The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Abstract
OBJECTIVE: In light of the rapidly increasing frequency of pediatric CT examinations, the purpose of our study was to assess the lifetime cancer mortality risks attributable to radiation from pediatric CT. MATERIALS AND METHODS: Organ doses as a function of age-at-diagnosis were estimated for common CT examinations, and estimated attributable lifetime cancer mortality risks (per unit dose) for different organ sites were applied. Standard models that assume a linear extrapolation of risks from intermediate to low doses were applied. On the basis of current standard practice, the same exposures (milliampere-seconds) were assumed, independent of age. RESULTS: The larger doses and increased lifetime radiation risks in children produce a sharp increase, relative to adults, in estimated risk from CT. Estimated lifetime cancer mortality risks attributable to the radiation exposure from a CT in a 1-year-old are 0.18% (abdominal) and 0.07% (head)-an order of magnitude higher than for adults-although those figures still represent a small increase in cancer mortality over the natrual background rate. In the United States, of approximately 600,000 abdominal and head CT examinations annually performed in children under the age of 15 years, a rough estimate is that 500 of these individuals might ultimately die from cancer attributable to the CT radiation. CONCLUSION: The best available risk estimates suggest that pediatric CT will result in significantly increased lifetime radiation risk over adult CT, both because of the increased dose per milliampere-second, and the increased lifetime risk per unit dose. Lower milliampere-second settings can be used for children without significant loss of information. Although the risk-benefit balance is still strongly tilted toward benefit, because the frequency of pediatric CT examinations is rapidly increasing, estimates that quantitative lifetime radiation risks for children undergoing CT are not negligible may stimulate more active reduction of CT exposure settings in pediatric patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Brenner et al. concluded already in 2001 that paediatric CT scans significantly increase the lifetime risk of cancer mortality due to the higher radiation sensitivity of children”
From Developments in diagnostic and surgical techniques in children with sagittal suture craniosynostosis: a systematic review spanning the last 30 years (2025) · cites this paper as [66]
Citations
Cites
Sources and effects of ionizing radiation
United Nations Scientific Committee on the Effects of Atomic Radiation (2018) · Report of the United Nations Scientific Committee on the Effects of Atomic Radiation · doi:10.18356/f48d655d-en · Cited by 3,981
International Commission on Radiological Protection
(1969) · Radiology · doi:10.1148/93.6.1298 · Cited by 2,148
Thyroid Cancer after Exposure to External Radiation: A Pooled Analysis of Seven Studies
Ron, E., Lubin, J. H., Shore, R. E., Mabuchi, K., Modan, B., Pottern, L. M., Schneider, A. B., Tucker, M. A., & Boice, J. D. (2012) · Radiation Research · doi:10.1667/rrav05.1 · Cited by 1,124
Thyroid Cancer after Exposure to External Radiation: A Pooled Analysis of Seven Studies
Ron, E., Lubin, J. H., Shore, R. E., Mabuchi, K., Modan, B., Pottern, L. M., Schneider, A. B., Tucker, M. A., & Boice, J. D. (1995) · Radiation Research · doi:10.2307/3579003 · Cited by 1,107 · cited 1×
“The risk estimates given here are for lifetime cancer mortality; estimated cancer risks from pediatric CT examinations would, by definition, be larger, particularly for CT examinations of the head, because of the larger contribution of radiation-induced thyroid cancer [34].”
BackgroundStudies of the Mortality of Atomic Bomb Survivors. Report 12, Part I. Cancer: 1950-1990
Pierce, D. A., Shimizu, Y., Preston, D. L., Væth, M., & Mabuchi, K. (1996) · Radiation Research · doi:10.2307/3579391 · Cited by 938
Risk of childhood cancer from fetal irradiation.
Doll, R., & Wakeford, R. (1997) · British Journal of Radiology · doi:10.1259/bjr.70.830.9135438 · Cited by 683
Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative
Brenner, D. J. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0671-1 · Cited by 555
Self-citationHealth effects of exposure to low levels of ionizing radiation
Schonken, P. (1991) · Health Policy · doi:10.1016/0168-8510(91)90028-v · Cited by 530
National Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 381
Research works printed but not linked: 2
- Chamberlain C, Huda W, Rosenbaum A, Garissi W. Adult and pediatric radiation doses in head CT examinations. (abstr) Med Phys 1998; 25:A216
- National Council on Radiation Protection and Measurements. Evaluation of the linear non-threshold dose-response model. Bethesda, MD: NCRP Publications, 2000 (in press)
Cited by
Sorted by citations
Items 101–200 of 1,005
Clinical Practice Guideline: Hoarseness (Dysphonia) (Update)
Stachler, R. J., Francis, D. O., Schwartz, S. R., Damask, C. C., Digoy, G. P., Krouse, H. J., McCoy, S. J., Ouellette, D. R., Patel, R. R., Reavis, C. (. W., et al. (2018) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599817751030 · Cited by 368
Radiation Dose Associated with Unenhanced CT for Suspected Renal Colic: Impact of Repetitive Studies
Katz, S. I., Saluja, S., Brink, J. A., & Forman, H. P. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.04.1838 · Cited by 201
Technical approaches to the optimisation of CT
Kalender, W. A., Buchenau, S., Deak, P. D., Kellermeier, M., Langner, O., van Straten, M., Vollmar, S. V., & Wilharm, S. (2008) · Physica Medica · doi:10.1016/j.ejmp.2008.01.012 · Cited by 201
Smith‐Bindman, R., Lipson, J. A., & Marcus, R. (2010) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2010.01.042 · Cited by 199
Peloquin, J. M., Pardi, D. S., Sandborn, W. J., Fletcher, J. G., McCollough, C. H., Schueler, B. A., Kofler, J. M., Enders, F., Achenbach, S. J., & Loftus, E. V. (2008) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2008.01920.x · Cited by 198
Prospective Validation of Computed Tomographic Screening of the Thoracolumbar Spine in Trauma
Hauser, C. J., Visvikis, G. A., Hinrichs, C. R., Eber, C. D., Cho, K., Lavery, R. F., & Livingston, D. H. (2003) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000076622.19246.cf · Cited by 197
Assessment of radiation dose awareness among pediatricians
Thomas, K. E., Parnell-Parmley, J. E., Haidar, S., Moineddin, R., Charkot, E., BenDavid, G., & Krajewski, C. (2006) · Pediatric Radiology · doi:10.1007/s00247-006-0170-x · Cited by 196
Peter, S. D. S., Aguayo, P., Fraser, J. D., Keckler, S. J., Sharp, S. W., Leys, C. M., Murphy, J. P., Snyder, C. L., Sharp, R. J., Andrews, W. S., et al. (2009) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2009.10.039 · Cited by 193
Prehospital Use of Cervical Collars in Trauma Patients: A Critical Review
Sundstrøm, T., Asbjørnsen, H., Habiba, S., Sunde, G. A., & Wester, K. G. (2013) · Journal of Neurotrauma · doi:10.1089/neu.2013.3094 · Cited by 193
Greeß, H., Nömayr, A., Wolf, H., Baum, U., Lell, M., Böwing, B., Kalender, W. A., & Bautz, W. A. (2002) · European Radiology · doi:10.1007/s00330-001-1255-4 · Cited by 192
Influence of patient age on normalized effective doses calculated for CT examinations
Khursheed, A., Hillier, M. C., Shrimpton, P. C., & Wall, B. F. (2002) · British Journal of Radiology · doi:10.1259/bjr.75.898.750819 · Cited by 191
Performance of abdominal ultrasonography in pediatric blunt trauma patients: a meta-analysis
Holmes, J. F., Gladman, A., & Chang, C. H. (2007) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2007.04.023 · Cited by 190
Krishnamoorthi, R., Ramarajan, N., Wang, N. E., Newman, B., Rubesova, E., Mueller, C. M., & Barth, R. A. (2011) · Radiology · doi:10.1148/radiol.10100984 · Cited by 189
A review of patient dose and optimisation methods in adult and paediatric CT scanning
Dougeni, E., Faulkner, K., & Panayiotakis, G. (2011) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.05.025 · Cited by 185
A survey of awareness of radiation dose among health professionals in Northern Ireland
Soye, J. A., & Paterson, A. (2008) · British Journal of Radiology · doi:10.1259/bjr/94101717 · Cited by 185
Meyer, J. S., Nadel, H. R., Marina, N., Womer, R. B., Brown, K. L. B., Eary, J. F., Gorlick, R., Grier, H. E., Randall, R. L., Lawlor, E. R., et al. (2008) · Pediatric Blood & Cancer · doi:10.1002/pbc.21596 · Cited by 180
Krille, L., Dreger, S., Schindel, R., Albrecht, T., Asmussen, M., Barkhausen, J., Berthold, J. D., Chavan, A., Claussen, C., Forsting, M., et al. (2015) · Radiation and Environmental Biophysics · doi:10.1007/s00411-014-0580-3 · Cited by 184
Fricke, B. L., Donnelly, L. F., Frush, D. P., Yoshizumi, T. T., Varchena, V., Poe, S. A., & Lucaya, J. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.2.1800407 · Cited by 184
Slovis, T. L. (2003) · PEDIATRICS · doi:10.1542/peds.112.4.971 · Cited by 184
Pediatric Major Trauma: An Approach to Evaluation and Management
Avarello, J. T., & Cantor, R. M. (2007) · Emergency Medicine Clinics of North America · doi:10.1016/j.emc.2007.06.013 · Cited by 182
Wainwright, C. E., Vidmar, S., Armstrong, D., Byrnes, C. A., Carlin, J. B., Cheney, J. L., Cooper, P., Grimwood, K., Moodie, M., ROBERTSON, C. F., et al. (2011) · JAMA · doi:10.1001/jama.2011.954 · Cited by 180
Hedequist, D., & Emans, J. B. (2007) · Journal of Pediatric Orthopaedics · doi:10.1097/bpo.0b013e31802b4993 · Cited by 180
The ALARA Concept in Pediatric CT: Myth or Reality?
Slovis, T. L. (2002) · Radiology · doi:10.1148/radiol.2231012100 · Cited by 180
Review of radiation risks from computed tomography: essentials for the pediatric surgeon
Rice, H. E., Frush, D. P., Farmer, D. L., & Waldhausen, J. H. T. (2007) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2006.12.009 · Cited by 179
A Clinical Decision Rule to Identify Children at Low Risk for Appendicitis
Kharbanda, A. B., Taylor, G. A., Fishman, S. J., & Bachur, R. G. (2005) · PEDIATRICS · doi:10.1542/peds.2005-0094 · Cited by 179
Song, Y., Li, L., Hao, M., Bi, W., Wang, A., Kang, Y., Li, H., Li, X., Fang, Y., Yang, D., et al. (2021) · Advanced Materials · doi:10.1002/adma.202103078 · Cited by 177
Westphalen, A. C., Hsia, R. Y.-J., Maselli, J. H., Wang, R. C., & Gonzales, R. (2011) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2011.01103.x · Cited by 176
A General Local Reconstruction Approach Based on a Truncated Hilbert Transform
Ye, Y., Yu, H., Wei, Y., & Wang, G. (2007) · International Journal of Biomedical Imaging · doi:10.1155/2007/63634 · Cited by 176
Performance of Ultrasound in the Diagnosis of Appendicitis in Children in a Multicenter Cohort
Mittal, M. K., Dayan, P. S., Macias, C. G., Bachur, R. G., Bennett, J. E., Dudley, N. C., Bajaj, L., Sinclair, K. A., Stevenson, M. D., & Kharbanda, A. B. (2013) · Academic Emergency Medicine · doi:10.1111/acem.12161 · Cited by 176
Westwood, M. E., Al, M., Burgers, L. T., Redekop, K., Lhachimi, S. K., Armstrong, N., Raatz, H., Misso, K., Severens, J. L., & Kleijnen, J. (2013) · Health Technology Assessment · doi:10.3310/hta17090 · Cited by 177
Computer-Simulated Radiation Dose Reduction for Abdominal Multidetector CT of Pediatric Patients
Frush, D. P., Slack, C. C., Hollingsworth, C. L., Bisset, G. S., Donnelly, L. F., Hsieh, J., Lavin-Wensell, T., & Mayo, J. R. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.5.1791107 · Cited by 174
Perfect is the enemy of the very good
Slovis, T. L., & Berdon, W. E. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0669-8 · Cited by 174
Self-citationCT scanning: A major source of radiation exposure
Wiest, P. W., Locken, J. A., Heintz, P. H., & Mettler, F. A. (2002) · Seminars in Ultrasound CT and MRI · doi:10.1016/s0887-2171(02)90011-9 · Cited by 173
Cancer Risks from CT Scans: Now We Have Data, What Next?
Brenner, D. J., & Hall, E. J. (2012) · Radiology · doi:10.1148/radiol.12121248 · Cited by 172
Self-citationde Jong, P. A., Ottink, M. D., Robben, S. G. F., Lequin, M. H., Hop, W. C. J., Hendriks, J. J. E., Paré, P. D., & Tiddens, H. A. W. M. (2004) · Radiology · doi:10.1148/radiol.2312021393 · Cited by 171
Heterojunction structures for reduced noise in large-area and sensitive perovskite x-ray detectors
Zhou, Y., Zhao, L., Ni, Z., Xu, S., Zhao, J., Xiao, X., & Huang, J. (2021) · Science Advances · doi:10.1126/sciadv.abg6716 · Cited by 170
Verdun, F. R., Gutiérrez, D., Vader, J. P., Aroua, A., Alamo, L., Bochud, F. O., & Gudinchet, F. (2008) · European Radiology · doi:10.1007/s00330-008-0963-4 · Cited by 169
Radiation Exposure From Diagnostic Imaging in Severely Injured Trauma Patients
Tien, H. C. N., Tremblay, L. N., Rizoli, S. B., Gelberg, J., Netto, F. A. C. S., Caldwell, C., & Brenneman, F. D. (2007) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e31802d9700 · Cited by 169
McCollough, C. H., Guimarães, L., & Fletcher, J. G. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2754 · Cited by 168
Thyroid Cancer Following Childhood Low-Dose Radiation Exposure: A Pooled Analysis of Nine Cohorts
Lubin, J. H., Adams, M. J., Shore, R. E., Holmberg, E. C., Schneider, A. B., Hawkins, M. M., Robison, L. L., Inskip, P. D., Lundell, M., Johansson, R., et al. (2017) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-3529 · Cited by 166
Minimizing and Communicating Radiation Risk in Pediatric Nuclear Medicine
Fahey, F. H., Treves, S. T., & Adelstein, S. J. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069609 · Cited by 165
Comparison of Different Body Size Parameters for Individual Dose Adaptation in Body CT of Adults
Menke, J. (2005) · Radiology · doi:10.1148/radiol.2362041327 · Cited by 164
Chandarana, H., Godoy, M. C. B., Vlahos, I., Graser, A., Babb, J. S., Leidecker, C., & Macari, M. (2008) · Radiology · doi:10.1148/radiol.2492080359 · Cited by 164
Patient Radiation Dose at CT Urography and Conventional Urography
Nawfel, R. D., Judy, P. F., Schleipman, A. R., & Silverman, S. G. (2004) · Radiology · doi:10.1148/radiol.2321030222 · Cited by 164
Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography
Ludlow, J. B., & Walker, C. (2013) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2013.07.013 · Cited by 162
Wan, M. J., Krahn, M. D., Ungar, W. J., Çaku, E., Sung, L., Medina, L. S., & Doria, A. S. (2008) · Radiology · doi:10.1148/radiol.2502080100 · Cited by 162
Kurian, J., Levin, T. L., Han, B. K., Taragin, B. H., & Weinstein, S. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2791 · Cited by 162
Lung Ultrasound in the Critically Ill Neonate
Lichtenstein, D. A., & Mauriat, P. (2012) · Current Pediatric Reviews · doi:10.2174/157339612802139389 · Cited by 163
DeMarco, J. J., Cagnon, C. H., CODY, D. D., Stevens, D. M., McCollough, C. H., O'Daniel, J. C., & McNitt‐Gray, M. F. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/17/005 · Cited by 161
CT Radiation Dose: Current Controversies and Dose Reduction Strategies
Costello, J. E., Cecava, N. D., Tucker, J. E., & Bau, J. L. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9720 · Cited by 160
Lower Tube Voltage Reduces Contrast Material and Radiation Doses on 16-MDCT Aortography
Nakayama, Y., Awai, K., Funama, Y., Liu, D., Nakaura, T., Tamura, Y., & Yamashita, Y. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0471 · Cited by 159
Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction
Nagayama, Y., Oda, S., Nakaura, T., Tsuji, A., Urata, J., FURUSAWA, M., Utsunomiya, D., Funama, Y., Kidoh, M., & Yamashita, Y. (2018) · Radiographics · doi:10.1148/rg.2018180041 · Cited by 158
Radiation in medicine: Origins, risks and aspirations
Donya, M., Radford, M., ElGuindy, A. M., Firmin, D. N., & Yacoub, M. H. (2014) · Global Cardiology Science and Practice · doi:10.5339/gcsp.2014.57 · Cited by 158
Lung ultrasound compared to chest X‐ray for diagnosis of pediatric pneumonia: A meta‐analysis
Balk, D. S., Lee, C., Schafer, J. M., Welwarth, J., Hardin, J. W., Novack, V., Yarza, S., & Hoffmann, B. (2018) · Pediatric Pulmonology · doi:10.1002/ppul.24020 · Cited by 157
Yeung, A. W. K., Jacobs, R., & Bornstein, M. M. (2019) · Clinical Oral Investigations · doi:10.1007/s00784-019-02907-y · Cited by 157
Patient‐specific radiation dose and cancer risk estimation in CT: Part II. Application to patients
Li, X., Samei, E., Segars, W. P., Sturgeon, G. M., Colsher, J. G., Toncheva, G. I., Yoshizumi, T. T., & Frush, D. P. (2010) · Medical Physics · doi:10.1118/1.3515864 · Cited by 156
Siegel, J. A., Pennington, C. W., & Sacks, B. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.180182 · Cited by 155
Kosloske, A. M., Love, C. L., Rohrer, J. E., Goldthorn, J. F., & Lacey, S. R. (2004) · PEDIATRICS · doi:10.1542/peds.113.1.29 · Cited by 155
Hong, J., Han, K., Jung, J., & Kim, J. S. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.10584 · Cited by 153
Bhatt, M., Joseph, L., Ducharme, F. M., Dougherty, G. E., & McGillivray, D. L. (2009) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2009.00445.x · Cited by 161
Disparities in the Delivery of Pediatric Trauma Care
Petrosyan, M., Guner, Y. S., Emami, C. N., & Ford, H. R. (2009) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3181ad3251 · Cited by 149
Yu, G., Li, J. C.-L., Branovan, D. I., McCormick, S. A., & Schantz, S. P. (2010) · Thyroid · doi:10.1089/thy.2008.0281 · Cited by 149
Pediatric CT: Strategies to Lower Radiation Dose
Zacharias, C., Alessio, A. M., Otto, R. K., Iyer, R. S., Phillips, G. S., Swanson, J. O., & Thapa, M. M. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9026 · Cited by 148
Barghouth, G., Prior, J. O., Lepori, D., Duvoisin, B., Schnyder, P. A., & Gudinchet, F. (2002) · European Radiology · doi:10.1007/s00330-001-1218-9 · Cited by 148
Current management of appendicitis
Morrow, S. E., & Newman, K. D. (2007) · Seminars in Pediatric Surgery · doi:10.1053/j.sempedsurg.2006.10.005 · Cited by 147
EOS 2D/3D X-ray imaging system: a systematic review and economic evaluation
McKenna, C., Wade, R., Faria, R., Yang, H., Stirk, L., Gummerson, N. W., Sculpher, M. J., & Woolacott, N. F. (2012) · Health Technology Assessment · doi:10.3310/hta16140 · Cited by 146
Chodick, G., Ronckers, C. M., Shalev, V., & Ron, E. (2007) · PubMed · Cited by 146
Higano, N. S., Spielberg, D. R., Fleck, R. J., Schapiro, A. H., Walkup, L. L., Hahn, A. D., Tkach, J. A., Kingma, P. S., Merhar, S. L., Fain, S. B., et al. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201711-2287oc · Cited by 145
Mazonakis, M., Tzedakis, A., Damilakis, J. E., & Gourtsoyiannis, N. (2006) · European Radiology · doi:10.1007/s00330-006-0417-9 · Cited by 145
Comparison of radiation levels from computed tomography and conventional dental radiographs
Ngan, D. C. S., Kharbanda, O. P., Geenty, J. P., & Darendeliler, M. A. (2003) · Australasian Orthodontic Journal · doi:10.2478/aoj-2003-0009 · Cited by 143
Reducing Radiation Dose Associated with Pediatric CT by Decreasing Unnecessary Examinations
Donnelly, L. F. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.184.2.01840655 · Cited by 143
Kurt, B. A., Winterhalter, K., Connors, R. H., Betz, B. W., & Winters, J. W. (2006) · PEDIATRICS · doi:10.1542/peds.2005-2719 · Cited by 143
Haaga, J. R. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770289 · Cited by 143
Use of Medical Imaging Procedures With Ionizing Radiation in Children
Dorfman, A. L., Fazel, R., Einstein, A. J., Applegate, K. E., Krumholz, H. M., Wang, Y., Christodoulou, E., Chen, J., Sanchez, R., & Nallamothu, B. K. (2011) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpediatrics.2010.270 · Cited by 142
Low, R. N., & Barone, R. M. (2012) · Annals of Surgical Oncology · doi:10.1245/s10434-012-2236-3 · Cited by 141
Radiation Dose Reduction with Hybrid Iterative Reconstruction for Pediatric CT
Singh, S., Kalra, M. K., Shenoy‐Bhangle, A. S., Saini, A., Gervais, D. A., Westra, S. J., & Thrall, J. H. (2012) · Radiology · doi:10.1148/radiol.12110268 · Cited by 141
Intra-Abdominal Solid Organ Injury in Children: Diagnosis and Treatment
Gaines, B. A. (2009) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3181adc17a · Cited by 141
Cohen, M. S., Eidem, B. W., Cetta, F., Fogel, M. A., Frommelt, P. C., Gáname, J., Han, B., Kimball, T. R., Johnson, R. K., Mertens, L., et al. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.04.002 · Cited by 140
Is the Use of Pan-Computed Tomography for Blunt Trauma Justified? A Prospective Evaluation
Tillou, A., Gupta, M., Baraff, L. J., Schriger, D. L., Hoffman, J. R., Hiatt, J. R., & Cryer, H. M. (2009) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3181b5f2eb · Cited by 139
Diagnostic Imaging and Negative Appendectomy Rates in Children: Effects of Age and Gender
Bachur, R. G., Hennelly, K. E., Callahan, M. J., Chen, C., & Monuteaux, M. C. (2012) · PEDIATRICS · doi:10.1542/peds.2011-3375 · Cited by 139
Diagnosis and Guided Reduction of Forearm Fractures in Children Using Bedside Ultrasound
Chen, L., Kim, Y., & Moore, C. L. (2007) · Pediatric Emergency Care · doi:10.1097/pec.0b013e318128f85d · Cited by 139
Bellolio, F., Heien, H. C., Sangaralingham, L. R., Jeffery, M. M., Campbell, R. L., Cabrera, D., Shah, N. D., & Hess, E. P. (2017) · Western Journal of Emergency Medicine · doi:10.5811/westjem.2017.5.34152 · Cited by 149
Brady, S. L., & Kaufman, R. A. (2012) · Radiology · doi:10.1148/radiol.12120131 · Cited by 137
Computed tomographic imaging of the airways: relationship to structure and function
de Jong, P. A., Müller, N. L., Paré, P. D., & Coxson, H. O. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00007105 · Cited by 171
Atypical Clinical Features of Pediatric Appendicitis
Becker, T., Kharbanda, A. B., & Bachur, R. G. (2006) · Academic Emergency Medicine · doi:10.1197/j.aem.2006.08.009 · Cited by 138
Dose and Pitch Relationship for a Particular Multislice CT Scanner
Mahesh, M., Scatarige, J. C., Cooper, J., & Fishman, E. K. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.6.1771273 · Cited by 138
The argument for operative approach to asymptomatic lung lesions
Singh, R. R., & Davenport, M. (2015) · Seminars in Pediatric Surgery · doi:10.1053/j.sempedsurg.2015.02.003 · Cited by 137
Turner, A. C., Zhang, D., Kim, H. J., DeMarco, J. J., Cagnon, C. H., Angel, E., CODY, D. D., Stevens, D. M., Primak, A. N., McCollough, C. H., et al. (2009) · Medical Physics · doi:10.1118/1.3117683 · Cited by 135
Poortman, P., Oostvogel, H. J. M., Bosma, E., Lohle, P. N. M., Cuesta, M. A., Klerk, E. S. M. D. L., & Hamming, J. F. (2009) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2008.12.003 · Cited by 135
Informing Parents About CT Radiation Exposure in Children: It's OK to Tell Them
Larson, D. B., Rader, S. B., Forman, H. P., & Fenton, L. Z. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2248 · Cited by 134
Should a Head-Injured Child Receive a Head CT Scan? A Systematic Review of Clinical Prediction Rules
Maguire, J. L., Boutis, K., Uleryk, E. M., Laupacis, A., & Parkin, P. C. (2009) · PEDIATRICS · doi:10.1542/peds.2009-0075 · Cited by 140
Tzedakis, A., Damilakis, J. E., Perisinakis, K., Stratakis, J., & Gourtsoyiannis, N. (2005) · Medical Physics · doi:10.1118/1.1924309 · Cited by 134
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · Medical Physics · doi:10.1118/1.1415074 · Cited by 134
Self-citationProblems and preferences in pediatric imaging
Thukral, B. B. (2015) · Indian journal of radiology and imaging - new series/Indian journal of radiology and imaging/Indian Journal of Radiology & Imaging · doi:10.4103/0971-3026.169466 · Cited by 131
Radiation Doses and Risks in Chest Computed Tomography Examinations
Huda, W. (2007) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200611-172ht · Cited by 131
Beauchamp, M., Ditchfield, M., Babl, F., Kean, M., Catroppa, C., Yeates, K., & Anderson, V. (2011) · Journal of Neurotrauma · doi:10.1089/neu.2010.1712 · Cited by 124
Darge, K., Papadopoulou, F., Ntoulia, A., Bulas, D., Coley, B. D., Fordham, L. A., Paltiel, H. J., McCarville, M. B., Volberg, F. M., Cosgrove, D. O., et al. (2013) · Pediatric Radiology · doi:10.1007/s00247-013-2746-6 · Cited by 130
Highly Catalytic Nanodots with Renal Clearance for Radiation Protection
Zhang, X., Zhang, J., Wang, J., Jiang, Y., Chen, J., Shen, X., Deng, J., Deng, D., Long, W., Sun, Y., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b00321 · Cited by 130
Standard-Dose and 50%—Reduced-Dose Chest CT: Comparing the Effect on Image Quality
Prasad, S. R., Wittram, C., Shepard, J.-A. O., McLoud, T. C., & Rhea, J. T. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.2.1790461 · Cited by 130
Krille, L., Dreger, S., Schindel, R., Albrecht, T., Asmussen, M., Barkhausen, J., Berthold, J. D., Chavan, A., Claussen, C. D., Forsting, M., et al. (2017) · Radiation and Environmental Biophysics · doi:10.1007/s00411-017-0694-5 · Cited by 130
Metadata
- Authors
- Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E.
- Affiliations
- Columbia University (US)
- Columbia University Irving Medical Center (US)
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2001-02
- Volume
- 176
- Issue
- 2
- Pages
- 289-296
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2138025351
- Cited by
- 3,222
- References
- 79
- Citations by year
- 2026: 44 · 2025: 92 · 2024: 78 · 2023: 115 · 2022: 116 · 2021: 134 · 2020: 148 · 2019: 137 · 2018: 124 · 2017: 141 · 2016: 190 · 2015: 186 · 2014: 179 · 2013: 176 · 2012: 213
- FWCI
- 60.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Roentgenology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ca077285-03)
- National Cancer Institute (CA77285)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Keywords
- pediatric computed tomography, radiation-induced cancer, age at diagnosis, linear no-threshold model, low-dose radiation risk, abdominal CT, head CT, benefits and risks
- MeSH terms
- Adolescent, Cause of Death, Child, Child, Preschool, Female, Humans, Infant, Infant, Newborn, Male, Neoplasms, Radiation-Induced, Tomography, X-Ray Computed, Risk Assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review