Intravoxel Incoherent Motion in Body Diffusion-Weighted MRI: Reality and Challenges
The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Diffusion-weighted MRI is increasingly applied in the body. It has been recognized for some time, on the basis of scientific experiments and studies in the brain, that the calculation of apparent diffusion coefficient by simple monoexponential relationship between MRI signal and b value does not fully account for tissue behavior. However, appreciation of this fact in body diffusion MRI is relatively new, because technologic advancements have only recently enabled high-quality body diffusion-weighted images to be acquired using multiple b values. There is now increasing interest in the radiologic community to apply more sophisticated analytic approaches, such as those based on the principles of intravoxel incoherent motion, which allows quantitative parameters that reflect tissue microcapillary perfusion and tissue diffusivity to be derived. CONCLUSION: In this review, we discuss the principles of intravoxel incoherent motion as applied to body diffusion-weighted MRI. The evidence for the technique in measuring tissue perfusion is presented and the emerging clinical utility surveyed. The requisites and challenges of quantitative evaluation beyond simple monoexponential relationships are highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912 · cited 3×
“[3] proposed the principles of intravoxel incoherent motion (IVIM) and suggested that using a more sophisticated approach to describe the relationship between signal attenuation in tissues with increasing b value would enable quantitative parameters that separately reflect tissue diffusivity and tissue microcapillary…”
BackgroundMethodSeparation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488 · cited 1×
“These include a stretched exponential model [44], a gaussian model [45], and a model that includes diffusion and kurtosis (skewness of distribution) [46].”
MethodDiffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Koh, D.-M., & Collins, D. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1403 · Cited by 1,993
Self-citationBasic principles of diffusion-weighted imaging
Bammer, R. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00303-0 · Cited by 851
Takahara, T., Imai, Y., Yamashita, T., Yasuda, S., Nasu, S., & CAUTEREN, M. V. (2004) · PubMed · Cited by 781
Liver Cirrhosis: Intravoxel Incoherent Motion MR Imaging—Pilot Study
Luciani, A., Vignaud, A., Cavet, M., Tran Van Nhieu, J., Mallat, A., Ruel, L., Laurent, A., Deux, J.-F., Brugieres, P., & Rahmouni, A. (2008) · Radiology · doi:10.1148/radiol.2493080080 · Cited by 612
A Fourier method for the analysis of exponential decay curves
Provencher, S. W. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85660-3 · Cited by 594
Yamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519
Cited by
What can we see with IVIM MRI?
Le Bihan, D. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.062 · Cited by 498
Diffusion weighted imaging: Technique and applications
Baliyan, V., Das, C. J., Sharma, R., & Gupta, A. K. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i9.785 · Cited by 395
Rosenkrantz, A. B., Padhani, A. R., Chenevert, T. L., Koh, D., De Keyzer, F., Taouli, B., & Le Bihan, D. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24985 · Cited by 381
Self-citationAndreou, A., Koh, D. M., Collins, D. J., Blackledge, M., Wallace, T., Leach, M. O., & Orton, M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2604-1 · Cited by 287
Self-citationSigmund, E. E., Vivier, P.-H., Sui, D., Lamparello, N. A., Tantillo, K., Mikheev, A., Rusinek, H., Babb, J. S., Storey, P., Lee, V. S., et al. (2012) · Radiology · doi:10.1148/radiol.12111327 · Cited by 226
Diffusion‐weighted imaging outside the brain: Consensus statement from an ISMRM‐sponsored workshop
Taouli, B., Beer, A. J., Chenevert, T., Collins, D., Lehman, C., Matos, C., Padhani, A. R., Rosenkrantz, A. B., Shukla‐Dave, A., Sigmund, E., et al. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25196 · Cited by 175
“sitizes the diffusion measurement to capillary perfusion and other flow phenomena.(34)”
Self-citationKang, K. M., Lee, J. M., Yoon, J. H., Kiefer, B., Han, J. K., & Choi, B. I. (2014) · Radiology · doi:10.1148/radiol.13122712 · Cited by 162
“Therefore, referencing the recommendations of Koh et al (21) and Lemke (24) that a minimum number of b values used for IVIM DW imaging could be eight and 10, respectively, we used 10 b values in total and six b values lower than 200 sec/mm2.”
MethodEffect of inaccurate b-values from imaging gradients on intravoxel incoherent motion
Rashid, I. A., Szczepankiewicz, F., Gunnlaugsson, A., Olsson, L. E., & Brynolfsson, P. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30579 · Cited by 8
“3 Despite this, it is recognized to have several promising applications throughout the body, 1,3,4 prompting efforts to improve the reliability of IVIM parameter estimates.”
Metadata
- Authors
- Koh, D.-M., Collins, D. J., & Orton, M. R.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2011-06
- Volume
- 196
- Issue
- 6
- Pages
- 1351-1361
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2167594413
- Cited by
- 527
- References
- 55
- FWCI
- 24.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.