Release of Gentamicin from Acrylic Bone Cement
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The pharmacokinetics of gentamicin were studied after total hip joint arthroplasties performed with "Palacos R plus gentamicin' in 10 patients. Urine was collected at 12-hour intervals for 15 days after operation, and drainage fluids for 48, 72 or 108 hours. Blood samples were taken 3 and/or 5 hours after prosthesis implantation. High concentrations of gentamicin were found in drainage fluids. Excretion curves in drainage fluids or urine were fitted by a computer-aided design program (SIAM) and the mean curves established. Elimination of gentamicin was biphasic in both cases. The rapid phases had a half-life of 2.97 hours in drainage fluids and 7.16 hours in urine. Half-lives of the slow phases were 13.5 and 47.12 hours, respectively. The mean percentage of total gentamicin released by the two routes was 5.78% of the quantity implanted. The calculated peak blood concentration was 0.12 mg/L. It is concluded that gentamicin concentrations locally reach levels higher than minimum inhibitory concentrations of most of the likely pathogens in patients undergoing total hip joint arthroplasties with "Palacos R plus gentamicin' bone cement. However, as blood concentrations appear to be low, patients may not be protected against systemic infections.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Nevertheless, their use is also associated with drawbacks such as unpredictable long-term efficacy, potential antibiotic resistance and local tissue toxicity.”
From Quaternary ammonium-based biomedical materials: State-of-the-art, toxicological aspects and antimicrobial resistance (2017) · cites this paper as [203]
In the citing paper
“These issues may compromise cell and bone regeneration and implant osseointegration [202], [203].”
From Quaternary ammonium-based biomedical materials: State-of-the-art, toxicological aspects and antimicrobial resistance (2017) · cites this paper as [203]
Citations
Cites
[Depot effects of various antibiotics mixed with Palacos resins].
Hw, B., & Engelbrecht, H. (1970) · PubMed · Cited by 768
CHARNLEY, J. (1972) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197209000-00020 · Cited by 432
Hill, C., Mazas, F., Flamant, R., & Evrard, J. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92678-7 · Cited by 371
Whelton, A. (1984) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198411000-00010 · Cited by 320
Salvati, E. A., Robinson, R. P., Zeno, S. M., Koslin, B. L., Brause, B. D., & Wilson, P. D. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264040-00007 · Cited by 290
Jackson, G. G., & Arcieri, G. (1971) · Journal of Infectious Diseases · doi:10.1093/infdis/124.supplement_1.s130 · Cited by 244
Antibiotic-loaded acrylic cement
Elson, R., Jephcott, A., McGechie, D., & Verettas, D. (1977) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.59b2.873980 · Cited by 179
JOSEFSSON, G., LINDBERG, L., & WIKLANDER, B. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198109000-00027 · Cited by 161
Wahlig, H., Dingeldein, E., Buchholz, H., Buchholz, M., & Bachmann, F. (1984) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.66b2.6707051 · Cited by 145
Deep infection after total hip replacement
Andrews, H., Arden, G. P., Hart, G., & Owen, J. (1981) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.63b1.7009620 · Cited by 130
Cited by
Jiao, Y., Niu, L.-N., Ma, S., Li, J., Tay, F. R., & Chen, J.-H. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.03.001 · Cited by 639
“The effectiveness of such devices is strongly dependent on the release rate of the loaded drugs [204] .”
BackgroundAntibiotic-eluting medical devices for various applications
ZILBERMAN, M., & ELSNER, J. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.05.020 · Cited by 610
Masters, E. A., Trombetta, R. P., de Mesy Bentley, K. L., Boyce, B. F., Gill, A. L., Gill, S. R., Nishitani, K., Ishikawa, M., Morita, Y., Ito, H., et al. (2019) · Bone Research · doi:10.1038/s41413-019-0061-z · Cited by 575
Drug/device combinations for local drug therapies and infection prophylaxis
Wu, P., & Grainger, D. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.031 · Cited by 491
“[158] Bunetel L, Segui A, Cormier M, Percheron E, Langlais F.”
BackgroundHANSSEN, A. D., & RAND, J. A. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199806000-00016 · Cited by 445
Bioactive Coatings for Orthopaedic Implants—Recent Trends in Development of Implant Coatings
Zhang, B., Myers, D., Wallace, G., Brandt, M., & Choong, P. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms150711878 · Cited by 394
“Only 20% of gentamicin is released from PMMA cement for the duration of hip implant function [285]; Secondly, antibiotics can affect the mechanical properties of the PMMA cement accelerating implant loosening.”
Collagen as a carrier for on-site delivery of antibacterial drugs
Ruszczak, Z. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.007 · Cited by 367
“[43] demonstrated a biphasic release with primary halflives of 2.”
BackgroundLong-term elution of antibiotics from bone-cement
Masri, B. A., Duncan, C. P., & Beauchamp, C. P. (1998) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(98)90179-6 · Cited by 356
Infection of orthopedic implants and the use of antibiotic-loaded bone cements: A review
Belt, H. V. D., Neut, D., Schenk, W., Horn, J. R. V., Mei, H. C. V. D., & Busscher, H. J. (2001) · Acta Orthopaedica Scandinavica · doi:10.1080/000164701317268978 · Cited by 343
Elution characteristics of vancomycin and tobramycin combined in acrylic bone—cement
Penner, M. J., Masri, B. A., & Duncan, C. P. (1996) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(96)80135-5 · Cited by 324
Backgrounds of antibiotic-loaded bone cement and prosthesis-related infection
Hendriks, J. G. E., van Horn, J. R., van der Mei, H. C., & Busscher, H. J. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00554-4 · Cited by 291
“The nature of the release was again bi-phasic with a peak release in the first hours, followed by a steadily decreasing but ongoing release that can be measured for months [87,130,133].”
Backgroundvan de Belt, H., Neut, D., Uges, D. R. A., Schenk, W., van Horn, J. R., van der Mei, H. C., & Busscher, H. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00082-x · Cited by 277
Springer, B. D., Lee, G.-C., Osmon, D., Haidukewych, G. J., Hanssen, A. D., & Jacofsky, D. J. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000144476.43661.10 · Cited by 273
“higher than can be achieved with parenteral administration alone.(1,3,5,9,14,15,25,27,28,30)”
BackgroundLocal Antibiotic Therapy in Osteomyelitis
Gogia, J., Meehan, J., Di Cesare, P., & Jamali, A. (2009) · Seminars in Plastic Surgery · doi:10.1055/s-0029-1214162 · Cited by 207
Antibiotic-impregnated cement and beads for orthopedic infections
Wininger, D. A., & Fass, R. J. (1996) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.40.12.2675 · Cited by 211
Bertazzoni Minelli, E. (2004) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkh032 · Cited by 198
Thornes, B., Murray, P., & Bouchier-Hayes, D. (2002) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.84b5.11907 · Cited by 189
Biodegradable vs non-biodegradable antibiotic delivery devices in the treatment of osteomyelitis
Kluin, O. S., van der Mei, H. C., Busscher, H. J., & Neut, D. (2013) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2013.751371 · Cited by 171
Belt, H. V. D., Neut, D., Schenk, W., Horn, J. R. V., Mei, H. C. V. D., & Busscher, H. J. (2000) · Acta Orthopaedica Scandinavica · doi:10.1080/000164700317362280 · Cited by 168
Enhancement of antibiotic elution from acrylic bone cement
Anagnostakos, K., & Kelm, J. (2009) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31281 · Cited by 146
The in vitro elution characteristics of antibiotic-loaded CMW and Palacos-R bone cements
Penner, M. J., Duncan, C. P., & Masri, B. A. (1999) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(99)90128-6 · Cited by 140
Acute renal failure after local gentamicin treatment in an infected total knee arthroplasty
van Raaij, T. M., Visser, L. E., Vulto, A. G., & Verhaar, J. A. N. (2002) · The Journal of Arthroplasty · doi:10.1054/arth.2002.34525 · Cited by 130
The effects of amorphous carbon films deposited on polyethylene terephthalate on bacterial adhesion
Wang, J., Huang, N., Yang, P., Leng, Y. X., Sun, H. L., Liu, Z. Y., & Chu, P. K.-H. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.010 · Cited by 124
Patrick, B. N., Rivey, M. P., & Allington, D. R. (2006) · Annals of Pharmacotherapy · doi:10.1345/aph.1h173 · Cited by 120
Fink, B., Vogt, S., Reinsch, M., & Büchner, H. (2011) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-011-1937-4 · Cited by 120
The effect of mixing on gentamicin release from polymethylmethacrylate bone cements
Neut, D., van de Belt, H., van Horn, J., van der Mei, H. C., & Busscher, H. J. (2003) · Acta Orthopaedica Scandinavica · doi:10.1080/00016470310018180 · Cited by 115
“In vitro and in vivo studies have shown that only small amounts of the antibiotics incorporated in bone cement are actually released (Schurman et al. 1978, Hoff et al. 1981, Törholm et al. 1983, Bunetel et al. 1989, Chohfi et al. 1998), because the release is largely a surface phenomenon.”
BackgroundAviv, M., Berdicevsky, I., & Zilberman, M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31184 · Cited by 114
“This heat as well as residual MMA monomers can kill healthy surrounding bone cells.(7) Additional disadvantages are the low bonding strength of PMMA to the implant surface and known soft tissue encapsulation of PMMA.”
BackgroundLewis, G. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31220 · Cited by 127
Polylactide-polyglycolide Antibiotic Implants
Garvin, K. L., & Feschuk, C. A. (2005) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000175720.99118.fe · Cited by 110
“for 15 days and only 20% was released for the duration of the implant function.(11) Polymethylmethacrylate also re-”
BackgroundCurtis, J. M., Sternhagen, V., & Batts, D. H. (2005) · Pharmacotherapy The Journal of Human Pharmacology and Drug Therapy · doi:10.1592/phco.2005.25.6.876 · Cited by 94
“Antibiotics are released from bone cement in a biphasic manner.(4) A peak release within the first 24 hours is followed by a low, continuous release that continues for months to years.”
BackgroundMiyai, T., Ito, A., Tamazawa, G., Matsuno, T., Sogo, Y., Nakamura, C., Yamazaki, A., & Satoh, T. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.09.040 · Cited by 99
Takahira, N., Itoman, M., Higashi, K., Uchiyama, K., Miyabe, M., & Naruse, K. (2003) · Journal of Orthopaedic Science · doi:10.1007/s007760300004 · Cited by 89
Dovas, S., Liakopoulos, V., Papatheodorou, L. K., Chronopoulou, I., Papavasiliou, V. A., Atmatzidis, E., Giannopoulou, M., Eleftheriadis, T., Simopoulou, T., Karachalios, T. S., et al. (2008) · Clinical Nephrology · doi:10.5414/cnp69207 · Cited by 91
“Indeed, high concentrations of antibiotics have been found in drainage fluids while serum levels remain below that usually required to cause nephrotoxicity [Bunetel et al. 1989, Hofmann et al. 1995, Salvati et al. 1986, Sterling et al. 2003, Soto-Hall et al. 1983, Walenkamp et al. 1988]. Springer et al. [2004] noticed…”
BackgroundBiodegradable Polymers for Orthopedic Applications
Zhang, X., Mattheus, Goosen, F. A., Wyss, S. P., & Pichora, D. (1993) · Journal of Macromolecular Science, Part C: Polymer Reviews · doi:10.1080/15321799308021434 · Cited by 88
In vitro antibiotic release from poly(3-hydroxybutyrate-co-3-hydroxyvalerate) rods
Gürsel, İ., Yagmurlu, F., Korkusuz, F., & Hasırcı, V. (2002) · Journal of Microencapsulation · doi:10.1080/02652040110065413 · Cited by 98
“One known approach to realizing the above mentioned therapy involves the implantation of antibiotic (especially gentamicin1) loaded polymethylmethacrylate beads (Wahling et al. 1978, Baker and Greenham 1988, Bucholz et al. 1989).”
BackgroundCerretani, D., Giorgi, G., Fornara, P., Bocchi, L., Neri, L., Ceffa, R., Ghisellini, F., & Ritter, M. A. (2002) · The Journal of Arthroplasty · doi:10.1054/arth.2002.32184 · Cited by 83
Yamamoto, K., Miyagawa, N., Masaoka, T., Katori, Y., Shishido, T., & Imakiire, A. (2003) · Journal of Orthopaedic Science · doi:10.1007/s00776-003-0722-y · Cited by 80
Ensing, G. T., Roeder, B. L., Nelson, J. L., Horn, J. R., der Mei, H. C., Busscher, H. J., & Pitt, W. G. (2005) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2005.02643.x · Cited by 79
Pichavant, L., Amador, G., Jacqueline, C., Brouillaud, B., Héroguez, V., & Durrieu, M. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.06.033 · Cited by 87
“In vivo studies also confirm that only a minor portion (5–18%) of gentamicin incorporated in bone cements is eluted [42].”
BackgroundFrutos, P., Díez-Peña, E., Frutos, G., & Barrales‐Rienda, J. M. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00028-5 · Cited by 74
Mechanical and Bioactive Properties of PMMA Bone Cement: A Review
Seesala, V. S., Sheikh, L., Basu, B., & Mukherjee, S. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c00779 · Cited by 79
Neut, D., de Groot, E. P., Kowalski, R. S. Z., van Horn, J. R., van der Mei, H. C., & Busscher, H. J. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30253 · Cited by 69
Gentamicin bone cements: characterisation and release (in vitro and in vivo assays)
Torrado, S., Frutos, P., & Frutos, G. (2001) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(01)00587-7 · Cited by 72
Preparation and characterization of biodegradable poly(l-lactic acid) gentamicin delivery systems
Sampath, S. S., Garvin, K. L., & Robinson, D. H. (1992) · International Journal of Pharmaceutics · doi:10.1016/0378-5173(92)90367-b · Cited by 62
Contemporary Concepts in the Treatment of Chronic Osteomyelitis
Coviello, V. F., & Stevens, M. R. (2007) · Oral and Maxillofacial Surgery Clinics of North America · doi:10.1016/j.coms.2007.07.001 · Cited by 56
Duey, R. E., Chong, A. C. M., McQueen, D. A., Womack, J. L., Song, Z., Steinberger, T. A., & Wooley, P. H. (2012) · Europe PMC (PubMed Central) · Cited by 54
Schmolders, J., Hischebeth, G. T. R., Friedrich, M. J., Randau, T. M., Wimmer, M. D., Kohlhof, H., Molitor, E., & Gravius, S. (2014) · BMC Infectious Diseases · doi:10.1186/1471-2334-14-144 · Cited by 52
“More studies have proven high concentrations of antibiotics in the drainage fluid during the first few days after the implantation of an antibiotic-impregnated spacer [14,24,25].”
BackgroundAntibiotic-Coated Interlocking Intramedullary Nail for the Treatment of Long-Bone Osteomyelitis
Barger, J., Fragomen, A. T., & Rozbruch, S. R. (2017) · JBJS Reviews · doi:10.2106/jbjs.rvw.16.00095 · Cited by 52
In vitro release of gentamicin from OHAp/PEMA/PMMA samples
Padilla, S., del Real, R. P., & Vallet‐Regí, M. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00168-2 · Cited by 49
External Skeletal Fixation in Ruminants
Anderson, D. E., & Jean, G. S. (1996) · Veterinary Clinics of North America Food Animal Practice · doi:10.1016/s0749-0720(15)30439-4 · Cited by 48
Microencapsulation of gentamicin in biodegradable PLA and/or PLA/PEG copolymer
Y.-Y. Huang, T.-W. C. (2001) · Journal of Microencapsulation · doi:10.1080/02652040010019479 · Cited by 63
“Pharmacokinetic studies of gentamicin-impregnated acrylic cement in 10 patients undergoing total hip joint arthroplasties indicated that only 5.78% of the total quantity implanted was released over 15 days (Bunetel et al. 1989).”
BackgroundInfluentialRelease of netilmicin and vancomycin from cancellous bone
Witsø, E., Persen, L. N., Benum, P., & Bergh, K. (2002) · Acta Orthopaedica Scandinavica · doi:10.1080/000164702753671812 · Cited by 47
“…bone cement and biodegradable materials, PBS, serum, sterile water and Mueller Hinton broth have been used as the elution uid (Picknell et al.1977, Baker and Greenham 1988, Becker et al. 1994, Adams et al.1992, Miclau et al. 1993, Mader et al. 1997, Klekamp et al. 1999, Witsø et al. 1999, 2000).”
MethodThe effect of antibiotics on bone healing: current evidence
Pountos, I., Georgouli, T., Bird, H. A., Kontakis, G. M., & Giannoudis, P. V. (2011) · Expert Opinion on Drug Safety · doi:10.1517/14740338.2011.589833 · Cited by 47
Salmonella septic arthritis in systemic lupus erythematosus and other systemic diseases
Chen, J. Y., Luo, S.-F., Wu, Y. J. J., Wang, C. M., & Ho, H.-H. (1998) · Clinical Rheumatology · doi:10.1007/bf01451006 · Cited by 41
Management of Fractures in Field Settings
Anderson, D. E., & Jean, G. S. (2008) · Veterinary Clinics of North America Food Animal Practice · doi:10.1016/j.cvfa.2008.07.006 · Cited by 40
Antibiotic-loaded cement spacers – lessons learned from the past 20 years
Anagnostakos, K., & Fink, B. (2018) · Expert Review of Medical Devices · doi:10.1080/17434440.2018.1435270 · Cited by 40
“stances, air can be included in the cement matrix which leads to voids and cracks [22].”
BackgroundComparing the efficacy of three bioceramic matrices for the release of vancomycin hydrochloride
Jiang, P., Patel, S., Gbureck, U., Caley, R., & Grover, L. M. (2009) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31557 · Cited by 44
Pithankuakul, K., Samranvedhya, W., Visutipol, B., & Rojviroj, S. (2014) · The Journal of Arthroplasty · doi:10.1016/j.arth.2014.12.003 · Cited by 37
Zhang, X., Chaimayo, W., Yang, C., Yao, J., Miller, B. L., & Yates, M. Z. (2017) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2017.06.013 · Cited by 40
Local antibiotic delivery with demineralized bone matrix
Lewis, C. S., Supronowicz, P., Zhukauskas, R. M., Gill, E., & Cobb, R. R. (2010) · Cell and Tissue Banking · doi:10.1007/s10561-010-9236-y · Cited by 36
“In addition to high variability in elution rates (Buttaro et al. 2004; McLaren 2004; Stevens et al. 2005), a number of studies have revealed sub-therapeutic and intermittent drug release amongst various bone cements ( Bunetel et al. 1989; DiMaio et al. 1994; Levin 1975; Miclau et al. 1993).”
BackgroundFactors Influencing Bacterial Adhesion
Merritt, K., & An, Y. H. (2000) · Humana Press eBooks · doi:10.1007/978-1-59259-224-1_4 · Cited by 44
Langowska, K., Kowal, J., Palivan, C. G., & Meier, W. P. (2014) · Journal of Materials Chemistry B · doi:10.1039/c4tb00277f · Cited by 46
Ozaki, T., Yoshitaka, T., Kunisada, T., Dan’ura, T., Naito, N., & Inoue, H. (1998) · Journal of Orthopaedic Science · doi:10.1007/s007760050037 · Cited by 31
Periprosthetic Joint Infection of the Hip and Knee
Springer, B. D., & Parvizi, J. (2013) · Springer eBooks · doi:10.1007/978-1-4614-7928-4 · Cited by 35
Local Antibiotic Therapy in the Treatment of Bone and Soft Tissue Infections
Tsourvakas, S. (2012) · InTech eBooks · doi:10.5772/28833 · Cited by 38
Witsø, E., Persen, L. N., Benum, P., Aamodt, A., Husby, O. S., & Bergh, K. (2004) · Acta Orthopaedica Scandinavica · doi:10.1080/00016470410001295 · Cited by 30
“…fluid from the hip joint have ranged from 25 to 118 mg/L of gentamicin (Wahlig and Dingeldein 1980, Wahlig et al. 1984, Salvati et al. 1986, Bunetel et al. 1989, 1990, Lindberg et al. 1991) and 9–43 mg/ L of tobramycin (Soto-Hall et al. 1983, Brien et al. 1993, Masri et al. 1998, Della…”
BackgroundRETRACTED: Cement Spacer Loaded With Antibiotics for Infected Implants of the Hip Joint
Yamamoto, K., Miyagawa, N., Masaoka, T., Katori, Y., Shishido, T., & Imakiire, A. (2007) · The Journal of Arthroplasty · doi:10.1016/j.arth.2004.06.032 · Cited by 28
RetractedWaśko, M. K., & Kamiński, R. (2015) · BioMed Research International · doi:10.1155/2015/387186 · Cited by 27
Antibiotic cements in articular prostheses: current orthopaedic concepts
Langlais, F. L., Belot, N., ROPARS, M., Thomazeau, H., Lambotte, J., & Cathelineau, G. (2006) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2006.05.020 · Cited by 24
Self-citationMartínez‐Moreno, J., Mura, C., Merino, V., Nácher, A., Climente, M., & Merino‐Sanjuán, M. (2015) · The Journal of Arthroplasty · doi:10.1016/j.arth.2015.02.016 · Cited by 23
Cisplatin-loaded poly (methyl methacrylate) implants: a sustained drug delivery system
Mestiri, M., Benoît, J., Hernigou, P., Devissaguet, J. P., & Puisieux, F. (1995) · Journal of Controlled Release · doi:10.1016/0168-3659(94)00077-8 · Cited by 23
Comparative Study of Gentamicin Release from Normal and Low Viscosity Acrylic Bone Cement
Bunetel, L., Segui, A., Cormier, M., & Langlais, F. L. (1990) · Clinical Pharmacokinetics · doi:10.2165/00003088-199019040-00005 · Cited by 23
“The present study is the second pan of a work introduced by a previous anicle in the Journal (Bunetel et al. 1989).”
BackgroundSelf-citationCalcium hydroxide-modified zinc polycarboxylate dental cements
Zamanian, A., Yasaei, M., Ghaffari, M. S., & Mozafari, M. (2013) · Ceramics International · doi:10.1016/j.ceramint.2013.05.071 · Cited by 20
Mounasamy, V., Fulco, P. P., Desai, P., Adelaar, R. S., & Bearman, G. M. (2012) · European Journal of Orthopaedic Surgery & Traumatology · doi:10.1007/s00590-012-1062-4 · Cited by 19
Hess, U., Mikolajczyk, G., Treccani, L., Streckbein, P., Heiß, C., Odenbach, S., & Rezwan, K. (2016) · Materials Science and Engineering C · doi:10.1016/j.msec.2016.05.042 · Cited by 19
Antibacterial Analysis of a Zinc-based Glass Polyalkenoate Cement
Clarkin, O. M., Wren, A. W., Thornton, R. F., Cooney, J. C., & Towler, M. R. (2010) · Journal of Biomaterials Applications · doi:10.1177/0885328210364430 · Cited by 19
Helbig, L., Bechberger, M., Aldeeri, R. A., Ivanova, A., Haubruck, P., Miska, M., Schmidmaier, G., & Omlor, G. W. (2018) · Therapeutics and Clinical Risk Management · doi:10.2147/tcrm.s152008 · Cited by 17
Kelsey, R., Kor, A., & Cordano, F. (1995) · The Journal of Foot & Ankle Surgery · doi:10.1016/s1067-2516(09)80076-8 · Cited by 14
Dersch, G., & Winkler, H. (2022) · Antibiotics · doi:10.3390/antibiotics11030310 · Cited by 12
Seddighi, M. R., Griffon, D. J., Constable, P. D., & Martín‐Jiménez, T. (2007) · American Journal of Veterinary Research · doi:10.2460/ajvr.68.2.171 · Cited by 12
A case of an acute kidney injury secondary to an implanted aminoglycoside
Wu, I. M., Marin, E. P., Kashgarian, M. J., & Brewster, U. C. (2008) · Kidney International · doi:10.1038/ki.2008.386 · Cited by 12
“12 mg/l.(25) Our patient had higher levels of tobramycin than reported in the above series.”
ResultPMMA as Drug Delivery System and in vivo Release from Spacers
Minelli, E. B., & Benini, A. (2007) · Springer eBooks · doi:10.1007/978-3-540-47999-4_11 · Cited by 11
Addressing Medical Device Challenges with Drug–Device Combinations
Avula, M., & Grainger, D. W. (2015) · Wiley eBooks · doi:10.1002/9781119002956.ch01 · Cited by 12
İnceoğlu, S., Botimer, G. D., & Maskiewicz, V. K. (2020) · Journal of Orthopaedic Research® · doi:10.1002/jor.24919 · Cited by 11
Dual‐analgesic loaded UHMWPE exhibits synergistic antibacterial effects againstStaphylococci
Gil, D., Hugard, S., Borodinov, N., Ovchinnikova, O. S., Muratoglu, O. K., Bedair, H. S., & Oral, E. (2022) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.35201 · Cited by 11
Wilairatana, V., Sinlapavilawan, P., Honsawek, S., & Limpaphayom, N. (2016) · Journal of Orthopaedics and Traumatology · doi:10.1007/s10195-016-0432-9 · Cited by 10
“However, as reports of gentamicin toxicity used high doses of gentamicin for treatment of established periprosthetic joint infection, low-dose gentamicin premixed into bone cement should not cause harmful effects [10, 13].”
BackgroundTüzüner, T., Uygur, İ., Şencan, İ., Haklar, U., Oktaş, B., & Özdemir, D. (2007) · Journal of Orthopaedic Science · doi:10.1007/s00776-006-1107-9 · Cited by 11
Mazza, D., Calderaro, C., Iorio, R., Drogo, P., Andreozzi, V., & Ferretti, A. (2020) · Orthopedic Reviews · doi:10.4081/or.2020.8540 · Cited by 9
Samokhin, A. G., Kozlova, J. N., Korneev, D., Taranov, O. S., Fedorov, E. A., Pavlov, V. V., Витальевна, М. В., & Викторовна, Т. Н. (2018) · Annals of the Russian academy of medical sciences · doi:10.15690/vramn905 · Cited by 9
Merkhan, I. K., Hasenwinkel, J. M., & Gilbert, J. L. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30033 · Cited by 9
Kamath, A. F., Anakwenze, O. A., Lee, G., & Nelson, C. L. (2011) · Advances in Orthopedics · doi:10.4061/2011/398954 · Cited by 7
“found no long-term elution rate difference between beads and spacers with the use of gentamicin [38].”
BackgroundEffect of gentamicin loaded PMMA bone cement onStaphylococcus aureusbiofilm formation
Poelstra, K., Busscher, H., Schenk, W., Horn, J. V., & van der Mei, H. C. (1999) · Biofouling · doi:10.1080/08927019909378416 · Cited by 7
Mathey, M., Surana, V., Edwards, M., & Nicholson, J. W. (2009) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-009-3717-1 · Cited by 8
Chalmers, P. N., Frank, J. M., & Sporer, S. M. (2012) · JBJS Case Connector · doi:10.2106/jbjs.cc.k.00094 · Cited by 5
Antibiotic-loaded bone cements
Farrar, D. F., BENSON, R., & MILNER, R. (2010) · Elsevier eBooks · doi:10.1533/9781845697488.2.190 · Cited by 5
Contrasting Effects of Physical Wear on Elution of Two Antibiotics from Orthopedic Cement
Dodds, S., Smith, T. J., Akid, R., Stephenson, J. R., Nichol, T., Banerjee, R. D., Stockley, I., & Townsend, R. W. (2011) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.01588-10 · Cited by 5
“C18 (2) column (150 by 1 mm; particle size, 5 m; Phenomenex, Inc.”
InfluentialShaw, J., Gary, J. L., Baker, A., Kaplan, H. B., Kim, Y., Milhoan, M., Burgess, A. R., & Ambrose, C. G. (2020) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0000000000001729 · Cited by 4
Antibiotic Loaded Acrylic Bone Cement in Orthopaedic Trauma
Samuel, S. (2012) · InTech eBooks · doi:10.5772/30194 · Cited by 4
Touzopoulos, P., Arvanitidis, K. I., Filidou, E., Tilkeridis, K. E., Karanikas, M., Kolios, G. C., & Ververidis, A. N. (2020) · Orthopaedics & Traumatology Surgery & Research · doi:10.1016/j.otsr.2020.102794 · Cited by 4
Ciments orthopédiques aux antibiotiques : du laboratoire à la validation clinique
Langlais, F. L. (2004) · Bulletin de l Académie Nationale de Médecine · doi:10.1016/s0001-4079(19)33692-1 · Cited by 3
Self-citation
Metadata
- Authors
- Bunetel, L., Segui, A., Cormier, M., Percheron, E., & Langlais, F.
- Venue
- Clinical Pharmacokinetics
- Published
- 1989-10
- Volume
- 17
- Issue
- 4
- Pages
- 291-297
- ISSN
- 0312-5963 (ISSN-L)
- OpenAlex
- W2000057239
- Semantic Scholar
- 46a94a04a6a76f3ce6e308c1f74b3fcaf02b1903
- Cited by
- 123
- References
- 17
- Citations by year
- 2026: 1 · 2024: 1 · 2022: 2 · 2021: 1 · 2020: 4 · 2019: 1 · 2018: 4 · 2017: 3 · 2016: 2 · 2015: 5 · 2014: 4 · 2013: 7 · 2012: 6
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Pharmacokinetics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Orthopedic Infections and Treatments
- Health Sciences › Medicine › Pharmacology (medical) › Antibiotics Pharmacokinetics and Efficacy
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- gentamicin, acrylic bone cement, total hip arthroplasty, antibiotic release, pharmacokinetics, urinary excretion, elimination half-life, Palacos R
- MeSH terms
- Adult, Aged, Bacterial Infections, Bone Cements, Drug Combinations, Evaluation Studies as Topic, Female, Gentamicins, Hip Prosthesis, Humans, Male, Methylmethacrylates, Middle Aged, Postoperative Complications, Methylmethacrylate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.