The Effect of Real-Time Continuous Glucose Monitoring in Pregnant Women With Diabetes
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To assess whether intermittent real-time continuous glucose monitoring (CGM) improves glycemic control and pregnancy outcome in unselected women with pregestational diabetes. RESEARCH DESIGN AND METHODS: A total of 123 women with type 1 diabetes and 31 women with type 2 diabetes were randomized to use real-time CGM for 6 days at 8, 12, 21, 27, and 33 weeks in addition to routine care, including self-monitored plasma glucose seven times daily, or routine care only. To optimize glycemic control, real-time CGM readings were evaluated by a diabetes caregiver. HbA1c, self-monitored plasma glucose, severe hypoglycemia, and pregnancy outcomes were recorded, with large-for-gestational-age infants as the primary outcome. RESULTS: Women assigned to real-time CGM (n = 79) had baseline HbA1c similar to that of women in the control arm (n = 75) (median 6.6 [range 5.3–10.0] vs. 6.8% [5.3–10.7]; P = 0.67) (49 [34–86] vs. 51 mmol/mol [34–93]). Forty-nine (64%) women used real-time CGM per protocol. At 33 weeks, HbA1c (6.1 [5.1–7.8] vs. 6.1% [4.8–8.2]; P = 0.39) (43 [32–62] vs. 43 mmol/mol [29–66]) and self-monitored plasma glucose (6.2 [4.7–7.9] vs. 6.2 mmol/L [4.9–7.9]; P = 0.64) were comparable regardless of real-time CGM use, and a similar fraction of women had experienced severe hypoglycemia (16 vs. 16%; P = 0.91). The prevalence of large-for-gestational-age infants (45 vs. 34%; P = 0.19) and other perinatal outcomes were comparable between the arms. CONCLUSIONS: In this randomized trial, intermittent use of real-time CGM in pregnancy, in addition to self-monitored plasma glucose seven times daily, did not improve glycemic control or pregnancy outcome in women with pregestational diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“There was also lower incidence of large for gestational age (odds ratio [OR], 0.51; 95% CI, 0$28–0.90; P = .0210)”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [123]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source doesn’t support the claim as written.
In the citing paper
“The CONCEPTT study’s participants were randomly assigned to either CGM in addition to capillary glucose monitoring or capillary glucose monitoring alone and showed a modest reduction in A1C levels, increased time in target, reduced hyperglycemia, and less glycemic variability.123”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [123]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“and 1-day shorter length of hospital stay (P = .0091) in women with T1D on multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII).”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [123]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“fewer incidences of neonatal hypoglycemia (0.45; 95% CI, 0.22–0.89; P = .0250)”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [123]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“fewer neonatal intensive care admissions lasting more than 24 hours (0.48; 95% CI, 0.26–0.86; P = .0157)”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [123]
Experimental — accuracy not yet measured
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intrauterine growth curves based on ultrasonically estimated foetal weights
Maršál, K., Persson, P., Larsen, T., Lilja, H., Selbing, A., & Sultan, B. (1996) · Acta Paediatrica · doi:10.1111/j.1651-2227.1996.tb14164.x · Cited by 1,865 · cited 1×
“, infant birth weight $90th centile adjusted for sex and gestational age (31)] was predefined as the primary outcome of this study.”
MethodContinuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Clausen, T. D., Mathiesen, E. R., Hansen, T., Pedersen, O., Jensen, D. M., Lauenborg, J., & Damm, P. (2008) · Diabetes Care · doi:10.2337/dc07-1596 · Cited by 724
Self-citationPickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541 · cited 2×
“Recent data indicate the importance of frequent real-time CGM use (16).”
BackgroundDeiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Murphy, H. R., Rayman, G., Lewis, K., Kelly, S., Johal, B., Duffield, K., Fowler, D., Campbell, P. J., & Temple, R. C. (2008) · BMJ · doi:10.1136/bmj.a1680 · Cited by 358 · cited 6×
“However, the relatively low number of per-protocol users has also been observed in the nonpregnant population (17,18), and the average use of CGM was comparable to the former study on pregnant women (27).”
BackgroundResultInfluentialHbA1c levels are significantly lower in early and late pregnancy
Nielsen, L. R., Ekbom, P., Damm, P., Glümer, C., Frandsen, M. M., Jensen, D. M., & Mathiesen, E. R. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1200 · Cited by 331
Self-citationEffectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Factors Predictive of Use and of Benefit From Continuous Glucose Monitoring in Type 1 Diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0889 · Cited by 249
Raccah, D., Sulmont, V., Reznik, Y., Guerci, B., Renard, E., Hanaire, H., Jeandidier, N., & Nicolino, M. (2009) · Diabetes Care · doi:10.2337/dc09-0750 · Cited by 237 · cited 1×
“However, the relatively low number of per-protocol users has also been observed in the nonpregnant population (17,18), and the average use of CGM was comparable to the former study on pregnant women (27).”
ResultLudvigsson, J., & Hanas, R. (2003) · Pediatrics · doi:10.1542/peds.111.5.933 · Cited by 228
O’Connell, M. A., Donath, S., O’Neal, D. N., Colman, P. G., Ambler, G. R., Jones, T. W., Davis, E. A., & Cameron, F. J. (2009) · Diabetologia · doi:10.1007/s00125-009-1365-0 · Cited by 211
Improved Pregnancy Outcome in Type 1 Diabetic Women With Microalbuminuria or Diabetic Nephropathy
Ringholm Nielsen, L., Damm, P., & Mathiesen, E. R. (2009) · Diabetes Care · doi:10.2337/dc08-1526 · Cited by 204 · cited 2×
“135/85 mmHg, treatment was initiated (29).”
BackgroundSelf-citationHypoglycemia in Pregnant Women With Type 1 Diabetes
Nielsen, L. R., Pedersen-Bjergaard, U., Thorsteinsson, B., Johansen, M., Damm, P., & Mathiesen, E. R. (2008) · Diabetes Care · doi:10.2337/dc07-1066 · Cited by 204 · cited 8×
“Obstetrical ultrasound scanning was performed at all five routine visits and when indicated (7).”
BackgroundMethodInfluentialSelf-citationClosed-Loop Insulin Delivery During Pregnancy Complicated by Type 1 Diabetes
Murphy, H. R., Elleri, D., Allen, J. M., Harris, J., Simmons, D., Rayman, G., Temple, R., Dunger, D. B., Haidar, A., Nodale, M., et al. (2011) · Diabetes Care · doi:10.2337/dc10-1796 · Cited by 137
Pregnancy-induced sight-threatening diabetic retinopathy in women with type 1 diabetes
Vestgaard, M., Ringholm, L., Laugesen, C. S., Rasmussen, K. L., Damm, P., & Mathiesen, E. R. (2010) · Diabetic Medicine · doi:10.1111/j.1464-5491.2010.02958.x · Cited by 121 · cited 1×
“Diabetic retinopathy was diagnosed with retinal photos at first pregnancy visit (30).”
BackgroundSelf-citationThe Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0846 · Cited by 120
Pathophysiology of postprandial hyperglycaemia in women with type 1 diabetes during pregnancy
Murphy, H. R., Elleri, D., Allen, J. M., Harris, J. R., Simmons, D. S., Rayman, G. A., Temple, R., Umpleby, A. M., Dunger, D. B., Haidar, A., et al. (2011) · Diabetologia · doi:10.1007/s00125-011-2363-6 · Cited by 120 · cited 1×
“The negative finding of this trial may lead to intensified focus on dietary advice, including carbohydrate counting, stable day-to-day carbohydrate intake, especially in late gestation (36), and weight gain within the Institute of Medicine recommendations (37).”
BackgroundRiveline, J.-P., Schaepelynck, P., Chaillous, L., Renard, E., Sola-Gazagnes, A., Penfornis, A., Tubiana-Rufi, N., Sulmont, V., Catargi, B., Lukas, C., et al. (2012) · Diabetes Care · doi:10.2337/dc11-2021 · Cited by 94
Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review
Hoeks, L. B. E. A., Greven, W. L., & de Valk, H. W. (2011) · Diabetic Medicine · doi:10.1111/j.1464-5491.2010.03177.x · Cited by 88
Psychosocial factors associated with use of continuous glucose monitoring
Ritholz, M. D., Atakov‐Castillo, A., Beste, M., Beverly, E. A., Leighton, A., Weinger, K., & Wolpert, H. (2010) · Diabetic Medicine · doi:10.1111/j.1464-5491.2010.03061.x · Cited by 88
Klemetti, M. M., Nuutila, M. E., Tikkanen, M., Kari, M. A., Hiilesmaa, V., & Teramo, K. (2012) · Diabetologia · doi:10.1007/s00125-012-2627-9 · Cited by 82
Real-Life Utilization of Real-Time Continuous Glucose Monitoring: The Complete Picture
Ramchandani, N., Arya, S., Ten, S., & Bhandari, S. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500407 · Cited by 82
Birth Size Distribution in 3,705 Infants Born to Mothers With Type 1 Diabetes
Persson, M., Pasupathy, D., Hanson, U., & Norman, M. (2011) · Diabetes Care · doi:10.2337/dc10-2406 · Cited by 73
Insulin during pregnancy, labour and delivery
de Valk, H. W., & Visser, G. H. A. (2010) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2010.10.002 · Cited by 72 · cited 1×
“The major barrier in the strive for strict maternal glycemic control is the risk of severe hypoglycemia (1), occurring up to five times more frequently in early pregnancy than in the period prior to pregnancy in women with type 1 diabetes (7).”
BackgroundPetrovski, G., Dimitrovski, Č., Bogoev, M. K., Milenković, T., Ahmeti, I., & Bitovska, I. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0081 · Cited by 59
Secher, A. L., Madsen, A. B., Ringholm, L., Barfred, C., Stage, E., Andersen, H. U., Damm, P., & Mathiesen, E. R. (2012) · Diabetic Medicine · doi:10.1111/j.1464-5491.2011.03426.x · Cited by 51 · cited 6×
“This survey demonstrated that real-time CGM inaccuracy compared with self-monitored plasma glucose values, technical challenges, and skin irritation limits compliance (25), which is in line with previous studies of nonpregnant (12,32–35) and pregnant (27) patients.”
BackgroundMethodResultInfluentialSelf-citationCooke, D., Hurel, S. J., Casbard, A., Steed, L., Walker, S., Meredith, S., Nunn, A. J., Manca, A., Sculpher, M., Barnard, M., et al. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2009.02723.x · Cited by 46
Insulin treatment in diabetic pregnancy
Mathiesen, E. R., & Vaz, J. A. (2008) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.876 · Cited by 32
Self-citationKerssen, A., de Valk, H. W., & Visser, G. H. A. (2006) · Prenatal Diagnosis · doi:10.1002/pd.1340 · Cited by 31
Persson, M., Pasupathy, D., Hanson, U., & Norman, M. (2012) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2012.03277.x · Cited by 28 · cited 1×
“Large-for-gestational-age infants to mothers with diabetes are at increased risk for birth trauma, transient tachypnea, and neonatal hypoglycemia (5), and maternal diabetes in pregnancy is associated to later-life morbidity in the offspring (6).”
BackgroundContinuous Glucose Monitoring System With an Alarm
Worm, D., Ringholm, L., Mathiesen, E. R., & Nørgaard, K. (2006) · Diabetes Care · doi:10.2337/dc06-1408 · Cited by 16
Self-citationContinuous glucose monitoring and insulin pump therapy for diabetes in pregnancy
Combs, C. A. (2012) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2012.670409 · Cited by 16
Continuous glucose monitoring‐enabled insulin‐pump therapy in diabetic pregnancy
Secher, A. L., Schmidt, S., Nørgaard, K., & Mathiesen, E. R. (2010) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.3109/00016349.2010.498499 · Cited by 13 · cited 2×
“Real-time CGM had been used for several years in our clinic, and we have previously published case reports suggesting beneficial effects of real-time CGM in pregnancy (24,26).”
BackgroundMethodSelf-citation
Cited by
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
Feig, D. S., Donovan, L. E., Corcoy, R., Murphy, K. E., Amiel, S. A., Hunt, K. F., Asztalos, E., Barrett, J. F. R., Sanchez, J. J., de Leiva, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32400-5 · Cited by 803
Hod, M., Kapur, A., Sacks, D. A., Hadar, E., Agarwal, M., Di Renzo, G. C., Roura, L. C., McIntyre, H. D., Morris, J. L., & Divakar, H. (2015) · International Journal of Gynecology & Obstetrics · doi:10.1016/s0020-7292(15)30033-3 · Cited by 767
The importance of nutrition in pregnancy and lactation: lifelong consequences
Marshall, N. E., Abrams, B., Barbour, L. A., Catalano, P., Christian, P., Friedman, J. E., Hay, W. W., Hernandez, T. L., Krebs, N. F., Oken, E., et al. (2022) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2021.12.035 · Cited by 709
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Metadata
- Authors
- Secher, A. L., Ringholm, L., Andersen, H. U., Damm, P., & Mathiesen, E. R.
- Affiliations
- University of Copenhagen (DK)
- Rigshospitalet (DK)
- Steno Diabetes Center, Gentofte, Denmark
- Corresponding author
- Secher, Anna L.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2013-06-12
- Volume
- 36
- Issue
- 7
- Pages
- 1877-1883
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- PMC
- PMC3687305
- OpenAlex
- W2107291591
- Cited by
- 214
- References
- 36
- Citations by year
- 2026: 9 · 2025: 17 · 2024: 15 · 2023: 9 · 2022: 17 · 2021: 18 · 2020: 12 · 2019: 18 · 2018: 26 · 2017: 15 · 2016: 20 · 2015: 14 · 2014: 11 · 2013: 12
- FWCI
- 21.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Diabetes Care (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Research at the University of Copenhagen (University of Copenhagen) (submittedVersion)
- Topics
- Health Sciences › Medicine › Obstetrics and Gynecology › Gestational Diabetes Research and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- real-time continuous glucose monitoring, pregnancy, pregestational diabetes, type 1 diabetes, type 2 diabetes, glycemic control, HbA1c, severe hypoglycemia, large for gestational age, perinatal outcomes, gestational diabetes management
- MeSH terms
- Adult, Blood Glucose, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Female, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Pregnancy, Pregnancy Outcome, Blood Glucose Self-Monitoring, Treatment Outcome, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.