CoChat

Mobile Phone-Connected Wearable Motion Sensors to Assess Postoperative Mobilization

Open access
Appelboom, Geoff, Taylor, Blake E, Bruce, Eliza, Bassile, Clare C, Malakidis, Corinna, Yang, Annie, Youngerman, Brett, D'Amico, Randy, Bruce, Sam, Bruyère, Olivier, Reginster, Jean-Yves, Dumont, Emmanuel PL, Connolly Jr, E Sander · 2015 · JMIR mHealth and uHealth
Cited by 36

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Early mobilization after surgery reduces the incidence of a wide range of complications. Wearable motion sensors measure movements over time and transmit this data wirelessly, which has the potential to monitor patient recovery and encourages patients to engage in their own rehabilitation. OBJECTIVE: We sought to determine the ability of off-the-shelf activity sensors to remotely monitor patient postoperative mobility. METHODS: Consecutive subjects were recruited under the Department of Neurosurgery at Columbia University. Patients were enrolled during physical therapy sessions. The total number of steps counted by the two blinded researchers was compared to the steps recorded on four activity sensors positioned at different body locations. RESULTS: A total of 148 motion data points were generated. The start time, end time, and duration of each walking session were accurately recorded by the devices and were remotely available for the researchers to analyze. The sensor accuracy was significantly greater when placed over the ankles than over the hips (P<.001). Our multivariate analysis showed that step length was an independent predictor of sensor accuracy. On linear regression, there was a modest positive correlation between increasing step length and increased ankle sensor accuracy (r=.640, r(2)=.397) that reached statistical significance on the multivariate model (P=.03). Increased gait speed also correlated with increased ankle sensor accuracy, although less strongly (r=.444, r(2)=.197). We did not note an effect of unilateral weakness on the accuracy of left- versus right-sided sensors. Accuracy was also affected by several specific measures of a patient's level of physical assistance, for which we generated a model to mathematically adjust for systematic underestimation as well as disease severity. CONCLUSIONS: We provide one of the first assessments of the accuracy and utility of widely available and wirelessly connected activity sensors in a postoperative patient population. Our results show that activity sensors are able to provide invaluable information about a patient's mobility status and can transmit this data wirelessly, although there is a systematic underestimation bias in more debilitated patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2196/mhealth.3785

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Appelboom, G., Taylor, B. E., Bruce, E., Bassile, C. C., Malakidis, C., Yang, A., Youngerman, B., D'Amico, R., Bruce, S., Bruyère, O., Reginster, J.-Y., Dumont, E. P., & Connolly Jr, E. S.
Venue
JMIR mHealth and uHealth
Published
2015-07-28
Volume
3
Issue
3
Pages
e78
ISSN
2291-5222 (ISSN-L)
OpenAlex
W2104318059
Cited by
36
References
10
FWCI
1.73
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.