Quantitation of γ-trace in human biological fluids: Indications for production in the central nervous system
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Gamma-Trace was purified in large amounts from urine and used for the production of a specific rabbit antiserum. An enzyme immunoassay for quantitation of gamma-trace was developed using the pure protein as a primary standard. Its sensitivity was approximately 30 microgram/l. An enzyme amplified single radial immunodiffusion was developed as well. Its sensitivity was approximately 0.3 mg/l. These assays allowed quantitation of gamma-trace in normal human biological fluids. The following results were obtained (mean +/- SD): cerebrospinal fluid: 5.8 +/- 2.2 mg/l, plasma: 1.1 +/- 0.42 mg/l, saliva: 1.8 +/- 0.88 mg/l and urine: 0.095 +/- 0.057 mg/l. Plasma samples from patients with advanced renal failure revealed gamma-trace values up to 13 times the normal mean plasma value. The results indicate a production of gamma-trace in the central nervous system and that the protein is primarily catabolized by the kidney.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4
LAEMMLI, U. K. (1970) · Nature · doi:10.1038/227680a0 · Cited by 249,961
Immunochemical quantitation of antigens by single radial immunodiffusion
Mancini, G., Carbonara, A. O., & Heremans, J. F. (1965) · Immunochemistry · doi:10.1016/0019-2791(65)90004-2 · Cited by 9,139
Une micro-méthode de l’immuno-électrophorèse
Scheidegger, J. J. (1955) · International Archives of Allergy and Immunology · doi:10.1159/000228215 · Cited by 3,809
Coupling of enzymes to proteins with glutaraldehyde
Avrameas, S. (1969) · Immunochemistry · doi:10.1016/0019-2791(69)90177-3 · Cited by 1,441
The occurrence of post-gamma protein in urine: a new protein abnormality
Butler, E. A., & Flynn, F. V. (1961) · Journal of Clinical Pathology · doi:10.1136/jcp.14.2.172 · Cited by 117
A heated biuret-Folin protein assay which gives equal absorbance with different proteins
Dorsey, T. E., McDonald, P., & Roels, O. A. (1977) · Analytical Biochemistry · doi:10.1016/0003-2697(77)90019-7 · Cited by 105
IMMUNOCHEMICAL EVIDENCE FOR A GAMMA GLOBULIN PECULIAR TO CEREBROSPINAL FLUID
Macpherson, C. F., & Cosgrove, J. B. R. (1961) · Canadian Journal of Biochemistry and Physiology · doi:10.1139/o61-170 · Cited by 73
Hochwald, G. M., Pepe, A. J., & Thorbecke, G. J. (1967) · Experimental Biology and Medicine · doi:10.3181/00379727-124-31897 · Cited by 53
PURIFICATION OF THE GAMMA GLOBULIN CHARACTERISTIC OF CEREBROSPINAL FLUID
Macpherson, C. F. (1962) · Canadian Journal of Biochemistry and Physiology · doi:10.1139/y62-198 · Cited by 21
Macpherson, C. F. (1965) · Clinica Chimica Acta · doi:10.1016/0009-8981(65)90220-2 · Cited by 17
Cited by
Cystatin C as a marker of GFR—history, indications, and future research
Filler, G., Bökenkamp, A., Hofmann, W., Le Bricon, T., Martínez-Brú, C., & Grubb, A. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.09.025 · Cited by 734
Self-citationCystatin C: An Improved Estimator of Glomerular Filtration Rate?
Laterza, O. F., Price, C. P., & Scott, M. G. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.699 · Cited by 658
Kyhse-Andersen, J., Schmidt, C., Nordin, G., Andersson, B., Nilsson-Ehle, P., Lindström, V, & Grubb, A. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.10.1921 · Cited by 511
Self-citationAbrahamson, M., Barrett, A. J., Salvesen, G., & Grubb, A. (1986) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)67380-6 · Cited by 504
Self-citationGrubb, A., Nyman, U., Björk, J., Lindström, V., Rippe, B., Sterner, G., & Christensson, A. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.051557 · Cited by 459
Self-citationRenal handling of radiolabelled human cystatin C in the rat
Tenstad, O., Roald, A. B., Grubb, A., & Aukland, K. (1996) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519609088795 · Cited by 456
Self-citationCystatin C-Properties and use as diagnostic marker
(2001) · Advances in Clinical Chemistry · doi:10.1016/s0065-2423(01)35015-1 · Cited by 418
The blood serum concentration of cystatin C (γ-trace) as a measure of the glomerular filtration rate
Simonsen, O., Grubb, A., & Thysell, H. (1985) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365518509160980 · Cited by 337
Self-citationSerum Cystatin C as an Endogenous Marker of the Renal Function – a Review
Randers, E., & Erlandsen, E. J. (1999) · cclm · doi:10.1515/cclm.1999.064 · Cited by 334
Human gamma-trace, a basic microprotein: amino acid sequence and presence in the adenohypophysis.
Grubb, A., & Löfberg, H. (1982) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.79.9.3024 · Cited by 327
Self-citationGrubb, A., Horio, M., Hansson, L.-O., Björk, J., Nyman, U., Flodin, M., Larsson, A., Bökenkamp, A., Yasuda, Y., Blufpand, H., et al. (2014) · Clinical Chemistry · doi:10.1373/clinchem.2013.220707 · Cited by 324
Self-citationFinney, H., Newman, D. J., Gruber, W., Merle, P., & Price, C. P. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.6.1016 · Cited by 318
Biochemistry and Clinical Role of Human Cystatin C
Mussap, M., & Plebani, M. (2004) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408360490504934 · Cited by 313
FGF-2-Responsive Neural Stem Cell Proliferation Requires CCg, a Novel Autocrine/Paracrine Cofactor
Taupin, P., Ray, J., Fischer, W. H., Suhr, S. T., Hakansson, K., Grubb, A., & Gage, F. H. (2000) · Neuron · doi:10.1016/s0896-6273(00)00119-7 · Cited by 313
Self-citationGRUBB, A., SIMONSEN, O., STURFELT, G., TRUEDSSON, L., & THYSELL, H. (1985) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1985.tb08880.x · Cited by 303
Self-citationThe place of human γ-trace (cystatin C) amongst the cysteine proteinase inhibitors
Barrett, A. J., Davies, M. E., & Grubb, A. (1984) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(84)91302-0 · Cited by 294
Self-citationAdult Reference Ranges for Serum Cystatin C, Creatinine and Predicted Creatinine Clearance
Finney, H., Newman, D. J., & Price, C. P. (2000) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456320003700101 · Cited by 287
Evaluation of the Dade Behring N Latex Cystatin C assay on the Dade Behring Nephelometer II System
Erlandsen, E. J., Randers, E., & Kristensen, J. H. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185940 · Cited by 258
Urinary cystatin C as a specific marker of tubular dysfunction
Conti, M., Moutereau, S., Zater, M., Lallali, K., Durrbach, A., Manivet, P., Eschwège, P., & Loric, S. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.050 · Cited by 208
“18 mg/L, close to the values reported by Lofberg and Grubb, who developed the first CST3 assay (21), and by Uchida and Gotoh (16).”
ResultCystatin C: current position and future prospects
Séronie-Vivien, S., Delanaye, P., Piéroni, L., Mariat, C., Froissart, M., & Cristol, J.-P. (2008) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2008.336 · Cited by 205
“than in plasma, explaining why it was initially discovered in CSF (7).”
BackgroundInfluentialThyroxine transport in choroid plexus.
Dickson, P. W., Aldred, A. R., Menting, J. G., Marley, P. D., Sawyer, W. H., & Schreiber, G. (1987) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)47880-5 · Cited by 175
(2015) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2014.11.007 · Cited by 173
Determination of Serum Cystatin C: Biological Variation and Reference Values
Galteau, M.-M., Guyon, M., Gueguen, R., & Siest, G. (2001) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2001.141 · Cited by 159
“(1) mean±standard deviation; (2) reference interval [95%]; (3) median; (4) range; abbreviations: d, days; m, month; y, year”
BackgroundHuh, C. G., Håkansson, K., Nathanson, C. M., Thorgeirsson, U. P., Jonsson, N., Grubb, A., Abrahamson, M., & Karlsson, S. (1999) · Molecular Pathology · doi:10.1136/mp.52.6.332 · Cited by 119
Self-citation
Metadata
- Authors
- Löfberg, H., & Grubb, A. O.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1979-01
- Volume
- 39
- Issue
- 7
- Pages
- 619-626
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W1981832221
- Cited by
- 205
- References
- 10
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.