Standards for PET Image Acquisition and Quantitative Data Analysis
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
Quantitative (18)F-FDG PET is increasingly being recognized as an important tool for diagnosis, determination of prognosis, and response monitoring in oncology. However, PET quantification with, for example, standardized uptake values (SUVs) is affected by many technical and physiologic factors. As a result, some of the variations in the literature on SUV-based patient outcomes are explained by differences in (18)F-FDG PET study methods. Various technical and clinical studies have been performed to understand the factors affecting PET quantification. On the basis of the results of those studies, several recommendations and guidelines have been proposed with the aims of improving the image quality and the quantitative accuracy of (18)F-FDG PET studies. In this contribution, an overview of recommendations and guidelines for quantitative (18)F-FDG PET studies in oncology is provided. Special attention is given to the rationale underlying certain recommendations and to some of the differences in various guidelines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1)
Eisenhauer, E. A., Therasse, P., Bogaerts, J., Schwartz, L. H., Sargent, D., Ford, R., Dancey, J., Arbuck, S., Gwyther, S., Mooney, M., et al. (2009) · European Journal of Cancer · doi:10.1016/j.ejca.2008.10.026 · Cited by 29,534 · cited 1×
“The main disadvantage of nonstandardized SUVs is that, although a proof of concept for various clinical applications has been demonstrated in several single-center studies, the results cannot be directly applied at other sites or in multicenter studies(45).Suchheterogeneitypartlyexplainswhyeventhe latestresponseevalua…”
BackgroundRevised Response Criteria for Malignant Lymphoma
Cheson, B. D., Pfistner, B., Juweid, M. E., Gascoyne, R. D., Specht, L., Horning, S. J., Coiffier, B., Fisher, R. I., Hagenbeek, A., Zucca, E., et al. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.09.2403 · Cited by 4,426
Young, H., Baum, R., Cremerius, U., Herholz, K., Hoekstra, O., Lammertsma, A. A., Pruim, J., & Price, P. (1999) · European Journal of Cancer · doi:10.1016/s0959-8049(99)00229-4 · Cited by 1,720
Partial-Volume Effect in PET Tumor Imaging
Soret, M., Bacharach, S. L., & Buvat, I. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.035774 · Cited by 1,549
Juweid, M. E., Stroobants, S., Hoekstra, O. S., Mottaghy, F. M., Dietlein, M., Guermazi, A., Wiseman, G. A., Kostakoglu, L., Scheidhauer, K., Buck, A., et al. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.08.2305 · Cited by 1,335
Recommendations on the Use of 18F-FDG PET in Oncology
Fletcher, J. W., Djulbegovic, B., Soares, H. P., Siegel, B. A., Lowe, V. J., Lyman, G. H., Coleman, R. E., Wahl, R., Paschold, J. C., Avril, N., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.047787 · Cited by 1,101
SUV: standard uptake or silly useless value?
Keyes, J. W. (1995) · PubMed · Cited by 803
Shankar, L. K., Hoffman, J. M., Bacharach, S. L., Graham, M. M., Karp, J. S., Lammertsma, A. A., Larson, S. M., Mankoff, D. A., Siegel, B. A., den Abbeele, A. V., et al. (2006) · PubMed · Cited by 765
(2004) · PubMed · Cited by 653
Procedure guideline for tumor imaging with F-18 FDG PET/CT
Delbeke, D., Coleman, R. E., Guiberteau, M. J., Brown, M. L., Royal, H. D., Siegel, B. A., Townsend, D. W., Berland, L. L., Parker, J. A., Hübner, K. F., et al. (2006) · Cited by 620
Cited by
3D Slicer as an image computing platform for the Quantitative Imaging Network
Fedorov, A., Beichel, R., Kalpathy-Cramer, J., Finet, J., Fillion-Robin, J.-C., Pujol, S., Bauer, C., Jennings, D., Fennessy, F., Sonka, M., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.05.001 · Cited by 9,023
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303
“This requires reconstruction settings to be chosen such as to achieve matching convergence and spatial resolution across various systems and sites, especially within a multicentre setting [48, 58, 59].”
InfluentialSelf-citationRadiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258
“PET–CT Quantitative imaging with 2-deoxy-2-[(18)F]fluoro-D-glucose (18-FDG) PET scans is a challenge because it not only requires calibration of the scanner and standardization of the scan protocol but also requires the patient and staff to adhere to a strict patient protocol [14,15].”
MethodBarrington, S. F., Mikhaeel, N. G., Kostakoglu, L., Meignan, M., Hutchings, M., Müeller, S. P., Schwartz, L. H., Zucca, E., Fisher, R. I., Trotman, J., et al. (2014) · Journal of Clinical Oncology · doi:10.1200/jco.2013.53.5229 · Cited by 1,665
FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0
Boellaard, R., O’Doherty, M. J., Weber, W. A., Mottaghy, F. M., Lonsdale, M. N., Stroobants, S. G., Oyen, W. J. G., Kotzerke, J., Hoekstra, O. S., Pruim, J., et al. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1297-4 · Cited by 1,326
Self-citationRadiomics: the facts and the challenges of image analysis
Rizzo, S., Botta, F., Raimondi, S., Origgi, D., Fanciullo, C., Morganti, A. G., & Bellomi, M. (2018) · European Radiology Experimental · doi:10.1186/s41747-018-0068-z · Cited by 1,054
Kinahan, P. E., & Fletcher, J. W. (2010) · Seminars in Ultrasound, CT and MRI · doi:10.1053/j.sult.2010.10.001 · Cited by 631
Machine and deep learning methods for radiomics
Avanzo, M., Wei, L., Stancanello, J., Vallières, M., Rao, A., Morin, O., Mattonen, S. A., & El Naqa, I. (2020) · Medical Physics · doi:10.1002/mp.13678 · Cited by 605
Cavo, M., Terpos, E., Nanni, C., Moreau, P., Lentzsch, S., Zweegman, S., Hillengass, J., Engelhardt, M., Usmani, S. Z., Vesole, D. H., et al. (2017) · The Lancet Oncology · doi:10.1016/s1470-2045(17)30189-4 · Cited by 544
Leijenaar, R. T. H., Nalbantov, G., Carvalho, S., van Elmpt, W. J. C., Troost, E. G. C., Boellaard, R., Aerts, H. J. W. L., Gillies, R. J., & Lambin, P. (2015) · Scientific Reports · doi:10.1038/srep11075 · Cited by 426
Self-citationA review on segmentation of positron emission tomography images
Foster, B., Bagci, U., Mansoor, A., Xu, Z., & Mollura, D. J. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.04.014 · Cited by 370
Zaidi, H., & El Naqa, I. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1423-3 · Cited by 366
Aide, N., Lasnon, C., Veit-Haibach, P., Sera, T., Sattler, B., & Boellaard, R. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3740-2 · Cited by 344
Self-citationFunctional expression of sodium-glucose transporters in cancer
Scafoglio, C., Hirayama, B. A., Kepe, V., Liu, J., Ghezzi, C., Satyamurthy, N., Moatamed, N. A., Huang, J., Koepsell, H., Barrio, J. R., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1511698112 · Cited by 329
Xiang, L., Qiao, Y., Nie, D., An, L., Lin, W., Wang, Q., & Shen, D. (2017) · Neurocomputing · doi:10.1016/j.neucom.2017.06.048 · Cited by 308
Zwanenburg, A. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04391-8 · Cited by 306
Osborne, M. T., Hulten, E. A., Singh, A., Waller, A. H., Bittencourt, M. S., Stewart, G. C., Hainer, J., Murthy, V. L., Skali, H., Dorbala, S., et al. (2014) · Journal of Nuclear Cardiology · doi:10.1007/s12350-013-9828-6 · Cited by 298
Assessing Tumor Response to Therapy
Weber, W. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057174 · Cited by 269
Imaging for Staging and Response Assessment in Lymphoma
Johnson, S. A., Kumar, A., Matasar, M. J., Schöder, H., & Rademaker, J. (2015) · Radiology · doi:10.1148/radiol.2015142088 · Cited by 185
EANM/EARL FDG-PET/CT accreditation - summary results from the first 200 accredited imaging systems
Kaalep, A., Sera, T., Oyen, W., Krause, B. J., Chiti, A., Liu, Y., & Boellaard, R. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3853-7 · Cited by 174
“In addition to various PET/CT models available, the acquisition and reconstruction parameters applied at different sites vary greatly due to local preferences [24, 32, 33].”
BackgroundSelf-citationFDG-PET imaging in mild traumatic brain injury: a critical review
Byrnes, K. R., Wilson, C. M., Brabazon, F., von Leden, R., Jurgens, J. S., Oakes, T. R., & Selwyn, R. G. (2014) · Frontiers in Neuroenergetics · doi:10.3389/fnene.2013.00013 · Cited by 171
“…blood GL, uptake period, patient motion, and sedation, and technological factors such as scan acquisition and image reconstruction parameters, ROI definition, scanner normalization, and calibration, and FDG administration (Keyes, 1995; Boellaard et al., 2004; Boellaard, 2009; Adams et al., 2010).”
BackgroundFeasibility of state of the art PET/CT systems performance harmonisation
Kaalep, A., Sera, T., Rijnsdorp, S., Yaqub, M., Talsma, A., Lodge, M. A., & Boellaard, R. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-3977-4 · Cited by 160
Self-citationSher, A., Lacoeuille, F., Fosse, P., Vervueren, L., Cahouet-Vannier, A., Dabli, D., Bouchet, F., & Couturier, O. (2016) · EJNMMI Research · doi:10.1186/s13550-016-0177-8 · Cited by 111
“5 versus R10) were observed for the same tumor in the same patient, which is obviously unacceptable for response-monitoring purposes, particularly when accumulated to other sources of bias [11, 21] and if a threshold value is applied to determine treatment response as with PERCIST criteria [3].”
Role of Optimal Quantification of FDG PET Imaging in the Clinical Practice of Radiology
Ziai, P., Hayeri, M. R., Salei, A., Salavati, A., Houshmand, S., Alavi, A., & Teytelboym, O. M. (2016) · RadioGraphics · doi:10.1148/rg.2016150102 · Cited by 106
Qualitative and Quantitative Comparison of PET/CT and PET/MR Imaging in Clinical Practice
Al-Nabhani, K. Z., Syed, R., Michopoulou, S., Alkalbani, J., Afaq, A., Panagiotidis, E., O’Meara, C., Groves, A., Ell, P., & Bomanji, J. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.123547 · Cited by 101
PET in the management of locally advanced and metastatic NSCLC
Grootjans, W., de Geus-Oei, L.-F., Troost, E. G. C., Visser, E. P., Oyen, W. J. G., & Bussink, J. (2015) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2015.75 · Cited by 97
Instrumentation factors affecting variance and bias of quantifying tracer uptake with PET/CT
Doot, R. K., Scheuermann, J. S., Christian, P. E., Karp, J. S., & Kinahan, P. E. (2010) · Medical Physics · doi:10.1118/1.3499298 · Cited by 82
Quantitative implications of the updated EARL 2019 PET–CT performance standards
Kaalep, A., Burggraaff, C. N., Pieplenbosch, S., Verwer, E. E., Sera, T., Zijlstra, J., Hoekstra, O. S., Oprea-Lager, D. E., & Boellaard, R. (2019) · EJNMMI Physics · doi:10.1186/s40658-019-0257-8 · Cited by 79
“However, SUV bias and increased variability can arise from multiple factors [9, 11] and need to”
BackgroundSelf-citationReduction of 18 F-FDG Dose in Clinical PET/MR Imaging by Using Silicon Photomultiplier Detectors
Sekine, T., Delso, G., Zeimpekis, K. G., de Galiza Barbosa, F., ter Voert, E. E. G. W., Huellner, M., & Veit-Haibach, P. (2018) · Radiology · doi:10.1148/radiol.2017162305 · Cited by 79
“In addition, several other factors (eg, uptake time, attenuation correction method) can affect the PET image quality and appearance in patient studies (23).”
BackgroundPositron emission tomography in multiple sclerosis - straight to the target
Bodini, B., Tonietto, M., Airas, L., & Stankoff, B. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-021-00537-1 · Cited by 74
Kramer, G. M., Frings, V., Hoetjes, N., Hoekstra, O. S., Smit, E. F., de Langen, A. J., & Boellaard, R. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.170225 · Cited by 65
Self-citationWhat parameters from 18F-FDG PET/CT are useful in evaluation of adrenal lesions?
Kunikowska, J., Matyskiel, R., Toutounchi, S., Grabowska-Derlatka, L., Koperski, Ł., & Królicki, L. (2014) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2844-1 · Cited by 58
“Due to advances in technology quantitative analysis with PET/CT has been recognized as providing an objective, more accurate, and less observer-dependent measure for characterizing adrenal tumours than visual assessment alone [6, 18, 19].”
BackgroundVanderhoek, M., Perlman, S. B., & Jeraj, R. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.113332 · Cited by 47
“These uncertainties plague PET imaging regardless of the specific radiotracer being imaged (37).”
BackgroundMethodShiono, S., Abiko, M., Okazaki, T., Chiba, M., Yabuki, H., & Sato, T. (2011) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2011.02.041 · Cited by 40
Houdu, B., Lasnon, C., Licaj, I., Thomas, G., Do, P., Guizard, A.-V., Desmonts, C., & Aide, N. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4151-8 · Cited by 37
PET/CT mediastinal and liver FDG uptake: Effects of biological and procedural factors
Malladi, A., Viner, M., Jackson, T., Mercier, G., & Subramaniam, R. M. (2013) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.12015 · Cited by 35
Otani, T., Hosono, M., Kanagaki, M., Onishi, Y., Matsubara, N., Kawabata, K., & Kimura, H. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.18.20478 · Cited by 33
Aschoff, P., Plathow, C., Beyer, T., Lichy, M. P., Erb, G., Öksüz, M. Ö., Claussen, C. D., & Pfannenberg, C. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1919-5 · Cited by 29
“The differences in SUVmean were below 10% and therefore in the range of a multitude of other factors influencing the SUV calculation like uptake time, plasma glucose level, the patient’s body composition, ROI definition, reconstruction methods, scanner characteristics and calibration of the PET/CT system [25].”
BackgroundMittal, B., Kuruva, M., Abrar, M., Kashyap, R., & Bhattacharya, A. (2012) · Indian Journal of Nuclear Medicine · doi:10.4103/0972-3919.108835 · Cited by 24
“Standardized uptake value (SUV), a semiquantitative parameter, most commonly employed in clinical practice is easy to be obtained but depends on various factors.[5] Determination of background SUV of liver and mediastinal blood pool is important as the response assessment criteria like PERCIST 1.”
Impacts of time interval on 18F-FDG uptake for PET/CT in normal organs: A systematic review
Wang, R., Chen, H., & Fan, C. (2018) · Medicine · doi:10.1097/md.0000000000013122 · Cited by 15
“In clinical practice, we evaluated the 18F-FDG images by qualitatively using visual comparison of the metabolism in lesions relative to normal tissues or semi-quantitatively by standardized uptake values.([2,3]) There are many factors such as weight, blood glucose level, and time interval affecting the SUV on normal o…”
MethodIntra-individual comparison of PET/CT with different body weight-adapted FDG dosage regimens
Geismar, J. H., Stolzmann, P., Sah, B.-R., Burger, I. A., Seifert, B., Delso, G., von Schulthess, G. K., Veit-Haibach, P., & Husmann, L. (2015) · Acta Radiologica Open · doi:10.1177/2047981614560076 · Cited by 15
Pilz, J., Hehenwarter, L., Zimmermann, G., Rendl, G., Schweighofer-Zwink, G., Beheshti, M., & Pirich, C. (2021) · EJNMMI Research · doi:10.1186/s13550-021-00784-9 · Cited by 6
Metadata
- Authors
- Boellaard, R.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2009-04-20
- Volume
- 50
- Issue
- Suppl 1
- Pages
- 11S-20S
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2143967388
- Cited by
- 902
- References
- 62
- FWCI
- 31.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.