The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Intravoxel Incoherent Motion in Body Diffusion-Weighted MRI: Reality and Challenges
Abstract
OBJECTIVE: Diffusion-weighted MRI is increasingly applied in the body. It has been recognized for some time, on the basis of scientific experiments and studies in the brain, that the calculation of apparent diffusion coefficient by simple monoexponential relationship between MRI signal and b value does not fully account for tissue behavior. However, appreciation of this fact in body diffusion MRI is relatively new, because technologic advancements have only recently enabled high-quality body diffusion-weighted images to be acquired using multiple b values. There is now increasing interest in the radiologic community to apply more sophisticated analytic approaches, such as those based on the principles of intravoxel incoherent motion, which allows quantitative parameters that reflect tissue microcapillary perfusion and tissue diffusivity to be derived. CONCLUSION: In this review, we discuss the principles of intravoxel incoherent motion as applied to body diffusion-weighted MRI. The evidence for the technique in measuring tissue perfusion is presented and the emerging clinical utility surveyed. The requisites and challenges of quantitative evaluation beyond simple monoexponential relationships are highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488 · cited 1×
“These include a stretched exponential model [44], a gaussian model [45], and a model that includes diffusion and kurtosis (skewness of distribution) [46].”
MethodDiffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Koh, D.-M., & Collins, D. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1403 · Cited by 1,993
Self-citationBasic principles of diffusion-weighted imaging
Bammer, R. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00303-0 · Cited by 851
Takahara, T., Imai, Y., Yamashita, T., Yasuda, S., Nasu, S., & CAUTEREN, M. V. (2004) · PubMed · Cited by 781
Liver Cirrhosis: Intravoxel Incoherent Motion MR Imaging—Pilot Study
Luciani, A., Vignaud, A., Cavet, M., Tran Van Nhieu, J., Mallat, A., Ruel, L., Laurent, A., Deux, J.-F., Brugieres, P., & Rahmouni, A. (2008) · Radiology · doi:10.1148/radiol.2493080080 · Cited by 612
A Fourier method for the analysis of exponential decay curves
Provencher, S. W. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85660-3 · Cited by 594
Yamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519
Bennett, K. M., Schmainda, K. M., Bennett (Tong), R., Rowe, D. B., Lu, H., & Hyde, J. S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10581 · Cited by 467
The capillary network: A link between IVIM and classical perfusion
Bihan, D. L., & Turner, R. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270116 · Cited by 423 · cited 1×
“However, Le Bihan and Turner [19] reasoned that, even with the use of freely diffusible tracers, the delivery of tracer to tissues is still dependent on intravascular flow and there is thus highly likely to be a relationship between tissue perfusion measured using DW-MRI and tissue perfusion measured using tracer kine…”
Patel, J., Sigmund, E. E., Rusinek, H., Oei, M., Babb, J. S., & Taouli, B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22081 · Cited by 371
Intravoxel Incoherent Motion Perfusion MR Imaging: A Wake-Up Call
Le Bihan, D. (2008) · Radiology · doi:10.1148/radiol.2493081301 · Cited by 298
Le Bihan, D., Turner, R., Moonen, C. T. W., & Pekar, J. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010103 · Cited by 288
Andreou, A., Koh, D. M., Collins, D. J., Blackledge, M., Wallace, T., Leach, M. O., & Orton, M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2604-1 · Cited by 287
Self-citationLemke, A., Laun, F. B., Simon, D., Stieltjes, B., & Schad, L. R. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22565 · Cited by 266
Diffusion tensor MRI of the human kidney
Ries, M., Jones, R. A., Basseau, F., Moonen, C. T. W., & Grenier, N. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1149 · Cited by 236
Statistical model for diffusion attenuated MR signal
Yablonskiy, D. A., Bretthorst, G. L., & Ackerman, J. J. H. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10578 · Cited by 233
Lemke, A., Laun, F. B., Klau, M., Re, T. J., Simon, D., Delorme, S., Schad, L. R., & Stieltjes, B. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181b62271 · Cited by 231
Sigmund, E. E., Vivier, P.-H., Sui, D., Lamparello, N. A., Tantillo, K., Mikheev, A., Rusinek, H., Babb, J. S., Storey, P., Lee, V. S., et al. (2012) · Radiology · doi:10.1148/radiol.12111327 · Cited by 226
Youk, J. H., Son, E. J., Chung, J., Kim, J.-A., & Kim, E.-K. (2012) · European Radiology · doi:10.1007/s00330-012-2425-2 · Cited by 221
Quantitative Measurement of Brain Perfusion with Intravoxel Incoherent Motion MR Imaging
Federau, C., Maeder, P., O’Brien, K., Browaeys, P., Meuli, R., & Hagmann, P. (2012) · Radiology · doi:10.1148/radiol.12120584 · Cited by 191
Dyvorne, H. A., Galea, N., Nevers, T., Fiel, M. I., Carpenter, D., Wong, E., Orton, M., de Oliveira, A., Feiweier, T., Vachon, M.-L., et al. (2013) · Radiology · doi:10.1148/radiol.12120686 · Cited by 182
Self-citationZhang, J. L., Sigmund, E. E., Chandarana, H., Rusinek, H., Chen, Q., Vivier, P.-H., Taouli, B., & Lee, V. S. (2010) · Radiology · doi:10.1148/radiol.09090891 · Cited by 179
Koh, D.-M., Blackledge, M., Collins, D. J., Padhani, A. R., Wallace, T., Wilton, B., Taylor, N. J., Stirling, J. J., Sinha, R., Walicke, P., et al. (2009) · European Radiology · doi:10.1007/s00330-009-1469-4 · Cited by 163
Self-citationOn the precision of diffusion/perfusion imaging by gradient sensitization
Pekar, J. J., MOONEN, C. T. W., & van Zijl, P. C. M. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230113 · Cited by 153
Wirestam, R., Borg, M., Brockstedt, S., Lindgren, A., Holtås, S., & Ståhlberg, F. (2001) · Acta Radiologica · doi:10.1034/j.1600-0455.2001.042002123.x · Cited by 146
Water diffusion in rat brain in vivo as detected at very large b values is multicompartmental
Pfeuffer, J., Provencher, S. W., & Rolf Gruetter, A. (1999) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf02590526 · Cited by 136
Koh, D., Scurr, E. D., Collins, D. J., Pirgon, A., Kanber, B., Karanjia, N. D., Brown, G. M., Leach, M. O., & Husband, J. E. (2006) · European Radiology · doi:10.1007/s00330-006-0201-x · Cited by 132
Self-citationRiches, S. F., Hawtin, K. E., Charles-Edwards, E., & de Souza, N. M. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1328 · Cited by 128
Liver fibrosis: An intravoxel incoherent motion (IVIM) study
Chow, A. M., Gao, D. S., Fan, S. J., Qiao, Z., Lee, F. Y., Yang, J., Man, K., & Wu, E. X. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23607 · Cited by 108
Biexponential apparent diffusion coefficients in prostate cancer
Shinmoto, H., Oshio, K., Tanimoto, A., Higuchi, N., Okuda, S., Kuribayashi, S., & Mulkern, R. V. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.07.008 · Cited by 105
A quantitative interpretation of IVIM measurements of vascular perfusion in the rat brain
Henkelman, R. M., Neil, J. J., & Xiang, Q. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320407 · Cited by 104
Does IVIM measure classical perfusion?
Henkelman, R. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160313 · Cited by 101
Single breath‐hold diffusion‐weighted imaging of the abdomen
Chow, L. C., Bammer, R., Moseley, M. E., & Sommer, F. G. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10353 · Cited by 95
Yoshino, N., Yamada, I., Ohbayashi, N., Honda, E., Ida, M., Kurabayashi, T., Maruyama, K., & Sasaki, T. (2001) · Radiology · doi:10.1148/radiol.2213010131 · Cited by 90
Intravoxel water diffusion heterogeneity imaging of human high‐grade gliomas
Kwee, T. C., Galbán, C. J., Tsien, C. I., Junck, L., Sundgren, P. C., Ivancevic, M. K., Johnson, T. D., Meyer, C. R., Rehemtulla, A., Ross, B. D., et al. (2009) · NMR in Biomedicine · doi:10.1002/nbm.1441 · Cited by 79
Freiman, M., Pérez-Rosselló, J. M., Callahan, M. J., Voss, S. D., Ecklund, K., Mulkern, R. V., & Warfield, S. K. (2013) · Medical Image Analysis · doi:10.1016/j.media.2012.12.001 · Cited by 75
Diffusion-weighted MR Imaging for Liver Lesion Characterization: A Critical Look
Taouli, B. A. (2012) · Radiology · doi:10.1148/radiol.11112417 · Cited by 72
Diffusion-Weighted Magnetic Resonance Imaging of the Pancreas
Balci, N. C., Perman, W. H., Sağlam, S., Akisik, F. M., Fattahi, R., & Bilgin, M. (2009) · Topics in Magnetic Resonance Imaging · doi:10.1097/rmr.0b013e3181b48667 · Cited by 70
Contemporary Imaging of the Renal Mass
Kang, S. K., & Chandarana, H. (2012) · Urologic Clinics of North America · doi:10.1016/j.ucl.2012.01.002 · Cited by 67
Kim, S. Y., Lee, S. S., Park, B., Kim, N., Kim, J. K., Park, S. H., Byun, J. H., Song, K., Koo, J. ‐., Choi, E. K., et al. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23744 · Cited by 66
Normal and Transplanted Rat Kidneys: Diffusion MR Imaging at 7 T
Yang, D., Ye, Q., Williams, D. S., Hitchens, T. K., & Ho, C. (2004) · Radiology · doi:10.1148/radiol.2313021587 · Cited by 66
Neil, J. J., Bosch, C. S., & Ackerman, J. J. H. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320109 · Cited by 57
Zhang, L., Murata, Y., Ishida, R., Ohashi, I., Yoshimura, R., & Shibuya, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1177 · Cited by 54
Renal artery stenosis: in vivo perfusion MR imaging.
Powers, T. A., Lorenz, C. H., Holburn, G. E., & Price, R. R. (1991) · Radiology · doi:10.1148/radiology.178.2.1987621 · Cited by 52
Freiman, M., Voss, S. D., Mulkern, R. V., Pérez-Rosselló, J. M., Callahan, M. J., & Warfield, S. K. (2012) · Medical Physics · doi:10.1118/1.4736516 · Cited by 47
IVIM method measures diffusion and perfusion.
Bihan, D. L. (1990) · PubMed · Cited by 47
Record of a single fMRI experiment in May of 1991
Kwong, K. K. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.089 · Cited by 40
Magnetic Resonance Perfusion/Diffusion Imaging of the Excised Dog Kidney
Pickens, D. R., JOLGREN, D. L., Lorenz, C. H., Creasy, J. L., & Price, R. R. (1992) · Investigative Radiology · doi:10.1097/00004424-199204000-00005 · Cited by 30
Magnetic Resonance Imaging of the Liver
Larson, R. E., & Semelka, R. C. (1995) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-199500720-00003 · Cited by 28
Wang, Z., Su, M., Najafi, A., & Nalcioğlu, O. (2001) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(01)00431-3 · Cited by 18
The characteristics of signal contrast for the focal hepatic masses with multi-b DWI
Guo, G., Zhu, L., Sun, Z., & Yang, W. (2012) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2012.6513022 · Cited by 1
Diffusion-weighted MRI techniques for the evaluation of focal hepatic lesions
Kocakoç, E., Onur, M. R., & Serter, A. (2012) · Imaging in Medicine · doi:10.2217/iim.12.48 · Cited by 1
Cited by
What can we see with IVIM MRI?
Le Bihan, D. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.062 · Cited by 498
Diffusion weighted imaging: Technique and applications
Baliyan, V., Das, C. J., Sharma, R., & Gupta, A. K. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i9.785 · Cited by 395
Rosenkrantz, A. B., Padhani, A. R., Chenevert, T. L., Koh, D., De Keyzer, F., Taouli, B., & Le Bihan, D. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24985 · Cited by 381
Self-citationAndreou, A., Koh, D. M., Collins, D. J., Blackledge, M., Wallace, T., Leach, M. O., & Orton, M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2604-1 · Cited by 287
Self-citationEffect of inaccurate b-values from imaging gradients on intravoxel incoherent motion
Rashid, I. A., Szczepankiewicz, F., Gunnlaugsson, A., Olsson, L. E., & Brynolfsson, P. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30579 · Cited by 8
Metadata
- Authors
- Koh, D.-M., Collins, D. J., & Orton, M. R.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2011-06
- Volume
- 196
- Issue
- 6
- Pages
- 1351-1361
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2167594413
- Cited by
- 527
- References
- 55
- FWCI
- 24.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.