Estimating Physical Activity and Sedentary Behavior in a Free-Living Context: A Pragmatic Comparison of Consumer-Based Activity Trackers and ActiGraph Accelerometry
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Activity trackers are increasingly popular with both consumers and researchers for monitoring activity and for promoting positive behavior change. However, there is a lack of research investigating the performance of these devices in free-living contexts, for which findings are likely to vary from studies conducted in well-controlled laboratory settings. OBJECTIVE: The aim was to compare Fitbit One and Jawbone UP estimates of steps, moderate-to-vigorous physical activity (MVPA), and sedentary behavior with data from the ActiGraph GT3X+ accelerometer in a free-living context. METHODS: Thirty-two participants were recruited using convenience sampling; 29 provided valid data for this study (female: 90%, 26/29; age: mean 39.6, SD 11.0 years). On two occasions for 7 days each, participants wore an ActiGraph GT3X+ accelerometer on their right hip and either a hip-worn Fitbit One (n=14) or wrist-worn Jawbone UP (n=15) activity tracker. Daily estimates of steps and very active minutes were derived from the Fitbit One (n=135 days) and steps, active time, and longest idle time from the Jawbone UP (n=154 days). Daily estimates of steps, MVPA, and longest sedentary bout were derived from the corresponding days of ActiGraph data. Correlation coefficients and Bland-Altman plots with examination of systematic bias were used to assess convergent validity and agreement between the devices and the ActiGraph. Cohen's kappa was used to assess the agreement between each device and the ActiGraph for classification of active versus inactive (≥10,000 steps per day and ≥30 min/day of MVPA) comparable with public health guidelines. RESULTS: Correlations with ActiGraph estimates of steps and MVPA ranged between .72 and .90 for Fitbit One and .56 and .75 for Jawbone UP. Compared with ActiGraph estimates, both devices overestimated daily steps by 8% (Fitbit One) and 14% (Jawbone UP). However, mean differences were larger for daily MVPA (Fitbit One: underestimated by 46%; Jawbone UP: overestimated by 50%). There was systematic bias across all outcomes for both devices. Correlations with ActiGraph data for longest idle time (Jawbone UP) ranged from .08 to .19. Agreement for classifying days as active or inactive using the ≥10,000 steps/day criterion was substantial (Fitbit One: κ=.68; Jawbone UP: κ=.52) and slight-fair using the criterion of ≥30 min/day of MVPA (Fitbit One: κ=.40; Jawbone UP: κ=.14). CONCLUSIONS: There was moderate-strong agreement between the ActiGraph and both Fitbit One and Jawbone UP for the estimation of daily steps. However, due to modest accuracy and systematic bias, they are better suited for consumer-based self-monitoring (eg, for the public consumer or in behavior change interventions) rather than to evaluate research outcomes. The outcomes that relate to health-enhancing MVPA (eg, "very active minutes" for Fitbit One or "active time" for Jawbone UP) and sedentary behavior ("idle time" for Jawbone UP) should be used with caution by consumers and researchers alike.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 2×
“A valid day was defined as a minimum wear time of 10 hours/day, with non-wear time defined as 60 minutes or more of consecutive activity counts of zero, with a spike tolerance of 2 minutes and 100 counts/minute [22,23].”
MethodLetter to the Editor: Standardized use of the terms “sedentary” and “sedentary behaviours”
Networ, S. B. R. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h2012-024 · Cited by 1,873
Wilmot, E. G., Edwardson, C. L., Achana, F. A., Davies, M. J., Gorely, T., Gray, L. J., Khunti, K., Yates, T., & Biddle, S. J. H. (2012) · Diabetologia · doi:10.1007/s00125-012-2677-z · Cited by 1,789 · cited 1×
“The Jawbone UP is one of the few devices available on the market that reports on time spent idle and this is valuable because of the evidence base linking prolonged sedentary behavior to a range of adverse health outcomes [34].”
BackgroundSedentary time and cardio-metabolic biomarkers in US adults: NHANES 2003–06
Healy, G. N., Matthews, C. E., Dunstan, D. W., Winkler, E. A. H., & Owen, N. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq451 · Cited by 1,368 · cited 2×
“For all valid days, daily estimates of steps (steps/day), time spent in MVPA (minutes/day), and longest sedentary bout (minutes/day) were derived from the vertical axis data using ActiLife software version 6 (ActiGraph, Pensacola, FL, USA) using cutpoints of less than 100 counts/minute for sedentary [24] and more than…”
MethodSystematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232 · cited 1×
“In addition, no previous studies have investigated the sedentary behavior features of the Jawbone UP (eg, idle time) [18].”
BackgroundObjectively Measured Sedentary Time, Physical Activity, and Metabolic Risk
Healy, G. N., Wijndaele, K., Dunstan, D. W., Shaw, J. E., Salmon, J., Zimmet, P. Z., & Owen, N. (2008) · Diabetes Care · doi:10.2337/dc07-1795 · Cited by 1,100 · cited 2×
“Although this approach is commonly used in this field [5,24], future studies should consider using the activPAL (PAL Technologies Ltd, Glasgow, UK) device, a thigh-worn accelerometer/inclinometer that evaluates time spent sedentary based on posture rather than the cutpoint method [38].”
BackgroundMethodWearable Devices as Facilitators, Not Drivers, of Health Behavior Change
Patel, M. S., Asch, D. A., & Volpp, K. G. (2015) · JAMA · doi:10.1001/jama.2014.14781 · Cited by 808
Accuracy of Smartphone Applications and Wearable Devices for Tracking Physical Activity Data
Case, M. A., Burwick, H. A., Volpp, K. G., & Patel, M. S. (2015) · JAMA · doi:10.1001/jama.2014.17841 · Cited by 694
Cited by
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
“[34,49,52,73,80,88,90,92,93,98,100,102,103,110, 116-118,120-138] Ankle/foot, pant pocket, waist/hip, or wrist Discontinued 2012 One Fitbit”
BackgroundAccuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
Sember, V., Meh, K., Sorić, M., Starc, G., Rocha, P., & Jurak, G. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17197161 · Cited by 266
Piau, A., Wild, K., Mattek, N., & Kaye, J. (2019) · Journal of Medical Internet Research · doi:10.2196/12785 · Cited by 252
Wearable Activity Tracker Use Among Australian Adolescents: Usability and Acceptability Study
Ridgers, N. D., Timperio, A., Brown, H., Ball, K., Macfarlane, S., Lai, S. K., Richards, K., Mackintosh, K. A., McNarry, M. A., Foster, M., et al. (2018) · JMIR mHealth and uHealth · doi:10.2196/mhealth.9199 · Cited by 125
The Accuracy of Smart Devices for Measuring Physical Activity in Daily Life: Validation Study
(2018) · doi:10.2196/10972 · Cited by 93
The Use of Wearable Devices in Oncology Patients: A Systematic Review
Chow, R., Drkulec, H., Im, J. H. B., Tsai, J., Nafees, A., Kumar, S., Hou, T., Fazelzad, R., Leighl, N. B., Krzyzanowska, M., et al. (2024) · The Oncologist · doi:10.1093/oncolo/oyad305 · Cited by 85
St Fleur, R. G., St George, S. M., Leite, R., Kobayashi, M., Agosto, Y., & Jake-Schoffman, D. E. (2021) · JMIR mHealth and uHealth · doi:10.2196/23411 · Cited by 74
“Previous studies have also shown that commercially available trackers such as Fitbit devices often overestimate the time spent in MVPA compared with research-grade monitors [15,104,105].”
BackgroundMethodDegroote, L., Hamerlinck, G., Poels, K., Maher, C., Crombez, G., De Bourdeaudhuij, I., Vandendriessche, A., Curtis, R. G., & DeSmet, A. (2020) · JMIR mhealth and uhealth · doi:10.2196/16674 · Cited by 60
“Such trackers rarely monitor SB [16,17], which is why SB, although important in 24-hour movement behaviors, falls outside the scope of this paper.”
BackgroundMethodMeasuring Moderate-Intensity Exercise with the Apple Watch: Validation Study
Abt, G., Bray, J., & Benson, A. C. (2018) · JMIR Cardio · doi:10.2196/cardio.8574 · Cited by 21
“Although evidence on the validity and reliability of modern wearable devices with integrated screens to measure exercise and physical activity is increasing, no study has examined the accuracy of the Apple Watch for measuring MVPA.”
ResultInfluentialArunachalam, D., & Heit, M. H. (2020) · International Urogynecology Journal · doi:10.1007/s00192-020-04239-y · Cited by 20
“Common types of activity data from these devices include number of steps and amount of time spent in physical activity graded by intensity [16].”
Background
Metadata
- Authors
- Gomersall, S. R., Ng, N., Burton, N. W., Pavey, T. G., Gilson, N. D., & Brown, W. J.
- Venue
- Journal of Medical Internet Research
- Publisher
- JMIR Publications Inc.
- Published
- 2016-09-07
- Volume
- 18
- Issue
- 9
- Pages
- e239
- ISSN
- 1438-8871 (ISSN-L)
- OpenAlex
- W2513273491
- Cited by
- 90
- References
- 20
- FWCI
- 8.44
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.