Stereological tools in biomedical research
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
Stereological studies are more and more frequent in literature, particularly in the development/evolution, pathology, and neurosciences areas. The stereology challenge is to understand the structural inner threedimensional arrangement based on the analysis of the structure slices only showing two-dimensional information. Cavalieri and Scherle's methods to estimate volume, and Buffon's needle problem, are commented in the stereological context. A group of actions is needed to appropriately quantify morphological structures (unbiased and reproducibly), e.g. sampling, isotropic and uniform randomly sections (Delesse's principle), and updated stereological tools (disector, fractionator, nucleator, etc). Through the correct stereology use, a quantitative study with little effort could be performed: efficiency in stereology means a minimum slices sample counting (little work), low cost (slices preparation), but good accuracy. In the present text, a short review of the main stereological tools is done as a background basis to non-expert scientists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of nuclear population from microtome sections
Abercrombie, M. (1946) · The Anatomical Record · doi:10.1002/ar.1090940210 · Cited by 4,363 · cited 1×
“In the last 50 years, stereological studies have appeared in literature more and more frequently, the first studies being based on pioneers (Chalkley 1943, Abercrombie 1946, Chalkley et al. 1949, Weibel and Gomez 1962, Weibel et al. 1966).”
BackgroundWest, M. J., Slomianka, L., & Gundersen, H. J. G. (1991) · The Anatomical Record · doi:10.1002/ar.1092310411 · Cited by 2,994
GUNDERSEN, H. J. G., BENDTSEN, T. F., KORBO, L., MARCUSSEN, N., MØLLER, A., NIELSEN, K., NYENGAARD, J. R., PAKKENBERG, B., SØRENSEN, F. B., VESTERBY, A., et al. (1988) · APMIS · doi:10.1111/j.1699-0463.1988.tb05320.x · Cited by 2,929
The unbiased estimation of number and sizes of arbitrary particles using the disector
Sterio, D. C. (1984) · Journal of Microscopy · doi:10.1111/j.1365-2818.1984.tb02501.x · Cited by 2,519
Gundersen, H. J. G., Bagger, P., Bendtsen, T. F., Evans, S. M., Korbo, L., Marcussen, N., MØLler, A., Nielsen, K., Nyengaard, J. R., Pakkenberg, B., et al. (1988) · APMIS · doi:10.1111/j.1699-0463.1988.tb00954.x · Cited by 2,478
Stereological Methods. Practical methods for biological morphometry
Weibel, E. R. (1979) · Academic Press eBooks · Cited by 1,994
PRACTICAL STEREOLOGICAL METHODS FOR MORPHOMETRIC CYTOLOGY
Weibel, E. R., Kistler, G. S., & Scherle, W. F. (1966) · The Journal of Cell Biology · doi:10.1083/jcb.30.1.23 · Cited by 1,826
Practical methods for biological morphometry
Weibel, E. R. (1979) · Academic Press eBooks · Cited by 1,563
The efficiency of systematic sampling in stereology—reconsidered
GUNDERSEN, H. J. G., JENSEN, E. B. V., KIÊU, K., & NIELSEN, J. (1999) · Journal of Microscopy · doi:10.1046/j.1365-2818.1999.00457.x · Cited by 1,317 · cited 1×
“…finally, the need of low-cost equipment (but a high-standing equipment like a confocal laser scanning microscope is welcome ) (Bolender 1981, 1982, Gundersen et al. 1999, Bjarkam et al. 2001, Kubinova and Janacek 2001, Kubinova et al. 2001, Pereira and Mandarim-de- Lacerda 2002, Charleston et al.…”
BackgroundNotes on the estimation of the numerical density of arbitrary profiles: the edge effect
Gundersen, H. J. G. (1977) · Journal of Microscopy · doi:10.1111/j.1365-2818.1977.tb00062.x · Cited by 1,275
Unbiased Stereology: Three-Dimensional Measurement in Microscopy
Howard, C. V., & Reed, M. (1998) · Cited by 1,149
Estimation of surface area from vertical sections
Baddeley, A. J., Gundersen, H. J. G., & Cruz‐Orive, L. M. (1986) · Journal of Microscopy · doi:10.1111/j.1365-2818.1986.tb04282.x · Cited by 1,058
A simple method for volumetry of organs in quantitative stereology.
Scherle, W. F. (1970) · PubMed · Cited by 1,047
Method for the Quantitative Morphologic Analysis of Tissues
(1943) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/4.1.47 · Cited by 961
SANDAU, K. (1999) · Journal of Microscopy · doi:10.1046/j.1365-2818.1999.0429a.x · Cited by 890
Glomerular number and size in relation to age, kidney weight, and body surface in normal man
Nyengaard, J. R., & Bendtsen, T. F. (1992) · The Anatomical Record · doi:10.1002/ar.1092320205 · Cited by 879
A principle for counting tissue structures on random sections
Weibel, E. R., & Gomez, D. M. (1962) · Journal of Applied Physiology · doi:10.1152/jappl.1962.17.2.343 · Cited by 833
Optimizing sampling efficiency of stereological studies in biology: or ‘Do more less well!‘
Gundersen, H. J. G., & ØSterby, R. (1981) · Journal of Microscopy · doi:10.1111/j.1365-2818.1981.tb01199.x · Cited by 534
Recent stereological methods for cell biology: a brief survey
Cruz-Orive, L. M., & Weibel, E. R. (1990) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.1990.258.4.l148 · Cited by 506
Pakkenberg, B. (2003) · Experimental Gerontology · doi:10.1016/s0531-5565(02)00151-1 · Cited by 485 · cited 1×
“…the development (Mandarim-de-Lacerda 1991a, b, Almeida and Mandarim-de-Lacerda 2002), aging process (Duffell et al. 2000, Aguila and Mandarim-de-Lacerda 2001, Pakkenberg et al. 2003), and pathological diagnosis (Elias et al. 1981, Collan 1985, Hamilton and Allen 1995, Collan 1997, Hof et al. 2003).”
BackgroundGundersen, H. J. G. (1988) · Journal of Microscopy · doi:10.1111/j.1365-2818.1988.tb04609.x · Cited by 448
Michel, R. P., & Cruz‐Orive, L. M. (1988) · Journal of Microscopy · doi:10.1111/j.1365-2818.1988.tb04603.x · Cited by 431
Principles and Practices of Unbiased Stereology: An Introduction for Bioscientists
Mouton, P. R. (2002) · Cited by 398
Estimation of surface area and length with the orientator
Mattfeldt, T., Mall, G., Gharehbaghi, H., & Möller, P. (1990) · Journal of Microscopy · doi:10.1111/j.1365-2818.1990.tb03036.x · Cited by 376
Mayhew, T. M., & Gundersen, H. J. G. (1996) · PubMed Central · Cited by 358
Pakkenberg, B., & Gundersen, H. J. G. (1988) · Journal of Microscopy · doi:10.1111/j.1365-2818.1988.tb04582.x · Cited by 347
A review of recent advances in stereology for quantifying neural structure
Mayhew, T. M. (1992) · Journal of Neurocytology · doi:10.1007/bf01191700 · Cited by 330
The benefit of stereology for quantitative radiology.
Roberts, N., Puddephat, M. J., & McNulty, V (2000) · The British Journal of Radiology · doi:10.1259/bjr.73.871.11089458 · Cited by 248
A Guide to Practical Stereology
Elias, H., & Hyde, D. M. (1983) · KARGER eBooks · doi:10.1159/isbn.978-3-8055-3466-6 · Cited by 213
Extending Unbiased Stereology of Brain Ultrastructure to Three-dimensional Volumes
Fiala, J. C., & Harris, K. M. (2001) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.2001.0080001 · Cited by 203
Stereological length estimation using spherical probes
Mouton, P. R., Gokhale, A. M., Ward, N. L., & West, M. J. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01006.x · Cited by 202
A Guide to Practical Stereology
Williams, M. A. (1984) · Europe PMC (PubMed Central) · Cited by 164
Gardella, D., Hatton, W. J., Rind, H. B., Rosen, G. D., & von Bartheld, C. S. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00363-1 · Cited by 152
Measuring through the microscope: Development and evolution of stereological methods
Weibel, E. R. (1989) · Journal of Microscopy · doi:10.1111/j.1365-2818.1989.tb02898.x · Cited by 126
Hansen, S., Grabau, D., Rose, C., Bak, M., & Sørensen, F. B. (1998) · PubMed · Cited by 124
Mattfeldt, T., Möbius, H. ‐., & Mall, G. (1985) · Journal of Microscopy · doi:10.1111/j.1365-2818.1985.tb02644.x · Cited by 111
von Bartheld, C. S. (2002) · PubMed · doi:10.14670/hh-17.639 · Cited by 90
Hof, P. R., Bussière, T., Gold, G., Kövari, E., Giannakopoulos, P., Bouras, C., Perl, D. P., & Morrison, J. H. (2003) · Journal of Neuropathology & Experimental Neurology · doi:10.1093/jnen/62.1.55 · Cited by 85
Kubínová, L., & Janáček, J. (2001) · Microscopy Research and Technique · doi:10.1002/jemt.1112 · Cited by 60
Numerical Density of Cardiomyocytes in Chronic Nitric Oxide Synthesis Inhibition
Mandarim‐de‐Lacerda, C. A., & Pereira, L. M. M. (2000) · Pathobiology · doi:10.1159/000028113 · Cited by 51
Self-citationStereological quantitation in cerebella from people with schizophrenia
Andersen, B. B., & Pakkenberg, B. (2003) · British Journal of Psychiatry · doi:10.1192/bjp.182.4.354 · Cited by 47
Bendtsen, T. F., & Nyengaard, J. R. (1989) · Journal of Microscopy · doi:10.1111/j.1365-2818.1989.tb01470.x · Cited by 47
Morphometric Analysis of the Developing Rat Brain
Duffell, S., Soames, A. R., & Gunby, S. (2000) · Toxicologic Pathology · doi:10.1177/019262330002800120 · Cited by 36
Objective malignancy grading: A review emphasizing unbiased stereology applied to breast tumors
Ladekarl, M. B. (1998) · Apmis · doi:10.1111/j.1600-0463.1998.tb05620.x · Cited by 32
Precision of circular systematic sampling
Cruz-Orive, L. M., & Gual-Arnau, X. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01057.x · Cited by 27
Stereologic study of the sinoatrial node of rats – age related changes
de Melo, S. R., de Souza, R. R., & Mandarim‐de‐Lacerda, C. A. (2002) · Biogerontology · doi:10.1023/a:1021376002896 · Cited by 24
Self-citationInfluence of the chronic nitric oxide synthesis inhibition on cardiomyocytes number
Pessanha, M. G., & Mandarim‐de‐Lacerda, C. A. (2000) · Archiv für Pathologische Anatomie und Physiologie und für Klinische Medicin · doi:10.1007/s004280000276 · Cited by 24
Self-citationObjective malignancy grading: a review emphasizing unbiased stereology applied to breast tumors.
Ladekarl, M. B. (1998) · PubMed · Cited by 23
Baddeley, A. J. (2001) · Trends in Neurosciences · doi:10.1016/s0166-2236(00)01833-6 · Cited by 22
Quantitative study of the myocardium in human embryos
Mandarim‐de‐Lacerda, C. A., dos Santos, M. B., & Pessanha, M. G. (1995) · Annals of Anatomy - Anatomischer Anzeiger · doi:10.1016/s0940-9602(11)80071-3 · Cited by 14
Self-citationMandarim‐de‐Lacerda, C. A., & Costa, W. S. (1993) · Annals of Anatomy - Anatomischer Anzeiger · doi:10.1016/s0940-9602(11)80243-8 · Cited by 12
Self-citationCharleston, L. B., Thyer, A., Klein, N. A., Soules, M. R., & Charleston, J. S. (2003) · Journal of Histotechnology · doi:10.1179/his.2003.26.1.49 · Cited by 9
Stereology of the myocardium in two species of Callithrix (Callitrichidae, Primates)
Burity, C. H. D. F., Mandarim‐de‐Lacerda, C. A., & Pissinatti, A. (1996) · Annals of Anatomy - Anatomischer Anzeiger · doi:10.1016/s0940-9602(96)80134-8 · Cited by 9
Self-citationDavey, M. G., Hedrick, H. L., Bouchard, S., Adzick, N. S., Flake, A. W., & Doolin, E. J. (2003) · Scanning · doi:10.1002/sca.4950250108 · Cited by 9
Cited by
Fraulob, J. C., Ogg-Diamantino, R., Fernandes-Santos, C., Aguila, M. B., & Mandarim-de-Lacerda, C. A. (2010) · Journal of Clinical Biochemistry and Nutrition · doi:10.3164/jcbn.09-83 · Cited by 448
Self-citationVICENTINI, F., SIMI, T., DELCIAMPO, J., WOLGA, N., PITOL, D., IYOMASA, M., BENTLEY, M., & FONSECA, M. (2008) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2008.01.012 · Cited by 196
Insulin receptor substrate signaling suppresses neonatal autophagy in the heart
Riehle, C., Wende, A. R., Sena, S., Pires, K. M., Pereira, R. O., Zhu, Y., Bugger, H., Frank, D., Bevins, J., Chen, D., et al. (2013) · Journal of Clinical Investigation · doi:10.1172/jci71171 · Cited by 114
“Stained slides were analyzed with a 36-point test system, and stereology was performed as previously described (53).”
Oliveira‐da‐Silva, A., Vieira, F. B., Cristina‐Rodrigues, F., Filgueiras, C. C., Manhães, A. C., & Abreu‐Villaça, Y. (2009) · International Journal of Developmental Neuroscience · doi:10.1016/j.ijdevneu.2009.06.009 · Cited by 60
“This method is considered an unbiased and efficient cell counting method by several authors (Gardella et al., 2003; Mandarin-de-Lacerda, 2003).”
MethodGuardado Mendoza, R., Perego, C., Finzi, G., La Rosa, S., Capella, C., Jimenez-Ceja, L. M., Velloso, L. A., Saad, M. J. A., Sessa, F., Bertuzzi, F., et al. (2015) · Diabetologia · doi:10.1007/s00125-015-3625-5 · Cited by 41
“0 system (Olympus, Ballerup, Denmark) was used to perform all the microscopic measurements of beta, alpha and delta cell and amyloid deposit volume using the stereology fundamentals previously described and validated [31, 33–35].”
Metadata
- Authors
- Mandarim-de-Lacerda, C. A.
- Venue
- Anais da Academia Brasileira de Ciências
- Publisher
- FapUNIFESP (SciELO)
- Published
- 2003-12
- Volume
- 75
- Issue
- 4
- Pages
- 469-486
- ISSN
- 0001-3765 (ISSN-L)
- OpenAlex
- W2147517074
- Cited by
- 595
- References
- 54
- FWCI
- 28.39
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.