Selective Recording of Electroneurograms from the Sciatic Nerve of a Dog with Multi-Electrode Spiral Cuffs.
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Electroneurograms (ENGs) from superficial regions of the sciatic nerve of a Beagle dog were recorded selectively with a chronically implanted 33-electrode spiral cuff (cuff). By delivering stimulating pulses to groups of three electrodes (GTEs) within the cuff we could define the relative positions of the particular superficial regions that selectively innervated the tibialis anterior (TA) and gastrocnemius muscles (GM). GTEs with and without contractions of the TA and GM muscles were selected and connected to a 4-channel ENG system designed to amplify ENGs by 100,000 times and to pass frequencies between 500 Hz and 10 kHz. In our study, 12 experiments were conducted on three Beagle dogs with a cuff implanted for up to 2 years. We present the results obtained in four experiments conducted on one animal. With the implanted leg mounted in a special electronic brace we applied extending forces to the ankle, rotating it by up to 37 degrees according to the neutral position, eliciting torque to stretch the TA muscle. Only the ENG from a GTE eliciting maximum contraction of the TA muscle showed activities corresponding to the trajectory of the mechanical load of the muscle. Next, we dissected the calcanean tendon (CT) of the implanted leg and applied repetitive pull forces to the CT. Only the ENG from the GTE eliciting maximum contraction of the GM muscle was activated in correspondence to the trajectory of the mechanical load applied on the CT. The results suggest that the cuff, implanted chronically on the sciatic nerve, is useful to record ENGs of the afferent fibers from TA and GM muscles selectively and that the technique could be extended for human use in the field of rehabilitation for paralysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A nerve cuff technique for selective excitation of peripheral nerve trunk regions
Sweeney, J. D., Ksienski, D. A., & Mortimer, J. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55681 · Cited by 196
Chronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172
Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168
Multielectrode spiral cuff for ordered and reversed activation of nerve fibres
Rozman, J., Sovinec, B., Trlep, M., & Zorko, B. (1993) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(93)90039-2 · Cited by 41
Self-citation
Cited by
Yoo, P. B., & Durand, D. M. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851482 · Cited by 106
FitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73
Localization and Recovery of Peripheral Neural Sources With Beamforming Algorithms
Wodlinger, B., & Durand, D. M. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2034072 · Cited by 73
Stable Detection of Movement Intent From Peripheral Nerves: Chronic Study in Dogs
Dweiri, Y. M., Eggers, T. E., Gonzalez-Reyes, L. E., Drain, J., McCallum, G. A., & Durand, D. M. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2607520 · Cited by 44
“The quality of the recorded activity quantified by the SNR was also comparable to the multicontact round spiral cuffs used to record evoked sensory activity carried by the sciatic nerve in dogs in sedated nonmoving animals [31].”
BackgroundDweiri, Y. M., Stone, M. A., Tyler, D. J., McCallum, G. A., & Durand, D. M. (2016) · Journal of Visualized Experiments · doi:10.3791/54388 · Cited by 23
Metadata
- Authors
- Rozman, J., Zorko, B., & Bunc, M.
- Venue
- The Japanese Journal of Physiology
- Publisher
- Physiological Society of Japan
- Published
- 2000
- Volume
- 50
- Issue
- 5
- Pages
- 509-514
- ISSN
- 0021-521X (ISSN-L)
- OpenAlex
- W2055461564
- Cited by
- 34
- References
- 4
- FWCI
- 0.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.