Establishment of national diagnostic dose reference levels (DRLs) for routine computed tomography examinations in Jordan
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Background: Dose reference levels (DRLs) are used as indicators as well as guidance for dose optimization and to ensure justification of appropriate dose for a given clinical indication. The main aims of this study were to establish local DRLs for each CT imaging protocol as a reference point to evaluate the radiation dose indices and to compare our DRLs with those established in other countries and against the internationally reported guidelines. Materials and methods: 2000 CT dose reports of different adult imaging protocols from January 2021 until April 2022 were collected retrospectively at different hospitals in Jordan. Data were collected from CT scans that were performed using different types and models of CT scanners and included four adult non-enhanced, helical CT imaging protocols; Head, Chest, Abdomen-Pelvis, and Chest-Abdomen-Pelvis. Results: The average doses of CTDI vol , DLP, and effective dose were (65.11 mGy, 1232.71 mGy·cm, 2.83 mSv) for the head scan, (16.6 mGy, 586.6 mGy·cm, 8.21 mSv) for the chest scan, (17.91 mGy, 929.9 mGy·cm, 13.9 mSv) for the abdomen-pelvis scan, and (19.3 mGy, 1152 mGy·cm, 17.25 mSv) for the chest-abdomen-pelvis scan. In comparison with results from different international studies, DLP values measured in the present study were lower for the chest-abdomen-pelvis and abdomen-pelvis CT scans, and higher for the head CT and chest CT scans. Conclusions: It is very important that each country establishes its own DRLs and compares them with those reported by other countries, especially the developed ones. It is also important that these levels are regularly updated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A study conducted in 2023 by Radaideh et al assessed more than 2,000 CT scans from various hospitals in Jordan over the years 2021 and 2022.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [10]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Despite global progress in Diagnostic Reference Levels (DRLs), Jordan has failed to establish official national DRLs for routine CT imaging, resulting in a significant deficiency in dose optimization and quality assurance protocols.10”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [10]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The suggested diagnostic reference levels (DRLs) for adult head computed tomography (CT) are 65.1 mGy CTDIvol and 945 mGy·cm DLP, significantly exceeding the reference limits established in the UK.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [10]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The suggested DLP for chest-abdomen-pelvis CT was relatively lower.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [10]
The cited source says what the claim attributes to it.
In the citing paper
“The values were derived from the 75th percentile of the gathered data, in accordance with ICRP recommendations.10”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [10]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries
de González, A. B., & Darby, S. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15433-0 · Cited by 1,718
ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
Vañó, E., Miller, D. L., Martin, C. J., Rehani, M. M., Kang, K., Rosenstein, M., Ortiz-López, P., Mattsson, S., Padovani, R., & Rogers, A. (2017) · Annals of the ICRP · doi:10.1177/0146645317717209 · Cited by 1,043
AAPM/RSNA Physics Tutorial for Residents: Topics in CT: Radiation Dose in CT
McNitt-Gray, M. F. (2002) · RadioGraphics · doi:10.1148/rg.226025128 · Cited by 612 · cited 1×
“48 In comparison with results from different international studies, DLP values measured in the present study were lower for the chest abdomen-pelvis and abdomen-pelvis CT scans and higher for the head CT and chest CT scans.”
The Measurement, Reporting, and Management of Radiation Dose in CT
McCollough, C., Cody, D., Edyvean, S., Geise, R., Gould, B., Keat, N., Huda, W., Judy, P., Kalender, W., McNitt-Gray, M., et al. (2008) · doi:10.37206/97 · Cited by 569
U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations
Kanal, K. M., Butler, P. F., Sengupta, D., Bhargavan-Chatfield, M., Coombs, L. P., & Morin, R. L. (2017) · Radiology · doi:10.1148/radiol.2017161911 · Cited by 395
Rehani, M. M., Ciraj-Bjelac, O., Vañó, E., Miller, D. L., Walsh, S., Giordano, B. D., & Persliden, J. (2010) · Annals of the ICRP · doi:10.1016/j.icrp.2012.03.001 · Cited by 344
McCollough, C. H., Chen, G. H., Kalender, W., Leng, S., Samei, E., Taguchi, K., Wang, G., Yu, L., & Pettigrew, R. I. (2012) · Radiology · doi:10.1148/radiol.12112265 · Cited by 276
Establishment of CT diagnostic reference levels in Ireland
Foley, S. J., McEntee, M. F., & Rainford, L. A. (2012) · The British Journal of Radiology · doi:10.1259/bjr/15839549 · Cited by 186 · cited 3×
“…quartile for CTDIvol and the effective dose values ( Table 6 ) for the chest-abdomen-pelvis imaging protocol (19.3 mGy and 17.25 mSv, respectively) was lower than the 3 rd quartile measured in some previous studies 20,26 and higher than the 3 rd quartile measured in other studies 24,31,34,36,37 .”
InfluentialSchauer, D. A., & Linton, O. W. (2009) · Radiology · doi:10.1148/radiol.2532090494 · Cited by 171
Valentin, J. (2001) · Annals of the ICRP · doi:10.1016/s0146-6453(02)00007-6 · Cited by 149
Research works printed but not linked: 4
- 2. Rothenberg LN, Pentlow KS. CT dosimetry and radiation safety. In: Goldman LW, Fowlkes JB, eds. Medical CT and Ultrasound: Current Technology and Applications. Madison, Wis: Advanced Medical Publishing; 1995:519-553
- 4. IAEA Safety Standards Series No. GSR Part 3. Radiation protection and safety of radiation sources: International basic safety standards. General safety requirements Part 3 (Spanish Edition). 2016.
- 10. Shrimpton PC, Hillier MC, Lewis MA, Dunn M. NRPB-W67 doses from computed tomography (CT) examinations in the UK-2003 review. National Radiation Protection Board.2005.
- 45. Vilar-Palop J, Vilar J, Hernández-Aguado I, et al. Updated effective doses in radiology. Journal of Radiological Protection. 2016;36(4):975-990. https://doi.org/10.1088/0952-4746/36/4/975 · DOI
Cited by
A closer look at utilized radiation doses during chest CT for COVID-19 patients
Khallouqi, A., Sekkat, H., Halimi, A., & Rhazouani, O. E. (2024) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2024.112079 · Cited by 19
An Analysis of Computed Tomography Diagnostic Reference Levels in India Compared to Other Countries
Malik, M. M. U. D., Alqahtani, M. M., Hadadi, I., AlQhtani, A. G. M., & Alqarni, A. (2024) · Diagnostics · doi:10.3390/diagnostics14151585 · Cited by 17
Diagnostic Reference Levels of Radiographic and CT Examinations in Jordan: A Systematic Review
Alzyoud, K., Al-Murshedi, S., & England, A. (2024) · Health Physics · doi:10.1097/hp.0000000000001778 · Cited by 6
Botwe, B. O., Anim-Sampong, S., & Saizi, R. (2025) · International Journal of Biomedical Imaging · doi:10.1155/ijbi/6464273 · Cited by 4
Hamd, Z. Y., Almohammed, H. I., Manssor, E., Bakry, A. H. A., & Gareeballah, A. (2025) · Tomography · doi:10.3390/tomography11060065 · Cited by 3
Ito, T. (2025) · Journal of Radiation Protection and Research · doi:10.14407/jrpr.2024.00143 · Cited by 3
“DRL values for hybrid imaging CT used in nuclear medicine are shown in Tables 13 E C ( 2014 ) [ 47 ] U K ( 2019 ) [ 48 ] U SA ( 2016 ) [ 49 ] K o r ea ( 2021 ) [ 50 ] A u s t r a li a ( 2020 ) [ 51 ] E t h i o p i a ( 2022 ) [ 38 ] M o r o cc o ( 2021 ) [ 41 ] C T D I v o l D o s e r e f e r t o t…”
Proposing computed tomography diagnostic reference levels in Jordan: a national multicentre analysis
Yaseen, A.-B. B., Trapp, J., & Fontanarosa, D. (2025) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-025-01667-2 · Cited by 2
Khajmi, H., Mounir, A., Tounsi, A., & Lhouceine, O. (2025) · Radioprotection · doi:10.1051/radiopro/2024040 · Cited by 2
Al-Horani, Q., Alkhybari, E., Rawashdeh, M., Latiff, R. A., Sabarudin, A., Al-Ibraheem, A., & Mohamad, M. (2023) · Research Square · doi:10.21203/rs.3.rs-3049856/v1 · Cited by 1
Oglat, A., Shdaifat, S., Sayah, M., Abukonna, A., & Khogali, W. (2026) · Drug, Healthcare and Patient Safety · doi:10.2147/dhps.s595721
“9,10 The review aims to enhance radiation protection standards in Jordan and promote the advancement of safe imaging procedures by examining commonalities, discrepancies, and opportunities for improvement.”
Konaté, I., Anouan, K. J., Koua, A. A., & Bakayoko, V. S. (2024) · Open Journal of Applied Sciences · doi:10.4236/ojapps.2024.1412232
Python software for patient exposure analysis in radiology
Skrzyński, W., Pasicz, K., & Fabiszewska, E. (2024) · Polish Journal of Medical Physics And Engineering · doi:10.2478/pjmpe-2024-0034
Delvihardini, R., Pratama, I. B. G. P., Milvita, D., Oktavia, A., & Fardela, R. (2025) · Jurnal Pendidikan Fisika dan Teknologi · doi:10.29303/jpft.v11i1.8435
“The increasing use of X-rays in the medical field is accompanied by rapid advancement in technology and has significantly impacted both therapeutic and diagnostic radiology (Bibbo et al., 2016; Fardela et al., 2023, 2024; Muhammad et al., 2021; Oliveira Bernardo et al., 2023; Radaideh et al., 2023).”
Alhujaili, S. F., Alrowaili, Z. A., Alshabibi, A. S. A., Alafer, F., Alharbi, R. M., Almuzaini, N., Osman, H., Alselmi, B., Alyami, W. M., & Abuhaimed, A. (2025) · Journal of Radiation Research and Applied Sciences · doi:10.1016/j.jrras.2025.102089
Al-Saleh, W. M., Almatani, T., Rajappan, S. K., Qashqari, S. A., Alhuzali, M., Basudan, M. A., Abdullah, A. T. S., Alkhuzaee, H. A. H., & Sulieman, A. (2026) · The European Physical Journal Plus · doi:10.1140/epjp/s13360-026-07515-w
Evaluation and Risk Estimation of Adult Head CT in A Police Health Facility
Islamiyah, I., Gumelar, A., Santoso, M. I., Ahya, R. N., Hakikillah, A., Yueniwati, Y., & Widodo, C. S. (2026) · Nusantara Science and Technology Proceedings · doi:10.11594/nstp.2026.5428
“The total effective dose of this study was lower than the effective dose of Radaideh et al. (2023) and Matsunaga (2016) but higher than other countries according to Table 2.”
Ababneh, E., & Alfwares, A. A. (2026) · Health Research in Africa · doi:10.67260/hra.v4i10.7950
“…values (Table 3.b) for the head imaging protocol (73.36 mGy,1346.05 mGy · cm, 3.09 mSv, respectively) were lower than the 3rd quartile measured in some previous studies [1,10,18,27,28,32,40], and higher than the 3rd quartile measured in other studies [9,19 – 21, 23 – 25, 29 – 32, 35, 36,40 – 42”
InfluentialIMPLEMENTATION OF LOCAL DIAGNOSTIC REFRENCES LEVEL (DRL) ON CT-SCAN AT RSI YOGYAKARTA PDHI
Mas'uul, A. R., Kanayanaquita, & Handayani, N. (2025) · Jurnal Kesehatan · doi:10.24252/kesehatan.v18i1.45016
M. ALBastaki, Z. E., Embong, Z., ALMazrouei, N. K., Perez, J., & Zubair, S. (2025) · South Eastern European Journal of Public Health
ALBastaki, M. (2025) · Journal of Propulsion Technology
Yaseen, A.-B. B., Trapp, J., & Fontanarosa, D. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.113277
Metadata
- Authors
- Radaideh, K., Al-Radaideh, A., Ramli, R. M., Saleh, A., & Alshayeb, R.
- Affiliations
- Isra University (JO)
- Department of Medical Imaging , The Hashemite University , Jordan
- Universiti Sains Malaysia (MY)
- Corresponding author
- Radaideh, Khaldoon
- Venue
- Polish Journal of Medical Physics and Engineering
- Publisher
- Walter de Gruyter GmbH
- Published
- 2023-02-01
- Volume
- 29
- Issue
- 1
- Pages
- 26-34
- ISSN
- 1425-4689 (ISSN-L)
- 1898-0309
- OpenAlex
- W4318766078
- Semantic Scholar
- bc3579846d329d84b59397575f3aeecd58b5d526
- Cited by
- 16
- References
- 44
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 6 · 2023: 1
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- Locations
- Polish Journal of Medical Physics And Engineering (publishedVersion, cc-by-nc-nd)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
- Keywords
- dose reference levels, computed tomography, radiation dose, CTDIvol, dose-length product, effective dose, head CT, chest CT, abdomen-pelvis CT, dose optimization, Jordan
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.