Metal Sensitivity in Patients with Orthopaedic Implants
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
All metals in contact with biological systems undergo corrosion. This electrochemical process leads to the formation of metal ions, which may activate the immune system by forming complexes with endogenous proteins. Implant degradation products have been shown to be associated with dermatitis, urticaria, and vasculitis. If cutaneous signs of an allergic response appear after implantation of a metal device, metal sensitivity should be considered. Currently, there is no generally accepted test for the clinical determination of metal hypersensitivity to implanted devices. The prevalence of dermal sensitivity in patients with a joint replacement device, particularly those with a failed implant, is substantially higher than that in the general population. Until the roles of delayed hypersensitivity and humoral immune responses to metallic orthopaedic implants are more clearly defined, the risk to patients may be considered minimal. It is currently unclear whether metal sensitivity is a contributing factor to implant failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE CHEMOTACTIC EFFECT OF MIXTURES OF ANTIBODY AND ANTIGEN ON POLYMORPHONUCLEAR LEUCOCYTES
Boyden, S. (1962) · The Journal of Experimental Medicine · doi:10.1084/jem.115.3.453 · Cited by 2,733
Nelson, R. D., Quie, P. G., & Simmons, R. L. (1975) · The Journal of Immunology · doi:10.4049/jimmunol.115.6.1650 · Cited by 1,170
Sensitivity to titanium. A cause of implant failure?
Lalor, P., Revell, P., Gray, A., Wright, S., Railton, G., & Freeman, M. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b1.1991768 · Cited by 393
Nickel, cobalt and chromium in consumer products: a role in allergic contact dermatitis?
Basketter, D. A., Briatico‐Vangosa, G., Kaestner, W., Lally, C., & Bontinck, W. J. (1993) · Contact Dermatitis · doi:10.1111/j.1600-0536.1993.tb03318.x · Cited by 257
Immune Response to Synthetic Materials: Sensitization of Patients Receiving Orthopaedic Implants
Merritt, K., & Rodrigo, J. J. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199605000-00009 · Cited by 222
Self-citationThe incidence of cancer following total hip replacement
Gillespie, W., Frampton, C., Henderson, R., & Ryan, P. (1988) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.70b4.3403594 · Cited by 222
Cell culture methods for testing Biocompatibility
Pizzoferrato, A., Ciapetti, G., Stea, S., Cenni, E., Arciola, C. R., Granchi, D., & Lucia (1994) · Clinical Materials · doi:10.1016/0267-6605(94)90081-7 · Cited by 207
Black, J., Sherk, H., Bonini, J., Rostoker, W. R., Schajowicz, F., & Galante, J. O. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072010-00021 · Cited by 187
Moulon, C., Vollmer, J., & Weltzien, H. (1995) · European Journal of Immunology · doi:10.1002/eji.1830251216 · Cited by 168
Systemic effects of biomaterials
Blac, J. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90061-9 · Cited by 166
Cited by
Nanomaterials and nanoparticles: Sources and toxicity
Buzea, C., Pacheco, I. I., & Robbie, K. (2007) · Biointerphases · doi:10.1116/1.2815690 · Cited by 3,789
Wang, X., Xu, S., Zhou, S., Xu, W., Leary, M., Choong, P., Qian, M., Brandt, M., & Xie, Y. M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.012 · Cited by 2,121
WILLERT, H.-G., BUCHHORN, G. H., FAYYAZI, A., FLURY, R., WINDLER, M., KÖSTER, G., & LOHMANN, C. H. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200501000-00006 · Cited by 1,192
Macrophages, Foreign Body Giant Cells and Their Response to Implantable Biomaterials
Sheikh, Z., Brooks, P., Barzilay, O., Fine, N., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095269 · Cited by 701
Osteoinduction of bone grafting materials for bone repair and regeneration
García-Gareta, E., Coathup, M. J., & Blunn, G. W. (2015) · Bone · doi:10.1016/j.bone.2015.07.007 · Cited by 649
Titanium dioxide in our everyday life; is it safe?
Skocaj, M., Filipic, M., Petkovic, J., & Novak, S. (2011) · Radiology and Oncology · doi:10.2478/v10019-011-0037-0 · Cited by 549
Wang, S.-P., & Xu, J. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.12.057 · Cited by 402
Metal Allergy—A Review on Exposures, Penetration, Genetics, Prevalence, and Clinical Implications
Thyssen, J. P., & Menné, T. (2010) · Chemical Research in Toxicology · doi:10.1021/tx9002726 · Cited by 398
Xu, W., Huang, L., Wong, M., Chen, L., Bai, G., & Hao, J. (2017) · Advanced Energy Materials · doi:10.1002/aenm.201601529 · Cited by 342
Wear particles, periprosthetic osteolysis and the immune system
Goodman, S. B. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.035 · Cited by 340
“Hallab et al recognized that hypersensitivity and an excessive eczematous immune reaction to implanted metallic biomaterials probably exists in less than 1% of those undergoing total joint replacement [21].”
BackgroundEARLY OSTEOLYSIS FOLLOWING SECOND-GENERATION METAL-ON-METAL HIP REPLACEMENT
PARK, Y.-S., MOON, Y.-W., LIM, S.-J., YANG, J.-M., AHN, G., & CHOI, Y.-L. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200507000-00014 · Cited by 322
Keegan, G. M., Learmonth, I. D., & Case, C. P. (2007) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.89b5.18903 · Cited by 321
The Biology of Aseptic Osteolysis
Holt, G., Murnaghan, C., Reilly, J., & Meek, R. M. D. (2007) · Clinical Orthopaedics & Related Research · doi:10.1097/blo.0b013e31804b4147 · Cited by 319
Hardware Removal: Indications and Expectations
Busam, M. L., Esther, R. J., & Obremskey, W. T. (2006) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-200602000-00006 · Cited by 313
Drouet, C. (2013) · BioMed Research International · doi:10.1155/2013/490946 · Cited by 304
The effects on bone cells of metal ions released from orthopaedic implants. A review
Sansone, V (2013) · CLINICAL CASES IN MINERAL AND BONE METABOLISM · doi:10.11138/ccmbm/2013.10.1.034 · Cited by 289
Lymphocyte responses in patients with total hip arthroplasty
Hallab, N. J., Anderson, S., Stafford, T., Glant, T., & Jacobs, J. J. (2005) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2004.09.001 · Cited by 253
Self-citationTitanium: a review on exposure, release, penetration, allergy, epidemiology, and clinical reactivity
Fage, S. W., Muris, J., Jakobsen, S. S., & Thyssen, J. P. (2016) · Contact Dermatitis · doi:10.1111/cod.12565 · Cited by 222
Biomedical applications of polyethylene
Paxton, N. C., Allenby, M. C., Lewis, P. M., & Woodruff, M. A. (2019) · European Polymer Journal · doi:10.1016/j.eurpolymj.2019.05.037 · Cited by 215
Cutaneous and Systemic Hypersensitivity Reactions to Metallic Implants
Basko-Plluska, J. L., Thyssen, J. P., & Schalock, P. C. (2011) · Dermatitis · doi:10.2310/6620.2011.10055 · Cited by 209
“Accumulated reports of metal allergy in total hip arthroplasty patients showed that the prevalence of metal allergy was approximately 25% among patients with a well-functioning hip arthroplastic implant and 60% among patients with a failed or poorly functioning implant.(9) Despite these prevalences’ being much higher…”
BackgroundInfluentialSpinal Implant Debris-Induced Osteolysis
Hallab, N. J., Cunningham, B. W., & Jacobs, J. J. (2003) · Spine · doi:10.1097/00007632-200310151-00006 · Cited by 201
“concerned about metal hypersensitivity.(98) –100 These methods promise the surgeon a tool for optimizing materials selection in spinal instrumentation.”
BackgroundSelf-citationMILOŠEV, I., TREBŠE, R., KOVAČ, S., CÖR, A., & PIŠOT, V. (2006) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200606000-00002 · Cited by 197
Mediators of the inflammatory response to joint replacement devices
Cobelli, N., Scharf, B., Crisi, G. M., Hardin, J., & Santambrogio, L. (2011) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2011.128 · Cited by 196
Metal release from stainless steel, Co–Cr–Mo–Ni–Fe and Ni–Ti alloys in vascular implants
Okazaki, Y., & Gotoh, E. (2008) · Corrosion Science · doi:10.1016/j.corsci.2008.09.002 · Cited by 181
HUBER, M., REINISCH, G., TRETTENHAHN, G., ZWEYMULLER, K., & LINTNER, F. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.07.032 · Cited by 180
Cadosch, D., Chan, E., Gautschi, O. P., & Filgueira, L. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32625 · Cited by 180
Metal hypersensitivity testing in patients undergoing joint replacement: A systematic review
Granchi, D., Cenni, E., Giunti, A., & Baldini, N. (2012) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.94b8.28135 · Cited by 164
Fleury, C., Petit, A., Mwale, F., Antoniou, J., Zukor, D. J., Tabrizian, M., & Huk, O. L. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.035 · Cited by 163
Metadata
- Authors
- Hallab, N., Merritt, K., & Jacobs, J. J.
- Venue
- The Journal of Bone and Joint Surgery-American Volume
- Published
- 2001-03
- Volume
- 83
- Issue
- 3
- Pages
- 428-436
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2103907018
- Cited by
- 935
- References
- 30
- FWCI
- 15.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.