Comparison of sweat rate during graded exercise and the local rate induced by pilocarpine
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Centrally stimulated sweat rate produced by graded exercise until exhaustion was compared to the local sweat rate induced by pilocarpine, often used as a sweating index for healthy individuals. Nine young male volunteers (22 +/- 4 years) were studied in temperate environment in two situations: at rest and during progressive exercise with 25 W increases every 2 min until exhaustion, on a cycle ergometer. In both situations, sweating was induced on the right forearm with 5 ml 0.5% pilocarpine hydrochloride applied by iontophoresis (1.5 mA, 5 min), with left forearm used as control. Local sweat rate was measured for 15 min at rest. During exercise, whole-body sweat rate was calculated from the body weight variation. Local sweat rate was measured from the time when heart rate reached 150 bpm until exhaustion and was collected using absorbent filter paper. Pharmacologically induced local sweat rate at rest (0.4 +/- 0.2 mg cm-2 min-1) and mean exercise-induced whole-body sweat rate (0.4 +/- 0.1 mg cm-2 min-1) were the same (P > 0.05) but were about five times smaller than local exercise-induced sweat rate (control = 2.1 +/- 1.4; pilocarpine = 2.7 +/- 1.2 mg cm-2 min-1), indicating different sudorific mechanisms. Both exercise-induced whole-body sweat rate (P < 0.05) and local sweat rate (P < 0.05) on control forearm correlated positively with pilocarpine-induced local sweat rate at rest. Assuming that exercise-induced sweating was a result of integrated physiological mechanisms, we suggest that local and whole-body sweat rate measured during graded exercise could be a better sweating index than pilocarpine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Assuming a single-centred flow model13, the best-case sampling interval can be calculated to be less than 1 min, based on the sweat rate (~3–4 mg min−1 cm−2)39 and the pad size (1.5 cm × 2 cm × 50 μm).”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [39]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Forearm sweating rate has been reported to be higher with exercise and/or thermal stress compared with pilocarpine iontophoresis (Hjortskov et al. 1995; Vimieiro-Gomes et al. 2005).”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Vimieiro-Gomes et al. 2005
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2014) · Medical Entomology and Zoology · Cited by 9,400
A formula to estimate the approximate surface area if height and weight be known. 1916.
Bois, D. D., & Bois, E. F. D. (1989) · PubMed · Cited by 5,706
A new weighting system for mean surface temperature of the human body
Ramanathan, N. L. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.3.531 · Cited by 1,883
Gibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434 · cited 2×
“5 mA, 60 μA cm-2, 5 min) as described by Gibson and Cooke (12) and Buono and Sjoholm (3).”
MethodInfluentialReflex control of the circulation during exercise: chemoreflexes and mechanoreflexes
Rowell, L. B., & O'Leary, D. S. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.69.2.407 · Cited by 725 · cited 3×
“This HR was chosen to permit the observation of sweating during a phase of the exercise when the sympathetic nervous system is activated (10).”
BackgroundMethodBiology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717 · cited 2×
“Thus, sweat production is essential for heat tolerance, which prevents hyperthermia and influences performance during physical activity (1).”
BackgroundImportance of skin temperature in the regulation of sweating.
Nadel, E. R., Bullard, R. W., & Stolwijk, J. A. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.1.80 · Cited by 545 · cited 1×
“Hypothalamic stimuli increase sweat production, which is proportional to the internal body temperature (as a result of body metabolism) and skin temperature (as a result of thermal environmental stress) (15,16).”
BackgroundPeripheral modifications to the central drive for sweating
Nadel, E. R., Mitchell, J. W., Saltin, B., & Stolwijk, J. A. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.6.828 · Cited by 234
Acute and adaptive responses in humans to exercise in a warm, humid environment
Nielsen, B., Strange, S., Christensen, N. J., Warberg, J., & Saltin, B. (1997) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/s004240050361 · Cited by 228
Armstrong, L. E., Maresh, C. M., Gabaree, C. V., Hoffman, J. R., Kavouras, S. A., Kenefick, R. W., Castellani, J. W., & Ahlquist, L. E. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.6.2028 · Cited by 201 · cited 1×
“Sweat production stimulated by the sympathetic system has been measured during prolonged exercise and/or exposure to different thermal environments to evaluate the acclimation status and to establish rehydration protocols according to water losses caused by sweating (7-9).”
BackgroundEffect of hyperosmolality on control of blood flow and sweating
Fortney, S. M., Wenger, C. B., Bove, J. R., & Nadel, E. R. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.57.6.1688 · Cited by 194 · cited 1×
“Furthermore, exercise is known to induce higher concentrations of noradrenaline, adrenaline and vasoactive peptides (10) which might represent co-factors in the sudorific response (1), variations in plasma osmolality (20), greater local blood flow (21), and increased temperature in the periglandular region (16).”
BackgroundEffect of physical training on peripheral sweat production
Buono, M. J., & Sjoholm, N. T. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.65.2.811 · Cited by 185 · cited 3×
“5 mA, 60 μA cm-2, 5 min) as described by Gibson and Cooke (12) and Buono and Sjoholm (3).”
BackgroundMethodInfluentialKONDO, TAKANO, AOKI, SHIBASAKI, TOMINAGA, & INOUE (1998) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.1998.00407.x · Cited by 130 · cited 1×
“corroborates the known principle of universal sweating in response to central thermal stimuli (17) and may indicate that the forearm is an area effectively participating in sweat production during exercise, as reported in the literature (22-24).”
BackgroundThe Effects of Running, Weightlifting and a Combination of Both on Growth Hormone Release.
Craig, B. W., Lucas, J., Pohlman, R., & Stelling, H. (1991) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-199111000-00005 · Cited by 114
The topography of eccrine sweating in humans during exercise
Cotter, J. D., Patterson, M. J., & Taylor, N. A. S. (1995) · European Journal of Applied Physiology · doi:10.1007/bf00238559 · Cited by 106 · cited 1×
“corroborates the known principle of universal sweating in response to central thermal stimuli (17) and may indicate that the forearm is an area effectively participating in sweat production during exercise, as reported in the literature (22-24).”
BackgroundNon-Thermoregulatory Modulation of Sweating in Humans
Shibasaki, M., Kondo, N., & Crandall, C. G. (2003) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200301000-00007 · Cited by 78 · cited 1×
“Non-thermal stimuli such as certain emotional states and mental activities, the level of mental alertness and exercise-related factors (activation of central drive and muscle mechano- and metaboreceptors) also trigger sudorific responses immediately after stimulation, and these responses are dissociated from the varia…”
BackgroundPilocarpine-induced sweat gland function in individuals with multiple sclerosis
Davis, S. L., Wilson, T. E., Vener, J. M., Crandall, C. G., Petajan, J. H., & White, A. T. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00860.2004 · Cited by 75 · cited 1×
“The sweat rate induced by cholinergic agents is considered to reflect the maximal rate (2), and the sweat rate induced by pilocarpine at rest is regarded to be an objective index of sweat gland output and to reflect sweat production during continuous exercise (3-6).”
BackgroundSugenoya, J., Iwase, S., Mano, T., Sugiyama, Y., Ogawa, T., Nishiyama, T., Nishimura, N., & Kimura, T. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.603bt.x · Cited by 66 · cited 1×
“Furthermore, exercise is known to induce higher concentrations of noradrenaline, adrenaline and vasoactive peptides (10) which might represent co-factors in the sudorific response (1), variations in plasma osmolality (20), greater local blood flow (21), and increased temperature in the periglandular region (16).”
BackgroundResponses of sweating and body temperature to sinusoidal exercise
Yamazaki, F., Sone, R., & Ikegami, H. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.6.2541 · Cited by 42 · cited 1×
“Non-thermal stimuli such as certain emotional states and mental activities, the level of mental alertness and exercise-related factors (activation of central drive and muscle mechano- and metaboreceptors) also trigger sudorific responses immediately after stimulation, and these responses are dissociated from the varia…”
BackgroundGomes, A. C. V., Oswaldo, L., & Rodrigues, C. (2001) · Cited by 31
Pilocarpine iontophoresis test: an index of physiological sweat secretion?
Hjortskov, N., Jepsen, L. T., Nielsen, B., Juul, A., & Skakkebæk, N. E. (1995) · Clinical Physiology · doi:10.1111/j.1475-097x.1995.tb00530.x · Cited by 19 · cited 2×
“Furthermore, we assumed that exercise sweating stimulation (central) would be different in nature than the pilocarpine stimulation (local) (6).”
Background[38] Methods for studying eccrine sweat gland function in Vivo and in Vitro
Sato, K., & Sato, F. (1990) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/0076-6879(90)92096-v · Cited by 15 · cited 1×
“The sweat rate induced by cholinergic agents is considered to reflect the maximal rate (2), and the sweat rate induced by pilocarpine at rest is regarded to be an objective index of sweat gland output and to reflect sweat production during continuous exercise (3-6).”
BackgroundPilocarpine-induced Sweat Rate at Rest Versus Whole-body Sweat Rate During Exercise
Buono, M. J., White, C., & Connolly, K. P. (1991) · The Journal of Strength and Conditioning Research · doi:10.1519/00124278-199105000-00006 · Cited by 11
Evaluation of hydration status, thermal stress and energy cost during volleyball training sessions
Gomes, A. C. V., & Rodrigues, L. O. C. (2001) · Revista Paulista de Educação Física · doi:10.11606/issn.2594-5904.rpef.2001.139902 · Cited by 7
Self-citationLimb vs trunk sweat gland recruitment patterns during exercise in humans
Buono, M. J. (2000) · Journal of Thermal Biology · doi:10.1016/s0306-4565(99)00095-9 · Cited by 6 · cited 1×
“corroborates the known principle of universal sweating in response to central thermal stimuli (17) and may indicate that the forearm is an area effectively participating in sweat production during exercise, as reported in the literature (22-24).”
Background
Research works printed but not linked: 1
- American College of Sports Medicine (2000). Guidelines for Exer- cise Testing and Prescription. 6th edn. Lippincott Williams & Wilkins, Philadelphia, PA, USA.
Cited by
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
“Assuming a single-centred flow model 13 , the best-case sampling interval can be calculated to be less than 1 min, based on the sweat rate ( ∼ 3–4 mg min − 1 cm − 2 ) 39 and the pad size (1.5 cm × 2 cm × 50 µ m).”
BackgroundInfluentialPhysiology of sweat gland function: The roles of sweating and sweat composition in human health
Baker, L. B. (2019) · Temperature · doi:10.1080/23328940.2019.1632145 · Cited by 732
Baker, L. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0691-5 · Cited by 403
“Most notably, LSR is consistently higher with exercise and thermal stress compared with pilocarpine iontophoresis [19, 102, 103].”
BackgroundPhysiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
Eyeglasses based wireless electrolyte and metabolite sensor platform
Sempionatto, J. R., Nakagawa, T., Pavinatto, A., Mensah, S. T., Imani, S., Mercier, P., & Wang, J. (2017) · Lab on a Chip · doi:10.1039/c7lc00192d · Cited by 311
Metadata
- Authors
- Vimieiro-Gomes, A. C., Magalhães, F. C., Amorim, F. T., Machado-Moreira, C. A., Rosa, M. S., Lima, N. R. V., & Rodrigues, L. O. C.
- Affiliations
- Universidade Federal de Minas Gerais, Brasil
- Universidade Federal de Minas Gerais (BR)
- Venue
- Brazilian Journal of Medical and Biological Research
- Publisher
- FapUNIFESP (SciELO)
- Published
- 2005-07
- Volume
- 38
- Issue
- 7
- Pages
- 1133-1139
- ISSN
- 0100-879X (ISSN-L)
- OpenAlex
- W2074448281
- Cited by
- 49
- References
- 24
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 5 · 2023: 3 · 2022: 2 · 2021: 4 · 2020: 3 · 2019: 5 · 2018: 2 · 2017: 3 · 2016: 2 · 2015: 1 · 2013: 3 · 2012: 1
- FWCI
- 0.80
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Brazilian Journal of Medical and Biological Research (publishedVersion, cc-by)
- PubMed (publishedVersion)
- LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (publishedVersion, other-oa)
- Americanae (AECID Library) (submittedVersion, cc-by-nc)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Fundação de Amparo à Pesquisa do Estado de Minas Gerais
- Universidade Federal de Minas Gerais
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
- Keywords
- sweat rate, graded exercise, pilocarpine, local sweat rate, iontophoresis, exercise-induced sweating, thermoregulation
- MeSH terms
- Adult, Analysis of Variance, Body Temperature Regulation, Humans, Iontophoresis, Male, Pilocarpine, Sweating, Exercise, Muscarinic Agonists
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.