphar.2020.00524 · Cited by 527
Advances in Oral Drug Delivery Systems: Challenges and Opportunities
Lou, J., Duan, H., Qin, Q., Teng, Z., Gan, F., Zhou, X., & Zhou, X. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15020484 · Cited by 397
Intestinal permeation enhancers for oral peptide delivery
Maher, S., Mrsny, R. J., & Brayden, D. J. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.06.005 · Cited by 381
Ionic liquids for oral insulin delivery
Banerjee, A., Ibsen, K., Brown, T., Chen, R., Agatemor, C., & Mitragotri, S. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1722338115 · Cited by 378
Azad, M. A., Olawuni, D., Kimbell, G., Badruddoza, A. Z. M., Hossain, M. S., & Sultana, T. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12020124 · Cited by 356
Revisiting structure-property relationship of pH-responsive polymers for drug delivery applications
Bazban-Shotorbani, S., Hasani-Sadrabadi, M. M., Karkhaneh, A., Serpooshan, V., Jacob, K. I., Moshaverinia, A., & Mahmoudi, M. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.02.021 · Cited by 342
Electrospun Fibrous Architectures for Drug Delivery, Tissue Engineering and Cancer Therapy
Ding, Y., Li, W., Zhang, F., Liu, Z., Zanjanizadeh Ezazi, N., Liu, D., & Santos, H. A. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201802852 · Cited by 312
Personalised 3D Printed Medicines: Which Techniques and Polymers Are More Successful?
Konta, A., García-Piña, M., & Serrano, D. (2017) · Bioengineering · doi:10.3390/bioengineering4040079 · Cited by 301
Colonic drug delivery: Formulating the next generation of colon-targeted therapeutics
McCoubrey, L. E., Favaron, A., Awad, A., Orlu, M., Gaisford, S., & Basit, A. W. (2023) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.12.029 · Cited by 232
“Eudragit ® S is a synthetic copolymer composed of poly (methacrylic acid, methyl methacrylate) at a ratio of 1:2 that dissolves when intestinal pH exceeds 7.0 [37].”
BackgroundInfluentialNovel nano-encapsulated probiotic agents: Encapsulate materials, delivery, and encapsulation systems
Xu, C., Ban, Q., Wang, W., Hou, J., & Jiang, Z. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.06.061 · Cited by 225
Polymer-based carriers for ophthalmic drug delivery
Imperiale, J. C., Acosta, G. B., & Sosnik, A. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2018.06.031 · Cited by 175
Enteric coating of oral solid dosage forms as a tool to improve drug bioavailability
Maderuelo, C., Lanao, J. M., & Zarzuelo, A. (2019) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2019.105019 · Cited by 147
Yildirimer, L., & Seifalian, A. M. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2014.04.014 · Cited by 98
“This may suggest an inherently passive nature of particle release which is true for many commercialised drug delivery platforms (Rujivipat and Bodmeier, 2010; Thakral et al., 2013).”
BackgroundGastrointestinal synthetic epithelial linings
Li, J., Wang, T., Kirtane, A. R., Shi, Y., Jones, A., Moussa, Z., Lopes, A., Collins, J., Tamang, S. M., Hess, K., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.abc0441 · Cited by 70
Metadata
- Authors
- Thakral, S., Thakral, N. K., & Majumdar, D. K.
- Venue
- Expert Opinion on Drug Delivery
- Publisher
- Informa Healthcare
- Published
- 2012-10-26
- Volume
- 10
- Issue
- 1
- Pages
- 131-149
- ISSN
- 1742-5247 (ISSN-L)
- 1744-7593
- OpenAlex
- W2081056194
- Cited by
- 458
- References
- 54
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.