CoChat

18F-Fluorobenzyl Triphenyl Phosphonium: A Noninvasive Sensor of Brown Adipose Tissue Thermogenesis

Open access
Madar, Igal, Isoda, Takuro, Finley, Paige, Angle, James, Wahl, Richard · 2011 · Journal of Nuclear Medicine
Cited by 42

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

UNLABELLED: Recent studies have proposed activation of brown adipose tissue (BAT) thermogenesis as a new strategy to combat obesity. Currently, there is no effective noninvasive imaging agent to directly detect unstimulated BAT and quantify the core mechanism of mitochondrial thermogenesis. We investigated an approach to detect BAT depots and monitor thermogenesis using the mitochondria-targeting voltage sensor radiolabeled fluorobenzyltriphenyl phosphonium (FBnTP). METHODS: (18)F-FBnTP, (14)C-FBnTP, (18)F-FDG, and (99m)Tc-sestamibi uptake in BAT at room temperature (n = 8) and cold-treated (n = 8) Lewis rats was assayed. The effect of the cold condition on (18)F-FBnTP retention in BAT was assessed in 8 treated and 16 control rats. The effect of the noradrenergic inhibitor propranolol on (14)C-FBnTP response to cold stimulation was investigated in an additional 8 treated and 8 control mice. RESULTS: At room temperature, (18)F-FBnTP accumulated in BAT to an extent similar to that in the heart, second only to the kidney and twice as much as (99m)Tc-sestamibi. Prior exposure to cold (4°C) for 4 h resulted in an 82% decrease of (14)C-FBnTP uptake and an 813% increase of (18)F-FDG uptake in BAT. (99m)Tc-sestamibi uptake was not affected by cold. Administration of (18)F-FBnTP at room temperature 60 min before 120 and 240 min of exposure to cold resulted in marked washout of the tracer from BAT. Propranolol significantly diminished the effect of cold on (14)C-FBnTP and (18)F-FDG uptake into BAT. CONCLUSION: The intense uptake of (18)F-FBnTP into BAT at room temperature and the response to cold stimulation suggest the unique potential advantage of (18)F-FBnTP not only in detecting unstimulated BAT at high contrast but also in quantifying the mitochondrial thermogenic activity. (18)F-FBnTP PET may serve as a useful technique to assess BAT volume and function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.110.084657

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 42

Metadata

Authors
Madar, I., Isoda, T., Finley, P., Angle, J., & Wahl, R.
Venue
Journal of Nuclear Medicine
Published
2011-04-15
Volume
52
Issue
5
Pages
808-814
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2099898216
Cited by
42
References
14
FWCI
1.35
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.