Continuous Subcutaneous Glucose Monitoring Improved Metabolic Control in Pediatric Patients With Type 1 Diabetes: A Controlled Crossover Study
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Objective. To improve metabolic control and prevent complications, both acute and late, we need to adjust treatment on the basis of the blood glucose (BG) profile, as not even the most active BG self-monitoring gives sufficient information. Design. We have used Continuous Glucose Monitoring System (CGMS; Medtronic MiniMed, Northridge, CA) in a controlled crossover study including 27 diabetic patients aged 12.5 ± 3.3 (mean; standard deviation; range: 5–19) years. All patients were treated with intensive insulin therapy, 14 with multiple injections, and 13 with pumps. The patients were randomized into an open or blind study arm. Both arms wore the CGMS sensor for 3 days every 2 weeks. CGMS profiles were used in the open study arm to adjust insulin therapy at follow-up visits every 6 weeks. Both the patients and the diabetes team were masked to the CGMS profiles in the blinded arm, and insulin therapy adjustments were based solely on 7-point BG profiles performed by the patients. At 3 months the 2 study arms were crossed over. Results. Despite initial problems with a device new to both patients and the diabetes team, hemoglobin A1C decreased significantly in the open arm (from 7.70%–7.31%) but not in the blind arm (7.75%–7.65%). A total of 26/27 patients experienced daytime low subcutaneous glucose (<3.0 mmol/L; .8 episodes/day; duration 58 ± 29 minutes; 5.5% of total time), and 27/27 patients had at least 1 nocturnal episode of low subcutaneous glucose (.4 episodes/night; duration 132 ± 81 minutes; 10.1% of total time). Conclusions. Use of CGMS facilitated an improved treatment, and patients received new insight and increased motivation. In this study, we found CGMS to be a useful tool for education and improving metabolic control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Danne, T., Mortensen, H. B., Hougaard, P., Lynggaard, H., Aanstoot, H.-J., Chiarelli, F., Daneman, D., Dorchy, H., Garandeau, P., Greene, S. A., et al. (2001) · Diabetes Care · doi:10.2337/diacare.24.8.1342 · Cited by 299
Bode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232
A Pilot Study of the Continuous Glucose Monitoring System
Kaufman, F. R., Gibson, L. C., Halvorson, M., Carpenter, S., Fisher, L. K., & Pitukcheewanont, P. (2001) · Diabetes Care · doi:10.2337/diacare.24.12.2030 · Cited by 224
Cited by
6. Glycemic Targets: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s006 · Cited by 1,403
6. Glycemic Targets: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s006 · Cited by 847
6. Glycemic Targets: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s006 · Cited by 744
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
6. Glycemic Targets: Standards of Care in Diabetes—2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s006 · Cited by 684
Goldstein, D. E., Little, R. R., Lorenz, R. A., Malone, J. I., Nathan, D., Peterson, C. M., & Sacks, D. B. (2004) · Diabetes Care · doi:10.2337/diacare.27.7.1761 · Cited by 625
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
Misso, M. L., Egberts, K. J., Page, M., O'Connor, D., & Shaw, J. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005103.pub2 · Cited by 406
The Evidence for Medical Nutrition Therapy for Type 1 and Type 2 Diabetes in Adults
Franz, M. J., Powers, M. A., Leontos, C., Holzmeister, L. A., Kulkarni, K., Monk, A., Wedel, N., & Gradwell, E. (2010) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2010.09.014 · Cited by 306
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
The Effect of Real-Time Continuous Glucose Monitoring in Pregnant Women With Diabetes
Secher, A. L., Ringholm, L., Andersen, H. U., Damm, P., & Mathiesen, E. R. (2013) · Diabetes Care · doi:10.2337/dc12-2360 · Cited by 214
Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
O’Connell, M. A., Donath, S., O’Neal, D. N., Colman, P. G., Ambler, G. R., Jones, T. W., Davis, E. A., & Cameron, F. J. (2009) · Diabetologia · doi:10.1007/s00125-009-1365-0 · Cited by 211
“Use of these devices to initiate focused therapeutic changes has been studied extensively with some [1–4], but not all [5, 6] studies reporting improvements in overall glycaemic control.”
BackgroundISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Poolsup, N., Suksomboon, N., & Kyaw, A. M. (2013) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-5-39 · Cited by 179
“One study that was included in the previous meta-analysis was excluded from ours because participants were older than 18 years [37].”
BackgroundPsycho‐educational interventions for children and young people with Type 1 diabetes
Murphy, H. R., Rayman, G., & Skinner, T. C. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2006.01816.x · Cited by 177
Prevention of Nocturnal Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension
Buckingham, B., Chase, H. P., Dassau, E., Cobry, E., Clinton, P., Gage, V., Caswell, K., Wilkinson, J., Cameron, F., Lee, H., et al. (2010) · Diabetes Care · doi:10.2337/dc09-2303 · Cited by 169
“frequencies of nocturnal biochemical hypoglycemia have been found in other studies (6-9).”
BackgroundBailey, T. S., Zisser, H. C., & Garg, S. K. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0205 · Cited by 159
Experience with the Continuous Glucose Monitoring System® in a Medical Intensive Care Unit
Goldberg, P. A., Siegel, M. D., Russell, R. R., Sherwin, R. S., Halickman, J. I., Cooper, D. A., Dziura, J. D., & Inzucchi, S. E. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198034 · Cited by 158
Glycemic Characteristics in Continuously Monitored Patients With Type 1 and Type 2 Diabetes
Bode, B. W., Schwartz, S., Stubbs, H. A., & Block, J. E. (2005) · Diabetes Care · doi:10.2337/diacare.28.10.2361 · Cited by 137
Assessment and management of hypoglycemia in children and adolescents with diabetes
Clarke, W., Jones, T., Rewers, A., Dunger, D., & Klingensmith, G. J. (2009) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2009.00583.x · Cited by 135
“at least one nocturnal episode of low subcutaneous glucose (65).”
BackgroundChetty, V. T., Almulla, A., Odueyungbo, A., & Thabane, L. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.02.014 · Cited by 85
“The seven included articles were published in different countries: three studies in the USA [28–30], one in Germany [31], one in Spain [32], one in Sweden [33] and one in Australia [34].”
BackgroundMethodInfluentialGarg, S. K., Voelmle, M. K., Beatson, C. R., Miller, H. A., Crew, L. B., Freson, B. J., & Hazenfield, R. M. (2011) · Diabetes Care · doi:10.2337/dc10-1852 · Cited by 85
Improved Real-World Glycemic Control With Continuous Glucose Monitoring System Predictive Alerts
Abraham, S. B., Arunachalam, S., Zhong, A., Agrawal, P., Cohen, O., & McMahon, C. M. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819859334 · Cited by 63
Cosson, E., Hamo-Tchatchouang, E., Dufaitre-Patouraux, L., Attali, J.-R., Pariès, J., & Schaepelynck-Bélicar, P. (2009) · Diabetes & Metabolism · doi:10.1016/j.diabet.2009.02.006 · Cited by 57
Kim, S. K., Kim, H. J., Kim, T., Hur, K. Y., Kim, S. W., Lee, M.-K., Min, Y.-K., Kim, K.-W., Chung, J. H., & Kim, J. H. (2014) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2014.38.6.449 · Cited by 23
“Several studies have reported that therapeutic adjustments based on CGM data are associated with improvement in HbA1c levels and reduction in hypoglycemia [8,9].”
Background
Metadata
- Authors
- Ludvigsson, J., & Hanas, R.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2003-05-01
- Volume
- 111
- Issue
- 5
- Pages
- 933-938
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2032680655
- Cited by
- 228
- References
- 4
- FWCI
- 11.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.