The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Implementation of a Safe and Effective Insulin Infusion Protocol in a Medical Intensive Care Unit
Open accessAbstract
OBJECTIVE—In a recent randomized controlled trial, lowering blood glucose levels to 80–110 mg/dl improved clinical outcomes in critically ill patients. In that study, the insulin infusion protocol (IIP) used to normalize blood glucose levels provided valuable guidelines for adjusting insulin therapy. In our hands, however, ongoing expert supervision was required to effectively manage the insulin infusions. This work describes our early experience with a safe, effective, nurse-implemented IIP that provides detailed insulin dosing instructions and requires minimal physician input. RESEARCH DESIGN AND METHODS—We collected data from 52 medical intensive care unit (MICU) patients who were placed on the IIP. Blood glucose levels were the primary outcome measurement. Relevant clinical variables and insulin requirements were also recorded. MICU nurses were surveyed regarding their experience with the IIP. RESULTS—To date, our IIP has been employed 69 times in 52 patients admitted to an MICU. Using the IIP, the median time to reach target blood glucose levels (100–139 mg/dl) was 9 h. Once blood glucose levels fell below 140 mg/dl, 52% of 5,808 subsequent hourly blood glucose values fell within our narrow target range; 66% within a “clinically desirable” range of 80–139 mg/dl; and 93% within a “clinically acceptable” range of 80–199 mg/dl. Only 20 (0.3%) blood glucose values were <60 mg/dl, none of which resulted in clinically significant adverse events. In general, the IIP was readily accepted by our MICU nursing staff, most of whom rated the protocol as both clinically effective and easy to use. CONCLUSIONS—Our nurse-implemented IIP is safe and effective in improving glycemic control in critically ill patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
APACHE II: A severity of disease classification system
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Critical Care Medicine · doi:10.1097/00003246-198510000-00009 · Cited by 13,664
APACHE II-A Severity of Disease Classification System: Reply
Knaus, W. A., Draper, E. A., Wagner, D. P., & Zimmerman, J. E. (1986) · Critical Care Medicine · doi:10.1097/00003246-198608000-00028 · Cited by 13,376
Intensive insulin therapy in critically ill patients.
Van den Berghe, G., Wouters, P., Weekers, F., Verwaest, C., Bruyninckx, F., Schetz, M., Vlasselaers, D., Ferdinande, P., Lauwers, P., & Bouillon, R. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011300 · Cited by 9,977
Hyperglycemia: an independent marker of in-hospital mortality in patients with undiagnosed diabetes
Umpierrez, G. E., Isaacs, S. D., Bazargan, N., You, X., Thaler, L. M., & Kitabchi, A. E. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.3.8341 · Cited by 2,195
Capes, S. E., Hunt, D., Malmberg, K., & Gerstein, H. C. (2000) · The Lancet · doi:10.1016/s0140-6736(99)08415-9 · Cited by 2,187
Malmberg, K., Rydén, L., Efendic, S., Herlitz, J., Nicol, P., Waldenstrom, A., Wedel, H., & Welin, L. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00126-k · Cited by 1,560 · cited 2×
“Existing published IIPs are disadvantaged by excessively conservative blood glucose targets (2,4,20– 22) and/or by oversimplified IIP directions, necessitating expert supervision or frequent deviation from protocol (2,4).”
BackgroundMalmberg, K. (1997) · BMJ · doi:10.1136/bmj.314.7093.1512 · Cited by 1,286
Furnary, A. P., Zerr, K. J., Grunkemeier, G. L., & Starr, A. (1999) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(99)00014-4 · Cited by 1,230
Malmberg, K., Norhammar, A., Wedel, H., & Rydén, L. (1999) · Circulation · doi:10.1161/01.cir.99.20.2626 · Cited by 847
Parsons, M. W., Barber, P. A., Desmond, P. M., Baird, T. A., Darby, D. G., Byrnes, G., Tress, B. M., & Davis, S. M. (2002) · Annals of Neurology · doi:10.1002/ana.10241 · Cited by 606
Cited by
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470
Moghissi, E. S., Korytkowski, M. T., DiNardo, M., Einhorn, D., Hellman, R., Hirsch, I. B., Inzucchi, S. E., Ismail-Beigi, F., Kirkman, M. S., & Umpierrez, G. E. (2009) · Diabetes Care · doi:10.2337/dc09-9029 · Cited by 1,444
Self-citationPreiser, J.-C., Devos, P., Ruiz-Santana, S., Mélot, C., Annane, D., Groeneveld, J., Iapichino, G., Leverve, X., Nitenberg, G., Singer, P., et al. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1585-2 · Cited by 911
Umpierrez, G. E., Smiley, D., Zisman, A., Prieto, L. M., Palacio, A., Ceron, M., Puig, A., & Mejia, R. (2007) · Diabetes Care · doi:10.2337/dc07-0295 · Cited by 671
Handelsman, Y., Bloomgarden, Z. T., Grunberger, G., Umpierrez, G., Zimmerman, R. S., Bailey, T. S., Blonde, L., Bray, G. A., Cohen, A. J., Dagogo-Jack, S., et al. (2015) · Endocrine Practice · doi:10.4158/ep15672.gl · Cited by 629
Jacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
Handelsman, Y., Bloomgarden, Z. T., Grunberger, G., Umpierrez, G., Zimmerman, R. S., Bailey, T. S., Blonde, L., Bray, G. A., Cohen, A. J., Dagogo-Jack, S., et al. (2015) · Endocrine Practice · doi:10.4158/ep15672.glsuppl · Cited by 559
Moghissi, E. S., Korytkowski, M. T., DiNardo, M., Einhorn, D., Hellman, R., Hirsch, I. B., Inzucchi, S. E., Ismail-Beigi, F., Kirkman, M. S., & Umpierrez, G. E. (2009) · Endocrine Practice · doi:10.4158/ep09102.ra · Cited by 518
Self-citationHyperglycaemic index as a tool to assess glucose control: a retrospective study
Vogelzang, M., van der Horst, I. C., & Nijsten, M. W. (2004) · Critical Care · doi:10.1186/cc2840 · Cited by 507
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Deedwania, P., Kosiborod, M., Barrett, E., Ceriello, A., Isley, W., Mazzone, T., & Raskin, P. (2008) · Circulation · doi:10.1161/circulationaha.107.188629 · Cited by 488
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
Management of Hyperglycemia in the Hospital Setting
Inzucchi, S. E. (2006) · New England Journal of Medicine · doi:10.1056/nejmcp060094 · Cited by 391
Self-citationAragon, D. (2006) · American Journal of Critical Care · doi:10.4037/ajcc2006.15.4.370 · Cited by 370
Kosiborod, M. (2009) · JAMA · doi:10.1001/jama.2009.496 · Cited by 364
Perioperative Glycemic Control: An Evidence-based Review
Lipshutz, A. K. M., Gropper, M. A., Warner, D. S., & Warner, M. A. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181948a80 · Cited by 259
Perioperative management of hyperglycemia and diabetes in cardiac surgery patients
Galindo, R. J., Fayfman, M., & Umpierrez, G. E. (2018) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2017.10.005 · Cited by 95
Glucose meter performance criteria for tight glycemic control estimated by simulation modeling
Karon, B. S., Boyd, J. C., & Klee, G. G. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.145367 · Cited by 94
Juneja, R., Roudebush, C. P., Nasraway, S. A., Golas, A. A., Jacobi, J., Carroll, J., Nelson, D., Abad, V. J., & Flanders, S. J. (2009) · Critical Care · doi:10.1186/cc8129 · Cited by 86
Newton, C. A., Smiley, D., Bode, B. W., Kitabchi, A. E., Davidson, P. C., Jacobs, S., Steed, R. D., Stentz, F., Peng, L., Mulligan, P., et al. (2010) · Journal of Hospital Medicine · doi:10.1002/jhm.816 · Cited by 84
In-hospital management of diabetes
Malcolm, J., Halperin, I., Miller, D. B., Moore, S., Nerenberg, K. A., Woo, V., & Yu, C. H. (2018) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2017.10.014 · Cited by 55
Besch, G., Perrotti, A., Mauny, F., Puyraveau, M., Baltres, M., Flicoteaux, G., Salomon du Mont, L., Barrucand, B., Samain, E., Chocron, S., et al. (2017) · Anesthesiology · doi:10.1097/aln.0000000000001838 · Cited by 38
Hermayer, K. L., Neal, D. E., Hushion, T. V., Irving, M. G., Arnold, P. C., Kozlowski, L., Stroud, M. R., Kerr, F. B., & Kratz, J. M. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0225 · Cited by 38
ICU care for patients with diabetes
Umpierrez, G. E., & Kitabchi, A. E. (2004) · Current Opinion in Endocrinology & Diabetes · doi:10.1097/01.med.0000129636.04145.84 · Cited by 35
Metadata
- Authors
- Goldberg, P. A., Siegel, M. D., Sherwin, R. S., Halickman, J. I., Lee, M., Bailey, V. A., Lee, S. L., Dziura, J. D., & Inzucchi, S. E.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2004-02-01
- Volume
- 27
- Issue
- 2
- Pages
- 461-467
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2107075639
- Cited by
- 483
- References
- 21
- FWCI
- 26.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.