The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Abstract
OBJECTIVE: In light of the rapidly increasing frequency of pediatric CT examinations, the purpose of our study was to assess the lifetime cancer mortality risks attributable to radiation from pediatric CT. MATERIALS AND METHODS: Organ doses as a function of age-at-diagnosis were estimated for common CT examinations, and estimated attributable lifetime cancer mortality risks (per unit dose) for different organ sites were applied. Standard models that assume a linear extrapolation of risks from intermediate to low doses were applied. On the basis of current standard practice, the same exposures (milliampere-seconds) were assumed, independent of age. RESULTS: The larger doses and increased lifetime radiation risks in children produce a sharp increase, relative to adults, in estimated risk from CT. Estimated lifetime cancer mortality risks attributable to the radiation exposure from a CT in a 1-year-old are 0.18% (abdominal) and 0.07% (head)-an order of magnitude higher than for adults-although those figures still represent a small increase in cancer mortality over the natrual background rate. In the United States, of approximately 600,000 abdominal and head CT examinations annually performed in children under the age of 15 years, a rough estimate is that 500 of these individuals might ultimately die from cancer attributable to the CT radiation. CONCLUSION: The best available risk estimates suggest that pediatric CT will result in significantly increased lifetime radiation risk over adult CT, both because of the increased dose per milliampere-second, and the increased lifetime risk per unit dose. Lower milliampere-second settings can be used for children without significant loss of information. Although the risk-benefit balance is still strongly tilted toward benefit, because the frequency of pediatric CT examinations is rapidly increasing, estimates that quantitative lifetime radiation risks for children undergoing CT are not negligible may stimulate more active reduction of CT exposure settings in pediatric patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Brenner et al. concluded already in 2001 that paediatric CT scans significantly increase the lifetime risk of cancer mortality due to the higher radiation sensitivity of children”
From Developments in diagnostic and surgical techniques in children with sagittal suture craniosynostosis: a systematic review spanning the last 30 years (2025) · cites this paper as [66]
Citations
Cites
Sources and effects of ionizing radiation
United Nations Scientific Committee on the Effects of Atomic Radiation (2018) · Report of the United Nations Scientific Committee on the Effects of Atomic Radiation · doi:10.18356/f48d655d-en · Cited by 3,981
International Commission on Radiological Protection
(1969) · Radiology · doi:10.1148/93.6.1298 · Cited by 2,148
Thyroid Cancer after Exposure to External Radiation: A Pooled Analysis of Seven Studies
Ron, E., Lubin, J. H., Shore, R. E., Mabuchi, K., Modan, B., Pottern, L. M., Schneider, A. B., Tucker, M. A., & Boice, J. D. (2012) · Radiation Research · doi:10.1667/rrav05.1 · Cited by 1,124
Thyroid Cancer after Exposure to External Radiation: A Pooled Analysis of Seven Studies
Ron, E., Lubin, J. H., Shore, R. E., Mabuchi, K., Modan, B., Pottern, L. M., Schneider, A. B., Tucker, M. A., & Boice, J. D. (1995) · Radiation Research · doi:10.2307/3579003 · Cited by 1,107 · cited 1×
“The risk estimates given here are for lifetime cancer mortality; estimated cancer risks from pediatric CT examinations would, by definition, be larger, particularly for CT examinations of the head, because of the larger contribution of radiation-induced thyroid cancer [34].”
BackgroundStudies of the Mortality of Atomic Bomb Survivors. Report 12, Part I. Cancer: 1950-1990
Pierce, D. A., Shimizu, Y., Preston, D. L., Væth, M., & Mabuchi, K. (1996) · Radiation Research · doi:10.2307/3579391 · Cited by 938
Risk of childhood cancer from fetal irradiation.
Doll, R., & Wakeford, R. (1997) · British Journal of Radiology · doi:10.1259/bjr.70.830.9135438 · Cited by 683
Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative
Brenner, D. J. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0671-1 · Cited by 555
Self-citationHealth effects of exposure to low levels of ionizing radiation
Schonken, P. (1991) · Health Policy · doi:10.1016/0168-8510(91)90028-v · Cited by 530
National Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 381
Research works printed but not linked: 2
- Chamberlain C, Huda W, Rosenbaum A, Garissi W. Adult and pediatric radiation doses in head CT examinations. (abstr) Med Phys 1998; 25:A216
- National Council on Radiation Protection and Measurements. Evaluation of the linear non-threshold dose-response model. Bethesda, MD: NCRP Publications, 2000 (in press)
Cited by
Sorted by citations
Items 401–500 of 1,005
Automated Mesiodens Classification System Using Deep Learning on Panoramic Radiographs of Children
Ahn, Y., Hwang, J. J., Jung, Y., Jeong, T.-S., & Shin, J. (2021) · Diagnostics · doi:10.3390/diagnostics11081477 · Cited by 75
Reid, J. R., Gamberoni, J., Dong, F. F., & Davros, W. J. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.3862 · Cited by 75
Menaker, J. A., Blumberg, S., Wisner, D. H., Dayan, P. S., Tunik, M. G., Garcia, M., Mahajan, P., Page, K., Monroe, D. J., Borgialli, D. A., et al. (2014) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0000000000000296 · Cited by 75
Assessment of paediatric CT dose indicators for the purpose of optimisation
Brady, Z., Ramanauskas, F., Cain, T. M., & Johnston, P. N. (2012) · British Journal of Radiology · doi:10.1259/bjr/28015185 · Cited by 75
Lawrance, I. C., Welman, C. J., Shipman, P. J., & Murray, K. (2009) · World Journal of Gastroenterology · doi:10.3748/wjg.15.3367 · Cited by 75
Villegas, V. M., Hess, D. J., Wildner, A. C., Gold, A. S., & Murray, T. G. (2013) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000000002 · Cited by 75
Updated Australian diagnostic reference levels for adult CT
Lee, K. L., Beveridge, T., Sanagou, M., & Thomas, P. (2020) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.372 · Cited by 75
Evaluation of a Radiation Dose Reduction Strategy for Pediatric Chest CT
Kim, J., & Newman, B. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.3726 · Cited by 74
Knowledge of medical imaging radiation dose and risk among doctors
Brown, N. I., & Jones, L. V. (2012) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/j.1754-9485.2012.02469.x · Cited by 74
Hollingworth, W., Vavilala, M. S., Jarvik, J. G., Chaudhry, S., Johnston, B., Layman, S., Tontisirin, N., Muangman, S. L., & Wang, M. C. (2007) · Pediatric Critical Care Medicine · doi:10.1097/01.pcc.0000270837.66217.3b · Cited by 74
Reducing radiation dose in emergency computed tomography with automatic exposure control techniques
Kalra, M. K., Rizzo, S., & Novelline, R. A. (2005) · Emergency Radiology · doi:10.1007/s10140-004-0395-7 · Cited by 74
Blankman, P., Shono, A., Hermans, B. J. M., Wesselius, T., Hasan, D., & Gommers, D. A. M. P. J. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew116 · Cited by 87
Pediatric multidetector body CT
Donnelly, L. F., & Frush, D. P. (2003) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(03)00036-8 · Cited by 74
Sahbaee, P., Segars, W. P., & Samei, E. (2014) · Medical Physics · doi:10.1118/1.4883778 · Cited by 73
Diagnostic imaging in the management of craniosynostoses
Kotrikova, B., Krempien, R. C., Freier, K., & Mühling, J. (2006) · European Radiology · doi:10.1007/s00330-006-0520-y · Cited by 73
Manual of Emergency and Critical Care Ultrasound
Noble, V. E., & Nelson, B. P. (2011) · Cambridge University Press eBooks · doi:10.1017/cbo9780511734281 · Cited by 73
Novel Applications of Ultrasound in Pediatric Emergency Medicine
Chen, L., & Baker, M. D. (2007) · Pediatric Emergency Care · doi:10.1097/pec.0b013e3180302c59 · Cited by 72
Wafer-Scale Photolithography-Pixeled Pb-Free Perovskite X-ray Detectors
Dun, G., Zhang, H., Qin, K., Tan, X., Zhao, R., Chen, M., Huang, Y., Geng, X., Li, Y.-Y., Li, Y., et al. (2022) · ACS Nano · doi:10.1021/acsnano.2c01074 · Cited by 72
Bedside Ultrasound in the Diagnosis of Pediatric Clavicle Fractures
Chien, M., Bulloch, B., Garcia-Filion, P. C., Youssfi, M., Shrader, M. W., & Segal, L. S. (2011) · Pediatric Emergency Care · doi:10.1097/pec.0b013e318235e965 · Cited by 72
O’Sullivan, J., O’Connor, O. J., O'Regan, K. N., Clarke, B., Burgoyne, L. N., Ryan, M. F., & Maher, M. M. (2010) · Insights into Imaging · doi:10.1007/s13244-010-0009-8 · Cited by 72
Perisinakis, K., Raissaki, M., Damilakis, J. E., Stratakis, J., Neratzoulakis, J., & Gourtsoyiannis, N. (2005) · European Radiology · doi:10.1007/s00330-005-0072-6 · Cited by 72
Keckler, S. J., Tsao, K., Sharp, S. W., Ostlie, D. J., Holcomb, G. W., III, & Peter, S. D. S. (2008) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2008.02.019 · Cited by 72
Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation
Goo, H. W., & Suh, D. S. (2006) · Pediatric Radiology · doi:10.1007/s00247-005-0105-y · Cited by 72
Paediatric CT examinations in 19 developing countries: frequency and radiation dose
Muhogora, W. E., Ahmed, N. A., AlSuwaidi, J. S., Beganović, A., Ciraj‐Bjelac, O., Gershan, V., Gershkevitsh, E., Gruppetta, E., Kharita, M. H., Manatrakul, N., et al. (2010) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncq015 · Cited by 72
Schuh, S., Chan, K. J., Langer, J. C., Kulik, D. M., Preto‐Zamperlini, M., Al-Aswad, N., Man, C., Mohanta, A., Stephens, D., & Doria, A. S. (2015) · Academic Emergency Medicine · doi:10.1111/acem.12631 · Cited by 72
Individually Adapted Examination Protocols for Reduction of Radiation Exposure in Chest CT
Wildberger, J. E., Mahnken, A. H., Schmitz‐Rode, T., Flohr, T. G., Stargardt, A., Haage, P., SCHALLER, S., & Günther, R. W. (2001) · Investigative Radiology · doi:10.1097/00004424-200110000-00006 · Cited by 72
Optimization of Pediatric PET/CT
Parisi, M. T., Bermo, M. S., Alessio, A. M., Sharp, S. E., Gelfand, M. J., & Shulkin, B. L. (2017) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2017.01.002 · Cited by 71
Craniocervical Arterial Dissection in Children: Diagnosis and Treatment
Stence, N. V., Fenton, L. Z., Goldenberg, N. A., Armstrong, J., & Bernard, T. J. (2011) · Current Treatment Options in Neurology · doi:10.1007/s11940-011-0149-2 · Cited by 71
The Value of Scheduled Repeat Cranial Computed Tomography After Mild Head Injury
Almenawer, S. A., Bogza, I., Yarascavitch, B. A., Sne, N., Farrokhyar, F., Murty, N., & Reddy, K. K. V. (2012) · Neurosurgery · doi:10.1227/neu.0b013e318276f899 · Cited by 71
Pediatric Radiation Exposure During the Initial Evaluation for Blunt Trauma
Mueller, D. L., Hatab, M. R., Al‐Senan, R., Cohn, S. M., Corneille, M. G., Dent, D. L., Michalek, J. E., Myers, J. G., Wolf, S. E., & Stewart, R. M. (2011) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3182092ff8 · Cited by 71
Abo, A. M., Shannon, M. W., Taylor, G. A., & Bachur, R. G. (2011) · Pediatric Emergency Care · doi:10.1097/pec.0b013e318226c8b0 · Cited by 71
Postnatal spontaneous resolution of congenital cystic adenomatoid malformations
Butterworth, S. A., & Blair, G. K. (2005) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2005.01.051 · Cited by 71
Coronary magnetic resonance angiography and vessel wall imaging in children with Kawasaki disease
Greil, G. F., Seeger, A., Miller, S., Claussen, C. D., Hofbeck, M., Botnar, R. M., & Sieverding, L. (2007) · Pediatric Radiology · doi:10.1007/s00247-007-0498-x · Cited by 71
Semelka, R. C., Armao, D. M., Elías, J., & Picano, E. (2011) · Radiology · doi:10.1148/radiol.11110616 · Cited by 71
Slovis, T. L. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.1.1790039 · Cited by 71
Brink, M., Deunk, J., Dekker, H. M., Kool, D. R., Edwards, M. J., van Vugt, A. B., & Blickman, J. G. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3277 · Cited by 71
PET/CT and SPECT/CT Dosimetry in Children: The Challenge to the Pediatric Imager
Gelfand, M. J., & Lemen, L. C. (2007) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2007.05.002 · Cited by 71
Three-dimensional cone beam computerized tomography in dentistry.
Palomo, J. M., Kau, C. H., Palomo, L., & Hans, M. G. (2006) · PubMed · Cited by 70
The Utility of Clinical and Laboratory Data for Predicting Intraabdominal Injury Among Children
Cotton, B. A., Beckert, B. W., Smith, M. K., & Burd, R. S. (2004) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000082153.38386.20 · Cited by 70
de Jong, M. C., de Graaf, P., Noij, D. P., Göricke, S. L., Maeder, P. P., Galluzzi, P., Brisse, H. J., Moll, A. C., & Castelijns, J. A. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2013.11.021 · Cited by 70
Schonfeld, D., Fitz, B. M., & Nigrovic, L. E. (2013) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2013.06.020 · Cited by 70
Effective Radiation Dose from Radiologic Studies in Pediatric Trauma Patients
Kim, P. K., Zhu, X., Houseknecht, E., Nickolaus, D., Mahboubi, S., & Nance, M. L. (2005) · World Journal of Surgery · doi:10.1007/s00268-005-0106-x · Cited by 70
Single versus Multi–Detector Row CT
Thornton, F. J., Paulson, E. K., Yoshizumi, T. T., Frush, D. P., & Nelson, R. C. (2003) · Academic Radiology · doi:10.1016/s1076-6332(03)80026-0 · Cited by 69
Han, F., Rapacchi, S., Khan, S. N., Ayad, I., Salusky, I. B., Gabriel, S., Plotnik, A. N., Finn, J. P., & Hu, P. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25491 · Cited by 69
CT in children – dose protection and general considerations when planning a CT in a child
Sorantin, E., Weissensteiner, S., Hasenburger, G., & Riccabona, M. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.11.041 · Cited by 69
The imaging of paediatric thoracic trauma
Moore, M. A., Wallace, E. C., & Westra, S. J. (2009) · Pediatric Radiology · doi:10.1007/s00247-008-1093-5 · Cited by 69
Brisse, H. J., & Aubert, B. (2009) · Journal de Radiologie · doi:10.1016/s0221-0363(09)72471-0 · Cited by 69
Optimizing the role of imaging in appendicitis
Doria, A. S. (2009) · Pediatric Radiology · doi:10.1007/s00247-008-1105-5 · Cited by 69
Neuroimaging in the Evaluation of Neonatal Encephalopathy
Barnette, A. R., Horbar, J. D., Soll, R. F., Pfister, R. H., Nelson, K. B., Kenny, M. J., Raju, T. N. K., Bingham, P. M., & Inder, T. E. (2014) · PEDIATRICS · doi:10.1542/peds.2013-4247 · Cited by 69
Koral, K., Blackburn, T., Bailey, A. A., Koral, K., & Anderson, J. A. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3076 · Cited by 69
Iverson, G. L., & Lange, R. T. (2010) · Springer eBooks · doi:10.1007/978-0-387-76978-3_22 · Cited by 74
Reducing Radiation Exposure from Survey CT Scans
O'Daniel, J. C., Stevens, D. M., & CODY, D. D. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.185.2.01850509 · Cited by 68
Chwals, W. J., Robinson, A. V., Sivit, C. J., Alaedeen, D. I., Fitzenrider, E., & Cizmar, L. (2008) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2008.08.061 · Cited by 68
Blomberg, B. A., Moghbel, M. C., Saboury, B., Stanley, C. A., & Alavi, A. A. (2012) · Molecular Imaging and Biology · doi:10.1007/s11307-012-0572-0 · Cited by 70
Imaging of Pediatric Patients With Inflammatory Bowel Disease
Duigenan, S., & Gee, M. S. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.7966 · Cited by 67
Wang, J., Mu, X., Li, Y., Xu, F., Long, W., Jiang, Y., Bian, P., Chen, J., Ouyang, L., Liu, H., et al. (2018) · Small · doi:10.1002/smll.201703736 · Cited by 67
Sola, J. E., Cheung, M. C., Yang, R., Mautner, S. K., Lanuti, E. L., Seaver, C., Neville, H. L., & Schulman, C. I. (2009) · Journal of Surgical Research · doi:10.1016/j.jss.2009.03.058 · Cited by 67
Heyer, C. M., Hansmann, J., Peters, S. A., & Lemburg, S. P. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.06.014 · Cited by 67
Is lung ultrasound superior to CT? The example of a CT occult necrotizing pneumonia
Lichtenstein, D. A., & Peyrouset, O. (2006) · Intensive Care Medicine · doi:10.1007/s00134-005-0004-6 · Cited by 67
Ultrasound in the Diagnosis of Craniosynostosis
Regelsberger, J., Delling, G., Helmke, K., Tsokos, M., Kammler, G., Kränzlein, H., & Westphal, M. (2006) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200607000-00002 · Cited by 67
Bedside renal ultrasound in the evaluation of suspected ureterolithiasis
Moak, J. H., Lyons, M. S., & Lindsell, C. J. (2010) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2010.11.024 · Cited by 67
Huang, B., Li, J., Law, M. W.-M., Zhang, J., Shen, Y., & Khong, P. L. (2010) · British Journal of Radiology · doi:10.1259/bjr/29879495 · Cited by 67
Zhang, H., Liao, M., Chen, J., Zhu, D., & Byanju, S. (2016) · Pediatric Radiology · doi:10.1007/s00247-016-3727-3 · Cited by 72
Nagaraja, S., Anslow, P., & Winter, B. (2012) · Clinical Radiology · doi:10.1016/j.crad.2012.07.005 · Cited by 67
Epidemiology of Thyroid Cancer
Figge, J. J. (2006) · Humana Press eBooks · doi:10.1007/978-1-59259-995-0_2 · Cited by 67
ALARA (as low as reasonably achievable) CT 2011—executive summary
Newman, B., & Callahan, M. J. (2011) · Pediatric Radiology · doi:10.1007/s00247-011-2154-8 · Cited by 67
Neuroimaging findings in pediatric sports-related concussion
Ellis, M. J., Leiter, J., Hall, T., McDonald, P. J., Sawyer, S., Silver, N., Bunge, M. K., & Essig, M. (2015) · Journal of Neurosurgery Pediatrics · doi:10.3171/2015.1.peds14510 · Cited by 66
Managing radiation risk in the evaluation of the pediatric trauma patient
Scaife, E. R., & Rollins, M. D. (2010) · Seminars in Pediatric Surgery · doi:10.1053/j.sempedsurg.2010.06.004 · Cited by 66
Multidetector CT for congenital heart patients: what a paediatric radiologist should know
Paul, J., Rohnean, A., & Sigal-Cinqualbre, A. B. (2010) · Pediatric Radiology · doi:10.1007/s00247-010-1614-x · Cited by 66
Pediatric Cranioplasty Using Particulate Calvarial Bone Graft
Greene, A. K., Mulliken, J. B., Proctor, M. R., & Rogers, G. F. (2008) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0b013e31817d61c1 · Cited by 66
Yue, E. L., Meckler, G. D., Fleischman, R. J., Selden, N. R. W., Bardo, D. M. E., O'Connor, A. K. C., Vu, E. T., Fu, R. F., & Spiro, D. M. (2015) · Journal of Neurosurgery Pediatrics · doi:10.3171/2014.9.peds14207 · Cited by 66
Quantitative Assessment of Diagnostic Radiation Doses in Adult Blunt Trauma Patients
Winslow, J. E., Hinshaw, J. W., Hughes, M. J., Williams, R. C., & Bozeman, W. P. (2008) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2007.12.019 · Cited by 66
Kim, K. P., de González, A. B., Pearce, M. S., Salotti, J. A., Parker, L., McHugh, K., Craft, A. W., & Lee, C. R. (2012) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncr429 · Cited by 66
Age-related effects of X-ray irradiation on mouse hippocampus
Casciati, A., Dobos, K., Antonelli, F., Benedek, A., Kempf, S. J., Bellés, M., Balogh, A., Tanori, M., Heredia, L., Atkinson, M. J., et al. (2016) · Oncotarget · doi:10.18632/oncotarget.8575 · Cited by 66
Use of Low-Value Pediatric Services Among the Commercially Insured
Chua, K., Schwartz, A. L., Volerman, A., Conti, R. M., & Huang, E. S. (2016) · PEDIATRICS · doi:10.1542/peds.2016-1809 · Cited by 66
Computed tomography in children with community-acquired pneumonia
Andronikou, S., Goussard, P., & Sorantin, E. (2017) · Pediatric Radiology · doi:10.1007/s00247-017-3891-0 · Cited by 66
Cost-effectiveness of Competing Strategies for the Treatment of Pediatric Empyema
Cohen, E., Weinstein, M., & Fisman, D. N. (2008) · PEDIATRICS · doi:10.1542/peds.2007-1886 · Cited by 66
Low-dose and Standard Computed Tomography Scans Yield Equivalent Stone Measurements
Sohn, W., Clayman, R. V., Lee, J. Y., Cohen, A. J., & Mucksavage, P. (2013) · Urology · doi:10.1016/j.urology.2012.09.049 · Cited by 65
Solution-grown BiI/BiI3 van der Waals heterostructures for sensitive X-ray detection
Zhuang, R., Cai, S., Mei, Z., Liang, H., Zhao, N., Mu, H., Yu, W., Jiang, Y. L., Yuan, J., Lau, S. P., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-37297-z · Cited by 65
Radiation Safety Knowledge and Perceptions among Residents
Sadigh, G., Khan, R. N., Kassin, M. T., & Applegate, K. E. (2014) · Academic Radiology · doi:10.1016/j.acra.2014.01.016 · Cited by 65
Kharbanda, A. B., Cosme, Y., Liu, K., Spitalnik, S. L., & Dayan, P. S. (2011) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2011.01095.x · Cited by 65
A study to establish international diagnostic reference levels for paediatric computed tomography
Vassileva, J., Rehani, M. M., Kostova-Lefterova, D. Z., AlNaemi, H., AlSuwaidi, J. S., Arandjic, D., Bashier, E., Renha, S. K., El-Nachef, L., Aguilar, J. G., et al. (2015) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncv116 · Cited by 65
Cranial Ultrasound as a First-Line Imaging Examination for Craniosynostosis
Rozovsky, K., Udjus, K., Wilson, N., Barrowman, N. J., Simanovsky, N., & Miller, E. (2016) · Pediatrics · doi:10.1542/peds.2015-2230 · Cited by 64
Ultrasound detection of pneumonia in febrile children with respiratory distress: a prospective study
Guerra, M., Crichiutti, G., Pecile, P., Romanello, C., Busolini, E., Valent, F., & Rosolen, A. (2015) · European Journal of Pediatrics · doi:10.1007/s00431-015-2611-8 · Cited by 64
Ultra-Low Dose Lung CT Perfusion Regularized by a Previous Scan
Yu, H.-Y., Zhao, S.-Y., Hoffman, E. A., & Wang, G. (2009) · Academic Radiology · doi:10.1016/j.acra.2008.09.003 · Cited by 4
Strategies for dose reduction in ordinary radiographic examinations using CR and DR
Willis, C. (2004) · Pediatric Radiology · doi:10.1007/s00247-004-1269-6 · Cited by 64
Patient Radiation Exposure in a Modern, Large-Volume, Pediatric Cardiac Catheterization Laboratory
Glatz, A. C., Patel, A., Zhu, X., Dori, Y., Hanna, B. D., Gillespie, M. J., & Rome, J. J. (2014) · Pediatric Cardiology · doi:10.1007/s00246-014-0869-7 · Cited by 63
Siegel, J. A., Sacks, B., Pennington, C. W., & Welsh, J. S. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.195263 · Cited by 63
Understanding, justifying, and optimizing radiation exposure for CT imaging in nephrourology
Ferrero, A., Takahashi, N., Vrtiska, T. J., Krambeck, A. E., Lieske, J. C., & McCollough, C. H. (2019) · Nature Reviews Urology · doi:10.1038/s41585-019-0148-8 · Cited by 63
Epidemiological studies of CT scans and cancer risk: the state of the science
de González, A. B., Pasqual, E., & Veiga, L. H. S. (2021) · British Journal of Radiology · doi:10.1259/bjr.20210471 · Cited by 64
Wang, L. L., Haberland, C., Thurm, C. W., Bhattacharya, J., & Park, K. T. (2015) · PLoS ONE · doi:10.1371/journal.pone.0132758 · Cited by 63
Image quality and dose management in digital radiography: a new paradigm for optimisation
Busch, H. P., & Faulkner, K. (2005) · Radiation Protection Dosimetry · doi:10.1093/rpd/nci728 · Cited by 63
Renal vein obstruction and orthostatic proteinuria: a review
Mazzoni, M. B. M., Kottanatu, L., Simonetti, G. D., Ragazzi, M., Bianchetti, M. G., Fossali, E. F., & Milani, G. P. (2010) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfq444 · Cited by 63
Lee, C. I., Flaster, H. V., Haims, A. H., Monico, E., & Forman, H. P. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0813 · Cited by 63
Bachur, R. G., Dayan, P. S., Bajaj, L., Macias, C. G., Mittal, M. K., Stevenson, M. D., Dudley, N. C., Sinclair, K. A., Bennett, J. E., Monuteaux, M. C., et al. (2012) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2012.05.034 · Cited by 63
Chung, S., Mikrogianakis, A., Wales, P. W., Dirks, P. B., Shroff, M. M., Singhal, A., Grant, V., Hancock, B. J., Creery, D., Atkinson, J., et al. (2011) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3182108823 · Cited by 63
Koivisto, J., van Eijnatten, M. A. J. M., Kiljunen, T., Shi, X., & Wolff, J. (2017) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncx210 · Cited by 63
Applications of contrast-enhanced ultrasound in the pediatric abdomen
Ntoulia, A., Anupindi, S. A., Darge, K., & Back, S. J. (2017) · Abdominal Radiology · doi:10.1007/s00261-017-1315-0 · Cited by 63
Kralik, S. F., Supakul, N., Wu, I. C., Delso, G., Radhakrishnan, R., Ho, C. Y., & Eley, K. A. (2018) · Neuroradiology · doi:10.1007/s00234-018-2127-9 · Cited by 63
Ngaile, J. E., Uiso, C. B. S., Msaki, P., & Kazema, R. (2008) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncn095 · Cited by 62
Metadata
- Authors
- Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E.
- Affiliations
- Columbia University (US)
- Columbia University Irving Medical Center (US)
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2001-02
- Volume
- 176
- Issue
- 2
- Pages
- 289-296
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2138025351
- Cited by
- 3,222
- References
- 79
- Citations by year
- 2026: 44 · 2025: 92 · 2024: 78 · 2023: 115 · 2022: 116 · 2021: 134 · 2020: 148 · 2019: 137 · 2018: 124 · 2017: 141 · 2016: 190 · 2015: 186 · 2014: 179 · 2013: 176 · 2012: 213
- FWCI
- 60.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Roentgenology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ca077285-03)
- National Cancer Institute (CA77285)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Keywords
- pediatric computed tomography, radiation-induced cancer, age at diagnosis, linear no-threshold model, low-dose radiation risk, abdominal CT, head CT, benefits and risks
- MeSH terms
- Adolescent, Cause of Death, Child, Child, Preschool, Female, Humans, Infant, Infant, Newborn, Male, Neoplasms, Radiation-Induced, Tomography, X-Ray Computed, Risk Assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review