A review of technological and clinical aspects of robot-aided rehabilitation of upper-extremity after stroke
The DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Abstract
Cerebrovascular accident (CVA) or stroke is one of the leading causes of disability and loss of motor function. Millions of people around the world are effected by it each year. Stroke results in disabled arm function. Restoration of arm function is essential to regaining activities of daily living (ADL). Along with traditional rehabilitation methods, robot-aided therapy has emerged in recent years. Robot-aided rehabilitation is more intensive, of longer duration and more repetitive. Using robots, repetitive dull exercises can turn into a more challenging and motivating tasks such as games. Besides, robots can provide a quantitative measure of the rehabilitation progress. This article overviews the terms used in robot-aided upper-limb rehabilitation. It continues by investigating the requirements for rehabilitation robots. Then the most outstanding works in robot-aided upper-limb rehabilitation and their control schemes have been investigated. The clinical outcomes of the built robots are also given that demonstrates the usability of these robots in real-life applications and their acceptance. This article summarizes a review done along with a research on the design, simulation and control of a robot for use in upper-limb rehabilitation after stroke. Implications for Rehabilitation Reviewing common terms in rehabilitation of upper limb using robots Reviewing rehabilitation robots built up to date Reviewing clinical outcomes of the mentioned rehabilitation robots.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Biomechanics and Motor Control of Human Movement
Winter, D. A. (2009) · Wiley eBooks · doi:10.1002/9780470549148 · Cited by 6,066 · cited 1×
“Table 2 [24,40] gives these anthropometric data.”
Heart Disease and Stroke Statistics—2010 Update: A Report From the American Heart Association
WRITING GROUP MEMBERS, Lloyd-Jones, D., Adams, R. J., Brown, T. M., Carnethon, M., Dai, S., De Simone, G., Ferguson, T. B., Ford, E., Furie, K., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192667 · Cited by 5,700
Introduction to Robotics mechanics and Control
Craig, J. (1986) · Cited by 5,024
Robotics: modelling, planning and control
(2009) · Choice Reviews Online · doi:10.5860/choice.46-6226 · Cited by 2,479
Effects of Robot-Assisted Therapy on Upper Limb Recovery After Stroke: A Systematic Review
Kwakkel, G., Kollen, B. J., & Krebs, H. I. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307305457 · Cited by 1,503 · cited 1×
“Scale (assessment tools used to measure impairment and disability in those with neurological impairments) [21].”
MethodRobot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425 · cited 11×
“Active-resisted movement mode, in which the patient initiates the movement and is resisted by robotic device to challenge patient’s movement, is implemented in MIT-MANUS, Bi-Manu-Track and MIME.”
BackgroundInfluentialRobot-Assisted Therapy for Long-Term Upper-Limb Impairment after Stroke
Lo, A. C., Guarino, P. D., Richards, L. G., Haselkorn, J. K., Wittenberg, G. F., Federman, D. G., Ringer, R. J., Wagner, T. H., Krebs, H. I., Volpe, B. T., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0911341 · Cited by 1,397 · cited 1×
“months follow-up showed considerable results in comparison to usual and not intensive therapy [51].”
ResultReview of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Taub, E., Uswatte, G., & Pidikiti, R. D. (1999) · PubMed · Cited by 1,168
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159 · cited 3×
“In two RCTs, it was shown that MIME can improve impairment and muscle activation in sub-acute and chronic stroke patients [52,53].”
BackgroundResultRecovery of upper extremity function in stroke patients: The Copenhagen stroke study
Nakayama, H., Stig Jørgensen, H., Otto Raaschou, H., & Skyhøj Olsen, T. (1994) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(94)90161-9 · Cited by 1,056 · cited 1×
“[5], only 18% of stroke survivors regain full motor function after 6 months.”
BackgroundPrange, G. B., Jannink, M. J. A., Groothuis-Oudshoorn, C. G. M., Hermens, H. J., & IJzerman, M. J. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.04.0076 · Cited by 917 · cited 9×
“MIME can be classified into end-effector-based robots.”
MethodInfluentialWOLF, S., LECRAW, D., BARTON, L., & JANN, B. (1989) · Experimental Neurology · doi:10.1016/s0014-4886(89)80005-6 · Cited by 901 · cited 1×
“of the affected arm in the real-world environment [16–19].”
BackgroundBütefisch, C., Hummelsheim, H., Denzler, P., & Mauritz, K.-H. (1995) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(95)00003-k · Cited by 840 · cited 1×
“successful training are training intensity [9–11], duration [12,13] and repetition [14].”
BackgroundDevelopment of robots for rehabilitation therapy: the Palo Alto VA/Stanford experience.
Burgar, C. G., Lum, P. S., Shor, P. C., & der Loos, H. F. M. V. (2000) · PubMed · Cited by 800
Strategies for stroke rehabilitation
Dobkin, B. H. (2004) · The Lancet Neurology · doi:10.1016/s1474-4422(04)00851-8 · Cited by 738 · cited 1×
“ADL training in robotic devices is that according to literature [8,15], functional and task-oriented training shows good results in stroke patients.”
BackgroundMiltner, W. H. R., Bauder, H., Sommer, M., Dettmers, C., & Taub, E. (1999) · Stroke · doi:10.1161/01.str.30.3.586 · Cited by 591
Effects of Intensity of Rehabilitation After Stroke: A Research Synthesis
Kwakkel, G., Wagenaar, R. C., Koelman, T. W., Lankhorst, G. J., & Koetsier, J. C. (1997) · Stroke · doi:10.1161/01.str.28.8.1550 · Cited by 589 · cited 1×
“successful training are training intensity [9–11], duration [12,13] and repetition [14].”
BackgroundReinkensmeyer, D. J., Kahn, L. E., Averbuch, M., McKenna-Cole, A. N., Schmit, B. D., & Rymer, W. Z. (2000) · PubMed · Cited by 558
The Mass and Inertia Characteristics of the Main Segments of the Human Body
Zatsiorsky, V. M. (1983) · Biomechanics · Cited by 555
Robot-Aided Neurorehabilitation: A Robot for Wrist Rehabilitation
Krebs, H. I., Volpe, B. T., Williams, D., Celestino, J., Charles, S. K., Lynch, D., & Hogan, N. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903899 · Cited by 553 · cited 2×
“In the second class, the focus of training is on distal parts of the human arm such as hand [27], the wrist and the lower arm [28,29].”
BackgroundMethodStroke Incidence, Case Fatality, and Mortality in the WHO MONICA Project
Thorvaldsen, P., Asplund, K., Kuulasmaa, K., Rajakangas, A.-M., & Schroll, M. (1995) · Stroke · doi:10.1161/01.str.26.3.361 · Cited by 538
ARMin III – Arm Therapy Exoskeleton with an Ergonomic Shoulder Actuation
Nef, T., Guidali, M., & Riener, R. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902840179 · Cited by 522 · cited 1×
“ARMin III [73–76] is a further improved version of ARMin II in the case of robustness, complexity, user operation and reliability.”
BackgroundWearable Robots: Biomechatronic Exoskeletons
Pons, J. L. (2008) · Cited by 520
Wearable Robots: Biomechatronic Exoskeletons
(2008) · Wiley eBooks · doi:10.1002/9780470987667 · Cited by 517
Effects of robotic therapy on motor impairment and recovery in chronic stroke
Fasoli, S. E., Krebs, H. I., Stein, J., Frontera, W. R., & Hogan, N. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2003.50110 · Cited by 512 · cited 1×
“The three-DOF wrist module [29] was introduced to MIT-MANUS after its successful clinical results in rehabilitation of elbow and shoulder [43].”
MethodHesse, S., Schulte-Tigges, G., Konrad, M., Bardeleben, A., & Werner, C. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(02)04954-7 · Cited by 489 · cited 26×
“The reason for incorporating ADL training in robotic devices is that according to literature [8,15], functional and task-oriented training shows good results in stroke patients.”
BackgroundInfluentialLum, P. S., Burgar, C. G., Loos, M. V. D., Shor, P. C., Majmundar, M., & Yap, R. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.02.0044 · Cited by 461 · cited 4×
“In two RCTs, it was shown that MIME can improve impairment and muscle activation in sub-acute and chronic stroke patients [52,53].”
BackgroundInfluentialRehabilitation robotics: pilot trial of a spatial extension for MIT-Manus
Krebs, H. I., Ferraro, M., Buerger, S. P., Newbery, M. J., Makiyama, A., Sandmann, M., Lynch, D., Volpe, B. T., & Hogan, N. (2004) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-1-5 · Cited by 445 · cited 12×
“Active-resisted movement mode, in which the patient initiates the movement and is resisted by robotic device to challenge patient’s movement, is implemented in MIT-MANUS, Bi-Manu-Track and MIME.”
BackgroundInfluentialARMin: a robot for patient-cooperative arm therapy
Nef, T., Mihelj, M., & Riener, R. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0226-6 · Cited by 445 · cited 2×
“Figure 9 [left (down)] [68] depicts ARMin I robot.”
BackgroundMethodPost-stroke plastic reorganisation in the adult brain
Rossini, P. M., Calautti, C., Pauri, F., & Baron, J.-C. (2003) · The Lancet Neurology · doi:10.1016/s1474-4422(03)00485-x · Cited by 442 · cited 3×
“(M IM E ) [5 2 – 5 4 ] 6 (6 ac ti v e an d”
The Role of Task-Specific Training in Rehabilitation Therapies
Bayona, N. A., Bitensky, J., Salter, K., & Teasell, R. (2005) · Topics in Stroke Rehabilitation · doi:10.1310/bqm5-6ygb-mvj5-wvcr · Cited by 411
Robot-aided neurorehabilitation of the upper extremities
Riener, R., Nef, T., & Colombo, G. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345116 · Cited by 407 · cited 1×
“The robot must be capable of generating sufficient force to move a patient’s limb, it must also be easily movable by an elderly or impaired patient [25,37].”
BackgroundDromerick, A. W., Edwards, D. F., & Hahn, M. (2000) · Stroke · doi:10.1161/01.str.31.12.2984 · Cited by 400
Upper Limb Robot Mediated Stroke Therapy—GENTLE/s Approach
Loureiro, R., Amirabdollahian, F., Topping, M., Driessen, B., & Harwin, W. (2003) · Autonomous Robots · doi:10.1023/a:1024436732030 · Cited by 388 · cited 3×
“MIME system [53] (left), Inmotion2 (the commercial version of MIT-MANUS) [37]) [right (up)] and GENTLE/s system [55] [right (down)].”
MethodTreatment Interventions for the Paretic Upper Limb of Stroke Survivors: A Critical Review
Barreca, S., Wolf, S. L., Fasoli, S., & Bohannon, R. (2003) · Neurorehabilitation and Neural Repair · doi:10.1177/0888439003259415 · Cited by 378 · cited 5×
“According to literature [6–8], sensorimotor arm therapy has positive effects on the rehabilitation progress of stroke patients.”
BackgroundInfluentialKahn, L. E., Zygman, M. L., Rymer, W. Z., & Reinkensmeyer, D. J. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-12 · Cited by 375
Housman, S. J., Scott, K. M., & Reinkensmeyer, D. J. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308331148 · Cited by 369 · cited 3×
“Some studies showed effectiveness of robotic devices in comparison to usual or intensive therapy techniques [36,52,86,87].”
BackgroundResultSanchez, R. J., Liu, J., Rao, S., Shah, P., Smith, R., Rahman, T., Cramer, S. C., Bobrow, J. E., & Reinkensmeyer, D. J. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.881553 · Cited by 357 · cited 18×
“T-WREX system [64] [left (up)], MGA-exoskeleton [26] [left (down)], L-EXOS system [67] [right (up)], L-EXOS mechanical structure [67] [right (down)].”
BackgroundInfluentialThe Results of Clinical Trials in Stroke Rehabilitation Research
Ottenbacher, K. J., & Jannell, S. (1993) · Archives of Neurology · doi:10.1001/archneur.1993.00540010033014 · Cited by 351 · cited 1×
“successful training are training intensity [9–11], duration [12,13] and repetition [14].”
BackgroundBhattacharya, D., Aldus, C. F., Barton, G., Bond, C. M., Boonyaprapa, S., Charles, I. S., Fleetcroft, R., Holland, R., Jerosch‐Herold, C., Salter, C., et al. (2016) · Cited by 339
Sunderland, A., Tinson, D. J., Bradley, E. L., Fletcher, D., Langton Hewer, R., & Wade, D. T. (1992) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.55.7.530 · Cited by 332 · cited 1×
“successful training are training intensity [9–11], duration [12,13] and repetition [14].”
BackgroundHesse, S., Werner, C., Pohl, M., Rueckriem, S., Mehrholz, J., & Lingnau, M. L. (2005) · Stroke · doi:10.1161/01.str.0000177865.37334.ce · Cited by 331 · cited 2×
“[30], the distal approach results in a more powerful activation of the sensorimotor cortex.”
BackgroundAbnormal joint torque patterns in the paretic upper limb of subjects with hemiparesis
Dewald, J. P. A., & Beer, R. F. (2001) · Muscle & Nerve · doi:10.1002/1097-4598(200102)24:2<273::aid-mus130>3.0.co;2-z · Cited by 324 · cited 1×
“ARMin III can give a quantitative measure of some parameters such as active and passive ROM, muscle strength, abnormal joint synergies [79] and spatial precision of hand positioning.”
BackgroundBiofeedback for robotic gait rehabilitation
Lünenburger, L., Colombo, G., & Riener, R. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-1 · Cited by 297
Long term effects of intensity of upper and lower limb training after stroke: a randomised trial.
Kwakkel, G., Kollen, B. J., & WAGENAAR, R. C. (2002) · PubMed · doi:10.1136/jnnp.72.4.473 · Cited by 283 · cited 1×
“successful training are training intensity [9–11], duration [12,13] and repetition [14].”
BackgroundChanging Motor Synergies in Chronic Stroke
Dipietro, L., Krebs, H. I., Fasoli, S. E., Volpe, B. T., Stein, J., Bever, C., & Hogan, N. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01295.2006 · Cited by 263 · cited 1×
“On the other hand, no considerable increase in functional performance is statistically shown [43–48].”
BackgroundVolpe, B. T., Lynch, D., Rykman-Berland, A., Ferraro, M., Galgano, M., Hogan, N., & Krebs, H. I. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307311102 · Cited by 256 · cited 1×
“Rehabilitation using MIT-MANUS showed considerable increase in comparison to Group therapy and intensive traditional therapy [49,50].”
ResultImproving Hand Function in Chronic Stroke
Muellbacher, W., Richards, C., Ziemann, U., Wittenberg, G., Weltz, D., Boroojerdi, B., Cohen, L., & Hallett, M. (2002) · Archives of Neurology · doi:10.1001/archneur.59.8.1278 · Cited by 253 · cited 1×
“The recently suggested competition between proximal and distal arm segments for plastic brain territory after stroke suggests shifting treatment emphasis from the shoulder to the forearm, hand and fingers [31].”
BackgroundRobot-aided sensorimotor arm training improves outcome in patients with chronic stroke
Ferraro, M., Palazzolo, J. J., Krol, J., Krebs, H. I., Hogan, N., & Volpe, B. T. (2003) · Neurology · doi:10.1212/01.wnl.0000095963.00970.68 · Cited by 242 · cited 1×
“On the other hand, no considerable increase in functional performance is statistically shown [43–48].”
BackgroundRobotic therapy for chronic motor impairments after stroke: follow-up results
Fasoli, S. E., Krebs, H. I., Stein, J., Frontera, W. R., Hughes, R., & Hogan, N. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.11.028 · Cited by 239 · cited 1×
“On the other hand, no considerable increase in functional performance is statistically shown [43–48].”
BackgroundLum, P., Reinkensmeyer, D., Mahoney, R., Rymer, W. Z., & Burgar, C. (2002) · Topics in Stroke Rehabilitation · doi:10.1310/9kfm-kf81-p9a4-5ww0 · Cited by 218 · cited 1×
“Clinicians will accept rehabilitation devices when they prove their efficacy in rehabilitation more than conventional techniques [84].”
BackgroundARMin II - 7 DoF rehabilitation robot: mechanics and kinematics
Mihelj, M., Nef, T., & Riener, R. (2007) · Proceedings 2007 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2007.364112 · Cited by 215 · cited 4×
“Figure 9 [right (up)] [71] depicts the ARMin II setup.”
BackgroundMethodInfluentialA Haptic Knob for Rehabilitation of Hand Function
Lambercy, O., Dovat, L., Gassert, R., Burdet, E., Teo, C. L., & Milner, T. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903913 · Cited by 196 · cited 1×
“In the second class, the focus of training is on distal parts of the human arm such as hand [27], the wrist and the lower arm [28,29].”
BackgroundARMin - Exoskeleton for Arm Therapy in Stroke Patients
Nef, T., Mihelj, M., Kiefer, G., Perndl, C., Muller, R., & Riener, R. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428408 · Cited by 192 · cited 2×
“(Left) (a) Armeo Power, (b) Armeo Spring and (c) Armeo Boom [23] and Teach-and-repeat trajectories for passive mobilization (right) [74].”
BackgroundMethodArm rehabilitation with a robotic exoskeleleton in Virtual Reality
Frisoli, A., Borelli, L., Montagner, A., Marcheschi, S., Procopio, C., Salsedo, F., Bergamasco, M., Carboncini, M. C., Tolaini, M., & Rossi, B. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428491 · Cited by 182 · cited 10×
“T-WREX system [64] [left (up)], MGA-exoskeleton [26] [left (down)], L-EXOS system [67] [right (up)], L-EXOS mechanical structure [67] [right (down)].”
BackgroundMethodInfluentialStaubli, P., Nef, T., Klamroth-Marganska, V., & Riener, R. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-46 · Cited by 181
A robotic system to train activities of daily living in a virtual environment
Guidali, M., Duschau-Wicke, A., Broggi, S., Klamroth-Marganska, V., Nef, T., & Riener, R. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0809-0 · Cited by 181 · cited 1×
“ARMin III [73–76] is a further improved version of ARMin II in the case of robustness, complexity, user operation and reliability.”
BackgroundARMin - Design of a Novel Arm Rehabilitation Robot
Nef, T., & Riener, R. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501051 · Cited by 180 · cited 1×
“Armin I [68–70] was designed and tested from 2003 to 2006.”
MethodResponse to upper-limb robotics and functional neuromuscular
Daly, J. J., Hogan, N., Perepezko, E. M., Krebs, H. I., Rogers, J. M., Goyal, K. S., Dohring, M. E., Fredrickson, E., Nethery, J., & Ruff, R. L. (2005) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.02.0048 · Cited by 179 · cited 1×
“On the other hand, no considerable increase in functional performance is statistically shown [43–48].”
BackgroundARMin - robot for rehabilitation of the upper extremities
Nef, T., Mihelj, M., Colombo, G., & Riener, R. (2006) · Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006. · doi:10.1109/robot.2006.1642181 · Cited by 179 · cited 1×
“Armin I [68–70] was designed and tested from 2003 to 2006.”
MethodDesign of an arm exoskeleton with scapula motion for shoulder rehabilitation
Roderick, S., Liszka, M., & Carignan, C. (2005) · ICAR '05. Proceedings., 12th International Conference on Advanced Robotics, 2005. · doi:10.1109/icar.2005.1507459 · Cited by 178 · cited 6×
“T-WREX system [64] [left (up)], MGA-exoskeleton [26] [left (down)], L-EXOS system [67] [right (up)], L-EXOS mechanical structure [67] [right (down)].”
BackgroundMethodInfluentialAcute neurological stroke care in Europe: results of the European Stroke Care Inventory
Brainin, M., Bornstein, N. M., Boysen, G., & Demarin, V. (2000) · European Journal of Neurology · doi:10.1046/j.1468-1331.2000.007001005.x · Cited by 160 · cited 1×
“It affects more than one million people in European Union each year [1,2].”
BackgroundArm-Training with T-WREX After Chronic Stroke: Preliminary Results of a Randomized Controlled Trial
Housman, S. J., Le, V., Rahman, T., Sanchez, R. J., & Reinkensmeyer, D. J. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428481 · Cited by 158 · cited 1×
“Although the group using T-WREX was superior in terms of arm movement mobility, this group was not significantly higher than the control group [65].”
ResultGuidance-based quantification of arm impairment following brain injury: a pilot study
Reinkensmeyer, D. J., Dewald, J. P. A., & Rymer, W. Z. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.750543 · Cited by 149 · cited 1×
“workplace deficits, although it is unable to accurately measure the constraint forces induced by mismatching between ARM guide geometry and usual reaching movement [59].”
BackgroundThe effect of the GENTLE/s robot-mediated therapy system on arm function after stroke
Coote, S. B., Murphy, T. B., Harwin, W., & Stokes, E. (2008) · Clinical Rehabilitation · doi:10.1177/0269215507085060 · Cited by 141 · cited 3×
“This study proved that patients who used the robotic system had higher improvement rate in robotic rehabilitation phase than arm in a sling phase or baseline phase [56].”
BackgroundInfluentialDevices for assisting manipulation: a summary of user task priorities
Stanger, C. A., Anglin, C., Harwin, W., & Romilly, D. P. (1994) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.340872 · Cited by 138 · cited 1×
“The cost of robotic devices not only includes the initial development of the device, but also device’s maintenance, training and therapist’s set up time [85].”
BackgroundRobot-mediated upper limb physiotherapy for patients with spastic hemiparesis: A preliminary study
Fazekas, G., Horváth, M., Troznai, T., & Toth, A. (2007) · Acta Dermato Venereologica · doi:10.2340/16501977-0087 · Cited by 138 · cited 1×
“tional therapy [20–22].”
Evidenzbasierte Armrehabilitation
Platz, T. (2003) · Der Nervenarzt · doi:10.1007/s00115-003-1549-7 · Cited by 128 · cited 2×
“L -E X O S [6 7 ] 5 (4 ac ti v e an d”
BackgroundBonato, P. (2004) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-1-1 · Cited by 124
Dampace: dynamic force-coordination trainer for the upper extremities
Stienen, A. H. A., Hekman, E. E. G., van der Helm, F. C. T., Prange, G. B., Jannink, M. J. A., Aalsma, A. M. M., & van der Kooij, H. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428519 · Cited by 124 · cited 12×
“Example of robotic devices that can provide such training are: GENTLE/s, Dampace, the Armeo Spring and ARMin robot.”
BackgroundInfluentialA novel paradigm for patient-cooperative control of upper-limb rehabilitation robots
Mihelj, M., Nef, T., & Riener, R. (2007) · Advanced Robotics · doi:10.1163/156855307780851975 · Cited by 116
Lo, A., Guarino, P., Krebs, H. I., Volpe, B. T., Bever, C. T., Duncan, P. W., Ringer, R. J., Wagner, T. H., Richards, L. G., Bravata, D. M., et al. (2009) · Neurorehabilitation and neural repair · doi:10.1177/1545968309338195 · Cited by 113 · cited 1×
“Some studies showed effectiveness of robotic devices in comparison to usual or intensive therapy techniques [36,52,86,87].”
ResultRabadi, M. H., Galgano, M. A., Lynch, D., Akerman, M. B., LESSER, M. L., & Volpe, B. T. (2008) · Clinical Rehabilitation · doi:10.1177/0269215508095358 · Cited by 91
Design Issues for Therapeutic Robot Systems: Results from a Survey of Physiotherapists
Lee, M., Rittenhouse, M., & Abdullah, H. A. (2005) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-004-7194-y · Cited by 86 · cited 2×
“This issue is due to factors such as lack of clinical evidence, limited functionality, cost constraints, safety concerns, equipment size and usability issues [83].”
BackgroundEllis, M. D., Sukal‐Moulton, T., & Dewald, J. P. A. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2017111 · Cited by 83 · cited 1×
“The Arm Coordination Training robot (ACT 3D [57]) is developed based on the aspects of GENTLE/s system.”
MethodHesse, S., Werner, C., Pohl, M., Mehrholz, J., Puzich, U., & Krebs, H. I. (2008) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318186b4bc · Cited by 82 · cited 1×
“Some studies showed effectiveness of robotic devices in comparison to usual or intensive therapy techniques [36,52,86,87].”
ResultARMin - Exoskeleton Robot for Stroke Rehabilitation
Nef, T., Guidali, M., Klamroth-Marganska, V., & Riener, R. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03889-1_35 · Cited by 82
Wrist Rehabilitation Following Stroke: Initial Clinical Results
Charles, S. K., Krebs, H. I., Volpe, B. T., Lynch, D., & Hogan, N. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501040 · Cited by 82 · cited 1×
“The first clinical results with this module [44] showed that it provides an effective means for wrist rehabilitation.”
BackgroundShoulder actuation mechanisms for arm rehabilitation exoskeletons
Nef, T., & Riener, R. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762794 · Cited by 78 · cited 1×
“avoids shoulder stress from misalignment of the robot and anatomical joint axes when lifting the upper arm above face level [72].”
BackgroundIwamuro, B. T., Cruz, E. G., Connelly, L., Fischer, H. C., & Kamper, D. G. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.04.022 · Cited by 70
Toth, A., Fazekas, G., Arz, G., Jurák, M., & Horváth, M. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501067 · Cited by 67 · cited 3×
“Figure 6 [right (down)] [61] depicts REHAROB therapy system.”
BackgroundMethodImproving backdrivability in geared rehabilitation robots
Nef, T., & Lum, P. S. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0437-0 · Cited by 63
Fazekas, G., Horváth, M., & Toth, A. (2006) · International Journal of Rehabilitation Research · doi:10.1097/01.mrr.0000230050.16604.d9 · Cited by 59 · cited 2×
“Four healthy subjects and eight patients went under robotic training that showed significant improvement in functionality and spasticity [63].”
BackgroundStandardized voluntary force measurement in a lower extremity rehabilitation robot
Bolliger, M., Banz, R., Dietz, V., & Lünenburger, L. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-23 · Cited by 53
Three-Dimensional Multi-Degree-of-Freedom Arm Therapy Robot (ARMin)
Nef, T., & Riener, R. (2011) · Springer eBooks · doi:10.1007/978-1-4471-2277-7_9 · Cited by 28 · cited 4×
“(Left) (a) Armeo Power, (b) Armeo Spring and (c) Armeo Boom [23] and Teach-and-repeat trajectories for passive mobilization (right) [74].”
MethodInfluentialToth, A., Nyitrai, D., Jurák, M., Merksz, I., Fazekas, G., & Dénes, Z. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209481 · Cited by 23
Cited by
A Review on Upper Limb Rehabilitation Robots
Qassim, H. M., & Wan Hasan, W. Z. (2020) · Applied Sciences · doi:10.3390/app10196976 · Cited by 199
“Stroke is considered one of the leading causes of death; it comes in the third place after heart disease and cancer [1].”
Background
Metadata
- Authors
- Babaiasl, M., Mahdioun, S. H., Jaryani, P., & Yazdani, M.
- Venue
- Disability and Rehabilitation: Assistive Technology
- Publisher
- Informa UK Limited
- Published
- 2015-01-20
- Volume
- 11
- Issue
- 4
- Pages
- 1-18
- ISSN
- 1748-3107 (ISSN-L)
- 1748-3115
- OpenAlex
- W2069438591
- Cited by
- 182
- References
- 88
- FWCI
- 11.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.