The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Consistent pattern of elevated symptoms in air-conditioned office buildings: a reanalysis of epidemiologic studies.
Open accessAbstract
Published studies of the relation between type of building ventilation system and work-related symptom prevalence in office workers have been contradictory. A reanalysis was performed of six studies meeting specific eligibility criteria, combining published data with unpublished information obtained from study authors. Five eligible studies were from the United Kingdom, and one was from Denmark. Standardized categories of building ventilation type were created to allow comparison of effects across studies. Within each study, prevalence odds ratios (PORs) were calculated for symptoms in each ventilation category relative to a baseline category of naturally ventilated buildings. Air-conditioned buildings were consistently associated with increased prevalence of work-related headache (POR = 1.3-3.1), lethargy (POR = 1.4-5.1), and upper respiratory/mucus membrane symptoms (POR = 1.3-4.8). Humidification was not a necessary factor for the higher symptom prevalence associated with air-conditioning. Mechanical ventilation without air-conditioning was not associated with higher symptom prevalence. The consistent associations found between type of building ventilation and reported symptom prevalence have potentially important public health and economic implications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Health Effects and Sources of Indoor Air Pollution. Part I
Samet, J. M., Marbury, M. C., & Spengler, J. D. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.6.1486 · Cited by 541
Indirect health effects of relative humidity in indoor environments.
Arundel, A. V., Sterling, E. M., Biggin, J. H., & Sterling, T. D. (1986) · Environmental Health Perspectives · doi:10.1289/ehp.8665351 · Cited by 525
Publication Bias and Dissemination of Clinical Research
Begg, C. B., & Berlin, J. A. (1989) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/81.2.107 · Cited by 440
SICK BUILDING SYNDROME: A STUDY OF 4373 OFFICE WORKERS
(1987) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/31.4a.493 · Cited by 416
The sick building syndrome: prevalence studies.
Finnegan, M. J., Pickering, C. A., & Burge, P. S. (1984) · BMJ · doi:10.1136/bmj.289.6458.1573 · Cited by 373
The “sick” building syndrome in the office environment: The Danish town hall study
Skov, P., Valbjørn, O., & DISG (1987) · Environment International · doi:10.1016/0160-4120(87)90190-5 · Cited by 233
Skov, P., Valbjorn, O., & Pedersen, B. V. (1989) · Scandinavian Journal of Work, Environment & Health · doi:10.5271/sjweh.1851 · Cited by 228
Health Effects and Sources of Indoor Air Pollution. Part II
Samet, J. M., Marbury, M. C., & Spengler, J. D. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/137.1.221 · Cited by 176
Building-Associated Risk of Febrile Acute Respiratory Diseases in Army Trainees
Brundage, J. F. (1988) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1988.03720140028029 · Cited by 158
Work-related illness in offices: A proposed model of the “sick building syndrome”
Hedge, A., Burge, P. S., Robertson, A. S., Wilson, S., & Harris-Bass, J. (1989) · Environment International · doi:10.1016/0160-4120(89)90020-2 · Cited by 125
Cited by
Translating Social Ecological Theory into Guidelines for Community Health Promotion
Stokols, D. (1996) · American Journal of Health Promotion · doi:10.4278/0890-1171-10.4.282 · Cited by 2,763
Establishing and maintaining healthy environments: Toward a social ecology of health promotion.
Stokols, D. (1992) · American Psychologist · doi:10.1037//0003-066x.47.1.6 · Cited by 2,009
Jones, A. P. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00272-1 · Cited by 1,481
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Self-citationAl horr, Y., Arif, M., Katafygiotou, M., Mazroei, A., Kaushik, A., & Elsarrag, E. (2016) · International Journal of Sustainable Built Environment · doi:10.1016/j.ijsbe.2016.03.006 · Cited by 817
A Case Control Etiologic Study of Sarcoidosis: Environmental and Occupational Risk Factors
Newman, L. S., Rose, C. S., Bresnitz, E. A., Rossman, M. D., Barnard, J., Frederick, M., Terrin, M. L., Weinberger, S. E., Moller, D. R., McLennan, G., et al. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200402-249oc · Cited by 801
Wargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., et al. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01145.x · Cited by 418
Meadow, J. F., Altrichter, A. E., Kembel, S. W., Kline, J., Mhuireach, G., Moriyama, M., Northcutt, D., O'Connor, T. K., Womack, A. M., Brown, G. Z., et al. (2014) · Indoor Air · doi:10.1111/ina.12047 · Cited by 411
Influence of indoor environmental quality on human health and productivity - A review
Mujan, I., Anđelković, A. S., Munćan, V., Kljajić, M., & Ružić, D. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.01.307 · Cited by 405
Tham, K. W. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.071 · Cited by 399
Sick building syndrome: Figure 1
Burge, P. S. (2004) · Occupational and Environmental Medicine · doi:10.1136/oem.2003.008813 · Cited by 345
APTE, M. G., FISK, W. J., & DAISEY, J. M. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004246.x · Cited by 341
Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 284
Self-citationSeppänen, O., & Fisk, W. J. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01111.x · Cited by 277
An Epidemic of Pneumococcal Disease in an Overcrowded, Inadequately Ventilated Jail
Hoge, C. W., Reichler, M. R., Dominguez, E. A., Bremer, J. C., Mastro, T. D., Hendricks, K. A., Musher, D. M., Elliott, J. A., Facklam, R. R., & Breiman, R. F. (1994) · New England Journal of Medicine · doi:10.1056/nejm199409083311004 · Cited by 271
Santamouris, M., Synnefa, A., Asssimakopoulos, M., Livada, I., Pavlou, K., Papaglastra, M., Gaitani, N., Kolokotsa, D., & Assimakopoulos, V. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.04.002 · Cited by 253
Rashid, M., & Zimring, C. (2008) · Environment and Behavior · doi:10.1177/0013916507311550 · Cited by 252
Hydronic radiant cooling — preliminary assessment
Feustel, H. E., & Stetiu, C. (1995) · Energy and Buildings · doi:10.1016/0378-7788(95)00922-k · Cited by 237
Metadata
- Authors
- Mendell, M. J., & Smith, A. H.
- Venue
- American Journal of Public Health
- Publisher
- American Public Health Association
- Published
- 1990-10
- Volume
- 80
- Issue
- 10
- Pages
- 1193-1199
- ISSN
- 0090-0036 (ISSN-L)
- 1541-0048
- OpenAlex
- W2132054230
- Cited by
- 258
- References
- 16
- FWCI
- 26.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.