The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
ADC Measurement of Abdominal Organs and Lesions Using Parallel Imaging Technique
Abstract
OBJECTIVE: The purpose of our study was to assess the reliability and usefulness of parallel imaging for apparent diffusion coefficient (ADC) measurement of abdominal organs and lesions. MATERIALS AND METHODS: Single-shot spin-echo echo-planar diffusion-weighted MRI (TE = 66, b = 0, 600 s/mm2) was performed in phantom and clinical studies. The b value was set to minimize the effects of perfusion in tissue and to maintain signal-to-noise ratio. Bottle phantoms were scanned with and without parallel imaging and with various parallel imaging factors and at various positions to evaluate the effects of parallel imaging on ADCs. In 200 consecutive clinical patients (122 men and 78 women: mean age, 61.9 years), ADCs were calculated for liver (four segments), spleen, pancreas (head, body, tail), gallbladder, renal parenchyma, and back muscle, and then compared to evaluate the reliability of clinical ADC measurements with parallel imaging. ADCs were also calculated for diffuse diseases and focal lesions (94 malignant and 93 benign) of abdominal organs to evaluate the clinical usefulness of ADC. RESULTS: Location-dependent changes in water ADCs were minimal with parallel imaging factors first of 3, then of 4, and were small except for measurements at the image periphery. Acetone ADCs were saturated at 4.00 x 10(-3) mm2/s. Degraded image quality prevented ADC measurement of the left hepatic lobe and pancreas in 7-18 patients. There was no significant difference among ADCs of four liver segments (1.50 +/- 0.24 [SD] x 10(-3) mm2/s - 1.56 +/- 0.31 x 10(-3) mm2/s) and between ADCs of the right and left kidneys (2.65 +/- 0.30 x 10(-3) mm2/s, 2.59 +/- 0.33 x 10(-3) mm2/s). ADC of the pancreas tail (1.65 +/- 0.37 x 10(-3) mm2/s) was significantly lower than those of the head (1.81 +/- 0.40 x 10(-3) mm2/s) and body (1.81 +/- 0.41 x 10(-3) mm2/s) (p < 0.005). Renal ADCs were significantly lower in patients with renal failure (right: 2.15 +/- 0.30 x 10(-3) mm2/s; left: 2.11 +/- 0.25 x 10(-3) mm2/s) than in those without disease (right: 2.67 +/- 0.29 x 10(-3) mm2/s; left: 2.60 +/- 0.32 x 10(-3) mm2/s) (p < 0.005). ADC of pancreatic cancer was significantly higher than that of healthy pancreas (p < 0.05). ADC of renal angiomyolipoma was significantly lower than those of renal cell carcinoma and healthy renal parenchyma (p < 0.0005). CONCLUSION: Clinical ADC measurements of abdominal organs and lesions using parallel imaging appear to be reliable and useful, and the effect of parallel imaging on calculated values is considered to be minimal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Wai, C.-T., Greenson, J. K., Fontana, R. J., Kalbfleisch, J. D., Marrero, J. A., Conjeevaram, H. S., & Lok, A. S.-F. (2003) · Hepatology · doi:10.1053/jhep.2003.50346 · Cited by 4,406
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Taouli, B., Vilgrain, V., Dumont, E., Daire, J.-L., Fan, B., & Menu, Y. (2003) · Radiology · doi:10.1148/radiol.2261011904 · Cited by 577
Yamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519
Diffusion-weighted single-shot echoplanar MR imaging for liver disease.
Kim, T., Murakami, T., Takahashi, S., Hori, M., Tsuda, K., & Nakamura, H. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.173.2.10430143 · Cited by 349
Focal liver masses: characterization with diffusion-weighted echo-planar MR imaging.
Namimoto, T., Yamashita, Y., Sumi, S., Tang, Y., & Takahashi, M. (1997) · Radiology · doi:10.1148/radiology.204.3.9280252 · Cited by 349
Ichikawa, T., Haradome, H., Hachiya, J., Nitatori, T., & Araki, T. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.2.9456953 · Cited by 314
Bammer, R., Keeling, S. L., Augustin, M., Pruessmann, K. P., Wolf, R., Stollberger, R., Hartung, H., & Fazekas, F. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1226 · Cited by 311
Diffusion tensor imaging using single‐shot SENSE‐EPI
Bammer, R., Auer, M., Keeling, S. L., Augustin, M., Stables, L. A., Prokesch, R. W., Stollberger, R., Moseley, M. E., & Fazekas, F. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10184 · Cited by 279
Diffusion tensor MRI of the human kidney
Ries, M., Jones, R. A., Basseau, F., Moonen, C. T. W., & Grenier, N. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1149 · Cited by 236
Abdomen: Diffusion-weighted MR Imaging with Pulse-triggered Single-Shot Sequences
Mürtz, P., Flacke, S., Träber, F., van den Brink, J. S., Gieseke, J., & Schild, H. H. (2002) · Radiology · doi:10.1148/radiol.2241011117 · Cited by 222
Diffusion-weighted MRI in the evaluation of renal lesions: preliminary results
Cova, M., Squillaci, E., Stacul, F., Manenti, G., Gava, S., Simonetti, G., & Pozzi-Mucelli, R. (2004) · The British Journal of Radiology · doi:10.1259/bjr/26525081 · Cited by 213
Practical Aspects of Assessing Tumors Using Clinical Diffusion-weighted Imaging in the Body
KOH, D.-M., TAKAHARA, T., IMAI, Y., & COLLINS, D. J. (2007) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.6.211 · Cited by 211
Cirrhosis: Modified Caudate–Right Lobe Ratio
Awaya, H., Mitchell, D. G., Kamishima, T., Holland, G., Ito, K., & Matsumoto, T. (2002) · Radiology · doi:10.1148/radiol.2243011495 · Cited by 196
Self-citationIchikawa, T., Haradome, H., Hachiya, J., Nitatori, T., & Araki, T. (1999) · Abdominal Imaging · doi:10.1007/s002619900539 · Cited by 173
Taouli, B. A., Martin, A. J., Qayyum, A., Merriman, R. B., Vigneron, D. B., Yeh, B. M., & Coakley, F. V. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.3.1830677 · Cited by 134
Diffusion-weighted MR imaging in the evaluation of renal tumours.
Squillaci, E., Manenti, G., Stefano, F. D., Miano, R., Strigari, L., & Simonetti, G. (2004) · PubMed · Cited by 126
MR diffusion-weighted imaging of kidney
Chan, J. H. M., Tsui, E. Y. K., Luk, S. H., Fung, S. L., Cheung, Y. K., Chan, M. S. M., Yuen, M. K., Mak, S. F., & Wong, K. P. C. (2001) · Clinical Imaging · doi:10.1016/s0899-7071(01)00246-7 · Cited by 114
Single breath‐hold diffusion‐weighted imaging of the abdomen
Chow, L. C., Bammer, R., Moseley, M. E., & Sommer, F. G. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10353 · Cited by 95
Invited. Ultrafast MR imaging of the abdomen: Echo planar imaging and diffusion‐weighted imaging
Yamashita, Y., Tang, Y., & Takahashi, M. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080216 · Cited by 92
Yamashita, Y., Namimoto, T., Mitsuzaki, K., Urata, J., Tsuchigame, T., Takahashi, M., & Ogawa, M. (1998) · Radiology · doi:10.1148/radiology.208.3.9722835 · Cited by 71
Chiu, F.-Y., Jao, J., Chen, C., Liu, G.-C., Jaw, T., Chiou, Y., Hsu, F.-O., & Hsu, J. (2005) · Journal of Computer Assisted Tomography · doi:10.1097/01.rct.0000157472.98277.5c · Cited by 68
Feasibility of MR Diffusion Studies in the Kidney
Siegel, C. L., Aisen, A. M., Ellis, J. H., Londy, F. J., & Chenevert, T. L. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050523 · Cited by 60
Moteki, T., Horikoshi, H., Oya, N., Aoki, J., & Endo, K. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10101 · Cited by 53
Coil Sensitivity Encoding in MR Imaging: Advantages and Disadvantages in Clinical Practice
Kurihara, Y., Yakushiji, Y. K., Tani, I., Nakajima, Y., & CAUTEREN, M. V. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.5.1781087 · Cited by 53
Influence of Imaging Parameters on the Measurement of Apparent Diffusion Coefficient
Ozaki, M., Ogura, A., Muro, I., Miyati, T., Tamura, T., Takahashi, M., Doi, T., Tanji, H., Takahashi, J., & Takizawa, O. (2010) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.66.1178 · Cited by 12
Cited by
Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations
Padhani, A. R., Liu, G., Mu-Koh, D., Chenevert, T. L., Thoeny, H. C., Takahara, T., Dzik-Jurasz, A., Ross, B. D., Van Cauteren, M., Collins, D., et al. (2009) · Neoplasia · doi:10.1593/neo.81328 · Cited by 1,989
Parikh, T., Drew, S. J., Lee, V. S., Wong, S., Hecht, E. M., Babb, J. S., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070432 · Cited by 560
Kwee, T. C., Takahara, T., Ochiai, R., Nievelstein, R. A. J., & Luijten, P. R. (2008) · European Radiology · doi:10.1007/s00330-008-0968-z · Cited by 410
Renal Lesions: Characterization with Diffusion-weighted Imaging versus Contrast-enhanced MR Imaging
Taouli, B., Thakur, R. K., Mannelli, L., Babb, J. S., Kim, S., Hecht, E. M., Lee, V. S., & Israel, G. M. (2009) · Radiology · doi:10.1148/radiol.2512080880 · Cited by 322
Fujii, S., Kakite, S., Nishihara, K., Kanasaki, Y., Harada, T., Kigawa, J., Kaminou, T., & Ogawa, T. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21575 · Cited by 159
Metadata
- Authors
- Yoshikawa, T., Kawamitsu, H., Mitchell, D. G., Ohno, Y., Ku, Y., Seo, Y., Fujii, M., & Sugimura, K.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2006-12
- Volume
- 187
- Issue
- 6
- Pages
- 1521-1530
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1987156073
- Cited by
- 300
- References
- 27
- FWCI
- 14.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.