CoChat

Pelvic and Lower Extremity Arterial Imaging: Diagnostic Performance of Three-Dimensional Contrast-Enhanced MR Angiography

Ruehm, Stefan G., Hany, Thomas F., Pfammatter, Thomas, Schneider, Ernst, Ladd, Mark, Debatin, Jörg F. · 2000 · American Journal of Roentgenology
Cited by 177

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The diagnostic performance of a three-dimensional MR angiography-based strategy was assessed with regard to its ability to characterize the arterial vasculature from the aortic bifurcation to the lower extremity runoff vessels. A single-injection, two-station protocol in combination with a lower-extremity vascular coil was used. SUBJECTS AND METHODS: Both conventional digital subtraction angiography and three-dimensional contrast-enhanced MR angiography with a dedicated peripheral vascular coil were performed in 61 patients with suspected peripheral vascular disease. In a prospective analysis, one reviewer evaluated the digital subtraction angiographic images and a second reviewer evaluated the MR angiographic images; both were unaware of the results of the other imaging technique. Each vascular segment (29 segments per patient) was evaluated for the presence of occlusive vessel disease. The following grading system was applied: 0, normal; 1, vessel irregularity with a luminal reduction of less than 10%; 2, mild stenosis (lumen reduction, 10-49%); 3, severe stenosis (lumen reduction, 50-99%); and 4, occlusion (lumen reduction, 100%). In 11 patients surgical graft patency was assessed. RESULTS: MR angiography provided an image quality comparable with that of digital subtraction angiography. Overall sensitivity and specificity for MR angiography were 92% and 96.6%, respectively, for the detection of hemodynamically significant disease and 92.3% and 99.4%, respectively, for the detection of occlusions. CONCLUSION: Two-station contrast-enhanced three-dimensional MR angiography with a dedicated lower-extremity vascular coil proved effective enough to consider it as a noninvasive alternative to digital subtraction angiography in the assessment of the pelvic and lower extremity arterial vasculature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.174.4.1741127

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

Metadata

Authors
Ruehm, S. G., Hany, T. F., Pfammatter, T., Schneider, E., Ladd, M., & Debatin, J. F.
Venue
American Journal of Roentgenology
Published
2000-04
Volume
174
Issue
4
Pages
1127-1135
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2165936389
Cited by
177
References
17
FWCI
21.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.