Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 177

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Feasibility of Outpatient Fully Integrated Closed-Loop Control

Open access
Kovatchev, Boris P., Renard, Eric, Cobelli, Claudio, Zisser, Howard C., Keith-Hynes, Patrick, Anderson, Stacey M., Brown, Sue A., Chernavvsky, Daniel R., Breton, Marc D., Farret, Anne, Pelletier, Marie-Josée, Place, Jérôme, Bruttomesso, Daniela, Del Favero, Simone, Visentin, Roberto, Filippi, Alessio, Scotton, Rachele, Avogaro, Angelo, Doyle, Francis J. · 2013 · Diabetes Care

Abstract

OBJECTIVE: To evaluate the feasibility of a wearable artificial pancreas system, the Diabetes Assistant (DiAs), which uses a smart phone as a closed-loop control platform. RESEARCH DESIGN AND METHODS: Twenty patients with type 1 diabetes were enrolled at the Universities of Padova, Montpellier, and Virginia and at Sansum Diabetes Research Institute. Each trial continued for 42 h. The United States studies were conducted entirely in outpatient setting (e.g., hotel or guest house); studies in Italy and France were hybrid hospital–hotel admissions. A continuous glucose monitoring/pump system (Dexcom Seven Plus/Omnipod) was placed on the subject and was connected to DiAs. The patient operated the system via the DiAs user interface in open-loop mode (first 14 h of study), switching to closed-loop for the remaining 28 h. Study personnel monitored remotely via 3G or WiFi connection to DiAs and were available on site for assistance. RESULTS: The total duration of proper system communication functioning was 807.5 h (274 h in open-loop and 533.5 h in closed-loop), which represented 97.7% of the total possible time from admission to discharge. This exceeded the predetermined primary end point of 80% system functionality. CONCLUSIONS: This study demonstrated that a contemporary smart phone is capable of running outpatient closed-loop control and introduced a prototype system (DiAs) for further investigation. Following this proof of concept, future steps should include equipping insulin pumps and sensors with wireless capabilities, as well as studies focusing on control efficacy and patient-oriented clinical outcomes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc12-1965

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 18

  1. Pickup, 1978, Continuous subcutaneous insulin infusion: an approach to achieving normoglycaemia, BMJ, 1, 204, 10.1136/bmj.1.6107.204 · DOI · Paper page
  2. Tamborlane, 1979, Reduction to normal of plasma glucose in juvenile diabetes by subcutaneous administration of insulin with a portable infusion pump, N Engl J Med, 300, 573, 10.1056/NEJM197903153001101 · DOI · Paper page
  3. Mastrototaro, 2000, The MiniMed continuous glucose monitoring system, Diabetes Technol Ther, 2, S13, 10.1089/15209150050214078 · DOI · Paper page
  4. Bode, 2000, Clinical utility of the continuous glucose monitoring system, Diabetes Technol Ther, 2, S35, 10.1089/15209150050214104 · DOI
  5. Bellazzi, 2001, The subcutaneous route to insulin-dependent diabetes therapy: closed-loop and partially closed-loop control strategies for insulin delivery and measuring glucose concentration, IEEE Eng Med Biol, 20, 54, 10.1109/51.897828 · DOI
  6. Hovorka, 2004, Closing the loop: the adicol experience, Diabetes Technol Ther, 6, 307, 10.1089/152091504774197990 · DOI
  7. Steil, 2006, Feasibility of automating insulin delivery for the treatment of type 1 diabetes, Diabetes, 55, 3344, 10.2337/db06-0419 · DOI · Paper page
  8. Weinzimer, 2008, Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas, Diabetes Care, 31, 934, 10.2337/dc07-1967 · DOI · Paper page
  9. Hovorka, 2010, Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial, Lancet, 375, 743, 10.1016/S0140-6736(09)61998-X · DOI · Paper page
  10. El-Khatib, 2010, A bihormonal closed-loop artificial pancreas for type 1 diabetes, Sci Transl Med, 2, 27ra27, 10.1126/scitranslmed.3000619 · DOI · Paper page
  11. Breton, 2012, Fully integrated artificial pancreas in type 1 diabetes: modular closed-loop glucose control maintains near normoglycemia, Diabetes, 61, 2230, 10.2337/db11-1445 · DOI · Paper page
  12. Cobelli, 2011, Artificial pancreas: past, present, future, Diabetes, 60, 2672, 10.2337/db11-0654 · DOI · Paper page
  13. Kovatchev, 2009, Control to range for diabetes: functionality and modular architecture, J Diabetes Sci Tech, 3, 1058, 10.1177/193229680900300509 · DOI
  14. O’Grady, 2012, The use of an automated, portable glucose control system for overnight glucose control in adolescents and young adults with type 1 diabetes, Diabetes Care, 35, 2182, 10.2337/dc12-0761 · DOI
  15. Cobelli, 2012, Pilot studies of wearable outpatient artificial pancreas in type 1 diabetes, Diabetes Care, 35, e65, 10.2337/dc12-0660 · DOI
  16. Hughes, 2010, Hypoglycemia prevention via pump attenuation and red-yellow-green “traffic” lights using continuous glucose monitoring and insulin pump data, J Diabetes Sci Tech, 4, 1146, 10.1177/193229681000400513 · DOI
  17. Patek, 2012, DelFaverok S, Breton M, Dalla Man C, Renard E, Zisser H, Doyle FJ III, Cobelli C, Kovatchev BP. Modular closed-loop control of diabetes, Trans Biomed Engineer, 29, 2986, 10.1109/TBME.2012.2192930 · DOI · Paper page
  18. Beck, 2013, Challenges for outpatient closed loop studies: how to assess efficacy, Diabetes Technol Ther, 15, 1, 10.1089/dia.2012.0289 · DOI

Cited by

See all 177

Metadata

Authors
Kovatchev, B. P., Renard, E., Cobelli, C., Zisser, H. C., Keith-Hynes, P., Anderson, S. M., Brown, S. A., Chernavvsky, D. R., Breton, M. D., Farret, A., Pelletier, M.-J., Place, J., Bruttomesso, D., Del Favero, S., Visentin, R., Filippi, A., Scotton, R., Avogaro, A., & Doyle, F. J.
Venue
Diabetes Care
Published
2013-06-12
Volume
36
Issue
7
Pages
1851-1858
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2029069327
Cited by
177
References
3
FWCI
23.11
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.