The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Abstract
OBJECTIVE: In light of the rapidly increasing frequency of pediatric CT examinations, the purpose of our study was to assess the lifetime cancer mortality risks attributable to radiation from pediatric CT. MATERIALS AND METHODS: Organ doses as a function of age-at-diagnosis were estimated for common CT examinations, and estimated attributable lifetime cancer mortality risks (per unit dose) for different organ sites were applied. Standard models that assume a linear extrapolation of risks from intermediate to low doses were applied. On the basis of current standard practice, the same exposures (milliampere-seconds) were assumed, independent of age. RESULTS: The larger doses and increased lifetime radiation risks in children produce a sharp increase, relative to adults, in estimated risk from CT. Estimated lifetime cancer mortality risks attributable to the radiation exposure from a CT in a 1-year-old are 0.18% (abdominal) and 0.07% (head)-an order of magnitude higher than for adults-although those figures still represent a small increase in cancer mortality over the natrual background rate. In the United States, of approximately 600,000 abdominal and head CT examinations annually performed in children under the age of 15 years, a rough estimate is that 500 of these individuals might ultimately die from cancer attributable to the CT radiation. CONCLUSION: The best available risk estimates suggest that pediatric CT will result in significantly increased lifetime radiation risk over adult CT, both because of the increased dose per milliampere-second, and the increased lifetime risk per unit dose. Lower milliampere-second settings can be used for children without significant loss of information. Although the risk-benefit balance is still strongly tilted toward benefit, because the frequency of pediatric CT examinations is rapidly increasing, estimates that quantitative lifetime radiation risks for children undergoing CT are not negligible may stimulate more active reduction of CT exposure settings in pediatric patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Brenner et al. concluded already in 2001 that paediatric CT scans significantly increase the lifetime risk of cancer mortality due to the higher radiation sensitivity of children”
From Developments in diagnostic and surgical techniques in children with sagittal suture craniosynostosis: a systematic review spanning the last 30 years (2025) · cites this paper as [66]
Citations
Cites
Sources and effects of ionizing radiation
United Nations Scientific Committee on the Effects of Atomic Radiation (2018) · Report of the United Nations Scientific Committee on the Effects of Atomic Radiation · doi:10.18356/f48d655d-en · Cited by 3,981
International Commission on Radiological Protection
(1969) · Radiology · doi:10.1148/93.6.1298 · Cited by 2,148
Thyroid Cancer after Exposure to External Radiation: A Pooled Analysis of Seven Studies
Ron, E., Lubin, J. H., Shore, R. E., Mabuchi, K., Modan, B., Pottern, L. M., Schneider, A. B., Tucker, M. A., & Boice, J. D. (2012) · Radiation Research · doi:10.1667/rrav05.1 · Cited by 1,124
Thyroid Cancer after Exposure to External Radiation: A Pooled Analysis of Seven Studies
Ron, E., Lubin, J. H., Shore, R. E., Mabuchi, K., Modan, B., Pottern, L. M., Schneider, A. B., Tucker, M. A., & Boice, J. D. (1995) · Radiation Research · doi:10.2307/3579003 · Cited by 1,107 · cited 1×
“The risk estimates given here are for lifetime cancer mortality; estimated cancer risks from pediatric CT examinations would, by definition, be larger, particularly for CT examinations of the head, because of the larger contribution of radiation-induced thyroid cancer [34].”
BackgroundStudies of the Mortality of Atomic Bomb Survivors. Report 12, Part I. Cancer: 1950-1990
Pierce, D. A., Shimizu, Y., Preston, D. L., Væth, M., & Mabuchi, K. (1996) · Radiation Research · doi:10.2307/3579391 · Cited by 938
Risk of childhood cancer from fetal irradiation.
Doll, R., & Wakeford, R. (1997) · British Journal of Radiology · doi:10.1259/bjr.70.830.9135438 · Cited by 683
Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative
Brenner, D. J. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0671-1 · Cited by 555
Self-citationHealth effects of exposure to low levels of ionizing radiation
Schonken, P. (1991) · Health Policy · doi:10.1016/0168-8510(91)90028-v · Cited by 530
National Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 381
Research works printed but not linked: 2
- Chamberlain C, Huda W, Rosenbaum A, Garissi W. Adult and pediatric radiation doses in head CT examinations. (abstr) Med Phys 1998; 25:A216
- National Council on Radiation Protection and Measurements. Evaluation of the linear non-threshold dose-response model. Bethesda, MD: NCRP Publications, 2000 (in press)
Cited by
Sorted by citations
Items 801–900 of 1,005
Engel, M., Castrillon‐Oberndorfer, G., Hoffmann, J., & Freudlsperger, C. (2012) · Journal of Plastic Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2012.03.038 · Cited by 36
Headaches in the Pediatric Population
Brna, P. M., & Dooley, J. M. (2006) · Seminars in Pediatric Neurology · doi:10.1016/j.spen.2006.09.003 · Cited by 36
Effect of reduction in tube current on reader confidence in paediatric computed tomography
Shah, R., Gupta, A., Rehani, M. M., Pandey, A. K., & Mukhopadhyay, S. (2005) · Clinical Radiology · doi:10.1016/j.crad.2004.08.011 · Cited by 36
Radiation, Thoracic Imaging, and Children: Radiation Safety
Frush, D. P. (2011) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2011.06.003 · Cited by 36
Radiation Dose and Excess Risk of Cancer in Children Undergoing Neuroangiography
Raelson, C. A., Kanal, K. M., Vavilala, M. S., Rivara, F. P., Kim, L. J., Stewart, B. K., & Cohen, W. A. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2352 · Cited by 36
Pediatric Urolithiasis: Clinical Predictors in the Emergency Department
Persaud, A. C., Stevenson, M. D., McMahon, D. R., & Christopher, N. C. (2009) · PEDIATRICS · doi:10.1542/peds.2008-2427 · Cited by 36
Radiation Dose Features and Solid Cancer Induction in Pediatric Computed Tomography
Pauwels, E. K. J., & Bourguignon, M. (2012) · Medical Principles and Practice · doi:10.1159/000337404 · Cited by 36
Imaging of the acetabulum in the era of multidetector computed tomography
Geijer, M., & El-Khoury, G. Y. (2007) · Emergency Radiology · doi:10.1007/s10140-007-0638-5 · Cited by 36
Saltzherr, T. P., Jin, P. H. P. F. K., Beenen, L. F. M., Vandertop, W. P., & Goslings, J. C. (2009) · Injury · doi:10.1016/j.injury.2009.01.015 · Cited by 36
Effect of Tube Voltage on CT Noise Levels in Different Phantom Sizes
Karmazyn, B. W., Liang, Y., Klahr, P., & Jennings, S. G. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9828 · Cited by 36
Implications of Ionizing Radiation in the Pediatric Urology Patient
Stratton, K. L., POPE, J. C. I., Adams, M. C., Brock, J. W. I., & Thomas, J. C. (2010) · The Journal of Urology · doi:10.1016/j.juro.2010.02.2384 · Cited by 36
Milliner, D. S. (2009) · Springer eBooks · doi:10.1007/978-3-540-76341-3_58 · Cited by 36
Weathers, W. M., Khechoyan, D., Wolfswinkel, E. M., Mohan, K., Nagy, A., Bollo, R. J., Buchanan, E. P., & Hollier, L. H. (2014) · Craniomaxillofacial Trauma & Reconstruction · doi:10.1055/s-0033-1356758 · Cited by 35
Johnston, J. H., Podberesky, D. J., Yoshizumi, T. T., Angel, E., Toncheva, G. I., Larson, D. B., Egelhoff, J. C., Anderson-Evans, C., Nguyen, G. B., Barelli, A., et al. (2013) · Pediatric Radiology · doi:10.1007/s00247-013-2690-5 · Cited by 35
Zhang, Y., Yan, Y., Nath, R., Bao, S., & Deng, J. (2012) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2011.10.072 · Cited by 35
Improving ultrasound for appendicitis through standardized reporting of secondary signs
Partain, K. N., Patel, A. U., Travers, C. D., Short, H. L., Braithwaite, K. A., Loewen, J., Heiss, K. F., & Raval, M. V. (2016) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2016.11.045 · Cited by 35
Beebe, M. J., Wylie, J. D., Bodine, B. G., Kapron, A. L., Maak, T. G., Mei-Dan, O., & Aoki, S. K. (2017) · Journal of Pediatric Orthopaedics · doi:10.1097/bpo.0000000000000959 · Cited by 35
Multimodality neuromonitoring in severe pediatric traumatic brain injury
Young, A. M. H., Guilfoyle, M. R., Donnelly, J., Smielewski, P. S., Agarwal, S., Czosnyka, M., & Hutchinson, P. J. (2017) · Pediatric Research · doi:10.1038/pr.2017.215 · Cited by 35
Ultra-low dose chest computed tomography: Effect of iterative reconstruction levels on image quality
Afadzi, M., Lysvik, E. K., Andersen, H. K., & Martinsen, A. C. T. (2019) · European Journal of Radiology · doi:10.1016/j.ejrad.2019.02.021 · Cited by 35
Bertsimas, D., Dunn, J., Steele, D. W., Trikalinos, T. A., & Wang, Y. (2019) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/jamapediatrics.2019.1068 · Cited by 36
Alexandridis, G., Verschuuren, E. W., Rosendaal, A. V., & Kanhai, D. A. (2020) · Emergency Medicine Journal · doi:10.1136/emermed-2020-209887 · Cited by 39
Should I irradiate with computed tomography or sedate for magnetic resonance imaging?
Callahan, M. J., & Cravero, J. P. (2021) · Pediatric Radiology · doi:10.1007/s00247-021-04984-2 · Cited by 35
Validation of a Clinical Score to Predict Skull Fracture in Head-Injured Infants
Bin, S. S., Schutzman, S. A., & Greenes, D. S. (2010) · Pediatric Emergency Care · doi:10.1097/pec.0b013e3181ef0440 · Cited by 35
Pediatric Ophthalmic Computed Tomographic Scanning and Associated Cancer Risk
Mills, D. M., Tsai, S. D., Meyer, D. R., & Belden, C. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.08.024 · Cited by 35
Benefits of ultrasound vs. computed tomography in the diagnosis of pediatric lateral neck abscesses
Collins, B., Stoner, J. A., & Digoy, G. P. (2013) · International Journal of Pediatric Otorhinolaryngology · doi:10.1016/j.ijporl.2013.11.034 · Cited by 35
Honnef, D., Wildberger, J. E., Das, M., Hohl, C., Mahnken, A. H., Barker, M., Günther, R. W., & Staatz, G. (2006) · European Radiology · doi:10.1007/s00330-006-0230-5 · Cited by 35
Nationwide Emergency Department Imaging Practices for Pediatric Urolithiasis: Room for Improvement
Johnson, E. K., Graham, D. A., Chow, J. S., & Nelson, C. P. (2014) · The Journal of Urology · doi:10.1016/j.juro.2014.01.028 · Cited by 35
Tse, D. T., Abdulhafez, M., Orozco, M. A., Tse, J. D., Azab, A. O., & Pinchuk, L. (2010) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2010.09.009 · Cited by 35
[An outlook on X-ray CT research and development].
Wang, G., Yu, H., & Man, B. D. (2008) · PubMed · Cited by 35
Staton, R. J., Lee, C., Lee, C., Williams, M. D., Hintenlang, D. E., Arreola, M. M., Williams, J. L., & Bolch, W. E. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/20/005 · Cited by 35
Eliminating Unenhanced CT When Evaluating Abdominal Neoplasms in Children
Silva, E. J. D. C. E., & da Silva, G. A. P. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2154 · Cited by 35
Boiselle, P. M., D’Ippolito, G., Copeland, J. F., Kang, H., Ahmed, M., Weeks, D., Halpern, E. F., & Goldberg, S. N. (2003) · Radiology · doi:10.1148/radiol.2281020730 · Cited by 35
Dose Reduction in CT: How Low Can We Go?
Rogers, L. F. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.2.1790299 · Cited by 35
The Role of the Medical Physicist in Managing Radiation Dose and Communicating Risk in CT
McCollough, C. H. (2016) · American Journal of Roentgenology · doi:10.2214/ajr.15.15651 · Cited by 34
Peterson, H. O., Lester, R. G., & Levitt, S. H. (1972) · American Journal of Roentgenology · doi:10.2214/ajr.115.4.849 · Cited by 34
Hampers, L. C., Thompson, D. A., Bajaj, L., Tseng, B. S., & Rudolph, J. R. (2006) · Pediatric Emergency Care · doi:10.1097/01.pec.0000226870.49427.a5 · Cited by 34
Ferrari, M. E., Marco, P. D., Origgi, D., & Pedroli, G. (2014) · Clinical and Translational Imaging · doi:10.1007/s40336-014-0093-8 · Cited by 34
Li, B., Behrman, R. H., & Norbash, A. (2012) · Medical Physics · doi:10.1118/1.4718569 · Cited by 34
de Jong, M. C., de Graaf, P., Brisse, H. J., Galluzzi, P., Göricke, S. L., Moll, A. C., Munier, F. L., Popovic, M. B., Moulin, A., Binaghi, S., et al. (2015) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2015.01.002 · Cited by 34
Hazards of Ionizing Radiation and its Impact on Spine Surgery
Hadelsberg, U. P., & Harel, R. (2016) · World Neurosurgery · doi:10.1016/j.wneu.2016.05.025 · Cited by 34
Abdolrazaghnejad, A., Banaie, M., & Safdari, M. (2018) · PubMed Central · doi:10.22114/ajem.v0i0.40 · Cited by 35
Zirpoli, S., Munari, A., Primolevo, A., Scarabello, M., Costanzo, S., Farolfi, A., Lista, G., Zoia, E., Zuccotti, G., Riccipetitoni, G., et al. (2019) · European Radiology · doi:10.1007/s00330-019-06042-w · Cited by 34
Jayanth, A., Benabbas, R., Chao, J. H., & Sinert, R. H. (2020) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2020.09.024 · Cited by 33
Radiation-Induced Optic Neuropathy: Literature Review
Ataídes, F. G., Silva, S. F. B. R., & Baldin, J. J. C. M. D. C. (2020) · Neuro-Ophthalmology · doi:10.1080/01658107.2020.1817946 · Cited by 34
Dietrich, C. F., Augustinienė, R., Batko, T., Cantisani, V., Čekuolis, A., Deganello, A., Dong, Y., Franke, D., Harkanyi, Z., Humphries, P. D., et al. (2021) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-1345-3626 · Cited by 34
Pediatric Spinal Cord Injury: A Review
Cunha, N., Malvea, A., Sadat, S., Fehlings, M. G., & Ibrahim, G. M. (2023) · Children · doi:10.3390/children10091456 · Cited by 35
McNiven, C., Switzer, N. J., Wood, M. L., Persad, R., Hancock, M., Forgie, S. E. D., & Dicken, B. J. (2015) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2015.08.003 · Cited by 34
Estimation of patient organ doses from CT examinations in Tanzania
Ngaile, J. E., & Msaki, P. (2006) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v7i3.2200 · Cited by 34
Responsible and Prudent Imaging in the Diagnosis and Management of Facial Fractures
Gelesko, S., Markiewicz, M. R., & Bell, R. B. (2013) · Oral and Maxillofacial Surgery Clinics of North America · doi:10.1016/j.coms.2013.07.001 · Cited by 34
Computing effective doses to pediatric patients undergoing body CT examinations
Huda, W., & Ogden, K. M. (2008) · Pediatric Radiology · doi:10.1007/s00247-007-0732-6 · Cited by 34
Dauer, L. T., Casciotta, K. A., Erdi, Y. E., & Rothenberg, L. N. (2007) · BMC Medical Imaging · doi:10.1186/1471-2342-7-5 · Cited by 34
Fitzwater, K. L., Marcellin‐Little, D. J., Harrysson, O. L. A., Osborne, J. A., & Poindexter, E. C. (2011) · American Journal of Veterinary Research · doi:10.2460/ajvr.72.9.1178 · Cited by 34
Gao, L., Rogers, G. F., Clune, J. E., Proctor, M. R., Meara, J. G., Mulliken, J. B., & Greene, A. K. (2010) · Journal of Craniofacial Surgery · doi:10.1097/scs.0b013e3181cf5f8b · Cited by 34
Mackie, A. S., Gauvreau, K., Perry, S. B., del Nido, P. J., & Geva, T. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02960-1 · Cited by 34
Endovascular interventional MRI
Henk, C. B., Higgins, C. B., & Saeed, M. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20411 · Cited by 34
Patient doses in multi-slice CT and the importance of optimisation
Heggie, J. C. P. (2005) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/bf03178698 · Cited by 34
Ward, M. J., Bonomo, J., Adeoye, O. M., Raja, A. S., & Pines, J. M. (2012) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2012.01455.x · Cited by 33
Krimmel, M., Will, B. E., Wolff, M., Kluba, S., Haas‐Lude, K., Schaefer, J. F., Schuhmann, M. U., & Reinert, S. (2012) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2012.02.022 · Cited by 33
Imaging and Laboratory Testing in Acute Abdominal Pain
Panebianco, N. L., Jahnes, K., & Mills, A. M. (2011) · Emergency Medicine Clinics of North America · doi:10.1016/j.emc.2011.01.010 · Cited by 33
Management of pediatric head and neck rhabdomyosarcoma: A case-series of 36 patients
Radzikowska, J., Kukwa, W., Kukwa, A., Czarnecka, A. M., Kawecki, M., Lian, F., Szczylik, C. A., & Krzeski, A. (2016) · Oncology Letters · doi:10.3892/ol.2016.5072 · Cited by 33
Radiation exposure in diagnostic imaging: wisdom and prudence, but still a lot to understand
Tomà, P., Cannatà, V., Genovese, E., Magistrelli, A., & Granata, C. (2016) · La radiologia medica · doi:10.1007/s11547-016-0709-3 · Cited by 33
Evolution of lymphoma staging and response evaluation: current limitations and future directions
Cunningham, J., Iyengar, S., & Sharma, B. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.78 · Cited by 33
Raza, M., Murphy, D., & Gelfer, Y. (2021) · EFORT Open Reviews · doi:10.1302/2058-5241.6.200092 · Cited by 33
Computed tomography phantom for radiochromic film dosimetry
Gotanda, R., Katsuda, T., Gotanda, T., Eguchi, M., Takewa, S., Tabuchi, A., & Yatake, H. (2007) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/bf03178426 · Cited by 33
Long term respiratory outcomes of congenital thoracic malformations
Davenport, M., & Eber, E. (2012) · Seminars in Fetal and Neonatal Medicine · doi:10.1016/j.siny.2012.01.011 · Cited by 33
Reference ranges for neuroprotein S-100B: from infants to adolescents
Castellani, C., Stojaković, T., Cichocki, M., Scharnagl, H., Erwa, W., Gutmann, A., & Weinberg, A. (2008) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.262 · Cited by 33
Tahvonen, P. R., Oikarinen, H., Pääkkö, E. L., Karttunen, A., Sequeiros, R. T. B., & Tervonen, O. A. (2013) · British Journal of Radiology · doi:10.1259/bjr.20130337 · Cited by 33
Nanotechnology in the Treatment and Detection of Intraocular Cancers
Nair, A., Thevenot, P., Hu, W., & Tang, L. (2008) · Journal of Biomedical Nanotechnology · doi:10.1166/jbn.2008.004 · Cited by 33
Circumcision for preventing urinary tract infections in boys: North American view
Schoen, E. J. (2005) · Archives of Disease in Childhood · doi:10.1136/adc.2004.066761 · Cited by 33
Dianati, M., Zaheri, A., Talari, H. R., Deris, F., & Rezaei, S. (2014) · Nursing and Midwifery Studies · doi:10.17795/nmsjournal23354 · Cited by 33
Low, R. N. (2016) · Europe PMC (PubMed Central) · doi:10.3978/j.issn.2078-6891.2015.115 · Cited by 33
Image quality & dosimetric property of an investigational Imaging Beam Line MV‐CBCT
Beltran, C. J., Lukose, R. C., Gangadharan, B., Bani‐Hashemi, A. R., & Faddegon, B. (2009) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v10i3.3023 · Cited by 33
Partain, K. N., Patel, A. M., Travers, C. D., McCracken, C., Loewen, J., Braithwaite, K. A., Heiss, K. F., & Raval, M. V. (2016) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2016.03.005 · Cited by 33
Bodelle, B., Fischbach, C., Booz, C., Yel, İ., Frellesen, C., Beeres, M., Vogl, T. J., & Scholtz, J. (2017) · European Journal of Radiology · doi:10.1016/j.ejrad.2017.01.027 · Cited by 33
Computed radiography: a higher dose?
Willis, C. E. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0804-6 · Cited by 33
CT Radiation Dose: Trending in the Right Direction
Amis, E. S. (2011) · Radiology · doi:10.1148/radiol.11111319 · Cited by 33
On prognostic estimates of radiation risk in medicine and radiation protection
Ulanowski, A., Kaiser, J. C., Schneider, U., & Walsh, L. (2019) · Radiation and Environmental Biophysics · doi:10.1007/s00411-019-00794-1 · Cited by 31
Mihalik, J. E., Smith, R. S., Toevs, C. C., Putnam, A. T., & Foster, J. E. (2012) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e31825a74b5 · Cited by 32
Imaging of congenital coronary artery anomalies
Walsh, R. F., Nielsen, J. C., Ko, H. H., Sanz, J., Srivastava, S., Parness, I. A., & Lytrivi, I. D. (2011) · Pediatric Radiology · doi:10.1007/s00247-011-2256-3 · Cited by 32
Carbone, I., Cannata, D., Algeri, E., Galea, N., Napoli, A., Zorzi, A. D., Bosco, G., D’Agostino, R., Menezes, L., Catalano, C., et al. (2011) · Pediatric Radiology · doi:10.1007/s00247-011-2141-0 · Cited by 32
Dellie, S. T., Admassie, D., & Ewnetu, Y. (2014) · Advances in Radiology · doi:10.1155/2014/426909 · Cited by 32
Pediatric Head Injury and Concussion
Wing, R., & James, C. A. (2013) · Emergency Medicine Clinics of North America · doi:10.1016/j.emc.2013.05.007 · Cited by 32
Use of a mild traumatic brain injury guideline to reduce inpatient hospital imaging and charges
Goldberg, J., McClaine, R. J., Cook, B., Garcia, V. F., Brown, R. L., Crone, K. R., & Falcone, R. A. (2011) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2011.02.052 · Cited by 32
Gökçe, S. D., Gökçe, E., & Çoşkun, M. (2012) · Korean Journal of Radiology · doi:10.3348/kjr.2012.13.2.202 · Cited by 32
Cervical spine computed tomography utilization in pediatric trauma patients
Adelgais, K., Browne, L. R., Holsti, M., Metzger, R. R., Murphy, S. C., & Dudley, N. C. (2013) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2013.10.006 · Cited by 32
Radiological Surveillance Screening in Asymptomatic Succinate Dehydrogenase Mutation Carriers
Tufton, N., Sahdev, A., & Akker, S. A. (2017) · Journal of the Endocrine Society · doi:10.1210/js.2017-00230 · Cited by 32
Knowledge and practice of computed tomography exposure parameters amongst radiographers in Jordan
Rawashdeh, M. A., McEntee, M. F., Zaitoun, M., Abdelrahman, M. A., Brennan, P., Alewaidat, H., Lewis, S. J., & Saade, C. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.09.020 · Cited by 32
Radiation doses in diagnostic imaging for suspected physical abuse
Rao, R., Browne, D., Lunt, B., Perry, D. H., Reed, P., & Kelly, P. J. (2019) · Archives of Disease in Childhood · doi:10.1136/archdischild-2018-316286 · Cited by 32
Tahmasebzadeh, A., Paydar, R., Soltani‐Kermanshahi, M., Maziar, A., & Reiazi, R. (2021) · International Journal of Radiation Biology · doi:10.1080/09553002.2021.1931527 · Cited by 32
Analysis of Radiation Dose to Pediatric Patients During Computed Tomography Examinations
Kharbanda, A. B., Krause, E. A., Lu, Y., & Blumberg, K. (2015) · Academic Emergency Medicine · doi:10.1111/acem.12689 · Cited by 32
Update on Imaging of the Lacrimal Drainage System
Lefebvre, D. R., & Freitag, S. K. (2012) · Seminars in Ophthalmology · doi:10.3109/08820538.2012.711413 · Cited by 32
Postovsky, S., Barzilai, M., Meller, I., Kollander, Y., Futerman, B., & Arush, M. W. B. (2008) · Journal of Pediatric Hematology/Oncology · doi:10.1097/mph.0b013e31815d88fa · Cited by 32
Predictors of abnormal chest CT after blunt trauma: a critical appraisal of the literature
Brink, M., Kool, D. R., Dekker, H. M., Deunk, J., Jager, G. J., van Kuijk, C., Edwards, M. J., & Blickman, J. G. (2008) · Clinical Radiology · doi:10.1016/j.crad.2008.09.004 · Cited by 32
Ferrari, A., Salvo, G. L. D., Oberlin, O., Casanova, M., Paoli, A. D., Rey, A., Minard‐Colin, V., Orbach, D. H., Carli, M., Brennan, B. M. D., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2012.01.013 · Cited by 32
Genes and environment: effects on the development of second malignancies in retinoblastoma survivors
Schefler, A. C., Kleinerman, R. A., & Abramson, D. H. (2008) · Expert Review of Ophthalmology · doi:10.1586/17469899.3.1.51 · Cited by 32
Patient dose estimation for multi-detector-row CT examinations
Nishizawa, K., Mori, S., Ohno, M., Yanagawa, N., Yoshida, T., Akahane, K., Iwai, K., & Wada, S.-I. (2007) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncm244 · Cited by 32
CT versus MR in neonatal brain imaging at term
Robertson, R. L., Robson, C. D., Zurakowski, D., Antiles, S., Strauss, K. J., & Mulkern, R. V. (2003) · Pediatric Radiology · doi:10.1007/s00247-003-0933-6 · Cited by 32
International Guidelines for Pediatric Radiopharmaceutical Administered Activities
Treves, S. T., Laßmann, M., & for the EANM/SNMMI Pediatric Dosage Harmonization Working Group (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.139980 · Cited by 32
Dose Estimation for the European Epidemiological Study on Pediatric Computed Tomography (EPI-CT)
Thierry-Chef, I., Ferro, G., Le Cornet, L., Dabin, J., Istad, T. S., Jahnen, A., Lee, C., Maccia, C., Malchair, F., Olerud, H. M., et al. (2021) · Radiation Research · doi:10.1667/rade-20-00231.1 · Cited by 31
Potential benefits of photon counting detector computed tomography in pediatric imaging
Horst, K. K., Yu, L., McCollough, C. H., Esquivel, A., Thorne, J. E., Rajiah, P. S., Baffour, F. I., Hull, N. C., Weber, N. M., Thacker, P. G., et al. (2023) · British Journal of Radiology · doi:10.1259/bjr.20230189 · Cited by 31
Metadata
- Authors
- Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E.
- Affiliations
- Columbia University (US)
- Columbia University Irving Medical Center (US)
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2001-02
- Volume
- 176
- Issue
- 2
- Pages
- 289-296
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2138025351
- Cited by
- 3,222
- References
- 79
- Citations by year
- 2026: 44 · 2025: 92 · 2024: 78 · 2023: 115 · 2022: 116 · 2021: 134 · 2020: 148 · 2019: 137 · 2018: 124 · 2017: 141 · 2016: 190 · 2015: 186 · 2014: 179 · 2013: 176 · 2012: 213
- FWCI
- 60.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Roentgenology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ca077285-03)
- National Cancer Institute (CA77285)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Keywords
- pediatric computed tomography, radiation-induced cancer, age at diagnosis, linear no-threshold model, low-dose radiation risk, abdominal CT, head CT, benefits and risks
- MeSH terms
- Adolescent, Cause of Death, Child, Child, Preschool, Female, Humans, Infant, Infant, Newborn, Male, Neoplasms, Radiation-Induced, Tomography, X-Ray Computed, Risk Assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review